A Standardized Parameter-Free Algorithm for Combined Intravoxel Incoherent Motion and Diffusion Kurtosis Analysis of Diffusion Imaging Data.

Abstract:

OBJECTIVES:The aims of this study were to implement and systematically evaluate the performance of a new parameter-free segmented algorithm for analysis of diffusion imaging data using a combined intravoxel incoherent motion and diffusion kurtosis imaging (IVIM-DKI) model of spin diffusion in comparison with the simpler intravoxel incoherent motion (IVIM) model. MATERIALS AND METHODS:A multistep algorithm was implemented intended to separate diffusion kurtosis from IVIM effects in multi-b-value diffusion measurements using an adaptive b-value threshold technique. For each possible b-value threshold (separating diffusion and perfusion effects), diffusion kurtosis analysis of high b-values is followed by IVIM analysis keeping kurtosis parameters fixed. The b-value threshold with smallest Akaike information criterion is chosen as best model solution. The algorithm was tested in diffusion data sets of the upper abdomen from 8 healthy volunteers with 16 different b-values and compared with a standard multistep IVIM analysis. RESULTS:The proposed algorithm could successfully be applied to all data sets and provided a significantly better fit of the observed signal decay in all assessed organs (all P < 0.03). Using the proposed IVIM-DKI model of diffusion instead of an IVIM model had a systematic impact on the resulting IVIM parameters: The pure diffusion coefficient and the pseudodiffusion coefficient were significantly increased (P < 0.03 in all assessed organs), accompanied by a decrease in the perfusion fraction in liver, pancreas, renal cortex, and skeletal muscle (all P < 0.02). Optimal b-value thresholds separating diffusion from perfusion effects had a tendency to lower values when the IVIM-DKI model was used. CONCLUSIONS:The proposed algorithm provides a new approach for separation of IVIM and kurtosis effects of diffusion data without organ-specific adaptation.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Wurnig MC,Kenkel D,Filli L,Boss A

doi

10.1097/RLI.0000000000000223

subject

Has Abstract

pub_date

2016-03-01 00:00:00

pages

203-10

issue

3

eissn

0020-9996

issn

1536-0210

journal_volume

51

pub_type

杂志文章
  • Magnetic resonance imaging as a monitor of changes in the irradiated rat brain. An aid in determining the time course of events in a histologic study.

    abstract:RATIONALE AND OBJECTIVES:Optimal dose schedules and total dose of ionizing radiation for human central nervous system malignancy are not known. An animal model has been developed for the investigation of rat central nervous system response to proton irradiation using magnetic resonance imaging (MRI). A clinical MRI dev...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199504000-00003

    authors: Kennedy AS,Archambeau JO,Archambeau MH,Holshouser B,Thompson J,Moyers M,Hinshaw D Jr,Slater JM

    更新日期:1995-04-01 00:00:00

  • Blood velocity calculated from volumetric dynamic computed tomography angiography.

    abstract:OBJECTIVE:Though functional intravascular parameters such as blood velocity and direction of blood flow are available via imaging modalities such as Doppler ultrasound and phase contrast magnetic resonance imaging, such quantitative information is not yet supported by computed tomography (CT). In this study, we examine...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181ea3588

    authors: Barfett JJ,Fierstra J,Mikulis DJ,Krings T

    更新日期:2010-12-01 00:00:00

  • Searching for lung nodules. Visual dwell indicates locations of false-positive and false-negative decisions.

    abstract::Eye position recordings made while radiologists searched chest images for lung nodules showed that regions falsely reported positive or suspicious received prolonged visual attention. Correlation of regional fixation dwell time with independent ratings of image features indicated that more than 90% of false-positive d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kundel HL,Nodine CF,Krupinski EA

    更新日期:1989-06-01 00:00:00

  • The effects of orientation on volume measurements of human left ventricular casts.

    abstract::Biplane angiocardiography has emerged as a standard method for calculating left ventricular volume measurements. Validation of such measurements has separately been made for several projections of silicone casts of the left ventricle. This study was undertaken to establish and compare the regression lines for left ven...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011000-00002

    authors: Lipton MJ,Hayashi TT,Davis PL,Carlsson E

    更新日期:1980-11-01 00:00:00

  • Toward clinical X-ray phase-contrast CT: demonstration of enhanced soft-tissue contrast in human specimen.

    abstract:OBJECTIVES:X-ray computed tomography (CT) using phase contrast can provide images with greatly enhanced soft-tissue contrast in comparison to conventional attenuation-based CT. We report on the first scan of a human specimen recorded with a phase-contrast CT system based on an x-ray grating interferometer and a convent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e21866

    authors: Donath T,Pfeiffer F,Bunk O,Grünzweig C,Hempel E,Popescu S,Vock P,David C

