Influence of soft tissue (fat and fat-free mass) on ultrasound bone velocity: an in vivo study.

Abstract:

RATIONALE AND OBJECTIVES:The authors determine the relative effect of soft-tissue compartments, body fat (percent [%Bfat] and weight [Bfat kg]) and fat-free mass (FFM kg), on measurements of ultrasound bone velocity (UBV m/second). METHODS:The authors measured UBV in proximal phalanxes and body fat and fat-free mass by near infrared interactance in 40 healthy premenopausal women (mean age +/- standard deviation 28.2 +/- 3.8 years). RESULTS:Correlation study (Fisher's r to z) showed that UBV correlated negatively with %Bfat (r = -0.61, P < 0.0001), Bfat kg (r = -0.56, P = 0.0001) and marginally with body weight (r = -0.33, P = 0.0403), but did not correlate with FFM kg or H2O L (both r = -0.08, P not significant). When the correlation test was adjusted for weight and age (partial correlation), the negative correlation between UBV and %Bfat persisted (r = -0.54, P < 0.0005; and r = -0.63, P < 0.0001, respectively) and the correlation with FFM kg, adjusted for weight, became positive and significant (r = 0.55, P < 0.0005). CONCLUSIONS:These results, to our knowledge, are the first to be obtained by in vivo evaluation of UBV in relation to body fat and fat-free mass. Body fat, but not fat-free mass, was the main factor affecting UBV. This confirms the deficiency of UBV measurements, considering that obesity is a protective factor for bone mass.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Gómez M,Aguado F,Manuel J,Menéndez JM,Revilla M,Villa LF,Cortés J,Rico H

doi

10.1097/00004424-199710000-00005

subject

Has Abstract

pub_date

1997-10-01 00:00:00

pages

609-12

issue

10

eissn

0020-9996

issn

1536-0210

journal_volume

32

pub_type

杂志文章
  • Attenuation correction for flexible magnetic resonance coils in combined magnetic resonance/positron emission tomography imaging.

    abstract:INTRODUCTION:Attenuation correction for magnetic resonance (MR) coils is a new challenge that came about with the development of combined MR and positron emission tomography (PET) imaging. This task is difficult because such coils are not directly visible on either PET or MR acquisitions with current combined scanners ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a530f8

    authors: Eldib M,Bini J,Calcagno C,Robson PM,Mani V,Fayad ZA

    更新日期:2014-02-01 00:00:00

  • Evaluation of complex joint motion with computer-based analysis of fluoroscopic sequences.

    abstract:RATIONALE AND OBJECTIVES:To develop a computer-assisted analysis of complex joint motion based on standard fluoroscopic sequences. MATERIALS AND METHODS:Fluoroscopic sequences of 10 normal shoulders and 20 patients after total shoulder arthroplasty were recorded during abduction and adduction. The analysis of the shou...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200202000-00004

    authors: Pfirrmann CW,Huser M,Székely G,Hodler J,Gerber C

    更新日期:2002-02-01 00:00:00

  • Effect of additional cations on the twitching reaction to intracarotid, nonionic contrast media in rabbits.

    abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199009000-00010

    authors: Whisson CC,Evill CA,Sage MR,Wilson AJ

    更新日期:1990-09-01 00:00:00

  • Robot-assisted biopsy using computed tomography-guidance: initial results from in vitro tests.

    abstract:PURPOSE:We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS:Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was de...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000155285.05672.cf

    authors: Kettenbach J,Kronreif G,Figl M,Fürst M,Birkfellner W,Hanel R,Ptacek W,Bergmann H

    更新日期:2005-04-01 00:00:00

  • CTA contrast enhancement of the aorta and pulmonary artery: the effect of saline chase injected at two different rates in a canine experimental model.

    abstract:OBJECTIVE:To investigate the effect of saline chase injected at 2 different rates on computed tomography (CT) angiography. MATERIALS AND METHODS:This study was approved by our institutional animal study committee. Three injection protocols were used; contrast injection (24 mL, 0.8 mL/s) without saline chase (protocol ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318032a9fe

    authors: Lee CH,Goo JM,Bae KT,Lee HJ,Kim KG,Chun EJ,Park CM,Im JG

    更新日期:2007-07-01 00:00:00

  • Specific enhancement of intra-abdominal abscesses with perfluoroctylbromide for CT imaging.

    abstract::Perfluoroctylbromide (PFOB), a radiopaque reticuloendothelial system contrast media for computed tomography, has been shown to accumulate in macrophages. In the current study PFOB was tested in rabbits as an abscess imaging agent. Two abscesses were induced in each of 24 rabbits, one in the liver and the other in the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198409000-00017

    authors: Mattrey RF,Andrè M,Campbell J,Mitten R,Multer F,Hackney D,Long DM,Higgins CB

