Magnetic resonance imaging of the cerebral aqueduct. Signal intensity time curves demonstrated by fast acquisition with multiple excitation (FAME).

Abstract:

:Using cardiac-gated fast acquisition with multiple excitation (FAME), time curves of the cerebral aqueduct signals were derived in 19 healthy volunteers and 14 patients. A mean curve of the normal subjects was determined during systole. A relatively stable point of time was found at 270 msec after the R-wave supposed to be the reversal of the flow of cerebral-spinal fluid in the aqueduct. Different curves were noticed in complete aqueductal obstruction (n = 2); in other pathologic states, such as cerebral tumor (n = 3), normal pressure hydrocephalus (n = 3), and brain atrophy (n = 1), no different signal time curves were observed. Parameters such as aqueduct diameter, cerebro-spinal fluid volume and brain compliance are probably other important factors in aqueduct liquor flow.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

van den Hout JH,Bakker CJ,Mali WP,van Dijk P,Faber JA,Feldberg MA,Gooskens RH,Witkamp TD

doi

10.1097/00004424-198911000-00004

subject

Has Abstract

pub_date

1989-11-01 00:00:00

pages

855-60

issue

11

eissn

0020-9996

issn

1536-0210

journal_volume

24

pub_type

杂志文章
  • Ultrasound bone velocity on proximal phalanges in premenopausal, perimenopausal, and postmenopausal healthy women.

    abstract:RATIONALE AND OBJECTIVES:The authors studied premenopausal, perimenopausal, and postmenopausal women to determine if ultrasound bone velocity (UBV) on proximal phalanges of women reflect bone changes related to gonadal status and age. METHODS:A total of 166 healthy women-64 postmenopausal women (mean age 58.7 +/- 9.4 ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199701000-00011

    authors: Aguado F,Revilla M,Hernández ER,Villa LF,Rico H

    更新日期:1997-01-01 00:00:00

  • Magnetization transfer and high-dose contrast in early brain infection on magnetic resonance.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the effect of contrast dose, use of magnetization transfer (MT), and temporal delay on the visualization of contrast enhancement with gadoteridol (Gd HP-DO3A) in a canine brain abscess model. METHODS:Alpha streptococcus brain abscesses were studied in five dogs at 1.5 tesla...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199503000-00001

    authors: Runge VM,Wells JW,Kirsch JE

    更新日期:1995-03-01 00:00:00

  • Mixing problems of low flow hepatic artery infusion. Improvement with small caliber double lumen balloon catheters.

    abstract::The problem of inhomogeneous mixing encountered during hepatic artery (HA) chemotherapy infusion was assessed and a practical solution examined. A glass model of the human HA distribution was used to determine mixing homogeneity of low flow (1.4 mL/minute) dye infusion into pulsatile flow (280-300 mL/minute) of a flui...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198807000-00007

    authors: Barth KH,Lutz RJ,Kremers PW,Miller DL

    更新日期:1988-07-01 00:00:00

  • Observer variation in detecting the radiologic features associated with bronchiolitis.

    abstract::Chest radiographs are commonly obtained to assess children for bronchiolitis, both to corroborate the diagnosis and to exclude other diagnostic possibilities. Their utility in this setting has not previously been examined. Using a blinded, randomized study design, we examined the interobserver and intraobserver variat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199102000-00004

    authors: Coblentz CL,Babcook CJ,Alton D,Riley BJ,Norman G

    更新日期:1991-02-01 00:00:00

  • Activities of the Conjoint Committee. Enhancement of diagnostic radiologic research and education.

    abstract::Even though we have made much progress over the last decade, much still needs to be done. I am personally very pleased with the excellent management and authority of my coauthor, Joe Frank, in assuming the Acting Directorship of our DRRP. You will be hearing more from him in the immediate future about this research pr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199304001-00014

    authors: Putman CE,Frank JA

    更新日期:1993-04-01 00:00:00

  • Fibroblast response to gadolinium: role for platelet-derived growth factor receptor.

    abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e943d2

    authors: Bhagavathula N,Dame MK,DaSilva M,Jenkins W,Aslam MN,Perone P,Varani J

    更新日期:2010-12-01 00:00:00

  • Solid, part-solid, or non-solid?: classification of pulmonary nodules in low-dose chest computed tomography by a computer-aided diagnosis system.

    abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/RLI.0000000000000121

    authors: Jacobs C,van Rikxoort EM,Scholten ET,de Jong PA,Prokop M,Schaefer-Prokop C,van Ginneken B

    更新日期:2015-03-01 00:00:00

  • Preliminary evaluation of Hexabrix for temporomandibular joint arthrography.

    abstract::A double-blind randomized study of ten patients compared Hexabrix 32% to Renografin-60 in TMJ arthrography. Equivalent volumes of contrast material were injected under fluoroscopic observation, with film quality and patient subjective response graded independently by three radiologists. In immediate arthrogram quality...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00032

    authors: Katzberg RW

    更新日期:1984-11-01 00:00:00

  • Saturation kinetics of iopanoate in dogs with an intact enterohepatic circulation. Before and after phenobarbital induction.

    abstract::Capacity-limited elimination of sodium iopanoate and a reproducible apparent transport maximum (Tm) were demonstrated in nonoperated dogs having an intact enterohepatic circulation and normal endogenous bile salt pool. Using a multiple infusion technique, estimation of apparent Tm of iopanoate in the liver was possibl...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197601000-00007

    authors: Herzog RJ,Nelson JA,Staubus AE

    更新日期:1976-01-01 00:00:00

  • Consistency of rotator-cuff calcifications. Observations on plain radiography, sonography, computed tomography, and at needle treatment.

    abstract:RATIONALE AND OBJECTIVES:The author analyzes findings of consistency of rotator-cuff calcifications found at ultrasound (US)-guided needle treatment compared with findings of plain radiography, US, and computed tomography (CT). METHODS:Twenty patients had rotator-cuff calcifications (mean diameter, 1.5 cm; range, 1.1-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199605000-00010

    authors: Farin PU

    更新日期:1996-05-01 00:00:00

  • Attenuation correction for flexible magnetic resonance coils in combined magnetic resonance/positron emission tomography imaging.

    abstract:INTRODUCTION:Attenuation correction for magnetic resonance (MR) coils is a new challenge that came about with the development of combined MR and positron emission tomography (PET) imaging. This task is difficult because such coils are not directly visible on either PET or MR acquisitions with current combined scanners ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a530f8

    authors: Eldib M,Bini J,Calcagno C,Robson PM,Mani V,Fayad ZA

    更新日期:2014-02-01 00:00:00

  • Ultrasonic echoes registered from erythrocytes.

    abstract::Erythrocytes at various concentrations were examined with a sensitive A-mode ultrasonic scanner; simultaneous measurements were made under light microscopic control. Individual erythrocytes caused weak (about 1 dB) echoes while erythrocyte aggregates (ten to 100 cells) produced stronger echoes (up to 15 dB), grossly p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198508000-00014

    authors: Alanen A,Kormano M

    更新日期:1985-08-01 00:00:00

  • Comparison of left ventricular ejection fraction and regional contractility fraction pre and post coronary angiography.

    abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197603000-00009

    authors: Sos TA,Baltaxe HA

    更新日期:1976-03-01 00:00:00

  • Necrotic areas in VX2 carcinoma of rabbits. Correlation of magnetic resonance imaging and pathologic appearance.

    abstract:RATIONALE AND OBJECTIVES:To assess the potential of magnetic resonance imaging (MRI) for evaluating the evolution of tumor necrosis, the authors evaluated 28 VX2 carcinomas inoculated in the thigh muscles of rabbits. METHODS:MRI of VX2 carcinomas at 2.0 T was done with spin-echo technique 1 week (14 tumors) and 3 week...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199301000-00010

    authors: Choi BI,Lee DH,Han MC

    更新日期:1993-01-01 00:00:00

  • Intrapulmonary 3He gas distribution depending on bolus size and temporal bolus placement.

    abstract:OBJECTIVE:Dynamic ventilation (3)He-MRI is a new method to assess pulmonary gas inflow. As differing airway diameters throughout the ventilatory cycle can influence gas inflow this study intends to investigate the influence of volume and timing of a He gas bolus with respect to the beginning of the tidal volume on insp...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181690111

    authors: Gast KK,Hawig K,Windirsch M,Markstaller K,Schreiber WG,Schmiedeskamp J,Düber C,Kauczor HU,Heussel CP

