Continuous Hepatic Arterial Multiphase Magnetic Resonance Imaging During Free-Breathing.

Abstract:

PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a conventional breath-hold approach (VIBESTD). MATERIAL AND METHODS:A total of 40 patients with liver malignancies were prospectively included in this study and underwent contrast-enhanced liver MRI at 1.5 T to evaluate the performance of VIBECS for rapid arterial multiphase imaging. An additional 40 patients examined with a VIBESTD were included serving as standard of reference. The VIBECS study cohort was subdivided into 2 groups (each n = 20). In both groups, VIBECS was continuously acquired for 60 seconds starting with the contrast agent administration (group A, temporal resolution 4 seconds; group B, temporal resolution 8 seconds). Subsequently, the time point with the subjectively best image quality was selected and defined as hepatic arterial dominant (HAD) phase. Overall image quality, lesion conspicuity, vessel contrast, and artifacts of HAD phase were assessed by 2 radiologists independently on a 5-point Likert scale (5 = excellent) and compared with arterial phase images of VIBESTD. In addition, signal attenuation/time curves of VIBECS were plotted for each patient to quantify the hepatic arterial enhancement. RESULTS:No patients were excluded and all HAD phases were reliably recorded in the investigated VIBECS cohort. Most commonly, HAD was observed at the ninth time point (36 seconds after intravenous contrast injection) in group A and at the fifth time point (40 seconds after intravenous contrast injection) in group B. Timing with VIBESTD was only adequate in 65% (26/40). Image quality, lesion conspicuity, and vessel contrast were good to excellent without significant differences between both VIBECS groups (P ≥ 0.2) and with significantly higher reading scores as compared with VIBESTD with respect to lesion conspicuity (P ≤ 0.006) and image quality (group B; P < 0.001). VIBECS showed reconstruction artifacts, which were significantly higher in group A (P = 0.001). Mean peak arterial enhancement was observed at the ninth time point (36 seconds) in group A and at the sixth (48 seconds) in group B. CONCLUSION:VIBECS allows for robust multiphase arterial imaging during free-breathing at high spatial and temporal resolution (preferably 8 seconds) with improved image quality and lesion conspicuity as compared with VIBESTD.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Weiss J,Notohamiprodjo M,Taron J,Martirosian P,Nickel D,Bamberg F,Nikolaou K,Othman AE

doi

10.1097/RLI.0000000000000459

subject

Has Abstract

pub_date

2018-10-01 00:00:00

pages

596-601

issue

10

eissn

0020-9996

issn

1536-0210

journal_volume

53

pub_type

杂志文章
  • Thoracic metastases from cervical carcinoma: current status.

    abstract::Thoracic metastases from squamous carcinoma and adenocarcinoma of the cervix were studied by reviewing 245 consecutive cases to describe comparative incidence, natural history, and radiographic patterns. The incidence of chest metastases was higher for adenocarcinoma (20%) than for squamous carcinoma (4%). Few patient...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198003000-00004

    authors: Sostman HD,Matthay RA

    更新日期:1980-03-01 00:00:00

  • Contrast media-induced renal tubular vacuolization. A light and electron microscopic study on rat kidneys.

    abstract::The morphologic changes in healthy rat kidneys (n = 102) were studied 2 or 48 hours after intravenous injection of 1 or 3 g iodine (I)/kg of high-osmolality diatrizoate, low-osmolality iopromide and iohexol, or iso-osmolality iotrolan, as well as after 0.2 or 0.6 g/kg of the high-osmolality magnetic resonance contrast...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199110000-00009

    authors: Tervahartiala P,Kivisaari L,Kivisaari R,Virtanen I,Standertskjöld-Nordenstam CG

    更新日期:1991-10-01 00:00:00

  • Magnetization transfer and high-dose contrast in early brain infection on magnetic resonance.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the effect of contrast dose, use of magnetization transfer (MT), and temporal delay on the visualization of contrast enhancement with gadoteridol (Gd HP-DO3A) in a canine brain abscess model. METHODS:Alpha streptococcus brain abscesses were studied in five dogs at 1.5 tesla...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199503000-00001

    authors: Runge VM,Wells JW,Kirsch JE

    更新日期:1995-03-01 00:00:00

  • Acute systemic and renal hemodynamic effects of meglumine/sodium diatrizoate 76% and iopamidol in euvolemic and dehydrated dogs.

    abstract::We examined the acute systemic and renal hemodynamic effects of intravenous meglumine/sodium diatrizoate-76% and iopamidol in euvolemic and dehydrated dogs. The physiologic responses were compared with acute changes in the level of an endogenous heparin-like material (EHM). One of eight dehydrated dogs receiving diatr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198610000-00005

    authors: Katzberg RW,Morris TW,Lasser EC,DiMarco PL,Merguerian PA,Ventura JA,Pabico RC,McKenna BA