    更新日期:1984-09-01 00:00:00

  • Assessment of preoperative magnetic resonance imaging staging in patients with hepatocellular carcinoma undergoing resection compared with the seventh American Joint Committee on Cancer System.

    abstract:OBJECTIVES:The aim of this study was to compare the prognostic utility of a staging system using magnetic resonance imaging (MRI) with the seventh American Joint Committee on Cancer (AJCC) staging system in patients with hepatocellular carcinoma (HCC) who underwent hepatic resection. MATERIALS AND METHODS:A total of 1...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182630e8d

    authors: An C,Choi GH,Lee HS,Kim MJ

    更新日期:2012-11-01 00:00:00

  • Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures: Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography.

    abstract:PURPOSE:The aim of this study was to evaluate the diagnostic performance of virtual noncalcium (VNCa) dual-energy computed tomography (DECT) reconstructions enabling visualization of bone marrow edema for characterization of incidental thoracolumbar compression fractures in routine thoracoabdominal staging computed tom...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000458

    authors: Frellesen C,Azadegan M,Martin SS,Otani K,DʼAngelo T,Booz C,Eichler K,Panahi B,Kaup M,Bauer RW,Vogl TJ,Wichmann JL

    更新日期:2018-07-01 00:00:00

  • Breast stereotactic core biopsy washings: abundant cell samples from clinically occult lesions for flow cytometric DNA analysis.

    abstract:RATIONALE AND OBJECTIVES:The object of this study was to determine by flow cytometry the cellular and DNA content of the washings of core biopsy samples and needles obtained during stereotactic core biopsies of clinically occult suspicious lesions. METHODS:Fourteen-gauge core multipass biopsy inner-needle saline washi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199801000-00008

    authors: Stomper PC,Budnick RM,Stewart CC

    更新日期:1998-01-01 00:00:00

  • Antiproliferative effects of the antiallergic agent azelastine on human aortic smooth-muscle cells: an in vitro study.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to examine the effects of azelastine on proliferation, clonogenic activity, cell-cycle, and migration of human aortic smooth-muscle cells (haSMCs) in vitro. METHODS:HaSMCs were treated for 4 days with azelastine (1 micromol/L, 25 micromol/L, 50 micromol/L). Half of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200205000-00002

    authors: Schöber W,Wiskirchen J,Kehlbach R,Gebert R,Rodegerdts E,Betsch A,Johst U,Feuls R,Claussen CD,Duda SD

    更新日期:2002-05-01 00:00:00

  • Diminished cerebrospinal fluid beta-endorphin concentration in monkeys with arachnoiditis.

    abstract::Altered concentrations of brain beta endorphin and spinal cord encephalin have been reported in mice with iatrogenic arachnoiditis. We measured beta-endorphin concentration in cerebrospinal fluid (CSF) in normal monkeys and in monkeys with various degrees of arachnoiditis resulting from myelography and spinal surgery ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198803000-00006

    authors: Lipman BT,Haughton VM

    更新日期:1988-03-01 00:00:00

  • The General Electric-Association of University Radiologists Radiology Research Academic Fellowship (GERRAF). An industry-academic collaboration to improve clinical research in radiology.

    abstract::The association of GE Medical Systems and the AUR represents a unique collaboration between academic radiology and industry that bears important potential for elevating the quality of clinical research in radiology and developing a cadre of high-quality radiologist researchers for the future. The establishment of the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199305000-00001

    authors: Hillman BJ,Fryback DG,Holden RW,McNeil BJ,Molitor RM,Moss AA,Peck PV,Putman CE,Thompson WM

    更新日期:1993-05-01 00:00:00

  • Assessment of a non-ionic contrast medium (Amipaque) in the gastrointestinal tract.

    abstract::Gastrografin and Amipaque with identical iodine content and flavoring were orally administered in 100 ml doses to 10 healthy volunteers in a double-blind crossover study. The nonionic Amipaque has only about one third of the osmolality of Gastrografin, and draws less fluid into the bowel lumen. Consequently there is l...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-197811000-00008

    authors: Johansen JG

    更新日期:1978-11-01 00:00:00

  • Three-dimensional cerebral contrast-enhanced magnetic resonance venography at 3.0 Tesla: initial results using highly accelerated parallel acquisition.

