Magnetic resonance imaging-guided percutaneous biopsy of mediastinal masses: diagnostic performance and safety.

Abstract:

OBJECTIVE:The objective of this study was to evaluate the diagnostic performance and safety of magnetic resonance (MR) imaging-guided percutaneous mediastinal biopsy procedures using a 0.23-T open MR system with optical tracking navigation. MATERIALS AND METHODS:A retrospective analysis of 59 participants (38 males and 21 females; mean age, 45 years; range, 16-73 years) who underwent MR imaging-guided percutaneous mediastinal biopsy procedures was performed. The access techniques included extrapleural (40 of 59; 67.8%) and transpulmonary (19 of 59; 32.2%) needle paths. Tissue sampling techniques included fine-needle aspiration (22 of 59; 37.3%) and core-needle biopsy (37 of 59; 62.7%). Histopathological analysis of surgical specimen and clinical and imaging follow-ups were used as the reference standard. The procedures were evaluated for technical success rate, number of biopsy passes, diagnostic performance, procedure time, and complications. RESULTS:Technical success was achieved in 57 of the 59 procedures (96.6%). For the fine-needle aspiration, a mean of 3 passes (range, 2-4 passes) was performed. For the core-needle biopsy, a mean of 4 passes (range, 3-6 passes) was performed. Pathological and cytological analysis of biopsy specimens showed 41 of 57 malignant lesions (71.9%) and 16 of 57 benign lesions (28.1%), with a sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 93.2% (41 of 44), 100% (13 of 13), 100% (41 of 41), 81.2% (13 of 16), and 94.7% (54 of 57), respectively. Procedure time was 30 minutes (range, 20-50 minutes). Mild hemoptysis occurred in 3 cases, and in 2 cases, a small pneumothorax occurred. CONCLUSIONS:Magnetic resonance imaging-guided biopsy of mediastinal masses has a high diagnostic performance and is safe for use in clinical practice.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Lü Y,Fritz J,Li C,Liu M,Lee P,Wu L,Carrino JA

doi

10.1097/RLI.0b013e31827a4a17

subject

Has Abstract

pub_date

2013-06-01 00:00:00

pages

452-7

issue

6

eissn

0020-9996

issn

1536-0210

journal_volume

48

pub_type

临床试验,杂志文章
  • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

    abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200207000-00005

    authors: Ropers D,Regenfus M,Stilianakis N,Birke S,Kessler W,Moshage W,Laub G,Daniel WG,Achenbach S

    更新日期:2002-07-01 00:00:00

  • Searching for lung nodules. Visual dwell indicates locations of false-positive and false-negative decisions.

    abstract::Eye position recordings made while radiologists searched chest images for lung nodules showed that regions falsely reported positive or suspicious received prolonged visual attention. Correlation of regional fixation dwell time with independent ratings of image features indicated that more than 90% of false-positive d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kundel HL,Nodine CF,Krupinski EA

    更新日期:1989-06-01 00:00:00

  • Deep Learning on Conventional Magnetic Resonance Imaging Improves the Diagnosis of Multiple Sclerosis Mimics.

    abstract:OBJECTIVES:The aims of this study were to present a deep learning approach for the automated classification of multiple sclerosis and its mimics and compare model performance with that of 2 expert neuroradiologists. MATERIALS AND METHODS:A total of 268 T2-weighted and T1-weighted brain magnetic resonance imagin scans ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000735

    authors: Rocca MA,Anzalone N,Storelli L,Del Poggio A,Cacciaguerra L,Manfredi AA,Meani A,Filippi M

    更新日期:2020-10-26 00:00:00

  • Personal computer needs for the radiologist.

    abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00015

    authors: Newell JD,Hunter TB

    更新日期:1986-02-01 00:00:00

  • Contrast gradient and the detection of lung nodules.

    abstract::The effects of edge gradient and blur on the detection pulmonary nodules were studied, using a test series of 175 artificial nodules on 30 chest films. The nodules were of homogeneous texture, about 1 cm in diameter and had a mean contrast of .12. Six observers viewed the film set, scoring both location and confidence...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197901000-00004

    authors: Kundel HL,Revesz G,Toto L

    更新日期:1979-01-01 00:00:00

  • Saturation kinetics of iopanoate in dogs with an intact enterohepatic circulation. Before and after phenobarbital induction.