    更新日期:2010-07-01 00:00:00

  • Feasibility of real-time magnetic resonance-guided angioplasty and stenting of renal arteries in vitro and in Swine, using a new polyetheretherketone-based magnetic resonance-compatible guidewire.

    abstract:OBJECTIVES:Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. MATERIAL AND METHODS:The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft ti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31819b00f1

    authors: Kos S,Huegli R,Hofmann E,Quick HH,Kuehl H,Aker S,Kaiser GM,Borm PJ,Jacob AL,Bilecen D

    更新日期:2009-04-01 00:00:00

  • Magnetic resonance imaging-guided percutaneous biopsy of mediastinal masses: diagnostic performance and safety.

    abstract:OBJECTIVE:The objective of this study was to evaluate the diagnostic performance and safety of magnetic resonance (MR) imaging-guided percutaneous mediastinal biopsy procedures using a 0.23-T open MR system with optical tracking navigation. MATERIALS AND METHODS:A retrospective analysis of 59 participants (38 males an...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0b013e31827a4a17

    authors: Lü Y,Fritz J,Li C,Liu M,Lee P,Wu L,Carrino JA

    更新日期:2013-06-01 00:00:00

  • Renal blood oxygenation level-dependent imaging: contribution of R2 to R2* values.

    abstract:OBJECTIVES:The aim of this study was to assess the impact of oral water and intravenous furosemide challenges on blood oxygenation level-dependent magnetic resonance imaging measurements in the kidney and to examine the contribution of R2 (=1/T2) to changes in R2* (=1/T2*). MATERIALS AND METHODS:This Health Insurance ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182823591

    authors: Vivier PH,Storey P,Chandarana H,Yamamoto A,Tantillo K,Khan U,Zhang JL,Sigmund EE,Rusinek H,Babb JS,Bubenheim M,Lee VS

    更新日期:2013-07-01 00:00:00

  • Contrast and electrolyte dynamics of the intravenous pyelogram. II. Disparities in serum and urine concentrations of meglumine and anion.

    abstract::Intravenous or intra-aortic injections of meglumine iothalamate in dogs indicate a slightly different tissue distribution and excretory pattern of the meglumine cation and the iothalamate anion. Differences in serum and urinary concentrations of these ions suggest some cellular penetration of the meglumine anion. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197507000-00004

    authors: Lasser EC,Lang JH,Hamblin AE,Rosen L

    更新日期:1975-07-01 00:00:00

  • Evaluation of iron content in human cerebral cavernous malformation using quantitative susceptibility mapping.

    abstract:OBJECTIVES:The aims of this study were to investigate and validate quantitative susceptibility mapping (QSM) for lesional iron quantification in cerebral cavernous malformations (CCMs). MATERIALS AND METHODS:Magnetic resonance imaging studies were performed in phantoms and 16 patients on a 3-T scanner. Susceptibility ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000043

    authors: Tan H,Liu T,Wu Y,Thacker J,Shenkar R,Mikati AG,Shi C,Dykstra C,Wang Y,Prasad PV,Edelman RR,Awad IA

    更新日期:2014-07-01 00:00:00

  • AUR Memorial Award 1993. A drug system (PDH) for interventional radiology. Synthesis, properties, and efficacy.

    abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199312000-00001

    authors: Weissleder R,Bogdanov A,Frank H,Nossiff N,Bogdanova A,Schaffer BK,Brady T,Wittenberg J

    更新日期:1993-12-01 00:00:00

  • The effect of computed tomographic scan orientation on information loss in the three-dimensional reconstruction of tripod zygomatic fractures.

    abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199105000-00009

    authors: Levy RA,Kellman RM,Rosenbaum AE

    更新日期:1991-05-01 00:00:00

  • Nonparametric estimation of degenerate ROC data sets used for comparison of imaging systems.

    abstract::Maximum likelihood estimation, assuming a binormal model, has been used extensively to estimate the area under receiver operating characteristic (ROC) curves and thus provide an index of diagnostic accuracy for the comparison of two imaging systems. However, in some instances, a degenerate data set results in a fitted...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199007000-00016

    authors: Rockette HE,Obuchowski NA,Gur D

    更新日期:1990-07-01 00:00:00

  • Gelatin encapsulated nitrogen microbubbles as ultrasonic contrast agents.