    abstract:OBJECTIVE:The objective of this study was to evaluate a high spatial resolution 3-dimensional (3D) contrast-enhanced magnetic resonance (CE-MR) venography protocol for evaluation of intracranial venous system using highly accelerated parallel imaging at 3.0 T. MATERIALS AND METHODS:Ten patients (4 male, 6 female; age,...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.rli.0000236992.21065.04

    authors: Nael K,Fenchel M,Salamon N,Duckwiler GR,Laub G,Finn JP,Villablanca JP

    更新日期:2006-10-01 00:00:00

  • Observation on the metabolism of iopanoyl (Telepaque) glucuronide in dogs treated with antibiotics.

    abstract::The purpose of our investigation was to determine whether iopanoyl glucuronide, the major metabolite of iopanoic acid (Telepaque), undergoes hydrolysis by bacterial beta-glucuronidase in dogs. The conjugated compound was identified and quantitated by elemental analysis, fluorescent excitation analysis, thin-layer chro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197805000-00011

    authors: Thoeni RF,Goldberg HI,Moss AA,Lin SK,Brito AC

    更新日期:1978-05-01 00:00:00

  • Comparison of observer performance reading from a video CRT vs. reading from film.

    abstract::The developing trend for all medical images to be in digital form raises an important question: should diagnostic interpretations be made directly from a CRT or from some form of hard copy recording of the CRT? This question was studied by having two observers read a series of digital images of the thyroid including b...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198305000-00015

    authors: Keyes JW Jr,Kline RC,Resinger WW,Rose EA,Koral KF,Rogers WL

    更新日期:1983-05-01 00:00:00

  • Perfusion quantitation by ultrafast computed tomography.

    abstract::Flow measurements can be made with computed tomography (CT) scanners using iodinated, nonionic contrast media as a first-pass indicator. Ultrafast CT (UFCT) is an ideal machine to make these measurements because of its short scan time (50 mseconds) and interscan delay (< or = 0.6 seconds). Additionally, UFCT can acqui...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199212002-00004

    authors: Gould RG

    更新日期:1992-12-01 00:00:00

  • Estimating digital information throughput rates for radiology networks. A model.

    abstract::The design and implementation of a digital radiology image management system requires the definition, evaluation, and comparison of appropriate measures of system performance. The mean throughput rate is an important measure of the actual performance of a finished system. The mean throughput rate identifies the transm...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00014

    authors: Cox GG,Templeton AW,Anderson WH,Cook LT,Hensley KS,Dwyer SJ 3rd

    更新日期:1986-02-01 00:00:00

  • Dual Plasma Sampling Method to Determine the Hepatic and Renal Clearance of the 2 Diastereoisomers of Gd-EOB-DTPA.

    abstract:OBJECTIVES:The aim of this study was to develop a method to determine hepatic and renal clearance of the 2 diastereoisomers (Gd-A, Gd-B) of Gd-EOB-DTPA separately. MATERIALS AND METHODS:Between July 2017 and February 2018, 41 patients with hepatic disease were prospectively included. For each patient, 1 mL of iopromid...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000622

    authors: Yuan X,Wang S,Shi W,Cai Y,Chen Y,Chen M,Peng Y,Ao G

    更新日期:2020-03-01 00:00:00

  • Fluorescent bacterial magnetic nanoparticles as bimodal contrast agents.

    abstract:OBJECTIVES:The purpose of this study was to assess whether fluorochrome-coupled bacterial magnetic nanoparticles can be used as bimodal contrast agent for both magnetic resonance imaging (MRI) and near-infrared fluorescence optical (NIRF) imaging of cultured macrophages. MATERIALS AND METHODS:Bacterial magnetic nanopa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000255832.44443.e7

    authors: Lisy MR,Hartung A,Lang C,Schüler D,Richter W,Reichenbach JR,Kaiser WA,Hilger I

    更新日期:2007-04-01 00:00:00

  • Semiautomatic lymph node segmentation in multislice computed tomography: impact of slice thickness on segmentation quality, measurement precision, and interobserver variability.

    abstract:OBJECTIVES:To determine the impact of slice thickness on semiautomatic lymph node analysis. MATERIALS AND METHODS:Thoracic multislice computed tomography (MSCT) of 46 patients with NSCLC were reconstructed at 1.0-, 3.0-, and 5.0-mm slice thickness. Two radiologists independently determined long and short axis diameter...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181c443e1

    authors: Buerke B,Puesken M,Beyer F,Gerss J,Weckesser M,Seifarth H,Heindel W,Wessling J

    更新日期:2010-02-01 00:00:00

  • Multiphase magnetic resonance angiography of the abdominal and pelvic arteries: results of a bicenter multireader analysis.

    abstract:RATIONALE AND OBJECTIVES:The objective is to assess the diagnostic accuracy and interobserver variability of multiphase 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for assessment of abdominal and pelvic vascular disease. METHODS:In 41 patients from two different institutions multiphase 3D-Gd-MRA ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00004424-200201000-00005

    authors: Schoenberg SO,Essig M,Hallscheidt P,Sharafuddin MJ,Stolpen AH,Knopp MV,Yuh WT

