Abstract:
RATIONAL AND OBJECTIVES:The feasibility of tubal occlusion by selective salpingography was tested in an animal model; three novel occluding materials also were tested for this application. METHODS:Unilateral selective salpingography was performed in three groups of six rabbits; fallopian tubes were embolized with ethanol (group 1), a hydrogel (group 2), or an occluding emulsion (Ethibloc, Laboratoire Princeps, Neuilly sur Seine, France) (group 3). Animals were killed 2 days or 30 days after the procedure, according to randomization; tubal patency and histologic modifications were evaluated. RESULTS:Selective tubal catheterization was obtained in 100% of the cases. In group 1, no satisfactory occlusion was obtained; in group 2, 65% of the tubes were occluded with little histologic damage; in group 3, 80% of the tubes were occluded, but significant inflammation and tissue necrosis were noted. CONCLUSION:Selective salpingography proved a suitable method for gaining access to the fallopian tube and allowed selective injection of occluding materials. More research is needed to determine a suitable occluding material, focusing on biocompatibility and on long-term efficacy. :Unilateral selective salpingography was performed in 3 groups of 6 rabbits. 4-6 month old, virgin New Zealand White female rabbits were used with a mean weight of 4.4 kg. The fallopian tubes were embolized with ethanol (group 1); a viscous radiopaque solution which solidifies rapidly after injection to produce a biocompatible and inert hydrogel (group 2); or an occluding emulsion (a radiopaque heterogeneous alcoholic solution of zein, poppy seed oil, propylene glycol, and sodium amidotrizoate from Ethibloc, Laboratoire Princeps, Neuilly sur Seine, France) (group 3). Animals were killed 2 days or 30 days after the procedure, according to randomization; and tubal patency and histologic modifications were evaluated. Selective tubal catheterization was possible in all 18 cases, in 12 cases on the right side (66%), in 6 cases on the left side (33%); in 11 cases with a 5F catheter (61%), in 7 cases with a 2.5F catheter (39%). In group 1, no satisfactory occlusion was obtained; in group 2, 65% of the tubes were occluded with little histologic damage; and in group 3, 80% of the tubes were occluded, but significant inflammation and tissue necrosis were noted. The fallopian tubes were selectively catheterized over variable lengths: over 10 mm in 5 rabbits (28%), between 5 and 10 mm in 4 rabbits (22%), and between 1 and 5 mm in 9 rabbits (50%). Before injection of the occluding materials, all the catheterized tubes were patent. Mean volume of occluding material injected was 0.36 mL in group 1, 0.30 mL in group 2, and 0.83 mL in group 3. The ethanol injected reached the peritoneum in all 6 rabbits. The gel was injected an average length of 11 mm in the tube, while the emulsion opacified all the volume of the tubes with a peritoneal spill of emulsion in 3 of 6 cases. Reflux of occluding material into the uterus was noted in 1 of 6 rabbits in group 1, in 4 of 6 rabbits in group 2, in 3 of 6 rabbits in group 3. Selective salpingography proved a suitable method and allowed selective injection of occluding materials.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Maubon A,Rouanet JP,Laurent A,Joujoux JM,Cover S,Courtieu C,Wassef M,Godlewski G,Honiger J,Lopez FMdoi
10.1097/00004424-199402000-00007keywords:
["Animals, Laboratory","Clinical Research","Family Planning","Female Sterilization","Research Report","Sterilization, Sexual","Tubal Occlusion"]subject
Has Abstract,Author List Incompletepub_date
1994-02-01 00:00:00pages
156-61issue
2eissn
0020-9996issn
1536-0210journal_volume
29pub_type
杂志文章abstract::Using simple surgical techniques, experimental carotid aneurysms are created which simulate some types of human berry aneurysms, both in hemodynamic and radiographic behavior. End to side anastomoses of an external jugular vein graft to the common carotid artery can be carried out by radiologic personnel with no forma...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197703000-00009
更新日期:1977-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Ureteric jet index (UJI), a newly developed technique derived from color Doppler ultrasonography, may hold promise in evaluating renal function because of its ability to evaluate individual renal function and the use of nonionizing radiation. To assess the usefulness of UJI, the authors in this...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199908000-00001
更新日期:1999-08-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of kidney stone composition analysis using spectral detector computed tomography scanner (SDCT) with normal- and low-dose imaging protocols. METHODS:A total of 154 stones harvested from nephrolithotripsy or nephrolithotomy with a known monocrystalline...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000468
更新日期:2018-08-01 00:00:00
