Abstract:
:The authors reexamined a suspected difference in the effects of clinical information upon detection of nodules vs. more diverse lesions by directly incorporating classification specificity into detection ROC analysis. Categorical prompts, correct for specific abnormalities, led to detection superior to unprompted reading when non-nodule trials (various lesion types) were analyzed. Trials that contained pulmonary nodules, or contained no lesions but had been preceded by "possible tuberculosis" or "rule out metastatic disease" prompts, failed to demonstrate the diagnostic prompt superiority. Perceptual responses may differ when nodules are compared with more complex lesions.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Berbaum KS,Franken EA Jr,Dorfman DD,Barloon TJdoi
10.1097/00004424-198801000-00011subject
Has Abstractpub_date
1988-01-01 00:00:00pages
48-55issue
1eissn
0020-9996issn
1536-0210journal_volume
23pub_type
杂志文章abstract:OBJECTIVES:To evaluate the potential of quantitative assays of vascular characteristics based on dynamic contrast-enhanced magnetic resonance imaging (MRI) using a macromolecular contrast medium (MMCM) to search for and measure effects of dimethyl sulfoxide (DMSO) on cancer vasculature with microscopic correlations. M...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318164b71d
更新日期:2008-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To study cellular mechanisms that cause contrast media nephropathy, an in vitro system for proximal and distal tubular cells has been established to evaluate the influence of x-ray contrast media on tubular function. METHODS:Confluent cell cultures of the two renal cell lines, proximal tubule ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199411000-00002
更新日期:1994-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199208000-00012
更新日期:1992-08-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to determine if voxel-based histogram analysis of intravoxel incoherent motion imaging (IVIM) parameters can differentiate various subtypes of renal tumors, including benign and malignant lesions. SUBJECTS AND METHODS:A total of 44 patients with renal tumors who underwent surgery a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000111
更新日期:2015-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000133816.83192.38
更新日期:2004-09-01 00:00:00
abstract::Over the past 120 years, continuous developments in medical imaging has improved diagnosis and treatment for many diseases and has thereby improved treatment outcome and quality of life of many patients. The number of computed tomography (CT) examinations is today increasing by 4% per year worldwide, for a total of ap...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000696
更新日期:2020-09-01 00:00:00
abstract::The use of microbubble contrast agents for general tissue delineation and perfusion enjoys steady interest in ultrasound imaging. Microbubbles as contrast materials require a small dosage and show excellent detection sensitivity. Targeting ligands on the surface of microbubbles permit the selective accumulation of the...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/01.rli.0000199292.88189.0f
更新日期:2006-03-01 00:00:00
abstract::Renal arteriography gives a reliable anatomic delineation of the renal vasculature. However, the presence of renal arterial disease does not determine the physiologic significance of the lesion. The intravenous infusion of saralasin, a specific angiotensin II antagonist, has been investigated as a method for identify...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197711000-00006
更新日期:1977-11-01 00:00:00
abstract::A series of 5-hydroxyacylamino-2,4,6-triiodo-N,N'-hydroxy-alkyl-isophtalamides was prepared in order to study the structural requirements for high water solubility and low toxicity. Among the amides substituted by 2-hydroxyethyl; 2,3-dihydroxypropyl; 1,3-dihydroxypropyl-; and 1,1-dihydroxy-methyl-2-oxyethyl- groups, t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198011001-00065
更新日期:1980-11-01 00:00:00
abstract::The sonographic appearance of kidneys in patients presenting with acute renal failure due to hemolytic-uremic syndrome (HUS) was evaluated and compared with that in an age-matched control series. In nine patients with HUS, the renal cortex was typically hyperechogenic and the renal pyramids appeared sonolucent. The re...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198607000-00006
更新日期:1986-07-01 00:00:00
abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199105000-00009
更新日期:1991-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To assess the abilities of dynamic diffusion-weighted MRI to demonstrate the effects in vivo of a high-viscosity iodinated contrast agent on medullary and cortical blood flow in the rat kidney. METHODS:Dynamic diffusion-weighted, echoplanar MR images obtained from five b-value single-shot acqu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200011000-00001
更新日期:2000-11-01 00:00:00
abstract:OBJECTIVE:To investigate the correlation between intravoxel incoherent motion (IVIM) model-derived parameters and histologically determined microvascularity in pancreatic ductal adenocarcinomas (PDACs) and pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:From April 2013 to May 2014, 42 patients with mal...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000187
更新日期:2015-11-01 00:00:00
abstract::The cytogenetic interactions of ionic (diatrizoate, ioxaglate) and nonionic (iohexol) contrast media (CM) with antineoplastic drugs cyclophosphamide (CPA) and carmustine (CARM) were evaluated in a rat bone marrow cell model. Male Wistar rats were anesthetized with a 6% chloral hydrate solution and divided into five gr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198805000-00011
更新日期:1988-05-01 00:00:00
