The clotting issue: etiologic factors in thromboembolism. II. Clinical considerations.

Abstract:

RATIONALE AND OBJECTIVES:The authors analyze the origins of the "clotting issue," the controversy that began in the 1980s when contrast media, once perceived as good flushing agents for catheters because of their assumed anticoagulant properties, came under attack for allegedly causing thromboembolism. Laboratory studies as well as a number of clinical reports seemed to substantiate this charge. Nonionic agents in particular were accused by some clinicians of being more likely to cause clots to form in syringes contaminated with blood than were ionic agents. The authors wanted to determine whether some lapse in operator technique rather than a fault in the contrast agent might be to blame. The theory that the syringe and catheter materials, and not the contrast agent itself, could be the source of thromboembolic problems in angiography also is examined. METHODS:The authors reviewed studies and reports on both sides of the issue and conducted laboratory and clinical studies of their own. For the syringe materials analysis, they used a fibrinopeptide A (FpA) enzyme-linked immunosorbent assay (ELISA) test to monitor levels as a marker of activation of coagulation. They tested catheter materials using the same technique. RESULTS:Clots were found only in nonionic agents, but under nonclinically relevant circumstances. If the anticoagulant effect of the nonionic contrast agent was maximized by mixing rather than layering blood and agent, clots did not form. In their materials analysis, the authors demonstrated that glass syringes are thrombogenic, causing vigorous contact activation, and that plastic is less so. Polyurethane catheters are more thrombogenic, polyethylene less so. One survey conducted in the 1970s on the clinical incidence of thromboembolism in coronary angiography suggested that the single most important factor in the etiology is poor angiographic technique. The authors' studies supported their thesis. CONCLUSIONS:In terms of the findings from laboratory studies, misinterpretation of data by nonclinicians is one problem. No evidence suggests that nonionic contrast agents are in any way prothrombotic or thrombogenic. On the contrary, in line with their greater inertness, nonionic agents have weaker effects. Ionic contrast media may cause more endothelial injury and associated localized platelet deposition than nonionic contrast media, and more anticoagulant contrast agents are more toxic. If anticoagulation is required, therefore, it should be achieved by such procedures as carefully controlled systemic heparinization rather than by resorting to more toxic materials. The activation of coagulation is caused by endothelial injury and by prolonged contact between blood and foreign surfaces such as syringes or catheters, but is inhibited by the contrast agent. Because a thrombus may form inside the catheter, whatever contrast agent is used, flushing is important. The authors agree with the findings of one study that the incidence of thromboembolism in coronary angiography, and probably in other catheter procedures, is markedly operator dependent. The materials of the syringes and catheters used, as well as the state of the patient's intrinsic clotting, are more important factors than the contrast agent. The authors conclude that materials other than the contrast agents are the cause of thromboembolic problems; and that, being anticoagulant, contrast agents are entirely helpful, if variably so, in angiographic procedures.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Dawson P,Cousins C,Bradshaw A

subject

Has Abstract

pub_date

1993-11-01 00:00:00

pages

S31-6; discussion S37-8

eissn

0020-9996

issn

1536-0210

journal_volume

28 Suppl 5

pub_type

杂志文章,评审
  • Magnetic resonance imaging of the cerebral aqueduct. Signal intensity time curves demonstrated by fast acquisition with multiple excitation (FAME).

    abstract::Using cardiac-gated fast acquisition with multiple excitation (FAME), time curves of the cerebral aqueduct signals were derived in 19 healthy volunteers and 14 patients. A mean curve of the normal subjects was determined during systole. A relatively stable point of time was found at 270 msec after the R-wave supposed ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198911000-00004

    authors: van den Hout JH,Bakker CJ,Mali WP,van Dijk P,Faber JA,Feldberg MA,Gooskens RH,Witkamp TD

    更新日期:1989-11-01 00:00:00

  • Investigation of 125I as an isotopic source for mammography.

    abstract::An isotopic radiation source 125I was investigated for use in soft tissue radiaography, with particular attention to possible use in mammography for mass screening. Film sensitivities, exposure rates, absorbed doeses, contrast and resolution were determined, and compared to conventional x-ray units. It was found that ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197509000-00007

    authors: Fairchild R,Atkins HL,Lebowitz E,Greenberg D

    更新日期:1975-09-01 00:00:00

  • Assessment of preoperative magnetic resonance imaging staging in patients with hepatocellular carcinoma undergoing resection compared with the seventh American Joint Committee on Cancer System.