    abstract::Capacity-limited elimination of sodium iopanoate and a reproducible apparent transport maximum (Tm) were demonstrated in nonoperated dogs having an intact enterohepatic circulation and normal endogenous bile salt pool. Using a multiple infusion technique, estimation of apparent Tm of iopanoate in the liver was possibl...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197601000-00007

    authors: Herzog RJ,Nelson JA,Staubus AE

    更新日期:1976-01-01 00:00:00

  • Experimental arterial stent placement. Comparison of a new Nitinol stent and Wallstent.

    abstract:RATIONALE AND OBJECTIVES:To compare technical aspects and neointima formation of a new Nitinol stent and a Wallstent. METHODS:A Nitinol sten and a Wallstent were placed into the iliac arteries of 14 sheep (total of 28 stents) and followed angiographically. Seven sheep were killed after 1 month and 7 after 4.5 months. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199507000-00004

    authors: Schürmann K,Vorwerk D,Kulisch A,Stroehmer-Kulisch E,Biesterfeld S,Stopinski T,Günther RW

    更新日期:1995-07-01 00:00:00

  • Evaluation of radiologist interpretive performance using blinded reads by multiple external readers.

    abstract:OBJECTIVE:To demonstrate a method of assessing radiologic diagnostic agreement utilizing multiple blinded external readers. METHODS:Six body CT studies interpreted by one reader (primary reader) at the host institution were compiled with patient identifiers removed. Brief clinical histories that were available to the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2ee97

    authors: Ryan AF,Semelka RC,Molina PL,Yonkers S,Vaidean G

    更新日期:2010-04-01 00:00:00

  • AUR Memorial Award 1993. A drug system (PDH) for interventional radiology. Synthesis, properties, and efficacy.

    abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199312000-00001

    authors: Weissleder R,Bogdanov A,Frank H,Nossiff N,Bogdanova A,Schaffer BK,Brady T,Wittenberg J

    更新日期:1993-12-01 00:00:00

  • Magnetic resonance imaging assays for dimethyl sulfoxide effect on cancer vasculature.

    abstract:OBJECTIVES:To evaluate the potential of quantitative assays of vascular characteristics based on dynamic contrast-enhanced magnetic resonance imaging (MRI) using a macromolecular contrast medium (MMCM) to search for and measure effects of dimethyl sulfoxide (DMSO) on cancer vasculature with microscopic correlations. M...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318164b71d

    authors: Cyran CC,Sennino B,Chaopathomkul B,Fu Y,Rogut V,Shames DM,Wendland MF,McDonald DM,Brasch RC

    更新日期:2008-05-01 00:00:00

  • Effect of inspiratory and expiratory breathhold on pulmonary perfusion: assessment by pulmonary perfusion magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:The effect of breathholding on pulmonary perfusion remains largely unknown. The aim of this study was to assess the effect of inspiratory and expiratory breathhold on pulmonary perfusion using quantitative pulmonary perfusion magnetic resonance imaging (MRI). METHODS AND RESULTS:Nine healthy v...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000149252.42679.78

    authors: Fink C,Ley S,Risse F,Eichinger M,Zaporozhan J,Buhmann R,Puderbach M,Plathow C,Kauczor HU

    更新日期:2005-02-01 00:00:00

  • Gadobutrol-enhanced, three-dimensional, dynamic MR imaging with MR cholangiography for the preoperative evaluation of bile duct cancer.

    abstract:PURPOSE:To evaluate the diagnostic performance of 1.0-M gadobutrol-enhanced, 3-dimensional (3D), dynamic MR images with 3D-MR cholangiography (MRC) in the preoperative evaluation of bile duct cancer staging and resectability. MATERIALS AND METHODS:Our institutional review board approved this retrospective study. Sixty...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2eeb1

    authors: Ryoo I,Lee JM,Chung YE,Park HS,Kim SH,Han JK,Choi BI

    更新日期:2010-04-01 00:00:00

  • The mini-fellowship in teaching. A senior resident elective.

    abstract::The residency program at the University of Pennsylvania offers a 1-month fellowship for senior residents in medical student education. Instructional philosophy, methods, and content are discussed, observed, practiced, and evaluated. Close supervision and immediate feedback provide training particularly needed by futur...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199006000-00028

    authors: Troupin RH

    更新日期:1990-06-01 00:00:00

  • Segmentation-based attenuation correction in positron emission tomography/magnetic resonance: erroneous tissue identification and its impact on positron emission tomography interpretation.

