Evaluation of normal prostate tissue, chronic prostatitis, and prostate cancer by quantitative perfusion analysis using a dynamic contrast-enhanced inversion-prepared dual-contrast gradient echo sequence.

Abstract:

OBJECTIVE:To quantify independent pharmacokinetic parameters for differentiation of prostate pathology. MATERIAL AND METHODS:Twenty-seven patients with biopsy-proven prostate cancer (PSA: 1.4-16.1 ng/mL) underwent magnetic resonance imaging with a new dynamic contrast-enhanced, inversion-prepared dual-contrast gradient echo sequence (T1/T2*-weighted, 1.65 seconds temporal resolution) using a combined endorectal/body phased-array coil at 1.5 Tesla. Perfusion, blood volume, mean transit time, delay, and dispersion were calculated using a sequential 3-compartment model. Twenty-three patients underwent prostatectomy. For histologic correlation a pathologist mapped areas of normal prostate tissue, chronic prostatitis, and prostate cancer (total of 63 areas) on histologic sections corresponding to the magnetic resonance imaging planes. RESULTS:Compared with normal prostate tissue, low-grade cancer (Gleason score

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Franiel T,Lüdemann L,Rudolph B,Rehbein H,Staack A,Taupitz M,Prochnow D,Beyersdorff D

doi

10.1097/RLI.0b013e31816b2f63

subject

Has Abstract

pub_date

2008-07-01 00:00:00

pages

481-7

issue

7

eissn

0020-9996

issn

1536-0210

pii

00004424-200807000-00001

journal_volume

43

pub_type

杂志文章
  • Stability of MRI paramagnetic contrast media: a proton relaxometric protocol for transmetallation assessment.

    abstract:RATIONALE AND OBJECTIVES:The suitability of paramagnetic complexes as magnetic resonance contrast agents depends on various factors such as their relaxivity, stability, selectivity, and the inertness toward transmetallation by endogenous ions. The transmetallation of a series of 18 gadolinium complexes by the Zn2+ ion ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200102000-00008

    authors: Laurent S,Elst LV,Copoix F,Muller RN

    更新日期:2001-02-01 00:00:00

  • Magnetic resonance imaging-controlled laser-induced interstitial thermotherapy.

    abstract:RATIONALE AND OBJECTIVES:Laser-induced interstitial thermotherapy (LITT) may become an attractive modality for minimally invasive tumor therapy. Magnetic resonance imaging (MRI) could be used to assist this procedure. METHODS:A T1-weighted turbo fast low-angle shot (FLASH) sequence for on-line monitoring of the laser-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199403000-00015

    authors: Gewiese B,Beuthan J,Fobbe F,Stiller D,Müller G,Böse-Landgraf J,Wolf KJ,Deimling M

    更新日期:1994-03-01 00:00:00

  • Free-breathing three-dimensional computed tomography of the lung using prospective respiratory gating: charge-coupled device camera and laser sensor device in an animal experiment.

    abstract:PURPOSE:The aim was to investigate the feasibility and image quality of prospective respiratory gating for 3-D computed tomography (CT) of the lung. MATERIAL AND METHODS:Eight anesthetized pigs underwent prospectively gated multidetector computed tomography using 2 devices: a charge-coupled device (CCD) camera and a l...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000208926.98693.b6

    authors: Zaporozhan J,Ley S,Unterhinninghofen R,Saito Y,Fabel-Schulte M,Keller S,Szabo G,Kauczor HU

    更新日期:2006-05-01 00:00:00

  • Patient choice and nonionic contrast media.

    abstract:RATIONALE AND OBJECTIVES:Because of the greatly increased cost of nonionic, low-osmolar contrast material, some practitioners reserve its use for patients at high risk for an adverse contrast reaction. The authors attempt to evaluate the proportion of low-risk outpatients--when offered a choice between the more expensi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199304000-00008

    authors: Hopper KD,Matthews YL

    更新日期:1993-04-01 00:00:00

  • The biliary and urinary excretion of sodium tyropanoate and sodium ipodate in dogs: pharmacokinetics, influence of bile salts and choleretic effects with comparison to iopanoic acid.

    abstract::The biliary and urinary excretion of sodium tyropanoate (Bilopaque) and sodium ipodate (Oragrafin) were studied in unanesthetized bile-fistula dogs using stepwise, increasing, intravenous infusions of the contrast materials. A constant intravenous infusion of sodium taurocholate was administered at the rate of either ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197701000-00017

    authors: Berk RN,Loeb PM,Cobo-Frenkel A,Barnhart JL

    更新日期:1977-01-01 00:00:00

  • The clotting issue: etiologic factors in thromboembolism. II. Clinical considerations.

