Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility.

Abstract:

OBJECTIVES:To test the technique and feasibility of translating tumor suspicious region maps in the prostate, obtained by multimodality, anatomic, and functional 3T magnetic resonance imaging (MRI) data to 32-channel coil, T2-weighted (T2-w), 3T MR images, for directing MR-guided biopsies. Furthermore, to evaluate the practicability of MR-guided biopsy on a 3T MR scanner using a 32-channel coil and a MR-compatible biopsy device. MATERIALS AND METHODS:Twenty-one patients with a high prostate-specific antigen (>4.0 ng/mL) and at least 2 prior negative transrectal ultrasound-guided biopsies of the prostate underwent an endorectal coil 3T MRI, which included T2-w, diffusion weighted and dynamic contrast enhanced MRI. From these multimodality images, tumor suspicious regions (TSR) were determined. The 3D localization of these TSRs within the prostatic gland was translated to the T2-w MR images of a subsequent 32-channel coil 3T MRI. These were then biopsied under 3T MR guidance. RESULTS:In all patients, TSRs could be identified and accurately translated to subsequent 3T MR images and biopsied under MR guidance. Median MR biopsy procedure time was 35 minutes. Of the 21 patients, 8 (38%) were diagnosed with prostate cancer, 6 (29%) had evidence of prostatitis, 6 (29%) had combined inflammatory and atrophic changes, and only 1 (5%) patient had no identifiable pathology. CONCLUSIONS:Multimodality, 3T MRI determined TSRs could effectively be translated to T2-weighted images, to be used for MR biopsies. 3T MR-guided biopsy based on these translated TSRs was feasible, performed in a clinical useful time, and resulted in a high number of positive results.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Hambrock T,Fütterer JJ,Huisman HJ,Hulsbergen-vandeKaa C,van Basten JP,van Oort I,Witjes JA,Barentsz JO

doi

10.1097/RLI.0b013e31817d0506

subject

Has Abstract

pub_date

2008-10-01 00:00:00

pages

686-94

issue

10

eissn

0020-9996

issn

1536-0210

pii

00004424-200810000-00002

journal_volume

43

pub_type

杂志文章
  • Selective catheterization for magnification angiography of internal spermatic and proper hepatic arteries in rabbits.

    abstract::A method is presented for selective catheterization and filming of the small internal spermatic and proper hepatic arteries in rabbits. The angiograms thus obtained afford clear delineation of the vessels and their branches and can enhance radiographic investigation of a variety of experimental disease models. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197705000-00009

    authors: Young S,Hollenberg NK

    更新日期:1977-05-01 00:00:00

  • Inhibition of restenosis in stented porcine coronary arteries: uptake of Paclitaxel from angiographic contrast media.

    abstract:RATIONALE AND OBJECTIVES:Paclitaxel added to angiographic contrast medium (CM) has been shown to inhibit restenosis in the porcine coronary overstretch model. This study determined early local tissue concentrations after the administration of different paclitaxel doses and preparations. MATERIALS AND METHODS:Fifteen p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000116125.96544.64

    authors: Speck U,Scheller B,Abramjuk C,Grossmann S,Mahnkopf D,Simon O

    更新日期:2004-03-01 00:00:00

  • CT Dosimetry: What Has Been Achieved and What Remains to Be Done.

    abstract::Radiation dose in computed tomography (CT) has become a hot topic due to an upward trend in the number of CT procedures worldwide and the relatively high doses associated with these procedures. The main aim of this review article is to provide an overview of the most frequently used metrics for CT radiation dose chara...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000727

    authors: Damilakis J

    更新日期:2021-01-01 00:00:00

  • A preliminary study of MRI quantification of simulated calcified pulmonary nodules.

    abstract::The potential of magnetic resonance imaging (MRI) quantification of calcium for the evaluation of pulmonary nodules was investigated in simulated nodules. Calcium salts do not contain mobile protons and thus have no signal on MR proton images. To determine whether the absence of signal from partially calcified nodules...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198711000-00001

    authors: Gamsu G,de Geer G,Cann C,Müller N,Brito A

    更新日期:1987-11-01 00:00:00

  • Fibroblast response to gadolinium: role for platelet-derived growth factor receptor.

    abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e943d2

    authors: Bhagavathula N,Dame MK,DaSilva M,Jenkins W,Aslam MN,Perone P,Varani J

    更新日期:2010-12-01 00:00:00

  • Does dilution of contrast media affect contrast enhancement? An experimental study in rats.