    更新日期:1986-10-01 00:00:00

  • Characteristics of magnetic resonance sequences used for imaging silicone gel, saline, and gel-saline implants at low field strengths.

    abstract:RATIONALE AND OBJECTIVES:Low-field magnetic resonance imaging (MRI) evaluation of breast implants is described, with emphasis on the capabilities provided by different imaging sequences. METHODS:Open architecture MR images using a .064-T permanent magnet and three-dimensional Fourier transform and inversion recovery s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199408000-00009

    authors: Frankel S,Occhipinti K,Kaufman L,Kramer D,Carlson J,Mineyev M,Friedenthal R

    更新日期:1994-08-01 00:00:00

  • The retropsoas recess. Demonstration using computed tomography.

    abstract::The retropsoas recess, a previously undescribed normal anatomic variant, is reported. In most individuals, the space posterior to the belly of the psoas muscle contains fat within the posterior pararenal space. However, a retrospective review of 250 consecutive CT examinations of the abdomen revealed 11 cases (4.4%) i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198707000-00004

    authors: Kelly RB,Mahoney PD,Frick MP

    更新日期:1987-07-01 00:00:00

  • Magnetic resonance imaging of pulmonary ventilation. Initial experiences with a gadolinium-DTPA-based aerosol.

    abstract:RATIONALE AND OBJECTIVES:The authors investigate whether a modified gadolinium (Gd)-DTPA formulation can be aerosolized and used as a contrast agent for magnetic resonance (MR) ventilation imaging of the lungs. METHODS:Gadolinium-DTPA (gadopentetate dimeglumine, Schering AG, Berlin, Germany, 100 mmol Gd/L) was modifie...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199712000-00010

    authors: Misselwitz B,Mühler A,Heinzelmann I,Böck JC,Weinmann HJ

    更新日期:1997-12-01 00:00:00

  • Magnetic resonance evaluation of regional left ventricular function. Effect of through-plane motion.

    abstract:RATIONALE AND OBJECTIVES:Measurements of segmental contraction of the left ventricle by standard magnetic resonance imaging (MRI) and two-dimensional echocardiography involve the comparison of diastolic and systolic time frames acquired from the same imaging plane in space. As the cone-shaped left ventricle shortens al...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199209000-00004

    authors: Pattynama PM,Doornbos J,Hermans J,van der Wall EE,de Roos A

    更新日期:1992-09-01 00:00:00

  • Reproducibility, accuracy, and predictors of accuracy for the detection of coronary atherosclerotic plaque composition by computed tomography: an ex vivo comparison to intravascular ultrasound.

    abstract:PURPOSE:To determine the reproducibility, accuracy, and predictors of accuracy of computed tomography (CT) angiography to detect and characterize coronary atherosclerotic plaque as compared with intravascular ultrasound. METHODS:Ten ex vivo human coronary arteries were imaged in a moving phantom by dual-source CT (col...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e0a541

    authors: van der Giessen AG,Toepker MH,Donelly PM,Bamberg F,Schlett CL,Raffle C,Irlbeck T,Lee H,van Walsum T,Maurovich-Horvat P,Gijsen FJ,Wentzel JJ,Hoffmann U

    更新日期:2010-11-01 00:00:00

  • Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility.

    abstract:OBJECTIVES:To test the technique and feasibility of translating tumor suspicious region maps in the prostate, obtained by multimodality, anatomic, and functional 3T magnetic resonance imaging (MRI) data to 32-channel coil, T2-weighted (T2-w), 3T MR images, for directing MR-guided biopsies. Furthermore, to evaluate the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31817d0506

    authors: Hambrock T,Fütterer JJ,Huisman HJ,Hulsbergen-vandeKaa C,van Basten JP,van Oort I,Witjes JA,Barentsz JO

    更新日期:2008-10-01 00:00:00

  • Pharmacologic treatment of intimal hyperplasia after metallic stent placement in the peripheral arteries. An experimental study.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the efficacy of oral administration of cilostazol, an antithrombotic agent, for the prevention of thrombotic occlusion and intimal hyperplasia after stenting. METHODS:Single-bodied Z-stents were placed in the iliac arteries of 23 dogs. Before stenting, an embolizing coil was introd...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199509000-00004

    authors: Kubota Y,Kichikawa K,Uchida H,Maeda M,Nishimine K,Makutani S,Sakaguchi S,Yoshioka T,Ohishi H,Kimura Y

    更新日期:1995-09-01 00:00:00

  • Changes in complement and coagulation factors in a patient suffering a severe anaphylactoid reaction to injected contrast material: some considerations of pathogenesis.

