Abstract:
RATIONALE AND OBJECTIVES:The authors studied the effect of contrast dose, use of magnetization transfer (MT), and temporal delay on the visualization of contrast enhancement with gadoteridol (Gd HP-DO3A) in a canine brain abscess model. METHODS:Alpha streptococcus brain abscesses were studied in five dogs at 1.5 tesla (T) 1 and 5 days after implantation. Scans were performed 1, 11, and 21 minutes after contrast was administered, using an initial dose of 0.1 mmol/kg. A supplemental contrast injection of 0.2 mmol/kg was given (for a cumulative dose of 0.3 mmol/kg), with scans repeated at 31, 41, and 51 minutes. RESULTS:Lesion conspicuity on day 1 was greater at high-contrast doses (0.3 mmol/kg) compared with standard doses (0.1 mmol/kg), regardless of whether imaging was performed without (0.89 +/- 0.02 compared with 0.26 +/- 0.08) or with (0.97 +/- 0.04 compared with 0.28 +/- 0.06) MT. High-dose, MT, and a delay after contrast was injected all produced a statistically significant improvement. On blinded review of films obtained 11 and 14 minutes after injection, enhancement of the lesion could not be identified with certainty in two of five dogs at a dose of 0.1 mmol/kg, regardless of whether MT was used. Enhancement was seen consistently in all lesions at 0.3 mmol/kg. On day 5, results were comparable, with greater absolute enhancement. CONCLUSIONS:In early brain infection, high-contrast doses (0.3 mmol/kg), MT, and a moderate delay after injection all improve visualization of lesion enhancement.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Runge VM,Wells JW,Kirsch JEdoi
10.1097/00004424-199503000-00001subject
Has Abstractpub_date
1995-03-01 00:00:00pages
135-43issue
3eissn
0020-9996issn
1536-0210journal_volume
30pub_type
杂志文章abstract:RATIONALE AND OBJECTIVES:Hepatocellular carcinomas (HCCs) usually consist of components of different histologic grade. Using surgically resected specimens, the authors obtained high-resolution magnetic resonance (MR) images and studied the relationship between histologic grade of HCCs and MR signal intensity. METHOD:I...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199308000-00007
更新日期:1993-08-01 00:00:00
abstract::The magnitude and timing of the effects of postural change on pulmonary blood flow distribution were studied in dogs by means of computed tomography (CT) and radioactive microspheres. A change in the mean attenuation values was demonstrated by CT in the anterior and posterior lung zones after change from the supine to...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198211000-00007
更新日期:1982-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Very small dextran-coated magnetite particles were developed. These particles can be used either as immunospecific contrast agents for MRI by coupling to antibodies or as an interstitial contrast agent. METHODS:The particles were synthesized from iron chloride/dextran solutions. Size was evalu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200009000-00006
更新日期:2000-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Low-field magnetic resonance imaging (MRI) evaluation of breast implants is described, with emphasis on the capabilities provided by different imaging sequences. METHODS:Open architecture MR images using a .064-T permanent magnet and three-dimensional Fourier transform and inversion recovery s...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199408000-00009
更新日期:1994-08-01 00:00:00
abstract::A feasibility study is described to provide quantitative texture measures to distinguish between normal lung, alveolar infiltrates and interstitial infiltrates. Advanced computer imaging technology and decision making processes were applied to distinguish between these textural patterns. The results, based on computer...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197807000-00005
更新日期:1978-07-01 00:00:00
abstract::The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed imme...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1985-09-01 00:00:00
abstract::In order to measure the accuracy of a diagnostic imaging technique, the correctness of each observer decision must be determined. This is often difficult in clinical cases, and various strategies are frequently used to approximate the truth. Experiments using chest radiographs as an example are reported to show the pi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198303000-00018
更新日期:1983-03-01 00:00:00
abstract:BACKGROUND:Nephrogenic systemic fibrosis (NSF) has been related to the use of gadolinium-based contrast agents (GBCAs) in patients undergoing dialysis. The Prospective Fibrose Nephrogénique Systémique study, a French prospective study supported by the French drug regulatory agency (Agence Nationale de Sécurité du Médic...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/RLI.0000000000000000
更新日期:2014-02-01 00:00:00
abstract::We compared the damage resulting from intradermal injection of four commonly used radiographic contrast media in laboratory rats. Sixty percent meglumine diatrizoate (Reno M 60) and ioxaglate (Hexabrix) produced significantly more ulceration and crusting on gross inspection and more necrosis, edema, and hemorrhage on ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199005000-00006
更新日期:1990-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To improve the accuracy of magnetic resonance imaging (MRI) in evaluating the response of osteosarcomas to preoperative chemotherapy, the authors developed a technique of mapping tumor necrosis and viability by quantitating slope values of gadolinium-DTPA (Gd-DTPA) uptake on dynamic fast low-an...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199205000-00010
更新日期:1992-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To develop a computer-assisted analysis of complex joint motion based on standard fluoroscopic sequences. MATERIALS AND METHODS:Fluoroscopic sequences of 10 normal shoulders and 20 patients after total shoulder arthroplasty were recorded during abduction and adduction. The analysis of the shou...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200202000-00004
更新日期:2002-02-01 00:00:00
abstract:OBJECTIVES:The safety of nonionic contrast agents with that of ionic iodinated contrast agents in children is compared. METHODS:A comprehensive literature search was conducted to identify all publications on the safety profile of nonionic contrast agents administered intravenously to children. This information was com...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199311001-00027