abstract:OBJECTIVE:To determine the prevalence of nephrogenic systemic fibrosis (NSF) in patients with chronic kidney disease (CKD) who have received gadopentetate dimeglumine. MATERIALS AND METHODS:We retrospectively studied all patients who underwent contrast-enhanced magnetic resonance imagings (CE-MRIs) between January 1, ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31819343ba
更新日期:2009-03-01 00:00:00
abstract:OBJECTIVE:To investigate the feasibility of an 80-kVp protocol using a moderate concentration contrast material (MC-CM) for cerebral computed tomography angiography by comparison with a conventional 120-kVp protocol using a high concentration contrast material (HC-CM). MATERIALS AND METHODS:Attenuation values and sign...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31823076a4
更新日期:2012-02-01 00:00:00
abstract::The results of an in vitro mixed hemadsorption (MHA) assay predicted the success of in vivo tumor localization using a radioiodinated, monoclonal, IgG1 antibody (A2) with reactivity to the human bladder carcinoma cell line RT4. In vitro, murine monoclonal antibodies A2 and G6, demonstrated reactivity to RT4 with titer...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198411000-00011
更新日期:1984-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199704000-00008
更新日期:1997-04-01 00:00:00
abstract::There are a number of sonographic findings seen in fibroadenoma of the breast. In a retrospective study, we examined the biopsy results of 59 masses given the sonographic diagnosis of fibroadenoma. We also reviewed the sonograms of an additional 26 biopsy-proven fibroadenomas that were not diagnosed as such with ultra...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198601000-00006
更新日期:1986-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Air microemboli may damage the cerebral microvasculature. The aim of this study was to evaluate the safety of ultrasound contrast agents composed of air microspheres with regard to cerebral damage when administered into the arterial system (ie, when not filtered by the capillary system of the l...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199803000-00001
更新日期:1998-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Measurements of segmental contraction of the left ventricle by standard magnetic resonance imaging (MRI) and two-dimensional echocardiography involve the comparison of diastolic and systolic time frames acquired from the same imaging plane in space. As the cone-shaped left ventricle shortens al...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199209000-00004
更新日期:1992-09-01 00:00:00
abstract:OBJECTIVES:To test the technique and feasibility of translating tumor suspicious region maps in the prostate, obtained by multimodality, anatomic, and functional 3T magnetic resonance imaging (MRI) data to 32-channel coil, T2-weighted (T2-w), 3T MR images, for directing MR-guided biopsies. Furthermore, to evaluate the ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31817d0506
更新日期:2008-10-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a convention...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000459
更新日期:2018-10-01 00:00:00
abstract:BACKGROUND:Gadolinium leakage in ocular structures (GLOS) was recently observed in fluid-attenuated inversion recovery (FLAIR) images obtained the day after an initial gadolinium injection in stroke patients. The specificity of GLOS to stroke and its mechanisms remain unclear. OBJECTIVE:We investigated the factors ass...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000757
更新日期:2021-01-19 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors differentiate breast lesions on sonography by measurements in two compression states that are perpendicular to each other. METHODS:Diameters of 100 breast lesions were measured preoperatively under lateromedial and craniocaudal compression with a new sonographic method. This method...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199607000-00003
更新日期:1996-07-01 00:00:00
abstract::Multiple intravenous injections of contrast media are used in radiology, but information regarding corresponding changes in the serum iodine concentrations and osmolality is lacking. We measured the changes in serum iodine concentration and serum osmolality in rabbits after a series of intravenous injections of contra...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198703000-00007
更新日期:1987-03-01 00:00:00
abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198011001-00053
更新日期:1980-11-01 00:00:00
abstract:OBJECTIVES:We sought to assess large bowel motility, induced by 2 prokinetic agents, senna tea and erythromycin, using functional cine magnetic resonance imaging (MRI). MATERIALS AND METHODS:Twelve volunteers underwent functional cine MRI before and after the administration of senna tea or erythromycin. The protocol c...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000183054.43131.a8
更新日期:2005-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate different vein graft-coated stent systems in the endovascular treatment of experimental arteriovenous fistulae (AVF) in a canine model. METHODS:Bilateral carotid-to-external jugular vein AVF were created. Two balloon-expandable tantalum stents (Strecker stent), two self-expanding n...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199901000-00004