    abstract:RATIONALE AND OBJECTIVES:The authors analyze the origins of the "clotting issue," the controversy that began in the 1980s when contrast media, once perceived as good flushing agents for catheters because of their assumed anticoagulant properties, came under attack for allegedly causing thromboembolism. Laboratory studi...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:

    authors: Dawson P,Cousins C,Bradshaw A

    更新日期:1993-11-01 00:00:00

  • Effects of angiographic needle size and subsequent catheter insertion on arterial walls. An in vitro experiment in human cadavers.

    abstract:RATIONALE AND OBJECTIVES:It is widely believed that down-sizing catheters, and possibly needles, will decrease damage to the entry vessel in the performance of angiography. The purposes of this in vitro experiment are to determine if smaller needles produce less arterial wall damage than larger needles and to assess th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00001

    authors: Smith DC,Hamlin JA,Jensen DA,Pappas JM,Westengard JC,Saukel GW

    更新日期:1992-10-01 00:00:00

  • Low-osmolality contrast media-induced ventricular fibrillation.

    abstract::We evaluated the incidence of ventricular fibrillation with low-osmolality contrast media by right coronary arteriography in eleven adult mongrel dogs. Following insertion of the catheter into the right coronary artery, a test solution was infused for 25 seconds (total 11 mL) or until fibrillation occurred. The test s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198904000-00008

    authors: Hayakawa K,Yamashita K

    更新日期:1989-04-01 00:00:00

  • Contrast media tonicity. Part I. Effects upon IV-DSA time-concentration curve peak and width: experimental studies.

    abstract::Prior to the formation of an intravenous digital subtraction angiography (IV-DSA) image, contrast medium passes through the lesser circulation and is diluted by the blood volume of the heart and lungs. If the contrast medium alone influences central blood volume or cardiac output, the shape of the resultant time-conce...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198603000-00009

    authors: Burbank FH,Thompson WM

    更新日期:1986-03-01 00:00:00

  • Observation on the metabolism of iopanoyl (Telepaque) glucuronide in dogs treated with antibiotics.

    abstract::The purpose of our investigation was to determine whether iopanoyl glucuronide, the major metabolite of iopanoic acid (Telepaque), undergoes hydrolysis by bacterial beta-glucuronidase in dogs. The conjugated compound was identified and quantitated by elemental analysis, fluorescent excitation analysis, thin-layer chro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197805000-00011

    authors: Thoeni RF,Goldberg HI,Moss AA,Lin SK,Brito AC

    更新日期:1978-05-01 00:00:00

  • Fluorinated blood substitute retention in the rat measured by fluorine-19 magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199208000-00012

    authors: Meyer KL,Carvlin MJ,Mukherji B,Sloviter HA,Joseph PM

    更新日期:1992-08-01 00:00:00

  • A method for the study of regional ischemic dysfunction in the intact dog. Permanent endocardial markers and the pressure-length loop.

    abstract::A radiographic method for use in the closed-chest dog is described which allows the quantitation of segmental mechanical performance. Previous work has shown that the area of the pressure-length loop (an approximation of a stress-strain integral) is a useful measure of the mechanical work performed by a segment of myo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197611000-00010

    authors: Ringertz HG,Carlsson E,Tyberg JV

    更新日期:1976-11-01 00:00:00

  • First-in-Human Ultrasound Molecular Imaging With a VEGFR2-Specific Ultrasound Molecular Contrast Agent (BR55) in Prostate Cancer: A Safety and Feasibility Pilot Study.

    abstract:OBJECTIVE:BR55, a vascular endothelial growth factor receptor 2 (VEGFR2)-specific ultrasound molecular contrast agent (MCA), has shown promising results in multiple preclinical models regarding cancer imaging. In this first-in-human, phase 0, exploratory study, we investigated the feasibility and safety of the MCA for ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000362

    authors: Smeenge M,Tranquart F,Mannaerts CK,de Reijke TM,van de Vijver MJ,Laguna MP,Pochon S,de la Rosette JJMCH,Wijkstra H

    更新日期:2017-07-01 00:00:00

  • Noninvasive measurement of an index of renal blood flow.

    abstract::A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198307000-00009

    authors: Powers TA,Rees RS,Bowen RD

    更新日期:1983-07-01 00:00:00

  • Relative carotid blood flow measurements in dogs by high-speed CT. A preliminary study.

