Development and evaluation of a phantom for dynamic contrast-enhanced imaging.

Abstract:

OBJECTIVES:Dynamic contrast-enhanced imaging allows assessing functional information in addition to morphology using various modalities. Several applications have been established in clinical practice; however, there is no standard with respect to injection protocols or postprocessing algorithms. The purpose of this study was to develop a phantom for generating reproducible contrast-enhancement curves and providing a standard for comparison of different protocols and modalities in dynamic imaging. MATERIALS AND METHODS:Our experimental setup consists of a peristaltic pump to generate a water flow through the phantom and a contrast injection pump. The phantom holds a sequence of layers allowing for assessment of perfusion, signal-to-noise ratio, and spatiotemporal resolution; the latter is the spatial resolution of structures with temporally changing contrast. Reproducibility was evaluated by the functional parameters time to peak, mean transit time, and peak enhancement by 24 scans over 4 weeks on a clinical computed tomography scanner. In addition, the area under the curve was evaluated for different injection durations at constant injection volume. Spatiotemporal resolution was assessed by spatial profiles on perfused bore patterns and compared for standard reconstructions, smooth reconstructions, and highly constrained backprojection for local reconstruction (HYPR LR). RESULTS:The phantom showed good reproducibility in repeated measurements, with maximal deviations of 4% for time to peak, 9% for mean transit time, and 8% for peak enhancement. Area under the curve was constant within 3.5% for different injection protocols. For the static case, HYPR LR maintained spatial resolution. For dynamic objects, however, HYPR LR reduced spatial resolution dependent on temporal dynamics by up to 19% for highest dynamics, which was still superior to smooth reconstructions (27%). CONCLUSIONS:The proposed phantom showed good reproducibility and therefore allows for comparing injection protocols or modalities in dynamic imaging. Assessment of spatiotemporal resolution under measurement conditions provides means for assessing postprocessing methods and reconstruction techniques in dynamic imaging.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Brauweiler R,Eisa F,Hupfer M,Nowak T,Kolditz D,Kalender WA

doi

10.1097/RLI.0b013e318250a72c

subject

Has Abstract

pub_date

2012-08-01 00:00:00

pages

462-7

issue

8

eissn

0020-9996

issn

1536-0210

journal_volume

47

pub_type

杂志文章
  • Evaluation of normal prostate tissue, chronic prostatitis, and prostate cancer by quantitative perfusion analysis using a dynamic contrast-enhanced inversion-prepared dual-contrast gradient echo sequence.

    abstract:OBJECTIVE:To quantify independent pharmacokinetic parameters for differentiation of prostate pathology. MATERIAL AND METHODS:Twenty-seven patients with biopsy-proven prostate cancer (PSA: 1.4-16.1 ng/mL) underwent magnetic resonance imaging with a new dynamic contrast-enhanced, inversion-prepared dual-contrast gradien...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31816b2f63

    authors: Franiel T,Lüdemann L,Rudolph B,Rehbein H,Staack A,Taupitz M,Prochnow D,Beyersdorff D

    更新日期:2008-07-01 00:00:00

  • In-vitro assessment of the behavior of magnetic resonance angiography in the presence of constrictions.

    abstract:RATIONALE AND OBJECTIVES:Time-of-flight magnetic resonance angiography (TOF/MRA) is increasingly used to assess the nature and severity of stenotic blood vessels. Flow artifacts associated with high flows and/or narrow constrictions may confuse the interpretation of these studies. Accurate TOF/MRA evaluations demand an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199307000-00011

    authors: Sebok NR,Sebok DA,Wilkerson D,Mezrich RS,Zatina M

    更新日期:1993-07-01 00:00:00

  • Low-dose transaxial tomography. An alternative to computed tomography for the evaluation of anteversion of the femur during childhood.

    abstract::Low-dose transaxial tomography is a technique that can produce cross-sectional images of the hips and femurs in children to permit calculation of the angle of femoral anteversion. Transaxial tomography was compared with computed tomography in terms of measured radiation dose and image quality. Transaxial tomography wa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kushner DC,Cleveland RH,Ehrlich MG,Zaleske DJ,DeLuca SA,Herman TE,Webster EW

    更新日期:1985-12-01 00:00:00

  • The pediatric tracheostomy: III). An appraisal of xerography.

    abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00002

    authors: Scott JR,Kramer SS,Griscom NT

    更新日期:1978-07-01 00:00:00

  • Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000535

    authors: Zhou W,Bartlett DJ,Diehn FE,Glazebrook KN,Kotsenas AL,Carter RE,Fletcher JG,McCollough CH,Leng S

    更新日期:2019-04-01 00:00:00

  • Influence of clinical history upon detection of nodules and other lesions.