    更新日期:2008-06-01 00:00:00

  • Role of red blood cell deformation in toxicity of contrast media in cerebral angiography.

    abstract::The authors investigated the effect on the brain of red blood cells that had been modified by contrast media. Rat blood was mixed with an equivolume of contrast media, and up to 200 microL of the mixture was infused to the internal carotid artery of the rat. Evans blue was administered intravenously to assess the inte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198905000-00009

    authors: Miyazawa T,Nakagawa H,Oshino N

    更新日期:1989-05-01 00:00:00

  • Development of a macromolecular dual-modality MR-optical imaging for sentinel lymph node mapping.

    abstract:OBJECTIVE:To evaluate the effectiveness of a dual magnetic resonance-near infrared fluorescence optical imaging agent, poly(l-glutamic acid)-DTPA-Gd-NIR813, for both preoperative and intraoperative visualization and characterization of sentinel lymph nodes (SLN) in mice. MATERIALS AND METHODS:Poly(L-glutamic acid) was...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31804f5a79

    authors: Melancon MP,Wang Y,Wen X,Bankson JA,Stephens LC,Jasser S,Gelovani JG,Myers JN,Li C

    更新日期:2007-08-01 00:00:00

  • Elimination of gadolinium-ethoxybenzyl-DTPA in a rat model of severely impaired liver and kidney excretory function. An experimental study in rats.

    abstract:RATIONALE AND OBJECTIVES:The authors investigated whether gadolinium-ethoxybenzyl-DTPA (Gd-EOB-DTPA) can be eliminated in the absence of the two usual excretory pathways (urinary or biliary) and whether a remaining excretory pathway is able to compensate for impaired liver or kidney function. METHODS:The study was per...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199402000-00017

    authors: Mühler A,Heinzelmann I,Weinmann HJ

    更新日期:1994-02-01 00:00:00

  • Sonography of the kidneys in hemolytic uremic syndrome.

    abstract::The sonographic appearance of kidneys in patients presenting with acute renal failure due to hemolytic-uremic syndrome (HUS) was evaluated and compared with that in an age-matched control series. In nine patients with HUS, the renal cortex was typically hyperechogenic and the renal pyramids appeared sonolucent. The re...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198607000-00006

    authors: Kenney PJ,Brinsko RE,Patel DV,Spitzer RE,Farrar FM

    更新日期:1986-07-01 00:00:00

  • Systolic flow displacement correlates with future ascending aortic growth in patients with bicuspid aortic valves undergoing magnetic resonance surveillance.

    abstract:OBJECTIVES:Altered systolic blood flow in the ascending aorta has been correlated with increased aortic growth in patients with bicuspid aortic valves (BAVs). We used conventional, 2-dimensional (2D) phase contrast magnetic resonance imaging (PC-MRI) to assess the relationship between altered flow and future growth in ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000064

    authors: Burris NS,Sigovan M,Knauer HA,Tseng EE,Saloner D,Hope MD

    更新日期:2014-10-01 00:00:00

  • Detection of low-contrast signals. A comparison of observers with and without radiology training.

    abstract::Sixteen observers averaging 7.4 years experience in interpreting radiology images and 16 observers without radiology training were tested for their ability to detect low-contrast signals in structured noise backgrounds using a digital display system. No significant difference in true positives, false positives, time t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198704000-00006

    authors: Rackow PL,Spitzer VM,Hendee WR

    更新日期:1987-04-01 00:00:00

  • The influence of contrast medium dose on filtration fraction in the rabbit kidney.

    abstract::We have examined the effect of dose on contrast medium-induced reductions in glomerular filtration in anesthetized rabbits. The fraction of renal plasma flow that is filtered, the filtration fraction, was directly measured by the renal arteriovenous difference method using technetium-99m (99mTc) (Sn) DTPA as the trace...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198309000-00007

    authors: Harvey LA,Caldicott WJ

    更新日期:1983-09-01 00:00:00

  • Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility.

    abstract:OBJECTIVES:To test the technique and feasibility of translating tumor suspicious region maps in the prostate, obtained by multimodality, anatomic, and functional 3T magnetic resonance imaging (MRI) data to 32-channel coil, T2-weighted (T2-w), 3T MR images, for directing MR-guided biopsies. Furthermore, to evaluate the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31817d0506

    authors: Hambrock T,Fütterer JJ,Huisman HJ,Hulsbergen-vandeKaa C,van Basten JP,van Oort I,Witjes JA,Barentsz JO