    abstract::The effect of contrast media (CM) dilution on contrast enhancement was studied using CM representing four structurally different molecular types at osmolalities ranging from 135 to 1340 mosm/kg. Diatrizoate (ionic monomer), iopamidol (nonionic monomer), ioxaglate (ionic dimer), and iodecol (nonionic dimer) were each g...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00014

    authors: Dean PB,Kivisaari L,Kormano M

    更新日期:1988-09-01 00:00:00

  • Characteristics of magnetic resonance sequences used for imaging silicone gel, saline, and gel-saline implants at low field strengths.

    abstract:RATIONALE AND OBJECTIVES:Low-field magnetic resonance imaging (MRI) evaluation of breast implants is described, with emphasis on the capabilities provided by different imaging sequences. METHODS:Open architecture MR images using a .064-T permanent magnet and three-dimensional Fourier transform and inversion recovery s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199408000-00009

    authors: Frankel S,Occhipinti K,Kaufman L,Kramer D,Carlson J,Mineyev M,Friedenthal R

    更新日期:1994-08-01 00:00:00

  • A method for the study of regional ischemic dysfunction in the intact dog. Permanent endocardial markers and the pressure-length loop.

    abstract::A radiographic method for use in the closed-chest dog is described which allows the quantitation of segmental mechanical performance. Previous work has shown that the area of the pressure-length loop (an approximation of a stress-strain integral) is a useful measure of the mechanical work performed by a segment of myo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197611000-00010

    authors: Ringertz HG,Carlsson E,Tyberg JV

    更新日期:1976-11-01 00:00:00

  • Human brain chemical shift imaging at age 60 to 90: analysis of the causes of the observed sex differences in brain metabolites.

    abstract:RATIONALE AND OBJECTIVES:To assess whether differences in cerebral atrophy and white matter lesions or in the presence of lactate and lipid signals can explain the observed differences in brain choline, creatine, and N-acetylaspartate levels between healthy elderly women and men. METHODS:In addition to standard magnet...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200110000-00005

    authors: Sijens PE,Den Heijer T,De Leeuw FE,De Groot JC,Achten E,Heijboer RJ,Hofman A,Breteler MM,Oudkerk M

    更新日期:2001-10-01 00:00:00

  • Low-Dose Characterization of Kidney Stones Using Spectral Detector Computed Tomography: An Ex Vivo Study.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of kidney stone composition analysis using spectral detector computed tomography scanner (SDCT) with normal- and low-dose imaging protocols. METHODS:A total of 154 stones harvested from nephrolithotripsy or nephrolithotomy with a known monocrystalline...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000468

    authors: Große Hokamp N,Salem J,Hesse A,Holz JA,Ritter M,Heidenreich A,Maintz D,Haneder S

    更新日期:2018-08-01 00:00:00

  • Reproducibility, accuracy, and predictors of accuracy for the detection of coronary atherosclerotic plaque composition by computed tomography: an ex vivo comparison to intravascular ultrasound.

    abstract:PURPOSE:To determine the reproducibility, accuracy, and predictors of accuracy of computed tomography (CT) angiography to detect and characterize coronary atherosclerotic plaque as compared with intravascular ultrasound. METHODS:Ten ex vivo human coronary arteries were imaged in a moving phantom by dual-source CT (col...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e0a541

    authors: van der Giessen AG,Toepker MH,Donelly PM,Bamberg F,Schlett CL,Raffle C,Irlbeck T,Lee H,van Walsum T,Maurovich-Horvat P,Gijsen FJ,Wentzel JJ,Hoffmann U

    更新日期:2010-11-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography of the carotid arteries: influence of injection rates and volumes on arterial-venous transit time.

    abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000105040.40925.c8

    authors: Herold T,Paetzel C,Völk M,Bachthaler M,Zorger N,Feuerbach S,Strotzer M,Lenhart M

    更新日期:2004-02-01 00:00:00

  • Effect of Age on High T1 Signal Intensity of the Dentate Nucleus and Globus Pallidus in a Large Population Exposed to Gadodiamide.

    abstract:OBJECTIVE:The purpose of this study was to assess the effect of age and number of previous injections of gadodiamide on the signal intensity of unenhanced T1-weighted (T1w) images of the dentate nucleus and globus pallidus in a large population. MATERIALS AND METHODS:A large, single-center retrospective population sur...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000431

    authors: Quattrocchi CC,Errante Y,Mallio CA,Marinelli L,LoVullo G,Giannotti G,Della Sala SW,van der Molen AJ,Beomonte Zobel B