    abstract:OBJECTIVES:The objective of this study was to evaluate the frequency and characteristics of artifacts in segmentation-based attenuation correction maps (μ-maps) of positron emission tomography/magnetic resonance (PET/MR) and their impact on PET interpretation and the standardized uptake value (SUV) quantification in no...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000131

    authors: Brendle C,Schmidt H,Oergel A,Bezrukov I,Mueller M,Schraml C,Pfannenberg C,la Fougère C,Nikolaou K,Schwenzer N

    更新日期:2015-05-01 00:00:00

  • Mechanical thrombectomy in hemodialysis access shunts using a 5F pigtail rotation catheter. In vitro and in vivo investigations.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the feasibility of mechanical thrombectomy in occluded hemodialysis access shunts by using a newly developed 5F pigtail rotation catheter. METHODS:Thrombosed hemodialysis access shunts were simulated by clotted bovine blood in silicone tubing (diameter 6 mm). After retrograde and a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199907000-00008

    authors: Wildberger J,Schmitz-Rode T,Wein BB,Günther RW

    更新日期:1999-07-01 00:00:00

  • Comparative evaluation of digital radiography versus conventional radiography of fractured skulls.

    abstract:OBJECTIVES:The authors assessed the relative efficacy of conventional and digital storage-phosphor radiographs for the detection of skull fractures. METHODS:Fifty conventional film-screen radiographs (FSR) and 50 digital storage-phosphor radiographs (DR) with 66 fractures were compared. Five radiologists evaluated ima...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199308000-00005

    authors: Langen HJ,Klein HM,Wein B,Stargardt A,Günther RW

    更新日期:1993-08-01 00:00:00

  • Magnetic resonance perfusion of the myocardium: semiquantitative and quantitative evaluation in comparison with coronary angiography and fractional flow reserve.

    abstract:PURPOSE:The aim of this study was to investigate if a quantitative evaluation of a magnetic resonance (MR) perfusion examination of the myocardium can achieve a comparable diagnostic accuracy as a semiquantitative evaluation. METHODS:A total of 31 patients with suspected coronary artery disease underwent MR imaging an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31824f54cb

    authors: Huber A,Sourbron S,Klauss V,Schaefer J,Bauner KU,Schweyer M,Reiser M,Rummeny E,Rieber J

    更新日期:2012-06-01 00:00:00

  • A closed-chest pulmonary artery occlusion/reperfusion model in the pig: detection of experimental pulmonary embolism with MR angiography and perfusion MR imaging.

    abstract:RATIONALE AND OBJECTIVES:To establish a pig model suitable for imitating pulmonary emboli to facilitate research in the diagnosis of pulmonary embolism. METHODS:Thirteen animals were anesthetized, mechanically ventilated, and subjected to pulmonary artery catheterization initiated from the right external jugular vein....

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200005000-00003

    authors: Amundsen T,Kvaerness J,Aadahl P,Waage A,Bjermer L,Odegård A,Haraldseth O

    更新日期:2000-05-01 00:00:00

  • Effects of iodinated x-ray contrast media on renal epithelial cells in culture.

    abstract:RATIONALE AND OBJECTIVES:To study cellular mechanisms that cause contrast media nephropathy, an in vitro system for proximal and distal tubular cells has been established to evaluate the influence of x-ray contrast media on tubular function. METHODS:Confluent cell cultures of the two renal cell lines, proximal tubule ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199411000-00002

    authors: Andersen KJ,Christensen EI,Vik H

    更新日期:1994-11-01 00:00:00

  • Development and evaluation of a phantom for dynamic contrast-enhanced imaging.

    abstract:OBJECTIVES:Dynamic contrast-enhanced imaging allows assessing functional information in addition to morphology using various modalities. Several applications have been established in clinical practice; however, there is no standard with respect to injection protocols or postprocessing algorithms. The purpose of this st...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318250a72c

    authors: Brauweiler R,Eisa F,Hupfer M,Nowak T,Kolditz D,Kalender WA

    更新日期:2012-08-01 00:00:00

  • Cerebral embolization in rats induced by red blood cells treated with hypertonic X-ray contrast medium.

    abstract:RATIONALE AND OBJECTIVES:Hypertonic X-ray contrast media induce morphologic changes in red blood cells (RBCs) and reduce their deformability when measured in vitro. This study investigated whether RBCs treated with hypertonic contrast media could induce circulatory as well as metabolic disturbances in vivo. METHODS:Au...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Miyazawa T,Murayama C,Yamanaka T,Fritz-Zieroth B

    更新日期:1993-09-01 00:00:00

  • Robot-assisted biopsy using computed tomography-guidance: initial results from in vitro tests.