    abstract::A patient, suffering a severe anaphylactoid reaction to contrast material injected for an intravenous pyelogram, developed a consumption coagulopathy and evidence of complement activation. Precontrast complement values suggested that the patient had been processing complement via the classical pathway, perhaps as a co...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00004

    authors: Lasser EC,Lang JH,Lyon SG,Hamblin AE

    更新日期:1980-11-01 00:00:00

  • The effect of radiographic contrast media on leukocyte motility.

    abstract:RATIONALE AND OBJECTIVES:Studies describing the effects of radiographic contrast media (RCM) in leukocyte chemotaxis have been contradictory. No studies have been performed after in-vivo exposure. The authors assess the effect of RCM on leukocytes following in-vivo exposure. METHODS:Seventeen patients were studied aft...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199401000-00012

    authors: Roobottom CA,Farrow R,Wells IP,Hurlock-Fimls N

    更新日期:1994-01-01 00:00:00

  • Renal effects of bicarbonate versus saline infusion for iso- and lowosmolar contrast media in rats.

    abstract:OBJECTIVE:Hydration is widely accepted as an effective measure to prevent contrast media (CM)-induced acute kidney injury (AKI). Whether bicarbonate (NaHCO₃) infusion has a greater effect than saline is disputed. Effective prevention of CM-induced AKI by NaHCO₃ has been found by several clinical trials. However, others...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31822311a9

    authors: Ladwig M,Flemming B,Seeliger E,Sargsyan L,Persson PB

    更新日期:2011-11-01 00:00:00

  • Application of a Novel Iterative Denoising and Image Enhancement Technique in T1-Weighted Precontrast and Postcontrast Gradient Echo Imaging of the Abdomen: Improvement of Image Quality and Diagnostic Confidence.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact of a novel iterative denoising and image enhancement technique in T1-weighted precontrast and postcontrast volume-interpolated breath-hold examination (VIBE) of the abdomen on image quality, noise levels, and diagnostic confidence without change of acquisit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000746

    authors: Gassenmaier S,Afat S,Nickel D,Kannengiesser S,Herrmann J,Hoffmann R,Othman AE

    更新日期:2020-11-18 00:00:00

  • Whole-body diffusion-weighted imaging with apparent diffusion coefficient mapping for treatment response assessment in patients with diffuse large B-cell lymphoma: pilot study.

    abstract:OBJECTIVES:The aim of this pilot study was to assess post-treatment apparent diffusion coefficient (ADC) changes of diffuse large B-cell lymphoma lesions on respiratory-gated whole-body diffusion-weighted imaging (DWI), with integrated (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182087b03

    authors: Lin C,Itti E,Luciani A,Zegai B,Lin SJ,Kuhnowski F,Pigneur F,Gaillard I,Paone G,Meignan M,Haioun C,Rahmouni A

    更新日期:2011-05-01 00:00:00

  • Observer variation in detecting the radiologic features associated with bronchiolitis.

    abstract::Chest radiographs are commonly obtained to assess children for bronchiolitis, both to corroborate the diagnosis and to exclude other diagnostic possibilities. Their utility in this setting has not previously been examined. Using a blinded, randomized study design, we examined the interobserver and intraobserver variat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199102000-00004

    authors: Coblentz CL,Babcook CJ,Alton D,Riley BJ,Norman G

    更新日期:1991-02-01 00:00:00

  • Pulmonary microangiography. A comparison of in vitro versus in vivo perfusion techniques in dogs.

    abstract::Because of a need to correlate pulmonary microvascular changes with physiologic data during lung injury, in vitro and in vivo pulmonary capillary microangiography was performed on normal dogs and those subjected to oleic acid injury and glass bead microembolization. During these studies, no significant differences wer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Clark RL,Friedman M,Kwock L,Zaremba J

    更新日期:1983-01-01 00:00:00

  • Effect of Age on High T1 Signal Intensity of the Dentate Nucleus and Globus Pallidus in a Large Population Exposed to Gadodiamide.

    abstract:OBJECTIVE:The purpose of this study was to assess the effect of age and number of previous injections of gadodiamide on the signal intensity of unenhanced T1-weighted (T1w) images of the dentate nucleus and globus pallidus in a large population. MATERIALS AND METHODS:A large, single-center retrospective population sur...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000431

    authors: Quattrocchi CC,Errante Y,Mallio CA,Marinelli L,LoVullo G,Giannotti G,Della Sala SW,van der Molen AJ,Beomonte Zobel B

    更新日期:2018-04-01 00:00:00

  • Incompatibility of water-soluble contrast media and intravascular pharmacologic agents. An in vitro study.