更新日期:1993-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors developed a two-dimensional breathhold magnetic resonance (MR) technique for the direct imaging of pulmonary emboli. METHODS:In vitro MR imaging was performed to demonstrate the potential generation of clot-blood contrast by in vivo pulmonary embolism (PE). A two-dimensional magnet...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199708000-00001
更新日期:1997-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVE:The authors performed a retrospective study in ultrasound to investigate new aspects in the sonomorphology of lymph node metastases of the neck. In this study, it could be demonstrated the first time that the histologic characteristics of the metastases determine the sonographic appearance. In a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199609000-00001
更新日期:1996-09-01 00:00:00
abstract::Breast calcification diagnosis was studied by using clinical findings and computerized image processing of a mammogram in a network of trained expert learning systems (Outcome Advisor [OA]). The system was tested with records not used for training and performance was compared with radiologist. The network was 72% accu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199106000-00004
更新日期:1991-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors differentiate breast lesions on sonography by measurements in two compression states that are perpendicular to each other. METHODS:Diameters of 100 breast lesions were measured preoperatively under lateromedial and craniocaudal compression with a new sonographic method. This method...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199607000-00003
更新日期:1996-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199303000-00010
更新日期:1993-03-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to evaluate the effect of structured reports (SRs) in comparison to nonstructured, free-text (FT) rectal magnetic resonance imaging (MRI) reports in patients with histologically proven rectal cancer and potential effects of both types of reporting on referring surgeons' satisfaction...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000336
更新日期:2017-04-01 00:00:00
abstract:OBJECTIVE:To investigate the effect of saline chase injected at 2 different rates on computed tomography (CT) angiography. MATERIALS AND METHODS:This study was approved by our institutional animal study committee. Three injection protocols were used; contrast injection (24 mL, 0.8 mL/s) without saline chase (protocol ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318032a9fe
更新日期:2007-07-01 00:00:00
abstract:RATIONAL AND OBJECTIVES:The feasibility of tubal occlusion by selective salpingography was tested in an animal model; three novel occluding materials also were tested for this application. METHODS:Unilateral selective salpingography was performed in three groups of six rabbits; fallopian tubes were embolized with etha...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199402000-00007
更新日期:1994-02-01 00:00:00
abstract::Due to the nature of three-dimensional Fourier transform (3-DFT) data acquisition in magnetic resonance imaging (MRI), the spatial relation between a resolved volume element (a voxel) and the object can be manipulated easily. Those manipulations have practical consequences in terms of registering slice positions with ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199012000-00006
更新日期:1990-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The basic characteristics of BR1, a novel echo contrast agent based on stabilized sulfur hexafluoride (SF6) microbubbles have been evaluated. METHODS:The authors determined the physicochemical properties (bubble concentration, bubble size distribution, resistance to pressure, and stability) an...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199508000-00001
更新日期:1995-08-01 00:00:00
abstract:OBJECTIVES:Thermal dose in tumor tissue is a key factor for regional hyperthermia (HT) combined with chemotherapy and for drug delivery using thermosensitive liposomes (TSL). It influences therapy outcome, affects the accumulation of liposomes, and triggers the content release from TSL in the target tissue. For the dev...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31818768cd
更新日期:2008-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199312000-00001
更新日期:1993-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Magnetic resonance microscopy (MRM) has evolved from a technical curiosity to a tool with which researchers can study important disease models. But MRM is not simply an extension of clinical magnetic resonance imaging. In this article, the unique adaptations of MRM required in the study of caro...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199409000-00004
更新日期:1994-09-01 00:00:00
abstract::Multiple intravenous injections of contrast media are used in radiology, but information regarding corresponding changes in the serum iodine concentrations and osmolality is lacking. We measured the changes in serum iodine concentration and serum osmolality in rabbits after a series of intravenous injections of contra...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198703000-00007
更新日期:1987-03-01 00:00:00
abstract:RATIONAL AND OBJECTIVES:The purpose of this study was to evaluate the effects of variation in design parameters on the resultant radial force. We evaluated the influence of wire gauge, leg length, and number of bends on the radial force produced by z stents and compared these with radial forces produced by commercial s...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200109000-00004
更新日期:2001-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The efficacy of gadoteridol for contrast enhancement of central nervous system pathology was assessed in a multicenter clinical trial involving 411 patients suspected of having intracranial or spinal pathology. METHODS:Magnetic resonance imaging was performed before and after intravenous admin...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:
更新日期:1992-08-01 00:00:00
abstract::Flow measurements can be made with computed tomography (CT) scanners using iodinated, nonionic contrast media as a first-pass indicator. Ultrafast CT (UFCT) is an ideal machine to make these measurements because of its short scan time (50 mseconds) and interscan delay (< or = 0.6 seconds). Additionally, UFCT can acqui...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199212002-00004
更新日期:1992-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200207000-00005
更新日期:2002-07-01 00:00:00