Reproducibility, accuracy, and predictors of accuracy for the detection of coronary atherosclerotic plaque composition by computed tomography: an ex vivo comparison to intravascular ultrasound.

Abstract:

PURPOSE:To determine the reproducibility, accuracy, and predictors of accuracy of computed tomography (CT) angiography to detect and characterize coronary atherosclerotic plaque as compared with intravascular ultrasound. METHODS:Ten ex vivo human coronary arteries were imaged in a moving phantom by dual-source CT (collimation: 0.6 mm, reconstructed slice thickness: 0.4 mm) and intravascular ultrasound (IVUS). Coregistered cross-sections were assessed at 0.4 mm intervals for the presence and composition of atherosclerotic plaque (noncalcified, mixed, and calcified) on CT and IVUS by independent readers to determine reader agreement and diagnostic accuracy. Quantitative measurements of lumen and plaque area, plaque eccentricity, and intimal thickness on IVUS were used to determine predictors for the detection of noncalcified plaque by CT. RESULTS:Within 1002 coregistered cross-sections, the interobserver agreement to detect plaque on CT was K = 0.48, K = 0.42, and K = 1.00 for noncalcified, mixed, and calcified plaque; respectively. The sensitivity and specificity of CT was 57% out of 84% for noncalcified, 32% of 92% for mixed, and 56% of 93% for calcified plaque when compared with IVUS; respectively. Misclassification occurred in 68% of mixed and 43% of noncalcified plaques. The odds of detecting noncalcified plaque in CT independently increased by 56% (95% CI: 47%-77%, P < 0.0001) with every 0.1 mm increase in maximum intimal thickness as measured by IVUS. Detection rate for noncalcified plaques was poor for plaques <1 mm (36%) but excellent for plaques >1 mm maximal intimal thickness (90%). CONCLUSION:Reader agreement and diagnostic accuracy for the detection of coronary atherosclerotic plaque vary with plaque composition. Intimal thickness independently predicts detection of noncalcified plaque by CT with excellent sensitivity for >1 mm thick plaques.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

van der Giessen AG,Toepker MH,Donelly PM,Bamberg F,Schlett CL,Raffle C,Irlbeck T,Lee H,van Walsum T,Maurovich-Horvat P,Gijsen FJ,Wentzel JJ,Hoffmann U

doi

10.1097/RLI.0b013e3181e0a541

subject

Has Abstract

pub_date

2010-11-01 00:00:00

pages

693-701

issue

11

eissn

0020-9996

issn

1536-0210

journal_volume

45

pub_type

杂志文章
  • Fibroblast response to gadolinium: role for platelet-derived growth factor receptor.

    abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e943d2

    authors: Bhagavathula N,Dame MK,DaSilva M,Jenkins W,Aslam MN,Perone P,Varani J

    更新日期:2010-12-01 00:00:00

  • Continuous Hepatic Arterial Multiphase Magnetic Resonance Imaging During Free-Breathing.

    abstract:PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a convention...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000459

    authors: Weiss J,Notohamiprodjo M,Taron J,Martirosian P,Nickel D,Bamberg F,Nikolaou K,Othman AE

    更新日期:2018-10-01 00:00:00

  • Hepatocellular carcinoma: correlation between vascular endothelial growth factor level and degree of enhancement by multiphase contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:To determine whether vascular endothelial growth factor (VEGF) is a histopathological factor influencing contrast enhancement of hepatocellular carcinoma (HCC) on computed tomography (CT). METHODS:Twenty-two nodular HCCs underwent multiphase helical CT and surgery. Tumor size, histological gra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200108000-00008

    authors: Kwak BK,Shim HJ,Park ES,Kim SA,Choi D,Lim HK,Park CK,Chung JW,Park JH

    更新日期:2001-08-01 00:00:00

  • Toward the Clinical Development and Validation of a Thy1-Targeted Ultrasound Contrast Agent for the Early Detection of Pancreatic Ductal Adenocarcinoma.

    abstract::Early detection of pancreatic ductal adenocarcinoma (PDAC) represents the most significant step toward the treatment of this aggressive lethal disease. Previously, we engineered a preclinical Thy1-targeted microbubble (MBThy1) contrast agent that specifically recognizes Thy1 antigen overexpressed in the vasculature of...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000697

    authors: Bam R,Daryaei I,Abou-Elkacem L,Vilches-Moure JG,Meuillet EJ,Lutz A,Marinelli ER,Unger EC,Gambhir SS,Paulmurugan R