    abstract::In vitro incompatibilities between nine water-soluble contrast media and 21 intravascular pharmacologic agents were investigated using naked-eye observation and a centrifuge. Most of the previously reported incompatibilities were verified, and a few new incompatibilities were discovered: phentolamine mesylate with dia...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199201000-00008

    authors: Kim SH,Lee HK,Han MC

    更新日期:1992-01-01 00:00:00

  • Identifying tumor vascular permeability heterogeneity with magnetic resonance imaging contrast agents.

    abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200204000-00003

    authors: Aref M,Brechbiel M,Wiener EC

    更新日期:2002-04-01 00:00:00

  • Noninvasive inductive stent heating: alternative approach to prevent instent restenosis?

    abstract:RATIONALE AND OBJECTIVES:To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. METHODS:Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000117881.42422.72

    authors: Floren MG,Günther RW,Schmitz-Rode T

    更新日期:2004-05-01 00:00:00

  • 18F-Fluorodeoxyglucose Positron Emission Tomography/Magnetic Resonance in Lymphoma: Comparison With 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography and With the Addition of Magnetic Resonance Diffusion-Weighted Imaging.

    abstract:OBJECTIVES:The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lym...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000218

    authors: Giraudo C,Raderer M,Karanikas G,Weber M,Kiesewetter B,Dolak W,Simonitsch-Klupp I,Mayerhoefer ME

    更新日期:2016-03-01 00:00:00

  • Binary nature and radiographic identifiability of craniosynostosis.

    abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199410000-00005

    authors: Pilgram TK,Vannier MW,Marsh JL,Kraemer BB,Rayne SC,Gado MH,Moran CJ,McAlister WH,Shackelford GD,Hardesty RA

    更新日期:1994-10-01 00:00:00

  • Clinical and High-Resolution CT Features of the COVID-19 Infection: Comparison of the Initial and Follow-up Changes.

    abstract:OBJECTIVES:In late December 2019, an outbreak of coronavirus disease (COVID-19) in Wuhan, China was caused by a novel coronavirus, newly named severe acute respiratory syndrome coronavirus 2. We aimed to quantify the severity of COVID-19 infection on high-resolution chest computed tomography (CT) and to determine its r...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000674

    authors: Xiong Y,Sun D,Liu Y,Fan Y,Zhao L,Li X,Zhu W

    更新日期:2020-06-01 00:00:00

  • Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

    abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a56678

    authors: Vos EK,Sambandamurthy S,Kamel M,McKenney R,van Uden MJ,Hoeks CM,Yakar D,Scheenen TW,Fütterer JJ

    更新日期:2014-01-01 00:00:00

  • A qualitative investigation of turbulence in flow through a model abdominal aortic aneurysm.

    abstract:RATIONALE AND OBJECTIVES:As part of a general examination of the effect of blood flow patterns on the growth and risk of rupture of abdominal aortic aneurysms, the authors investigated the flow through an experimental model of a fusiform aneurysm. MATERIALS AND METHODS:Aneurysms were simulated in polyvinyl chloride tu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199207000-00008

    authors: Schrader T,Peattie RA,Bluth EI,Comstock CE

    更新日期:1992-07-01 00:00:00

  • Phantom testing of peripheral artery. Absolute blood flow measurement with digital arteriography.

    abstract::A technique to measure absolute arterial blood flow in ml/min has been developed utilizing software programs with high-speed digital recording for the off-line analysis of intra-arterial injections of contrast medium. Measurements of pulsatile flow in a phantom for a physical flow model showed that calculations with t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198503000-00017

    authors: Forbes G,Gray JE,Felmlee JP

    更新日期:1985-03-01 00:00:00

  • Structured Reporting of Rectal Magnetic Resonance Imaging in Suspected Primary Rectal Cancer: Potential Benefits for Surgical Planning and Interdisciplinary Communication.

    abstract:OBJECTIVES:The aim of this study was to evaluate the effect of structured reports (SRs) in comparison to nonstructured, free-text (FT) rectal magnetic resonance imaging (MRI) reports in patients with histologically proven rectal cancer and potential effects of both types of reporting on referring surgeons' satisfaction...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000336

    authors: Nörenberg D,Sommer WH,Thasler W,DʼHaese J,Rentsch M,Kolben T,Schreyer A,Rist C,Reiser M,Armbruster M

    更新日期:2017-04-01 00:00:00

  • Design of an isolated pig heart preparation for positron emission tomography and magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Validation of new positron emission tomography (PET) tracers or magnetic (MR) imaging contrast agents is based on isolated rodent heart preparations. The use of larger animals could provide a more direct validation using the devices used for humans. METHODS:An isolated pig heart preparation ha...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199711000-00010

    authors: Casali C,Obadia JF,Canet E,Bendjelid K,André-Fouët X,Revel D,Janier MF

    更新日期:1997-11-01 00:00:00