    abstract::The authors reexamined a suspected difference in the effects of clinical information upon detection of nodules vs. more diverse lesions by directly incorporating classification specificity into detection ROC analysis. Categorical prompts, correct for specific abnormalities, led to detection superior to unprompted read...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198801000-00011

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Barloon TJ

    更新日期:1988-01-01 00:00:00

  • Low-dose spiral computed tomography of the thorax: comparison with the standard-dose technique.

    abstract:RATIONALE AND OBJECTIVES:This study was conducted to determine whether significant reduction in radiation dose (250 mAs-->50 mAs), in chest computed tomography (CT) using volume acquisition affects image quality or the detectability of pathologic findings in the lung and mediastinum. METHODS:Phantom studies were condu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199802000-00002

    authors: Takahashi M,Maguire WM,Ashtari M,Khan A,Papp Z,Alberico R,Campbell W,Eacobacci T,Herman PG

    更新日期:1998-02-01 00:00:00

  • Comparative cranial CT enhancement in the normal primate.

    abstract::The application of intravenous, intrathecal, and inhalation enhancement techniques to the CT evaluation of the nonhuman primate (Papio cynocephalus/anubis) is described. The falx cerebri cortical vasculature, vein of Galen, straight sinus and tentorium cerebelli were defined with intravenous enhancement. Intrathecal C...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197901000-00014

    authors: Drayer BP,Wolfson SK Jr,Rosenbaum AE,Dujovny M,Boehnke M,Cook EE

    更新日期:1979-01-01 00:00:00

  • Noninvasive estimation of organ weights by postmortem magnetic resonance imaging and multislice computed tomography.

    abstract:OBJECTIVE:Computed tomography (CT) and magnetic resonance imaging (MRI) are introduced as an alternative to traditional autopsy. The purpose of this study was to investigate their accuracy in mass estimation of liver and spleen. METHODS:In 44 cases, the weights of spleen and liver were estimated based on MRI and CT da...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000221323.38443.8d

    authors: Jackowski C,Thali MJ,Buck U,Aghayev E,Sonnenschein M,Yen K,Dirnhofer R,Vock P

    更新日期:2006-07-01 00:00:00

  • Contrast media-induced renal tubular vacuolization. A light and electron microscopic study on rat kidneys.

    abstract::The morphologic changes in healthy rat kidneys (n = 102) were studied 2 or 48 hours after intravenous injection of 1 or 3 g iodine (I)/kg of high-osmolality diatrizoate, low-osmolality iopromide and iohexol, or iso-osmolality iotrolan, as well as after 0.2 or 0.6 g/kg of the high-osmolality magnetic resonance contrast...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199110000-00009

    authors: Tervahartiala P,Kivisaari L,Kivisaari R,Virtanen I,Standertskjöld-Nordenstam CG

    更新日期:1991-10-01 00:00:00

  • Comprehensive assessment of renal function and vessel morphology in potential living kidney donors: an MRI-based approach.

    abstract:OBJECTIVES:To test the feasibility of a single MR-based examination allowing for the comprehensive assessment of renal anatomy, function, and vascular status in candidates for kidney transplantation. MATERIALS AND METHODS:Twelve healthy potential kidney donors (mean age: 47 +/- 14 [standard deviation] years, 3 men and...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0b013e3181b35a70

    authors: Rossi C,Boss A,Artunc F,Yildiz S,Martirosian P,Dittmann H,Claussen CD,Heyne N,Schick F,Schlemmer HP

    更新日期:2009-11-01 00:00:00

  • Critical Questions Regarding Gadolinium Deposition in the Brain and Body After Injections of the Gadolinium-Based Contrast Agents, Safety, and Clinical Recommendations in Consideration of the EMA's Pharmacovigilance and Risk Assessment Committee Recommend

    abstract::For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000374

    authors: Runge VM

    更新日期:2017-06-01 00:00:00

  • Free-Breathing Dynamic Contrast-Enhanced Imaging of the Upper Abdomen Using a Cartesian Compressed-Sensing Sequence With Hard-Gated and Motion-State-Resolved Reconstruction.

    abstract:OBJECTIVES:The aim of this study was to compare a compressed-sensing free-breathing VIBE (fbVIBE) with a conventional breath-hold VIBE (bhVIBE) for dynamic contrast-enhanced imaging of the upper abdomen. MATERIALS AND METHODS:In total, 70 datasets (bhVIBE, n = 30; fbVIBE n = 40; hard-gated [hg] reconstruction, n = 30;...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000607

    authors: Hausmann D,Niemann T,Kreul D,Nocito A,Klarhöfer M,Nickel DM,Kiefer B,Attenberger UI,Zöllner FG,Kubik-Huch RA

    更新日期:2019-11-01 00:00:00

  • Comparison of Routine Brain Imaging at 3 T and 7 T.

    abstract:OBJECTIVE:The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating dis...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000256

    authors: Springer E,Dymerska B,Cardoso PL,Robinson SD,Weisstanner C,Wiest R,Schmitt B,Trattnig S