    更新日期:2020-11-01 00:00:00

  • Ultrasonic detection of osteomyelitis. Pathologic correlation in an animal model.

    abstract::The authors correlated sonographic findings with histologic findings in a rabbit model of osteomyelitis. Staphylococcus aureus osteomyelitis was induced in the femora of 11 New Zealand white rabbits. The opposite leg was used as a control. Sonographic findings showed fluid adjacent to the bone in 11 cases. The fluid w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00002

    authors: Abiri MM,DeAngelis GA,Kirpekar M,Abou AN,Ablow RC

    更新日期:1992-02-01 00:00:00

  • MRI dosimetry: a fast quantitative MRI method to determine 3D absorbed dose distributions.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199903000-00014

    authors: Calmet C,Vincensini D,Bonnet J,Bertino C,Catala A,Martinez M,Joffre F

    更新日期:1999-03-01 00:00:00

  • Microbubble contrast agents: targeted ultrasound imaging and ultrasound-assisted drug-delivery applications.

    abstract::The use of microbubble contrast agents for general tissue delineation and perfusion enjoys steady interest in ultrasound imaging. Microbubbles as contrast materials require a small dosage and show excellent detection sensitivity. Targeting ligands on the surface of microbubbles permit the selective accumulation of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/01.rli.0000199292.88189.0f

    authors: Klibanov AL

    更新日期:2006-03-01 00:00:00

  • Cellular uptake and trafficking of a prototypical magnetic iron oxide label in vitro.

    abstract:RATIONALE AND OBJECTIVES:Target-specific magnetic resonance (MR) contrast agents are being developed to improve the accuracy of MR imaging. The purpose of this study was to determine the mechanism of cell uptake, and modes of intracellular trafficking of a prototypical iron oxide label (RMA) used in the synthesis of so...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199510000-00006

    authors: Schulze E,Ferrucci JT Jr,Poss K,Lapointe L,Bogdanova A,Weissleder R

    更新日期:1995-10-01 00:00:00

  • Technical feasibility and performance studies of a 0.009-inch nitinol microguidewire for potential neuroendovascular applications.

    abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199704000-00008

    authors: Putman CM,Chaloupka JC,Kailasnath P,Alderman J

    更新日期:1997-04-01 00:00:00

  • Effect of Age on High T1 Signal Intensity of the Dentate Nucleus and Globus Pallidus in a Large Population Exposed to Gadodiamide.

    abstract:OBJECTIVE:The purpose of this study was to assess the effect of age and number of previous injections of gadodiamide on the signal intensity of unenhanced T1-weighted (T1w) images of the dentate nucleus and globus pallidus in a large population. MATERIALS AND METHODS:A large, single-center retrospective population sur...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000431

    authors: Quattrocchi CC,Errante Y,Mallio CA,Marinelli L,LoVullo G,Giannotti G,Della Sala SW,van der Molen AJ,Beomonte Zobel B

    更新日期:2018-04-01 00:00:00

  • Binary nature and radiographic identifiability of craniosynostosis.

    abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199410000-00005

    authors: Pilgram TK,Vannier MW,Marsh JL,Kraemer BB,Rayne SC,Gado MH,Moran CJ,McAlister WH,Shackelford GD,Hardesty RA

    更新日期:1994-10-01 00:00:00

  • Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

    abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a56678

    authors: Vos EK,Sambandamurthy S,Kamel M,McKenney R,van Uden MJ,Hoeks CM,Yakar D,Scheenen TW,Fütterer JJ

    更新日期:2014-01-01 00:00:00

  • Short-term effects of a new intravascular nitinol stent in canine arteries.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the short-term effects of a new nitinol stent on canine arteries. METHODS:Eighteen nitinol mesh stents were placed in abdominal aortas, common iliac arteries, and renal arteries of six dogs. Angiography was performed to evaluate the patency rates and structural changes of arteries ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199905000-00007

    authors: Lee KW,Park JH,Chung JW,Kim WS,Lee W,Yeon KM

    更新日期:1999-05-01 00:00:00

  • Biodistribution of radiolabeled, formulated gadopentetate, gadoteridol, gadoterate, and gadodiamide in mice and rats.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the long-term distribution of gadolinium (Gd) in mice and rats after the administration of four commercially available magnetic resonance imaging contrast media. The goals were to determine any possible product dissociation in vivo and to evaluate the effects that product ex...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199506000-00008

    authors: Tweedle MF,Wedeking P,Kumar K

    更新日期:1995-06-01 00:00:00

  • Preclinical profile of the monodisperse iodinated macromolecular blood pool agent P743.