    更新日期:2008-10-01 00:00:00

  • Radioimmunodetection of a transplantable human bladder carcinoma in a nude mouse.

    abstract::The results of an in vitro mixed hemadsorption (MHA) assay predicted the success of in vivo tumor localization using a radioiodinated, monoclonal, IgG1 antibody (A2) with reactivity to the human bladder carcinoma cell line RT4. In vitro, murine monoclonal antibodies A2 and G6, demonstrated reactivity to RT4 with titer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198411000-00011

    authors: Gross MD,Skinner RW,Grossman HB

    更新日期:1984-11-01 00:00:00

  • Breast stereotactic core biopsy washings: abundant cell samples from clinically occult lesions for flow cytometric DNA analysis.

    abstract:RATIONALE AND OBJECTIVES:The object of this study was to determine by flow cytometry the cellular and DNA content of the washings of core biopsy samples and needles obtained during stereotactic core biopsies of clinically occult suspicious lesions. METHODS:Fourteen-gauge core multipass biopsy inner-needle saline washi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199801000-00008

    authors: Stomper PC,Budnick RM,Stewart CC

    更新日期:1998-01-01 00:00:00

  • Sequential change of MR signal intensity of the brain after manganese administration in rabbits. Correlation with manganese concentration and histopathologic findings.

    abstract:RATIONALE AND OBJECTIVES:High signal intensity in the basal ganglia on T1-weighted MR imaging has been reported in chronic manganese (Mn) poisoning. However, the exact meaning of the high signal intensity remains unclear: does it result from Mn itself, secondary pathologic changes of the brain tissue, or both? The goal...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199906000-00001

    authors: Kim SH,Chang KH,Chi JG,Cheong HK,Kim JY,Kim YM,Han MH

    更新日期:1999-06-01 00:00:00

  • Microcomputer-based technique for 3-D reconstruction and volume measurement of computer tomographic images. Part 1: Phantom studies.

    abstract::This paper presents a microcomputer-based technique that accurately quantifies volumes from computed tomographic (CT) scans of irregularly shaped objects as well as displaying 3-D reconstructions. The method uses standard CT film, allowing analysis of previous or outside CT studies. The planimetry method showed less t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198812000-00001

    authors: Albright RE Jr,Fram EK

    更新日期:1988-12-01 00:00:00

  • Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging. Application to unilateral lung transplantation.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of magnetic resonance (MR) to image pulmonary perfusion in healthy controls and to detect pulmonary defects in patients with unilateral lung transplantation, using dynamic images after contrast administration. METHODS:Five patients with right lung transplantation a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199706000-00006

    authors: Berthezène Y,Croisille P,Bertocchi M,Houzard C,Bendib K,Revel D

    更新日期:1997-06-01 00:00:00

  • Comparison of Gd(DTPA-BMA) (Omniscan) versus Gd(HP-DO3A) (ProHance) relative to gadolinium retention in human bone tissue by inductively coupled plasma mass spectroscopy.

    abstract:OBJECTIVE:The objective of this study was to determine the gadolinium (Gd) concentration remaining in human bone tissue after administration of standard clinical doses of 2 Gd-based contrast agents: ProHance and Omniscan. MATERIALS AND METHODS:After administration of 0.1 mmol/kg of Gd chelate to patients undergoing hi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000186569.32408.95

    authors: White GW,Gibby WA,Tweedle MF

    更新日期:2006-03-01 00:00:00

  • Extravascular extravasation of radiographic contrast media. Effects of conventional and low-osmolar agents in the rat thigh.

    abstract::We compared the damage resulting from intradermal injection of four commonly used radiographic contrast media in laboratory rats. Sixty percent meglumine diatrizoate (Reno M 60) and ioxaglate (Hexabrix) produced significantly more ulceration and crusting on gross inspection and more necrosis, edema, and hemorrhage on ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199005000-00006

    authors: Cohan RH,Leder RA,Bolick D,Herzberg AJ,Hedlund LW,Wheeler CT,Helms MJ,Dunnick NR

    更新日期:1990-05-01 00:00:00