    更新日期:2016-08-01 00:00:00

  • Spatial resolution analysis of computed tomographic images.

    abstract::Methods are presented for the quantification of spatial resolution in x-ray computed tomographic (CT) images. Model-dependent methods are derived and compared with model independent methods for computation of the Modulation Transfer Function (MTF). These techniques are applied to phantom images of point, line, edge, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198603000-00012

    authors: Assimakopoulos PA,Boyd DP,Jaschke W,Lipton MJ

    更新日期:1986-03-01 00:00:00

  • Short-term effects of a new intravascular nitinol stent in canine arteries.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the short-term effects of a new nitinol stent on canine arteries. METHODS:Eighteen nitinol mesh stents were placed in abdominal aortas, common iliac arteries, and renal arteries of six dogs. Angiography was performed to evaluate the patency rates and structural changes of arteries ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199905000-00007

    authors: Lee KW,Park JH,Chung JW,Kim WS,Lee W,Yeon KM

    更新日期:1999-05-01 00:00:00

  • Comparison of gadobenate dimeglumine with gadopentetate dimeglumine for magnetic resonance imaging of liver tumors.

    abstract:RATIONALE AND OBJECTIVES:To compare gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for magnetic resonance imaging of the liver. METHODS:The contrast agent Gd-BOPTA or Gd-DTPA was administered at a dose of 0.1 mmol/kg to 257 patients suspected of having malignant liver tumors. Dynamic phase ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200111000-00002

    authors: Kuwatsuru R,Kadoya M,Ohtomo K,Tanimoto A,Hirohashi S,Murakami T,Tanaka Y,Yoshikawa K,Katayama H

    更新日期:2001-11-01 00:00:00

  • Thoracic metastases from cervical carcinoma: current status.

    abstract::Thoracic metastases from squamous carcinoma and adenocarcinoma of the cervix were studied by reviewing 245 consecutive cases to describe comparative incidence, natural history, and radiographic patterns. The incidence of chest metastases was higher for adenocarcinoma (20%) than for squamous carcinoma (4%). Few patient...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198003000-00004

    authors: Sostman HD,Matthay RA

    更新日期:1980-03-01 00:00:00

  • Influence of soft tissue (fat and fat-free mass) on ultrasound bone velocity: an in vivo study.

    abstract:RATIONALE AND OBJECTIVES:The authors determine the relative effect of soft-tissue compartments, body fat (percent [%Bfat] and weight [Bfat kg]) and fat-free mass (FFM kg), on measurements of ultrasound bone velocity (UBV m/second). METHODS:The authors measured UBV in proximal phalanxes and body fat and fat-free mass b...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199710000-00005

    authors: Gómez M,Aguado F,Manuel J,Menéndez JM,Revilla M,Villa LF,Cortés J,Rico H

    更新日期:1997-10-01 00:00:00

  • Evaluation of postprocessing dual-energy methods in quantitative computed tomography. Part 2. Practical aspects.

    abstract::Three facets of dual-energy quantitative computed tomography are studied: (1) the algorithm for postprocessing data (the methods of Cann, Laval-Jeantet et al, Goodsitt et al [two methods], and Nickoloff et al); (2) the influence of choice of tissue-equivalent materials for calibration; and (3) the difference between c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199008000-00003

    authors: van Kuijk C,Grashuis JL,Steenbeek JC,Schütte HE,Trouerbach WT

    更新日期:1990-08-01 00:00:00

  • Quantitative computed tomography of the lungs and airways in healthy nonsmoking adults.

    abstract:OBJECTIVES:The purposes of this study were to evaluate the reference range of quantitative computed tomography (QCT) measures of lung attenuation and airway parameter measurements in healthy nonsmoking adults and to identify sources of variation in those measures and possible means to adjust for them. MATERIALS AND ME...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318262292e

    authors: Zach JA,Newell JD Jr,Schroeder J,Murphy JR,Curran-Everett D,Hoffman EA,Westgate PM,Han MK,Silverman EK,Crapo JD,Lynch DA,COPDGene Investigators.