    abstract:RATIONALE AND OBJECTIVES:To summarize the chemical synthesis, physicochemical characterization, pharmacokinetic behavior, and biological evaluation of P743, a new macromolecular iodinated contrast medium. METHODS:The synthesis and molecular modeling of the iodinated macromolecule P743 are described. The pharmacokineti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200101000-00006

    authors: Idée JM,Port M,Robert P,Raynal I,Prigent P,Dencausse A,Le Greneur S,Tichkowsky I,Le Lem G,Bourrinet P,Mugel T,Benderbous S,Devoldere L,Bourbouze R,Meyer D,Bonnemain B,Corot C

    更新日期:2001-01-01 00:00:00

  • Tubal sterilization by selective catheterization in an animal model.

    abstract:RATIONAL AND OBJECTIVES:The feasibility of tubal occlusion by selective salpingography was tested in an animal model; three novel occluding materials also were tested for this application. METHODS:Unilateral selective salpingography was performed in three groups of six rabbits; fallopian tubes were embolized with etha...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199402000-00007

    authors: Maubon A,Rouanet JP,Laurent A,Joujoux JM,Cover S,Courtieu C,Wassef M,Godlewski G,Honiger J,Lopez FM

    更新日期:1994-02-01 00:00:00

  • Whole-body diffusion-weighted imaging with apparent diffusion coefficient mapping for treatment response assessment in patients with diffuse large B-cell lymphoma: pilot study.

    abstract:OBJECTIVES:The aim of this pilot study was to assess post-treatment apparent diffusion coefficient (ADC) changes of diffuse large B-cell lymphoma lesions on respiratory-gated whole-body diffusion-weighted imaging (DWI), with integrated (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182087b03

    authors: Lin C,Itti E,Luciani A,Zegai B,Lin SJ,Kuhnowski F,Pigneur F,Gaillard I,Paone G,Meignan M,Haioun C,Rahmouni A

    更新日期:2011-05-01 00:00:00

  • Semiquantitative assessment of myocardial perfusion using magnetic resonance imaging: evaluation of appropriate thresholds and segmentation models.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000133816.83192.38

    authors: Fenchel M,Kramer U,Helber U,Stauder NI,Franow A,Claussen CD,Miller S

    更新日期:2004-09-01 00:00:00

  • Photographic unsharp masking in chest radiography.

    abstract::A photographic unsharp masking technique for improving the latitude of chest radiographs without sacrificing image contrast or detail is described. An unsharp mask film, prepared from a scout film of the patient's chest, is placed between the film and the front (entrance) screen in the cassette. A second radiograph th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198107000-00007

    authors: Sorenson JA,Niklason LT,Nelson JA

    更新日期:1981-07-01 00:00:00

  • Evaluation of the prostate imaging reporting and data system for the detection of prostate cancer by the results of targeted biopsy of the prostate.

    abstract:PURPOSE:The purpose of this study was to evaluate the magnetic resonance prostate imaging reporting and data system (PI-RADS) for the detection of prostate cancer by the results of magnetic resonance imaging (MRI)-guided biopsy of the prostate as a reference standard. PATIENTS AND METHODS:In 55 patients who had underg...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000030

    authors: Baur AD,Maxeiner A,Franiel T,Kilic E,Huppertz A,Schwenke C,Hamm B,Durmus T

    更新日期:2014-06-01 00:00:00

  • Retention of iodine and expression of biomarkers for renal damage in the kidney after application of iodinated contrast media in rats.

    abstract:OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318190fbd2

    authors: Jost G,Pietsch H,Sommer J,Sandner P,Lengsfeld P,Seidensticker P,Lehr S,Hütter J,Sieber MA

