Abstract:
PURPOSE:To determine the reproducibility, accuracy, and predictors of accuracy of computed tomography (CT) angiography to detect and characterize coronary atherosclerotic plaque as compared with intravascular ultrasound. METHODS:Ten ex vivo human coronary arteries were imaged in a moving phantom by dual-source CT (collimation: 0.6 mm, reconstructed slice thickness: 0.4 mm) and intravascular ultrasound (IVUS). Coregistered cross-sections were assessed at 0.4 mm intervals for the presence and composition of atherosclerotic plaque (noncalcified, mixed, and calcified) on CT and IVUS by independent readers to determine reader agreement and diagnostic accuracy. Quantitative measurements of lumen and plaque area, plaque eccentricity, and intimal thickness on IVUS were used to determine predictors for the detection of noncalcified plaque by CT. RESULTS:Within 1002 coregistered cross-sections, the interobserver agreement to detect plaque on CT was K = 0.48, K = 0.42, and K = 1.00 for noncalcified, mixed, and calcified plaque; respectively. The sensitivity and specificity of CT was 57% out of 84% for noncalcified, 32% of 92% for mixed, and 56% of 93% for calcified plaque when compared with IVUS; respectively. Misclassification occurred in 68% of mixed and 43% of noncalcified plaques. The odds of detecting noncalcified plaque in CT independently increased by 56% (95% CI: 47%-77%, P < 0.0001) with every 0.1 mm increase in maximum intimal thickness as measured by IVUS. Detection rate for noncalcified plaques was poor for plaques <1 mm (36%) but excellent for plaques >1 mm maximal intimal thickness (90%). CONCLUSION:Reader agreement and diagnostic accuracy for the detection of coronary atherosclerotic plaque vary with plaque composition. Intimal thickness independently predicts detection of noncalcified plaque by CT with excellent sensitivity for >1 mm thick plaques.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
van der Giessen AG,Toepker MH,Donelly PM,Bamberg F,Schlett CL,Raffle C,Irlbeck T,Lee H,van Walsum T,Maurovich-Horvat P,Gijsen FJ,Wentzel JJ,Hoffmann Udoi
10.1097/RLI.0b013e3181e0a541subject
Has Abstractpub_date
2010-11-01 00:00:00pages
693-701issue
11eissn
0020-9996issn
1536-0210journal_volume
45pub_type
杂志文章abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181e943d2
更新日期:2010-12-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a convention...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000459
更新日期:2018-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To determine whether vascular endothelial growth factor (VEGF) is a histopathological factor influencing contrast enhancement of hepatocellular carcinoma (HCC) on computed tomography (CT). METHODS:Twenty-two nodular HCCs underwent multiphase helical CT and surgery. Tumor size, histological gra...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200108000-00008
更新日期:2001-08-01 00:00:00
abstract::Early detection of pancreatic ductal adenocarcinoma (PDAC) represents the most significant step toward the treatment of this aggressive lethal disease. Previously, we engineered a preclinical Thy1-targeted microbubble (MBThy1) contrast agent that specifically recognizes Thy1 antigen overexpressed in the vasculature of...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000697
更新日期:2020-11-01 00:00:00
abstract::The authors correlated sonographic findings with histologic findings in a rabbit model of osteomyelitis. Staphylococcus aureus osteomyelitis was induced in the femora of 11 New Zealand white rabbits. The opposite leg was used as a control. Sonographic findings showed fluid adjacent to the bone in 11 cases. The fluid w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199202000-00002
更新日期:1992-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199903000-00014
更新日期:1999-03-01 00:00:00
abstract::The use of microbubble contrast agents for general tissue delineation and perfusion enjoys steady interest in ultrasound imaging. Microbubbles as contrast materials require a small dosage and show excellent detection sensitivity. Targeting ligands on the surface of microbubbles permit the selective accumulation of the...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/01.rli.0000199292.88189.0f
更新日期:2006-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Target-specific magnetic resonance (MR) contrast agents are being developed to improve the accuracy of MR imaging. The purpose of this study was to determine the mechanism of cell uptake, and modes of intracellular trafficking of a prototypical iron oxide label (RMA) used in the synthesis of so...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199510000-00006
更新日期:1995-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199704000-00008
更新日期:1997-04-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to assess the effect of age and number of previous injections of gadodiamide on the signal intensity of unenhanced T1-weighted (T1w) images of the dentate nucleus and globus pallidus in a large population. MATERIALS AND METHODS:A large, single-center retrospective population sur...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000431
更新日期:2018-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199410000-00005
更新日期:1994-10-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182a56678
更新日期:2014-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the short-term effects of a new nitinol stent on canine arteries. METHODS:Eighteen nitinol mesh stents were placed in abdominal aortas, common iliac arteries, and renal arteries of six dogs. Angiography was performed to evaluate the patency rates and structural changes of arteries ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199905000-00007