    abstract:OBJECTIVES:The aim of this study was to compare the prognostic utility of a staging system using magnetic resonance imaging (MRI) with the seventh American Joint Committee on Cancer (AJCC) staging system in patients with hepatocellular carcinoma (HCC) who underwent hepatic resection. MATERIALS AND METHODS:A total of 1...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182630e8d

    authors: An C,Choi GH,Lee HS,Kim MJ

    更新日期:2012-11-01 00:00:00

  • Intrapulmonary 3He gas distribution depending on bolus size and temporal bolus placement.

    abstract:OBJECTIVE:Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on insp...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181690111

    authors: Gast KK,Hawig K,Windirsch M,Markstaller K,Schreiber WG,Schmiedeskamp J,Düber C,Kauczor HU,Heussel CP

    更新日期:2008-06-01 00:00:00

  • Pharmacokinetics and safety of gadobutrol-enhanced magnetic resonance imaging in pediatric patients.

    abstract:OBJECTIVES:This clinical study investigated the pharmacokinetics and safety of gadobutrol, a magnetic resonance (MR) imaging extracellular contrast agent, in pediatric patients aged 2 to 17 years. MATERIALS AND METHODS:In this open-label, multicenter study, patients scheduled for routine contrast-enhanced MR imaging o...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181bfe2d2

    authors: Hahn G,Sorge I,Gruhn B,Glutig K,Hirsch W,Bhargava R,Furtner J,Born M,Schröder C,Ahlström H,Kaiser S,Moritz JD,Kunze CW,Shroff M,Stokland E,Trnkova ZJ,Schultze-Mosgau M,Reif S,Bacher-Stier C,Mentzel HJ

    更新日期:2009-12-01 00:00:00

  • Changes in complement and coagulation factors in a patient suffering a severe anaphylactoid reaction to injected contrast material: some considerations of pathogenesis.

    abstract::A patient, suffering a severe anaphylactoid reaction to contrast material injected for an intravenous pyelogram, developed a consumption coagulopathy and evidence of complement activation. Precontrast complement values suggested that the patient had been processing complement via the classical pathway, perhaps as a co...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00004

    authors: Lasser EC,Lang JH,Lyon SG,Hamblin AE

    更新日期:1980-11-01 00:00:00

  • Specific absorption rate as a poor indicator of magnetic resonance-related implant heating.

    abstract::Recent publications of the magnetic resonance safety profile of neurostimulators, cardiac pacemakers, and other implanted devices imply that these devices are no longer a contraindication for magnetic resonance imaging. It is very promising that patients who have these implanted devices may in the future no longer be ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000185898.59140.91

    authors: Nitz WR,Brinker G,Diehl D,Frese G

    更新日期:2005-12-01 00:00:00

  • Technical feasibility and performance studies of a 0.009-inch nitinol microguidewire for potential neuroendovascular applications.

    abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199704000-00008

    authors: Putman CM,Chaloupka JC,Kailasnath P,Alderman J

    更新日期:1997-04-01 00:00:00

  • Development of echogenic, plasmid-incorporated, tissue-targeted cationic liposomes that can be used for directed gene delivery.

    abstract:RATIONALE AND OBJECTIVES:Echogenic antibody-conjugated anionic liposomes have been developed that allow directed tissue targeting and acoustic enhancement. These are not efficient for gene delivery. A cationic formulation that allows directed gene delivery while retaining acoustic properties may provide more efficient ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200012000-00007

    authors: Tiukinhoy SD,Mahowald ME,Shively VP,Nagaraj A,Kane BJ,Klegerman ME,MacDonald RC,McPherson DD,Matsumura JS

    更新日期:2000-12-01 00:00:00

  • Keratinization and necrosis. Morphologic aspects of lymphatic metastases in ultrasound.

    abstract:RATIONALE AND OBJECTIVE:The authors performed a retrospective study in ultrasound to investigate new aspects in the sonomorphology of lymph node metastases of the neck. In this study, it could be demonstrated the first time that the histologic characteristics of the metastases determine the sonographic appearance. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199609000-00001

    authors: Mäurer J,Willam C,Steinkamp HJ,Knollmann FD,Felix R

    更新日期:1996-09-01 00:00:00

  • Impact of Impaired Renal Function on Gadolinium Retention After Administration of Gadolinium-Based Contrast Agents in a Mouse Model.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact of impaired renal function on gadolinium (Gd) retention in various organs after Gd-based contrast agent injection. MATERIALS AND METHODS:After local animal care and review committee approval, 23 normal mice and 26 with renal failure were divided into 4 tre...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000295

    authors: Kartamihardja AA,Nakajima T,Kameo S,Koyama H,Tsushima Y

    更新日期:2016-10-01 00:00:00

  • The effect of some iodinated contrast media on human plasma butyrylcholinesterase activity.