    abstract::Gelatin encapsulated nitrogen microbubbles were effective ultrasonic contrast agents in in vitro phantom and in vivo rabbit V2 carcinoma studies. Intra-arterial injection of 80-micrometer gelatin encapsulated nitrogen microbubbles appeared to improve tumor visualization by rim enhancement, which persisted for several ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198005000-00013

    authors: Carroll BA,Turner RJ,Tickner EG,Boyle DB,Young SW

    更新日期:1980-05-01 00:00:00

  • Antiproliferative effects of the antiallergic agent azelastine on human aortic smooth-muscle cells: an in vitro study.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to examine the effects of azelastine on proliferation, clonogenic activity, cell-cycle, and migration of human aortic smooth-muscle cells (haSMCs) in vitro. METHODS:HaSMCs were treated for 4 days with azelastine (1 micromol/L, 25 micromol/L, 50 micromol/L). Half of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200205000-00002

    authors: Schöber W,Wiskirchen J,Kehlbach R,Gebert R,Rodegerdts E,Betsch A,Johst U,Feuls R,Claussen CD,Duda SD

    更新日期:2002-05-01 00:00:00

  • Comprehensive assessment of renal function and vessel morphology in potential living kidney donors: an MRI-based approach.

    abstract:OBJECTIVES:To test the feasibility of a single MR-based examination allowing for the comprehensive assessment of renal anatomy, function, and vascular status in candidates for kidney transplantation. MATERIALS AND METHODS:Twelve healthy potential kidney donors (mean age: 47 +/- 14 [standard deviation] years, 3 men and...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0b013e3181b35a70

    authors: Rossi C,Boss A,Artunc F,Yildiz S,Martirosian P,Dittmann H,Claussen CD,Heyne N,Schick F,Schlemmer HP

    更新日期:2009-11-01 00:00:00

  • Initial evaluation of non-contrast-enhanced magnetic resonance angiography in patients with peripheral arterial occlusive disease at 7 T.

    abstract:OBJECTIVES:The aim of this study was to achieve initial experience with non-contrast-enhanced (ne) magnetic resonance angiography (MRA) of the lower leg arteries in patients with peripheral arterial occlusive disease (PAOD) at 7 T. MATERIALS AND METHODS:Seven patients with PAOD were examined on a 7-T whole-body magnet...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000044

    authors: Fischer A,Maderwald S,Johst S,Orzada S,Ladd ME,Umutlu L,Lauenstein TC,Kniemeyer HW,Nassenstein K

    更新日期:2014-05-01 00:00:00

  • Characterization of radial forces in Z stents.

    abstract:RATIONAL AND OBJECTIVES:The purpose of this study was to evaluate the effects of variation in design parameters on the resultant radial force. We evaluated the influence of wire gauge, leg length, and number of bends on the radial force produced by z stents and compared these with radial forces produced by commercial s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200109000-00004

    authors: Snowhill PB,Nosher JL,Siegel RL,Silver FH

    更新日期:2001-09-01 00:00:00

  • Dual source dual energy MDCT: comparison of 80 kVp and weighted average 120 kVp data for conspicuity of hypo-vascular liver metastases.

    abstract:PURPOSE:To determine whether liver metastases conspicuity is improved at 80 kVp when compared with weighted average (WA) simulated 120 kVp data using dual source dual energy CT. METHODS:A total of 11 patients with 44 hypo-vascular liver metastases underwent contrast enhanced Dual Energy CT (DECT). In all cases the sub...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181dfda78

    authors: Robinson E,Babb J,Chandarana H,Macari M

    更新日期:2010-07-01 00:00:00

  • Some practical issues of experimental design and data analysis in radiological ROC studies.

    abstract::Receiver operating characteristic (ROC) analysis has been used in a broad variety of medical imaging studies during the past 15 years, and its advantages over more traditional measures of diagnostic performance are now clearly established. But despite the essential simplicity of the approach, workers in the field ofte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198903000-00012

    authors: Metz CE

    更新日期:1989-03-01 00:00:00

  • Magnetic resonance imaging-histologic correlation of small hepatocellular carcinomas adenomatous hyperplasias.

    abstract:RATIONALE AND OBJECTIVES:Hepatocellular carcinomas (HCCs) usually consist of components of different histologic grade. Using surgically resected specimens, the authors obtained high-resolution magnetic resonance (MR) images and studied the relationship between histologic grade of HCCs and MR signal intensity. METHOD:I...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199308000-00007

    authors: Inoue E,Kuroda C,Narumi Y,Fujita M,Kadota T,Kuriyama K,Yoshioka H,Ishiguro S,Sasaki Y,Imaoka S

    更新日期:1993-08-01 00:00:00

  • Digital radiography versus conventional radiography for the detection of a skull fracture under varying exposure parameters.

    abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199303000-00010

    authors: Langen HJ,Klein HM,Wein B,Schiwy-Bochat KH,Stargardt A,Günther RW

    更新日期:1993-03-01 00:00:00

  • Quantitative computed tomography of the lungs and airways in healthy nonsmoking adults.

    abstract:OBJECTIVES:The purposes of this study were to evaluate the reference range of quantitative computed tomography (QCT) measures of lung attenuation and airway parameter measurements in healthy nonsmoking adults and to identify sources of variation in those measures and possible means to adjust for them. MATERIALS AND ME...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318262292e

    authors: Zach JA,Newell JD Jr,Schroeder J,Murphy JR,Curran-Everett D,Hoffman EA,Westgate PM,Han MK,Silverman EK,Crapo JD,Lynch DA,COPDGene Investigators.