    abstract:PURPOSE:We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS:Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was de...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000155285.05672.cf

    authors: Kettenbach J,Kronreif G,Figl M,Fürst M,Birkfellner W,Hanel R,Ptacek W,Bergmann H

    更新日期:2005-04-01 00:00:00

  • Mechanism of hepatic parenchyma-specific contrast of microbubble-based contrast agent for ultrasonography: microscopic studies in rat liver.

    abstract:OBJECTIVE:The objective of this study was to elucidate the mechanism of hepatic parenchyma-specific contrast of Sonazoid (microbubble contrast agent) using microscopic techniques. MATERIALS AND METHODS:Sonazoid was intravenously injected into rats to investigate the microbubble dynamics and distribution within hepatic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31805f2682

    authors: Watanabe R,Matsumura M,Munemasa T,Fujimaki M,Suematsu M

    更新日期:2007-09-01 00:00:00

  • The pediatric tracheostomy: III). An appraisal of xerography.

    abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00002

    authors: Scott JR,Kramer SS,Griscom NT

    更新日期:1978-07-01 00:00:00

  • Semiautomatic lymph node segmentation in multislice computed tomography: impact of slice thickness on segmentation quality, measurement precision, and interobserver variability.

    abstract:OBJECTIVES:To determine the impact of slice thickness on semiautomatic lymph node analysis. MATERIALS AND METHODS:Thoracic multislice computed tomography (MSCT) of 46 patients with NSCLC were reconstructed at 1.0-, 3.0-, and 5.0-mm slice thickness. Two radiologists independently determined long and short axis diameter...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181c443e1

    authors: Buerke B,Puesken M,Beyer F,Gerss J,Weckesser M,Seifarth H,Heindel W,Wessling J

    更新日期:2010-02-01 00:00:00

  • MRI dosimetry: a fast quantitative MRI method to determine 3D absorbed dose distributions.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199903000-00014

    authors: Calmet C,Vincensini D,Bonnet J,Bertino C,Catala A,Martinez M,Joffre F

    更新日期:1999-03-01 00:00:00

  • A double-blind comparative study of Hexabrix and Renografin-76 in aortography and visceral arteriography.

    abstract::A diatrizoate compound (Renografin-76) and low osmolality Hexabrix were compared in a double-blind study of 50 adults undergoing arteriographic examination. Subjective and objective assessment of pain reaction for each contrast injection rated lower overall for Hexabrix. Discomfort associated with Renografin was great...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00012

    authors: Barth KH,Mertens MA

    更新日期:1984-11-01 00:00:00

  • The effect of verification on the assessment of imaging techniques.

    abstract::In order to measure the accuracy of a diagnostic imaging technique, the correctness of each observer decision must be determined. This is often difficult in clinical cases, and various strategies are frequently used to approximate the truth. Experiments using chest radiographs as an example are reported to show the pi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198303000-00018

    authors: Revesz G,Kundel HL,Bonitatibus M

    更新日期:1983-03-01 00:00:00

  • The uptake of manganese dipyridoxal-diphosphate by chemically induced hepatocellular carcinoma in rats. A correlation between contrast-media-enhanced magnetic resonance imaging, tumor differentiation, and vascularization.

    abstract:OBJECTIVES AND RATIONALE:Negative enhancement of implanted liver tumors has been achieved in preclinical studies on manganese dipyridoxal-diphosphate (Mn-DPDP), a new hepatobiliary specific contrast agent for magnetic resonance imaging (MRI). The authors investigated the effects of Mn-DPDP on primary liver cancer and i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199306000-00011

    authors: Ni Y,Marchal G,Zhang X,Van Hecke P,Michiels J,Yu J,Rummeny E,Lodemann KP,Baert AL

    更新日期:1993-06-01 00:00:00

  • Magnetic resonance imaging-histologic correlation of small hepatocellular carcinomas adenomatous hyperplasias.

    abstract:RATIONALE AND OBJECTIVES:Hepatocellular carcinomas (HCCs) usually consist of components of different histologic grade. Using surgically resected specimens, the authors obtained high-resolution magnetic resonance (MR) images and studied the relationship between histologic grade of HCCs and MR signal intensity. METHOD:I...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199308000-00007

    authors: Inoue E,Kuroda C,Narumi Y,Fujita M,Kadota T,Kuriyama K,Yoshioka H,Ishiguro S,Sasaki Y,Imaoka S

    更新日期:1993-08-01 00:00:00