    abstract::The effect of three iodinated contrast media (CM) on human plasma butyrylcholinesterase (BuChE) activity was studied during the intravenous pyelography (i.v.P). BuChE is an enzyme that participates in the metabolism of acetylcholine and hydrolyzes food esters and drugs such as nondepolarizing muscle relaxants and loca...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199805000-00008

    authors: Mironidou M,Ximitidou O,Christopoulos S,Kokkas B

    更新日期:1998-05-01 00:00:00

  • Polycystic kidney disease evaluation by magnetic resonance imaging in ischemia-reperfusion injured PKD1 knockout mouse model: comparison of T2-weighted FSE and true-FISP.

    abstract:OBJECTIVE:To investigate the efficacy of true fast imaging with steady state precession (true-FISP) compared with T2-weighted fast spin echo (T2W-FSE) in monitoring changes in cyst volume and renal expansion in an ischemia reperfusion (IR) injured PKD1 knockout (IKO) mouse model. MATERIALS AND METHODS:The animal study...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181be3501

    authors: Zhou X,Bao H,Takakura A,Zhou J,Albert M,Sun Y

    更新日期:2010-01-01 00:00:00

  • Detection of emphysema with computed tomography. Correlation with pulmonary function tests and chest radiography.

    abstract::We studied 60 male patients who had concurrent chest films (CXR), computed tomography scans (CT) and pulmonary function tests (PFT) to assess the sensitivity of CT and conventional films in detecting emphysema compared with PFT. We also sought to determine whether emphysema could be diagnosed by CT in patients with no...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198804000-00004

    authors: Sanders C,Nath PH,Bailey WC

    更新日期:1988-04-01 00:00:00

  • Comparison of the Relaxivities of Macrocyclic Gadolinium-Based Contrast Agents in Human Plasma at 1.5, 3, and 7 T, and Blood at 3 T.

    abstract:PURPOSE:The relaxivities of 3 macrocyclic gadolinium-based contrast agents (GBCAs) were determined in human plasma and blood under standardized and clinically relevant laboratory conditions. METHODS:The T1 relaxivity, r1, was determined in human plasma at 1.5, 3, and 7 T, and in human blood at 3 T at 37°C in phantoms ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000577

    authors: Szomolanyi P,Rohrer M,Frenzel T,Noebauer-Huhmann IM,Jost G,Endrikat J,Trattnig S,Pietsch H

    更新日期:2019-09-01 00:00:00

  • Normal renal blood flow measurement using phase-contrast cine magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:This study assesses the ability of a cardiac-gated phase-contrast magnetic resonance imaging (MRI) technique to measure renal blood flow (RBF) noninvasively in humans. METHODS:In nine normal volunteers, total RBF in the renal arteries and in the left renal vein was estimated by MRI and correla...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199206000-00012

    authors: Sommer G,Noorbehesht B,Pelc N,Jamison R,Pinevich AJ,Newton L,Myers B

    更新日期:1992-06-01 00:00:00

  • Ioversol clinical safety summary.

    abstract::The authors evaluated double-blind comparative and open-label clinical trials in 1,186 patients who received ioversol to evaluate the safety and efficacy of ioversol, a new nonionic low-osmolality contrast medium, at iodine concentrations of 32%, 24%, and 16%. The results indicate that ioversol was well tolerated in a...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198906001-00020

    authors: Benamor M,Aten EM,McElvany KD,Lankin DG,James MA,Buy-Gandal T,Harashe LT,Weinandt WJ

    更新日期:1989-06-01 00:00:00

  • Incidence and methods of diagnosis of musculoskeletal injuries incurred in Operations Desert Shield and Desert Storm.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the incidence and distribution of orthopedic injuries sustained in Operation Desert Shield and Desert Storm by evaluating whether existing diagnostic imaging modalities were sufficient to diagnose the types of musculoskeletal injuries incurred. The authors also sought to det...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199703000-00006

    authors: Truax AL,Chandnani VP,Chacko AK,Gonzalez DM

    更新日期:1997-03-01 00:00:00

  • Characterization of radial forces in Z stents.

    abstract:RATIONAL AND OBJECTIVES:The purpose of this study was to evaluate the effects of variation in design parameters on the resultant radial force. We evaluated the influence of wire gauge, leg length, and number of bends on the radial force produced by z stents and compared these with radial forces produced by commercial s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200109000-00004

    authors: Snowhill PB,Nosher JL,Siegel RL,Silver FH

    更新日期:2001-09-01 00:00:00

  • Radioimmunodetection of a transplantable human bladder carcinoma in a nude mouse.