    更新日期:2009-02-01 00:00:00

  • Incidence and methods of diagnosis of musculoskeletal injuries incurred in Operations Desert Shield and Desert Storm.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the incidence and distribution of orthopedic injuries sustained in Operation Desert Shield and Desert Storm by evaluating whether existing diagnostic imaging modalities were sufficient to diagnose the types of musculoskeletal injuries incurred. The authors also sought to det...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199703000-00006

    authors: Truax AL,Chandnani VP,Chacko AK,Gonzalez DM

    更新日期:1997-03-01 00:00:00

  • Imaging of complex NMR spectra.

    abstract::The Point Spread Function (PSF) in NMR imaging is the result of both the line broadening due to magnet field inhomogeneity and the intrinsic spectrum of the nucleus at resonance. In the case of proton imaging, the line broadening dominates the small chemical shifts and the spectral lines are not resolved. This is not ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198503000-00016

    authors: Harrison CG,Adams DF,Kramer PB

    更新日期:1985-03-01 00:00:00

  • Contrast-enhanced magnetic resonance angiography of the carotid arteries: influence of injection rates and volumes on arterial-venous transit time.

    abstract:RATIONALE AND OBJECTIVES:To assess the influence of injection rates and volumes on the arrival time of contrast material (CM) in the common carotid artery, the jugular vein and the resulting arterial-venous transit time. Additionally the relationship between injection parameters and the extent of a CM plateau was evalu...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000105040.40925.c8

    authors: Herold T,Paetzel C,Völk M,Bachthaler M,Zorger N,Feuerbach S,Strotzer M,Lenhart M

    更新日期:2004-02-01 00:00:00

  • Multislice CT angiography of the iliac arteries in the presence of various stents: in vitro evaluation of artifacts and lumen visibility.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the imaging characteristics of various iliac artery stents and stent-grafts in a multislice, computed tomography angiography (MSCTA) phantom study. METHODS:Twelve types of stents and three stent-grafts made of different materials (steel, nitinol, tantalum, cobalt-based alloy) were ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200112000-00004

    authors: Maintz D,Fischbach R,Juergens KU,Allkemper T,Wessling J,Heindel W

    更新日期:2001-12-01 00:00:00

  • Incompatibility of water-soluble contrast media and intravascular pharmacologic agents. An in vitro study.

    abstract::In vitro incompatibilities between nine water-soluble contrast media and 21 intravascular pharmacologic agents were investigated using naked-eye observation and a centrifuge. Most of the previously reported incompatibilities were verified, and a few new incompatibilities were discovered: phentolamine mesylate with dia...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199201000-00008

    authors: Kim SH,Lee HK,Han MC

    更新日期:1992-01-01 00:00:00

  • Nonparametric estimation of degenerate ROC data sets used for comparison of imaging systems.

    abstract::Maximum likelihood estimation, assuming a binormal model, has been used extensively to estimate the area under receiver operating characteristic (ROC) curves and thus provide an index of diagnostic accuracy for the comparison of two imaging systems. However, in some instances, a degenerate data set results in a fitted...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199007000-00016

    authors: Rockette HE,Obuchowski NA,Gur D

    更新日期:1990-07-01 00:00:00

  • Assessment of cerebral blood flow in man by video dilution technique: a preliminary report.

    abstract::Video dilution technique (VDT) is currently performed in conjunction with routine cerebral angiography to determine carotid blood flow in humans. Preliminary results indicate that the blood flows (as a percentage of cardial output) of the common, internal, and external carotid arteries are 8.5%, 5.5%, and 3.0%, respec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198105000-00004

    authors: Lantz BM,Dublin AB,McGahan JP,Link DP

    更新日期:1981-05-01 00:00:00

  • Comparison of Iodine Density Measurement Among Dual-Energy Computed Tomography Scanners From 3 Vendors.

    abstract:OBJECTIVES:The aims of this study were to analyze the effect of dual-energy computed tomography (DECT) scanners and fluid characteristics on iodine quantification and to calculate the measurement variability range induced by those variables. METHODS:We performed an experimental phantom study with 4 mediastinal iodine ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000446

    authors: Kim H,Goo JM,Kang CK,Chae KJ,Park CM

    更新日期:2018-06-01 00:00:00

  • Potential of dose reduction after marker placement with full-field digital mammography.

    abstract:OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000163743.63063.9f

    authors: Riedl CC,Jaromi S,Floery D,Pfarl G,Fuchsjaeger MH,Helbich TH

    更新日期:2005-06-01 00:00:00