    abstract::A high-speed computed tomography (CT) scanner was used for measuring flow in a phantom and in the common carotid arteries of six dogs. The general ability of the scanner to assess flow using contrast media boluses was tested with the phantom. The validated simple concept was then used in the animals. The carotid blood...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198712000-00008

    authors: Ringertz HG,Jaschke W,Sievers R,Lipton MJ

    更新日期:1987-12-01 00:00:00

  • Facilitated Diagnosis of Pneumothoraces in Newborn Mice Using X-ray Dark-Field Radiography.

    abstract:OBJECTIVE:The aim of this study was to evaluate the diagnostic value of x-ray dark-field imaging in projection radiography-based depiction of pneumothoraces in the neonatal murine lung, a potentially life-threatening medical condition that requires a timely and correct diagnosis. MATERIALS AND METHODS:By the use of a ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000285

    authors: Hellbach K,Yaroshenko A,Willer K,Pritzke T,Baumann A,Hesse N,Auweter S,Reiser MF,Eickelberg O,Pfeiffer F,Hilgendorff A,Meinel FG

    更新日期:2016-10-01 00:00:00

  • Photon scattering measurement of calcaneal bone density: result of in vivo cross-sectional studies.

    abstract::The density of trabecular bone in the os calcis has been measured in 321 subjects using a gamma ray scattering technique. In normal subjects it was shown that density could be predicted from body weight and age with a standard error of 5.6%. It was also shown that the dependence of density upon weight and age was the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198201000-00004

    authors: Roberts JG,DiTomasso E,Webber CE

    更新日期:1982-01-01 00:00:00

  • Nonionic contrast media iohexol and iomeprol decrease renal arterial tone: comparative studies on human and porcine isolated vascular segments.

    abstract:RATIONALE AND OBJECTIVES:The vasoconstriction of the renal arteries is frequently considered as a crucial factor for radiocontrast-induced nephropathy. A direct effect of iodinated radiographic contrast medium (RCM) on vascular smooth muscle is supposed to be one component of the vascular response. We studied the effec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200208000-00005

    authors: Uder M,Humke U,Pahl M,Jansen A,Utz J,Kramann B

    更新日期:2002-08-01 00:00:00

  • Preclinical profile of the monodisperse iodinated macromolecular blood pool agent P743.

    abstract:RATIONALE AND OBJECTIVES:To summarize the chemical synthesis, physicochemical characterization, pharmacokinetic behavior, and biological evaluation of P743, a new macromolecular iodinated contrast medium. METHODS:The synthesis and molecular modeling of the iodinated macromolecule P743 are described. The pharmacokineti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200101000-00006

    authors: Idée JM,Port M,Robert P,Raynal I,Prigent P,Dencausse A,Le Greneur S,Tichkowsky I,Le Lem G,Bourrinet P,Mugel T,Benderbous S,Devoldere L,Bourbouze R,Meyer D,Bonnemain B,Corot C

    更新日期:2001-01-01 00:00:00

  • Dynamic contrast-enhanced computed tomography as a potential biomarker in patients with metastatic renal cell carcinoma: preliminary results from the Danish Renal Cancer Group Study-1.

    abstract:OBJECTIVES:The aim of this study was to explore the impact of dynamic contrast-enhanced (DCE) computer tomography (CT) as a biomarker in metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS:Twelve patients with favorable or intermediate Memorial Sloan Kettering Cancer Center risk group and clear cell mRCC par...

    journal_title:Investigative radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/RLI.0000000000000058

    authors: Mains JR,Donskov F,Pedersen EM,Madsen HH,Rasmussen F

    更新日期:2014-09-01 00:00:00

  • Characterization of radial forces in Z stents.

    abstract:RATIONAL AND OBJECTIVES:The purpose of this study was to evaluate the effects of variation in design parameters on the resultant radial force. We evaluated the influence of wire gauge, leg length, and number of bends on the radial force produced by z stents and compared these with radial forces produced by commercial s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200109000-00004

    authors: Snowhill PB,Nosher JL,Siegel RL,Silver FH

    更新日期:2001-09-01 00:00:00

  • Dynamic contrast-enhanced ultrasound for assessment of skeletal muscle microcirculation in peripheral arterial disease.

    abstract:OBJECTIVE:: This feasibility study was performed to assess whether dynamic contrast-enhanced ultrasound (CEUS) and transient arterial occlusion are able to detect alterations in the microvascular perfusion and arterial perfusion reserve in patients suffering from peripheral arterial disease (PAD) in comparison with hea...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182183a77

    authors: Amarteifio E,Weber MA,Wormsbecher S,Demirel S,Krakowski-Roosen H,Jöres A,Braun S,Delorme S,Böckler D,Kauczor HU,Krix M