    更新日期:2012-10-01 00:00:00

  • Radiofrequency balloon angioplasty. Rationale and proof of principle.

    abstract::Post-angioplasty restenosis (PARS) in atherosclerotic lesions of medium and small arteries occurs in about one-third of cases in the first year following percutaneous transluminal angioplasty (PTA) (early PARS). PARS includes acute spasm, dissection with reclosure, elastic recoil, fibrocellular proliferative response,...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1097/00004424-198811000-00002

    authors: Becker GJ,Lee BI,Waller BF,Barry KJ,Kaplan J,Connolly R,Dreesen RG,Nardella P

    更新日期:1988-11-01 00:00:00

  • Value of in vivo T2 measurement for myocardial fibrosis assessment in diabetic mice at 11.75 T.

    abstract:OBJECTIVE:The aim of the study was to assess the value of in vivo T2 measurements to noninvasively quantify myocardial fibrosis in diabetic mice at 11.75 T. Diabetic cardiomyopathy is characterized by extracellular matrix alteration and microcirculation impairment. These conditions might provide electrical heterogeneit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318243e062

    authors: Bun SS,Kober F,Jacquier A,Espinosa L,Kalifa J,Bonzi MF,Kopp F,Lalevee N,Zaffran S,Deharo JC,Cozzone PJ,Bernard M

    更新日期:2012-05-01 00:00:00

  • Measured Multipoint Ultra-High b-Value Diffusion MRI in the Assessment of MRI-Detected Prostate Lesions.

    abstract:OBJECTIVES:The aim of this study was to assess quantitative ultra-high b-value (UHB) diffusion magnetic resonance imaging (MRI)-derived parameters in comparison to standard clinical apparent diffusion coefficient (SD-ADC-2b-1000, SD-ADC-2b-1500) for the prediction of clinically significant prostate cancer, defined as G...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000712

    authors: Tavakoli AA,Kuder TA,Tichy D,Radtke JP,Görtz M,Schütz V,Stenzinger A,Hohenfellner M,Schlemmer HP,Bonekamp D

    更新日期:2021-02-01 00:00:00

  • Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging. Application to unilateral lung transplantation.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of magnetic resonance (MR) to image pulmonary perfusion in healthy controls and to detect pulmonary defects in patients with unilateral lung transplantation, using dynamic images after contrast administration. METHODS:Five patients with right lung transplantation a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199706000-00006

    authors: Berthezène Y,Croisille P,Bertocchi M,Houzard C,Bendib K,Revel D

    更新日期:1997-06-01 00:00:00

  • Gadobutrol-enhanced, three-dimensional, dynamic MR imaging with MR cholangiography for the preoperative evaluation of bile duct cancer.

    abstract:PURPOSE:To evaluate the diagnostic performance of 1.0-M gadobutrol-enhanced, 3-dimensional (3D), dynamic MR images with 3D-MR cholangiography (MRC) in the preoperative evaluation of bile duct cancer staging and resectability. MATERIALS AND METHODS:Our institutional review board approved this retrospective study. Sixty...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2eeb1

    authors: Ryoo I,Lee JM,Chung YE,Park HS,Kim SH,Han JK,Choi BI

    更新日期:2010-04-01 00:00:00

  • Intravoxel incoherent motion diffusion-weighted imaging of pancreatic neuroendocrine tumors: prediction of the histologic grade using pure diffusion coefficient and tumor size.

    abstract:PURPOSE:The purpose of this study was to assess the value of intravoxel incoherent motion and diffusion-weighted imaging for predicting the histologic grade of pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:Forty patients with surgically diagnosed PNETs who underwent preoperative magnetic resonance im...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000028

    authors: Hwang EJ,Lee JM,Yoon JH,Kim JH,Han JK,Choi BI,Lee KB,Jang JY,Kim SW,Nickel MD,Kiefer B

    更新日期:2014-06-01 00:00:00

  • A double-blind comparative study of Hexabrix and Renografin-76 in aortography and visceral arteriography.

    abstract::A diatrizoate compound (Renografin-76) and low osmolality Hexabrix were compared in a double-blind study of 50 adults undergoing arteriographic examination. Subjective and objective assessment of pain reaction for each contrast injection rated lower overall for Hexabrix. Discomfort associated with Renografin was great...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00012

    authors: Barth KH,Mertens MA

    更新日期:1984-11-01 00:00:00

  • Analysis of radiocontrast-induced nephropathy by dual-labeled radionuclide clearance.

    abstract:RATIONALE AND OBJECTIVES:This study was devised to develop a method of measuring the acute effects of radiocontrast media on renal function and assessing the relationship of the dose of radiocontrast media infused with the incidence of radiocontrast-induced renal failure. In addition, the drug adenosine phosphate-magne...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-199406000-00004

    authors: Albert SG,Shapiro MJ,Brown WW,Goodgold H,Zuckerman D,Durham R,Kern M,Fletcher J,Wolverson M,Plummer ES

    更新日期:1994-06-01 00:00:00

  • Large-tip-angle spin-echo imaging. Theory and applications.

    abstract:RATIONALE AND OBJECTIVES:Tissue contrast phenomenology was investigated analytically and clinically for a class of magnetic resonance (MR) pulse sequences we call large-tip-angle (LTA) spin-echo (SE) imaging. In comparison to traditional SE sequences (denoted 90 degrees-180 degrees-echo), the LTA sequence is of the for...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199310000-00017

    authors: Elster AD,Provost TJ

    更新日期:1993-10-01 00:00:00