    更新日期:2018-04-01 00:00:00

  • Fluorinated blood substitute retention in the rat measured by fluorine-19 magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199208000-00012

    authors: Meyer KL,Carvlin MJ,Mukherji B,Sloviter HA,Joseph PM

    更新日期:1992-08-01 00:00:00

  • Time course of satisfaction of search.

    abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199107000-00003

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Rooholamini SA,Coffman CE,Cornell SH,Cragg AH,Galvin JR,Honda H,Kao SC

    更新日期:1991-07-01 00:00:00

  • Right-Angled Traction Bronchiectasis in Differentiating Idiopathic Pulmonary Fibrosis Without Honeycombing From Idiopathic Nonspecific Interstitial Pneumonia.

    abstract:OBJECTIVES:The aim of this study was to conduct a radiopathologic evaluation of right-angled traction bronchiectasis to differentiate idiopathic pulmonary fibrosis (IPF) without honeycombing from idiopathic nonspecific interstitial pneumonia (NSIP). MATERIALS AND METHODS:The derivation cohort included 78 consecutive p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000651

    authors: Kim H,Yoon SH,Lee HJ,Song SG,Koh J,Jeon YK,Chae KJ,Jin GY,Jin KN,Lee KY,Goo JM

    更新日期:2020-06-01 00:00:00

  • 3 T contrast-enhanced magnetic resonance angiography for evaluation of the intracranial arteries: comparison with time-of-flight magnetic resonance angiography and multislice computed tomography angiography.

    abstract:PURPOSE:We sought to prospectively evaluate the image quality and visualization of the intracranial arteries using high spatial resolution contrast-enhanced magnetic resonance angiography (CE-MRA) at 3 T and to perform intraindividual comparison with time-of-flight (TOF) MRA and multislice CT angiography (CTA). MATERI...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.rli.0000242835.00032.f5

    authors: Villablanca JP,Nael K,Habibi R,Nael A,Laub G,Finn JP

    更新日期:2006-11-01 00:00:00

  • Correlation of Histological Vessel Characteristics and Diffusion-Weighted Imaging Intravoxel Incoherent Motion-Derived Parameters in Pancreatic Ductal Adenocarcinomas and Pancreatic Neuroendocrine Tumors.

    abstract:OBJECTIVE:To investigate the correlation between intravoxel incoherent motion (IVIM) model-derived parameters and histologically determined microvascularity in pancreatic ductal adenocarcinomas (PDACs) and pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:From April 2013 to May 2014, 42 patients with mal...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000187

    authors: Klau M,Mayer P,Bergmann F,Maier-Hein K,Hase J,Hackert T,Kauczor HU,Grenacher L,Stieltjes B

    更新日期:2015-11-01 00:00:00

  • Quantitative computed tomography of the lungs and airways in healthy nonsmoking adults.

    abstract:OBJECTIVES:The purposes of this study were to evaluate the reference range of quantitative computed tomography (QCT) measures of lung attenuation and airway parameter measurements in healthy nonsmoking adults and to identify sources of variation in those measures and possible means to adjust for them. MATERIALS AND ME...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318262292e

    authors: Zach JA,Newell JD Jr,Schroeder J,Murphy JR,Curran-Everett D,Hoffman EA,Westgate PM,Han MK,Silverman EK,Crapo JD,Lynch DA,COPDGene Investigators.

    更新日期:2012-10-01 00:00:00

  • Role of iodinated contrast material in the evaluation of myocardial infarction by computerized transmission tomography.

    abstract::In vivo and in vitro studies have shown that areas of myocardial infarctions can be delineated on CT scans after intravenous administration of iodinated contrast material to dogs with experimental myocardial infarctions. Within the first minute after intravenous administration of contrast material (initial myocardial ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00039

    authors: Higgins CB,Siemers PT,Newell JD,Schmidt W

    更新日期:1980-11-01 00:00:00

  • Retention of iodine and expression of biomarkers for renal damage in the kidney after application of iodinated contrast media in rats.

    abstract:OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318190fbd2

    authors: Jost G,Pietsch H,Sommer J,Sandner P,Lengsfeld P,Seidensticker P,Lehr S,Hütter J,Sieber MA