    abstract::The results of an in vitro mixed hemadsorption (MHA) assay predicted the success of in vivo tumor localization using a radioiodinated, monoclonal, IgG1 antibody (A2) with reactivity to the human bladder carcinoma cell line RT4. In vitro, murine monoclonal antibodies A2 and G6, demonstrated reactivity to RT4 with titer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198411000-00011

    authors: Gross MD,Skinner RW,Grossman HB

    更新日期:1984-11-01 00:00:00

  • Experimental pulmonary arteritis.

    abstract::Experimental pulmonary arteritis was produced in rabbits by intravenous injection of alveolar macrophages from donor rabbits. These animals, along with matched controls, were studied with pulmonary angiography to test the hypothesis that angiography could detect the vasculitic process in life. The animals were then sa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198007000-00005

    authors: Hicken P,Hogg JC,Pare PD

    更新日期:1980-07-01 00:00:00

  • Optimal injection protocol for CT evaluation during hepatic arterial infusion chemotherapy.

    abstract:OBJECTIVE:As an imaging modality for follow-up during continuous or repeated hepatic arterial infusion chemotherapy using a hepatic intra-arterial indwelling catheter, the usefulness of CT while infusing contrast through the indwelling catheter (reservoir port) was examined. METHODS:Using reservoir ports implanted in ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199912000-00003

    authors: Morimoto M,Satake M,Sekiguchi R,Haruno M,Moriyama N

    更新日期:1999-12-01 00:00:00

  • Combined methods for assessment of neurotoxicity: testing of new nonionic radiographic media.

    abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00053

    authors: Sovak M,Siefert HM,Ranganathan R

    更新日期:1980-11-01 00:00:00

  • Differentiation of delayed kidney graft function with gadolinium-DTPA-enhanced magnetic resonance imaging and Doppler ultrasound.

    abstract:RATIONALE AND OBJECTIVES:The authors differentiate acute tubular necrosis from transplant rejection in patients with delayed kidney graft function using gadolinium (Gd)-DTPA enhanced magnetic resonance (MR) imaging. METHODS:Twenty-four patients after renal transplantation (10 with normal graft function, 14 with delaye...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-199606000-00009

    authors: Preidler KW,Szolar D,Schreyer H,Ebner F,Kern R,Holzer H,Horina JH

    更新日期:1996-06-01 00:00:00

  • Nonionic contrast media iohexol and iomeprol decrease renal arterial tone: comparative studies on human and porcine isolated vascular segments.

    abstract:RATIONALE AND OBJECTIVES:The vasoconstriction of the renal arteries is frequently considered as a crucial factor for radiocontrast-induced nephropathy. A direct effect of iodinated radiographic contrast medium (RCM) on vascular smooth muscle is supposed to be one component of the vascular response. We studied the effec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200208000-00005

    authors: Uder M,Humke U,Pahl M,Jansen A,Utz J,Kramann B

    更新日期:2002-08-01 00:00:00

  • Noninvasive inductive stent heating: alternative approach to prevent instent restenosis?

    abstract:RATIONALE AND OBJECTIVES:To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. METHODS:Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000117881.42422.72

    authors: Floren MG,Günther RW,Schmitz-Rode T

    更新日期:2004-05-01 00:00:00

  • Multishot targeted PROPELLER magnetic resonance imaging: description of the technique and initial applications.

    abstract:OBJECTIVES:To test the feasibility of combining inner-volume imaging (IVI) techniques with conventional multishot periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) techniques for targeted-PROPELLER magnetic resonance imaging. MATERIALS AND METHODS:Perpendicular section-selective ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181a8b015

    authors: Deng J,Larson AC

    更新日期:2009-08-01 00:00:00

  • Dual source dual energy MDCT: comparison of 80 kVp and weighted average 120 kVp data for conspicuity of hypo-vascular liver metastases.

    abstract:PURPOSE:To determine whether liver metastases conspicuity is improved at 80 kVp when compared with weighted average (WA) simulated 120 kVp data using dual source dual energy CT. METHODS:A total of 11 patients with 44 hypo-vascular liver metastases underwent contrast enhanced Dual Energy CT (DECT). In all cases the sub...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181dfda78

    authors: Robinson E,Babb J,Chandarana H,Macari M

    更新日期:2010-07-01 00:00:00

  • Identifying tumor vascular permeability heterogeneity with magnetic resonance imaging contrast agents.

    abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200204000-00003

    authors: Aref M,Brechbiel M,Wiener EC

    更新日期:2002-04-01 00:00:00

  • Accuracy of ultrasound in fetal femur length determination. Ultrasound phantom study.

    abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00016

    authors: Gamba JL,Bowie JD,Dodson WC,Hedlund LW

    更新日期:1985-05-01 00:00:00