    更新日期:2002-01-01 00:00:00

  • Magnetic resonance imaging assays for dimethyl sulfoxide effect on cancer vasculature.

    abstract:OBJECTIVES:To evaluate the potential of quantitative assays of vascular characteristics based on dynamic contrast-enhanced magnetic resonance imaging (MRI) using a macromolecular contrast medium (MMCM) to search for and measure effects of dimethyl sulfoxide (DMSO) on cancer vasculature with microscopic correlations. M...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318164b71d

    authors: Cyran CC,Sennino B,Chaopathomkul B,Fu Y,Rogut V,Shames DM,Wendland MF,McDonald DM,Brasch RC

    更新日期:2008-05-01 00:00:00

  • Cerebral embolization in rats induced by red blood cells treated with hypertonic X-ray contrast medium.

    abstract:RATIONALE AND OBJECTIVES:Hypertonic X-ray contrast media induce morphologic changes in red blood cells (RBCs) and reduce their deformability when measured in vitro. This study investigated whether RBCs treated with hypertonic contrast media could induce circulatory as well as metabolic disturbances in vivo. METHODS:Au...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Miyazawa T,Murayama C,Yamanaka T,Fritz-Zieroth B

    更新日期:1993-09-01 00:00:00

  • Cerebral computed tomography angiography using a low tube voltage (80 kVp) and a moderate concentration of iodine contrast material: a quantitative and qualitative comparison with conventional computed tomography angiography.

    abstract:OBJECTIVE:To investigate the feasibility of an 80-kVp protocol using a moderate concentration contrast material (MC-CM) for cerebral computed tomography angiography by comparison with a conventional 120-kVp protocol using a high concentration contrast material (HC-CM). MATERIALS AND METHODS:Attenuation values and sign...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31823076a4

    authors: Cho ES,Chung TS,Oh DK,Choi HS,Suh SH,Lee HK,Lee KH

    更新日期:2012-02-01 00:00:00

  • Effect of multiple intravenous injections of diatrizoate on iodine concentrations and osmolality. An experimental study in rabbits.

    abstract::Multiple intravenous injections of contrast media are used in radiology, but information regarding corresponding changes in the serum iodine concentrations and osmolality is lacking. We measured the changes in serum iodine concentration and serum osmolality in rabbits after a series of intravenous injections of contra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198703000-00007

    authors: Rubin DI,Kido DK,Morris TW,Fischer HW

    更新日期:1987-03-01 00:00:00

  • Evaluation of postprocessing dual-energy methods in quantitative computed tomography. Part 2. Practical aspects.

    abstract::Three facets of dual-energy quantitative computed tomography are studied: (1) the algorithm for postprocessing data (the methods of Cann, Laval-Jeantet et al, Goodsitt et al [two methods], and Nickoloff et al); (2) the influence of choice of tissue-equivalent materials for calibration; and (3) the difference between c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199008000-00003

    authors: van Kuijk C,Grashuis JL,Steenbeek JC,Schütte HE,Trouerbach WT

    更新日期:1990-08-01 00:00:00

  • Clinical experience with saralasin infusion in hypertensive patients.

    abstract::Renal arteriography gives a reliable anatomic delineation of the renal vasculature. However, the presence of renal arterial disease does not determine the physiologic significance of the lesion. The intravenous infusion of saralasin, a specific angiotensin II antagonist, has been investigated as a method for identify...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197711000-00006

    authors: Tegtmeyer CJ,Latour EA,Vaughan ED Jr,Ayers CR,Carey RM,Wellons HA Jr

    更新日期:1977-11-01 00:00:00

  • New contrast media in cerebral angiography: animal experiments and preliminary clinical studies.

    abstract::The cerebrovascular toxicity of three water-soluble contrast agents with a low hypertonicity (metrizamide, ioxaglate, iopamidol) was tested. Blood-brain barrier damage after carotid injection was assessed using 32P autoradiography and fluorescent microscopy after Evans blue staining. The damage to carotid endothelium ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00058

    authors: Gonsette RE,Liesenborgh L

    更新日期:1980-11-01 00:00:00

  • Reduction of Metal Artifacts and Improvement in Dose Efficiency Using Photon-Counting Detector Computed Tomography and Tin Filtration.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000535

    authors: Zhou W,Bartlett DJ,Diehn FE,Glazebrook KN,Kotsenas AL,Carter RE,Fletcher JG,McCollough CH,Leng S

    更新日期:2019-04-01 00:00:00