更新日期:1999-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors studied the long-term distribution of gadolinium (Gd) in mice and rats after the administration of four commercially available magnetic resonance imaging contrast media. The goals were to determine any possible product dissociation in vivo and to evaluate the effects that product ex...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199506000-00008
更新日期:1995-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To summarize the chemical synthesis, physicochemical characterization, pharmacokinetic behavior, and biological evaluation of P743, a new macromolecular iodinated contrast medium. METHODS:The synthesis and molecular modeling of the iodinated macromolecule P743 are described. The pharmacokineti...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200101000-00006
更新日期:2001-01-01 00:00:00
abstract:RATIONAL AND OBJECTIVES:The feasibility of tubal occlusion by selective salpingography was tested in an animal model; three novel occluding materials also were tested for this application. METHODS:Unilateral selective salpingography was performed in three groups of six rabbits; fallopian tubes were embolized with etha...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199402000-00007
更新日期:1994-02-01 00:00:00
abstract:OBJECTIVES:The aim of this pilot study was to assess post-treatment apparent diffusion coefficient (ADC) changes of diffuse large B-cell lymphoma lesions on respiratory-gated whole-body diffusion-weighted imaging (DWI), with integrated (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182087b03
更新日期:2011-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000133816.83192.38
更新日期:2004-09-01 00:00:00
abstract::A photographic unsharp masking technique for improving the latitude of chest radiographs without sacrificing image contrast or detail is described. An unsharp mask film, prepared from a scout film of the patient's chest, is placed between the film and the front (entrance) screen in the cassette. A second radiograph th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198107000-00007
更新日期:1981-07-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate the magnetic resonance prostate imaging reporting and data system (PI-RADS) for the detection of prostate cancer by the results of magnetic resonance imaging (MRI)-guided biopsy of the prostate as a reference standard. PATIENTS AND METHODS:In 55 patients who had underg...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000030
更新日期:2014-06-01 00:00:00
abstract:OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318190fbd2
更新日期:2009-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors studied the incidence and distribution of orthopedic injuries sustained in Operation Desert Shield and Desert Storm by evaluating whether existing diagnostic imaging modalities were sufficient to diagnose the types of musculoskeletal injuries incurred. The authors also sought to det...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199703000-00006
更新日期:1997-03-01 00:00:00
abstract::The Point Spread Function (PSF) in NMR imaging is the result of both the line broadening due to magnet field inhomogeneity and the intrinsic spectrum of the nucleus at resonance. In the case of proton imaging, the line broadening dominates the small chemical shifts and the spectral lines are not resolved. This is not ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198503000-00016
更新日期:1985-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/01.rli.0000105040.40925.c8
更新日期:2004-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the imaging characteristics of various iliac artery stents and stent-grafts in a multislice, computed tomography angiography (MSCTA) phantom study. METHODS:Twelve types of stents and three stent-grafts made of different materials (steel, nitinol, tantalum, cobalt-based alloy) were ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200112000-00004
更新日期:2001-12-01 00:00:00
abstract::In vitro incompatibilities between nine water-soluble contrast media and 21 intravascular pharmacologic agents were investigated using naked-eye observation and a centrifuge. Most of the previously reported incompatibilities were verified, and a few new incompatibilities were discovered: phentolamine mesylate with dia...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199201000-00008
更新日期:1992-01-01 00:00:00
abstract::Maximum likelihood estimation, assuming a binormal model, has been used extensively to estimate the area under receiver operating characteristic (ROC) curves and thus provide an index of diagnostic accuracy for the comparison of two imaging systems. However, in some instances, a degenerate data set results in a fitted...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199007000-00016
更新日期:1990-07-01 00:00:00
abstract::Video dilution technique (VDT) is currently performed in conjunction with routine cerebral angiography to determine carotid blood flow in humans. Preliminary results indicate that the blood flows (as a percentage of cardial output) of the common, internal, and external carotid arteries are 8.5%, 5.5%, and 3.0%, respec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198105000-00004
更新日期:1981-05-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to analyze the effect of dual-energy computed tomography (DECT) scanners and fluid characteristics on iodine quantification and to calculate the measurement variability range induced by those variables. METHODS:We performed an experimental phantom study with 4 mediastinal iodine ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000446
更新日期:2018-06-01 00:00:00
abstract:OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000163743.63063.9f
更新日期:2005-06-01 00:00:00