abstract::We measured the amounts of three types of radiographic contrast media (RCM) that could be entrapped in liposomes prepared by the dehydration-rehydration vesicle (DRV) technique. To make DRVs, one initially makes water-containing, small unilamellar vesicles, adds contrast media and lyophilizes the mixture. Upon rehydra...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198802000-00009
更新日期:1988-02-01 00:00:00
abstract::The efficacy and safety of perfluoroctylbromide as a diagnostic contrast agent for direct lymphography was studied in mongrel dogs. This radiopaque perfluorocarbon has several advantages over Ethiodol. The liquid compound has injection times one-fifth of that required for Ethiodol. When dosages were three to four tim...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197707000-00012
更新日期:1977-07-01 00:00:00
abstract:PURPOSE:To determine whether time-resolved magnetic resonance angiography (TR-MRA) with ultra-low-dose gadolinium chelate (1.5-3.0 mL) can reliably detect or rule out hemodynamically significant disease in the carotid-vertebral artery territory. MATERIALS AND METHODS:Hundred consecutive patients (62 women, 38 men, mea...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31819ca048
更新日期:2009-04-01 00:00:00
abstract::We developed a new, cineangiographic method to accurately measure the dynamic changes in the internal diameter of human arteries in vivo. Cine films were digitized at a spatial resolution of 4 microns/pixel, using a line image sensor. The vessel edges, with a Gaussian fit to a unilateral profile curve of the vessel, w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198909000-00005
更新日期:1989-09-01 00:00:00
abstract::Gelatin encapsulated nitrogen microbubbles were effective ultrasonic contrast agents in in vitro phantom and in vivo rabbit V2 carcinoma studies. Intra-arterial injection of 80-micrometer gelatin encapsulated nitrogen microbubbles appeared to improve tumor visualization by rim enhancement, which persisted for several ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198005000-00013
更新日期:1980-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors analyze the origins of the "clotting issue," the controversy that began in the 1980s when contrast media, once perceived as good flushing agents for catheters because of their assumed anticoagulant properties, came under attack for allegedly causing thromboembolism. Laboratory studi...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:
更新日期:1993-11-01 00:00:00
abstract::French physicians must obtain their patient's consent before carrying out an action that interferes with the patient's corporal integrity. The doctor must use simple, approximate, intelligent, and honest words that help the patient to reach the indispensable decision. Proof of lack of consent lies with the patient. Th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198809001-00006
更新日期:1988-09-01 00:00:00
abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198602000-00015
更新日期:1986-02-01 00:00:00
abstract::The authors conducted an observer performance study to compare breast lesion detection of conventional mammography (CM) with teleradiology (TE) transmitted mammograms. One hundred four abnormal, single-projection mammographic images were transmitted by teleradiology. Abnormalities included 11 cases with skin thickenin...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199010000-00007
更新日期:1990-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Hypertonic X-ray contrast media induce morphologic changes in red blood cells (RBCs) and reduce their deformability when measured in vitro. This study investigated whether RBCs treated with hypertonic contrast media could induce circulatory as well as metabolic disturbances in vivo. METHODS:Au...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1993-09-01 00:00:00
abstract:OBJECTIVE:To evaluate the degree of ischemic changes of the small intestine after arterial embolization of proximal or distal arteries with Gelfoam particles and coils in dogs. METHODS:Superselective arterial embolization in 18 dogs was performed using a coaxial catheter system. Gelfoam occlusion of the proximal level...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199910000-00004
更新日期:1999-10-01 00:00:00
abstract::A diatrizoate compound (Renografin-76) and low osmolality Hexabrix were compared in a double-blind study of 50 adults undergoing arteriographic examination. Subjective and objective assessment of pain reaction for each contrast injection rated lower overall for Hexabrix. Discomfort associated with Renografin was great...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/00004424-198411001-00012
更新日期:1984-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare trabecular bone structure measures obtained in magnetic resonance images of the distal radius and the calcaneus as well as computed tomographic images of the spine versus bone mineral density (BMD) of the spine and the calcaneus in the prediction of osteoporotic spine fracture status...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000129154.50654.4e
更新日期:2004-08-01 00:00:00
abstract::Flow measurements can be made with computed tomography (CT) scanners using iodinated, nonionic contrast media as a first-pass indicator. Ultrafast CT (UFCT) is an ideal machine to make these measurements because of its short scan time (50 mseconds) and interscan delay (< or = 0.6 seconds). Additionally, UFCT can acqui...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199212002-00004
更新日期:1992-12-01 00:00:00
abstract::For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/RLI.0000000000000374
更新日期:2017-06-01 00:00:00
abstract:OBJECTIVES:Pancreatic ductal adenocarcinoma (PDAC) is a very aggressive tumor with a very low 5-year survival rate of 8%. The aims of this study are to determine reference values and physiologic confounders in healthy pancreas and to assess the diagnostic accuracy of ultrasound time-harmonic elastography (THE) in the d...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000638
更新日期:2020-05-01 00:00:00