更新日期:1999-01-01 00:00:00
abstract::Experimental pulmonary arteritis was produced in rabbits by intravenous injection of alveolar macrophages from donor rabbits. These animals, along with matched controls, were studied with pulmonary angiography to test the hypothesis that angiography could detect the vasculitic process in life. The animals were then sa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198007000-00005
更新日期:1980-07-01 00:00:00
abstract:OBJECTIVES:The safety of nonionic contrast agents with that of ionic iodinated contrast agents in children is compared. METHODS:A comprehensive literature search was conducted to identify all publications on the safety profile of nonionic contrast agents administered intravenously to children. This information was com...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199311001-00027
更新日期:1993-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The vascular opacification characteristics of a new nonionic, dimeric contrast agent, iodixanol, have been compared with a nonionic, monomeric agent, iohexol, using ultrafast computed tomography (UFCT). METHODS:In 10 experiments with mongrel dogs, the contrast agents were alternately injected ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199212000-00011
更新日期:1992-12-01 00:00:00
abstract::In this article, we propose a semiautomatic method for time-continuous contour detection in all phases of the cardiac cycle in magnetic resonance sequences. The method is based on multidimensional dynamic programming. After shape parameterization, cost hypercubes are filled with image-feature derived cost function val...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000194070.88432.24
更新日期:2006-01-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to present a deep learning approach for the automated classification of multiple sclerosis and its mimics and compare model performance with that of 2 expert neuroradiologists. MATERIALS AND METHODS:A total of 268 T2-weighted and T1-weighted brain magnetic resonance imagin scans ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000735
更新日期:2020-10-26 00:00:00
abstract::The extent to which various concentrations of the paramagnetic metal ions [gadolinium (III), manganese (II), chromium (III), iron (III), nickel (II), copper (II), and cobalt (II)] affect proton magnetic relaxation times of distilled water, 4% human serum albumin (HSA), and dog plasma was studied in vitro. The pH of wa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198602000-00009
更新日期:1986-02-01 00:00:00
abstract:OBJECTIVES:To prospectively evaluate the image quality and diagnostic accuracy of magnetic resonance cholangiopancreatography (MRCP) at 3.0 T compared with that at 1.5 T used for patients. MATERIALS AND METHODS:This study was approved by our institutional review board, and informed consent was obtained from all patien...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181b4c0ae
更新日期:2009-09-01 00:00:00
abstract:MATERIALS AND METHODS:Stenotic kidney (STK) and contralateral kidney magnetization transfer ratios (MTRs; Mt/M0) were measured at 3.0-T magnetic resonance imaging, at offset frequencies of 600 and 1000 Hz, before and 1 month post-PTRA in 7 RVD pigs. Stenotic kidney MTR was correlated to renal perfusion, renal blood flo...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000711
更新日期:2021-02-01 00:00:00
abstract:OBJECTIVES:To evaluate the performance of black-blood diffusion-weighted (DW)-EPI sequences with parallel imaging for the detection of focal liver lesions in comparison with a standard T2-weighted (T2-w) sequence. MATERIALS AND METHODS:Twenty patients with known or suspected focal liver lesions underwent liver MRI usi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31816200b5
更新日期:2008-04-01 00:00:00
abstract::A high-speed computed tomography (CT) scanner was used for measuring flow in a phantom and in the common carotid arteries of six dogs. The general ability of the scanner to assess flow using contrast media boluses was tested with the phantom. The validated simple concept was then used in the animals. The carotid blood...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198712000-00008
更新日期:1987-12-01 00:00:00
abstract:PURPOSE:We sought to prospectively evaluate the image quality and visualization of the intracranial arteries using high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) at 3 T and to perform intraindividual comparison with time-of-flight (TOF) MRA and multislice CT angiography (CTA). MATERI...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/01.rli.0000242835.00032.f5
更新日期:2006-11-01 00:00:00
abstract:OBJECTIVES:Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a method to heat lesions noninvasively to a stable, elevated temperature and a well-suited method to induce local hyperthermia (41°C-43°C) in deep-seated tissues. Magnetic Resonance (MR) imaging provides therapy planning on anatomical i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000392
更新日期:2017-10-01 00:00:00