    更新日期:2012-10-01 00:00:00

  • Gadobutrol-enhanced, three-dimensional, dynamic MR imaging with MR cholangiography for the preoperative evaluation of bile duct cancer.

    abstract:PURPOSE:To evaluate the diagnostic performance of 1.0-M gadobutrol-enhanced, 3-dimensional (3D), dynamic MR images with 3D-MR cholangiography (MRC) in the preoperative evaluation of bile duct cancer staging and resectability. MATERIALS AND METHODS:Our institutional review board approved this retrospective study. Sixty...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2eeb1

    authors: Ryoo I,Lee JM,Chung YE,Park HS,Kim SH,Han JK,Choi BI

    更新日期:2010-04-01 00:00:00

  • Sonography of the kidneys in hemolytic uremic syndrome.

    abstract::The sonographic appearance of kidneys in patients presenting with acute renal failure due to hemolytic-uremic syndrome (HUS) was evaluated and compared with that in an age-matched control series. In nine patients with HUS, the renal cortex was typically hyperechogenic and the renal pyramids appeared sonolucent. The re...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198607000-00006

    authors: Kenney PJ,Brinsko RE,Patel DV,Spitzer RE,Farrar FM

    更新日期:1986-07-01 00:00:00

  • Lactate accumulation in ischemic- and anoxic-isolated rat hearts assessed by H-1 spectroscopy.

    abstract::Proton magnetic resonance (MR) spectroscopy with homonuclear editing was used to assess lactate accumulation in ischemic and anoxic hearts perfused according to the Langendorff method. An increase in the lactate signal was observed after 5 minutes of ischemia and after 10 to 20 minutes of anoxia. This study demonstrat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198708000-00004

    authors: Richards TL,Terrier F,Sievers RE,Lipton MJ,Moseley ME,Higgins CB

    更新日期:1987-08-01 00:00:00

  • CTA contrast enhancement of the aorta and pulmonary artery: the effect of saline chase injected at two different rates in a canine experimental model.

    abstract:OBJECTIVE:To investigate the effect of saline chase injected at 2 different rates on computed tomography (CT) angiography. MATERIALS AND METHODS:This study was approved by our institutional animal study committee. Three injection protocols were used; contrast injection (24 mL, 0.8 mL/s) without saline chase (protocol ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318032a9fe

    authors: Lee CH,Goo JM,Bae KT,Lee HJ,Kim KG,Chun EJ,Park CM,Im JG

    更新日期:2007-07-01 00:00:00

  • Magnetic resonance osteodensitometry in human heel bones: correlation with quantitative computed tomography using different measuring parameters.

    abstract:RATIONALE AND OBJECTIVES:Density of trabecular bone structures in human heel bones was assessed by 3D magnetic resonance (MR) gradient echo imaging (GEI) with multiple echoes. Different spatial resolutions were applied to investigate the influence of the pixel size on signal characteristics in GEI and to find suitable ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200007000-00001

    authors: Machann J,Schnatterbeck P,Raible A,Lutz O,Claussen CD,Schick F

    更新日期:2000-07-01 00:00:00

  • D-galactose-based signal-enhanced color Doppler sonography of breast tumors and tumorlike lesions.

    abstract:RATIONALE AND OBJECTIVES:This study sought to evaluate prospectively the diagnostic potential of unenhanced and enhanced color Doppler and power Doppler for the differentiation of tumors and tumorlike lesions of the breast. METHODS:Ninety-two patients with 110 tumors or tumorlike lesions of the breast were investigate...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199902000-00003

    authors: Schroeder RJ,Maeurer J,Vogl TJ,Hidajat N,Hadijuana J,Venz S,Weber S,Felix R

    更新日期:1999-02-01 00:00:00

  • Whole-body diffusion-weighted imaging with apparent diffusion coefficient mapping for treatment response assessment in patients with diffuse large B-cell lymphoma: pilot study.

    abstract:OBJECTIVES:The aim of this pilot study was to assess post-treatment apparent diffusion coefficient (ADC) changes of diffuse large B-cell lymphoma lesions on respiratory-gated whole-body diffusion-weighted imaging (DWI), with integrated (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182087b03

    authors: Lin C,Itti E,Luciani A,Zegai B,Lin SJ,Kuhnowski F,Pigneur F,Gaillard I,Paone G,Meignan M,Haioun C,Rahmouni A

    更新日期:2011-05-01 00:00:00