    更新日期:2011-08-01 00:00:00

  • Targeted-microbubble binding selectively to GPIIb IIIa receptors of platelet thrombi.

    abstract:RATIONALE AND OBJECTIVES:New targeted microbubbles directed to the GPIIb IIIa receptor have been developed. The objective was to determine whether targeting microbubbles to clots would enhance ultrasound imaging. Systematic studies were designed to determine whether in vitro methodology is an acceptable predictor of in...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200211000-00001

    authors: Schumann PA,Christiansen JP,Quigley RM,McCreery TP,Sweitzer RH,Unger EC,Lindner JR,Matsunaga TO

    更新日期:2002-11-01 00:00:00

  • Segmentation-based attenuation correction in positron emission tomography/magnetic resonance: erroneous tissue identification and its impact on positron emission tomography interpretation.

    abstract:OBJECTIVES:The objective of this study was to evaluate the frequency and characteristics of artifacts in segmentation-based attenuation correction maps (μ-maps) of positron emission tomography/magnetic resonance (PET/MR) and their impact on PET interpretation and the standardized uptake value (SUV) quantification in no...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000131

    authors: Brendle C,Schmidt H,Oergel A,Bezrukov I,Mueller M,Schraml C,Pfannenberg C,la Fougère C,Nikolaou K,Schwenzer N

    更新日期:2015-05-01 00:00:00

  • Intrapulmonary 3He gas distribution depending on bolus size and temporal bolus placement.

    abstract:OBJECTIVE:Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on insp...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181690111

    authors: Gast KK,Hawig K,Windirsch M,Markstaller K,Schreiber WG,Schmiedeskamp J,Düber C,Kauczor HU,Heussel CP

    更新日期:2008-06-01 00:00:00

  • Assessment of preoperative magnetic resonance imaging staging in patients with hepatocellular carcinoma undergoing resection compared with the seventh American Joint Committee on Cancer System.

    abstract:OBJECTIVES:The aim of this study was to compare the prognostic utility of a staging system using magnetic resonance imaging (MRI) with the seventh American Joint Committee on Cancer (AJCC) staging system in patients with hepatocellular carcinoma (HCC) who underwent hepatic resection. MATERIALS AND METHODS:A total of 1...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182630e8d

    authors: An C,Choi GH,Lee HS,Kim MJ

    更新日期:2012-11-01 00:00:00

  • Alteration of human tumor cell adhesion by high-strength static magnetic fields.

    abstract:RATIONALE AND OBJECTIVES:The authors investigated whether the ability of human malignant melanoma cells to increase in cell number or their ability to remain viable was compromised by high-field strength static magnetic fields. Normal human fibroblasts also were studied to determine if any magnetic field-related altera...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00014

    authors: Short WO,Goodwill L,Taylor CW,Job C,Arthur ME,Cress AE

    更新日期:1992-10-01 00:00:00

  • Microangiographic anatomy of the cat's eye.

    abstract::The microangiographic anatomy of the cat's eye is presented. The characteristic vascular pattern of each of the three distinct circulations, retinal choroidal, and ciliary is described and illustrated. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197501000-00007

    authors: Rothman SL,Kier EL,Deuker DK

    更新日期:1975-01-01 00:00:00

  • Gelatin encapsulated nitrogen microbubbles as ultrasonic contrast agents.

    abstract::Gelatin encapsulated nitrogen microbubbles were effective ultrasonic contrast agents in in vitro phantom and in vivo rabbit V2 carcinoma studies. Intra-arterial injection of 80-micrometer gelatin encapsulated nitrogen microbubbles appeared to improve tumor visualization by rim enhancement, which persisted for several ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198005000-00013

    authors: Carroll BA,Turner RJ,Tickner EG,Boyle DB,Young SW

    更新日期:1980-05-01 00:00:00

  • Analysis of radiocontrast-induced nephropathy by dual-labeled radionuclide clearance.

    abstract:RATIONALE AND OBJECTIVES:This study was devised to develop a method of measuring the acute effects of radiocontrast media on renal function and assessing the relationship of the dose of radiocontrast media infused with the incidence of radiocontrast-induced renal failure. In addition, the drug adenosine phosphate-magne...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-199406000-00004

    authors: Albert SG,Shapiro MJ,Brown WW,Goodgold H,Zuckerman D,Durham R,Kern M,Fletcher J,Wolverson M,Plummer ES

    更新日期:1994-06-01 00:00:00