    更新日期:2009-02-01 00:00:00

  • Analysis of edge-tracking errors inherent in fluoroscopic images of the beating heart.

    abstract:RATIONALE AND OBJECTIVES:Because of the complex relationships between the dynamic three-dimensional cardiac surface shape and its projected image, errors arise with the use of two-dimensional silhouettes to measure displacements of the heart. The character and frequency of such errors are examined. METHODS:A high-prec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199403000-00004

    authors: McInerney JJ,Weldner PW,Herr MD,Copenhaver GL

    更新日期:1994-03-01 00:00:00

  • Constructing pre- and post-tests in a medical student elective.

    abstract::The importance of evaluating medical student performance has been widely addressed in the medical education literature. Multiple-choice examinations are the preferred method of testing because they are easy to administer and score. Development of parallel or equivalent pre- and post-examinations provides objective inf...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Blane CE,Calhoun JG,Vydareny KH

    更新日期:1986-09-01 00:00:00

  • Ultrasound-guided, percutaneous cryotherapy of small (< or = 15 mm) breast cancers.

    abstract:RATIONALE AND OBJECTIVE:The purpose of this study was to investigate the feasibility, efficacy, and safety of ultrasound-guided percutaneous cryotherapy of stage T1 breast cancers. MATERIALS AND METHODS:Thirty patients with biopsy-confirmed breast cancers with tumor diameters of 15 mm or smaller (range, 5-15 mm; media...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000166935.56971.ff

    authors: Pfleiderer SO,Marx C,Camara O,Gajda M,Kaiser WA

    更新日期:2005-07-01 00:00:00

  • Radiologist's responsibility in France when using contrast media.

    abstract::French physicians must obtain their patient's consent before carrying out an action that interferes with the patient's corporal integrity. The doctor must use simple, approximate, intelligent, and honest words that help the patient to reach the indispensable decision. Proof of lack of consent lies with the patient. Th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00006

    authors: Alméras JP,Husson R,Moreau JF

    更新日期:1988-09-01 00:00:00

  • MR characterization of mild hyperthermia-induced gadodiamide release from thermosensitive liposomes in solid tumors.

    abstract:OBJECTIVES:Thermal dose in tumor tissue is a key factor for regional hyperthermia (HT) combined with chemotherapy and for drug delivery using thermosensitive liposomes (TSL). It influences therapy outcome, affects the accumulation of liposomes, and triggers the content release from TSL in the target tissue. For the dev...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31818768cd

    authors: Peller M,Schwerdt A,Hossann M,Reinl HM,Wang T,Sourbron S,Ogris M,Lindner LH

    更新日期:2008-12-01 00:00:00

  • T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning.

    abstract:OBJECTIVES:The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. MATERIALS AND METHODS:Ten pat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000381

    authors: Freedman JN,Collins DJ,Bainbridge H,Rank CM,Nill S,Kachelrieß M,Oelfke U,Leach MO,Wetscherek A

    更新日期:2017-10-01 00:00:00

  • Evaluation of the integrity of the blood-brain barrier after meningeal trauma.

    abstract:RATIONALE AND OBJECTIVES:The authors used magnetic resonance imaging (MRI) techniques to examine the effect of meningeal trauma produced by cisterna magna puncture on the integrity of the blood-cerebrospinal fluid barrier (BCB) in a rat model. METHODS:Intravenous gadolinium-DTPA (Gd-DTPA), a relaxation rate modifier w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199204000-00008

    authors: Walker JD,Martin MA,Potts DG,Lemaire C,Templeton DM

    更新日期:1992-04-01 00:00:00

  • New contrast media in cerebral angiography: animal experiments and preliminary clinical studies.

    abstract::The cerebrovascular toxicity of three water-soluble contrast agents with a low hypertonicity (metrizamide, ioxaglate, iopamidol) was tested. Blood-brain barrier damage after carotid injection was assessed using 32P autoradiography and fluorescent microscopy after Evans blue staining. The damage to carotid endothelium ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00058

    authors: Gonsette RE,Liesenborgh L

    更新日期:1980-11-01 00:00:00

  • Radiolabeled leukocytes and platelets.

    abstract::Radiolabeled blood cells are widely used for both clinical and research studies. In vitro and in vivo studies have shown the tagging process does not significantly affect function. The labeling techniques and clinical uses of labeled leukocytes and platelets are reviewed. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198603000-00001

    authors: Datz FL

    更新日期:1986-03-01 00:00:00