Preclinical profile of the monodisperse iodinated macromolecular blood pool agent P743.

Abstract:

RATIONALE AND OBJECTIVES:To summarize the chemical synthesis, physicochemical characterization, pharmacokinetic behavior, and biological evaluation of P743, a new macromolecular iodinated contrast medium. METHODS:The synthesis and molecular modeling of the iodinated macromolecule P743 are described. The pharmacokinetic profile was established in rabbits and rats. Acute toxicity in mice, renal tolerance in normal rabbits, and renal tolerance in uninephrectomized, dehydrated rats undergoing selective intrarenal injection was evaluated. In vitro permeability effects on isolated mastocytes and on the coagulation pathways were carried out. Computed tomography vascular imaging was performed after intravenous injection of P743 (300 mg I/kg) in rabbits and compared with the nonspecific nonionic agent iobitridol. RESULTS:P743 is a monodisperse, macromolecular iodinated contrast medium. In both rabbits and rats, P743 showed a pharmacokinetic profile consistent with that of a rapid-clearance blood-pool agent. Its diffusion through the endothelium was found to be low in vitro, thus confirming early confinement of this macromolecule, unlike nonspecific contrast media. In both species, P743 was excreted by glomerular filtration. Acute toxicity disclosed no mortality at the highest volume that could be injected into mice, leading to a median lethal dose greater than 8.9 g I/kg. Renal tolerance was found to be good in both euvolemic rabbits and uninephrectomized, dehydrated rats. No histamine or leukotriene B4 release was found on RBL-2H3 isolated mastocytes. P743 did not interfere with the coagulation pathways. Imaging experiments confirmed that P743 remains in the vascular compartment for a longer time than does iobitridol, thus allowing vascular enhancement that is twice as high as that of iobitridol in the recirculation phase. CONCLUSIONS:The pharmacokinetic and imaging profiles of P743, a new, monodisperse, macromolecular blood-pool iodinated contrast medium, were consistent with those of a rapid-clearance blood-pool agent. Its initial safety profile is satisfactory. Further experimental imaging studies are required to define the clinical interest in such molecules.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Idée JM,Port M,Robert P,Raynal I,Prigent P,Dencausse A,Le Greneur S,Tichkowsky I,Le Lem G,Bourrinet P,Mugel T,Benderbous S,Devoldere L,Bourbouze R,Meyer D,Bonnemain B,Corot C

doi

10.1097/00004424-200101000-00006

keywords:

subject

Has Abstract

pub_date

2001-01-01 00:00:00

pages

41-9

issue

1

eissn

0020-9996

issn

1536-0210

journal_volume

36

pub_type

杂志文章
  • Evaluation of iron content in human cerebral cavernous malformation using quantitative susceptibility mapping.

    abstract:OBJECTIVES:The aims of this study were to investigate and validate quantitative susceptibility mapping (QSM) for lesional iron quantification in cerebral cavernous malformations (CCMs). MATERIALS AND METHODS:Magnetic resonance imaging studies were performed in phantoms and 16 patients on a 3-T scanner. Susceptibility ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000043

    authors: Tan H,Liu T,Wu Y,Thacker J,Shenkar R,Mikati AG,Shi C,Dykstra C,Wang Y,Prasad PV,Edelman RR,Awad IA

    更新日期:2014-07-01 00:00:00

  • Evaluation of the dehydration-rehydration method for production of contrast-carrying liposomes.

    abstract::We measured the amounts of three types of radiographic contrast media (RCM) that could be entrapped in liposomes prepared by the dehydration-rehydration vesicle (DRV) technique. To make DRVs, one initially makes water-containing, small unilamellar vesicles, adds contrast media and lyophilizes the mixture. Upon rehydra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198802000-00009

    authors: Seltzer SE,Gregoriadis G,Dick R

    更新日期:1988-02-01 00:00:00

  • Accuracy of ultrasound in fetal femur length determination. Ultrasound phantom study.

    abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00016

    authors: Gamba JL,Bowie JD,Dodson WC,Hedlund LW

    更新日期:1985-05-01 00:00:00

  • Pharmacologic treatment of intimal hyperplasia after metallic stent placement in the peripheral arteries. An experimental study.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the efficacy of oral administration of cilostazol, an antithrombotic agent, for the prevention of thrombotic occlusion and intimal hyperplasia after stenting. METHODS:Single-bodied Z-stents were placed in the iliac arteries of 23 dogs. Before stenting, an embolizing coil was introd...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199509000-00004

    authors: Kubota Y,Kichikawa K,Uchida H,Maeda M,Nishimine K,Makutani S,Sakaguchi S,Yoshioka T,Ohishi H,Kimura Y

    更新日期:1995-09-01 00:00:00

  • Retention of iodine and expression of biomarkers for renal damage in the kidney after application of iodinated contrast media in rats.

    abstract:OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318190fbd2

    authors: Jost G,Pietsch H,Sommer J,Sandner P,Lengsfeld P,Seidensticker P,Lehr S,Hütter J,Sieber MA

    更新日期:2009-02-01 00:00:00

  • The mini-fellowship in teaching. A senior resident elective.

    abstract::The residency program at the University of Pennsylvania offers a 1-month fellowship for senior residents in medical student education. Instructional philosophy, methods, and content are discussed, observed, practiced, and evaluated. Close supervision and immediate feedback provide training particularly needed by futur...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199006000-00028

    authors: Troupin RH

    更新日期:1990-06-01 00:00:00

  • Computerized case-based instructional system for computed tomography and magnetic resonance imaging of brain tumors.

    abstract:RATIONALE AND OBJECTIVES:A computerized system that applies the case-based approach to training radiologists to diagnose brain tumors was designed. The authors attempted to provide residents a tool that supports their visual memory and inducts case-based reasoning. METHODS:A relational database with a digital image li...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199404000-00020

    authors: Macura RT,Macura KJ,Toro VE,Binet EF,Trueblood JH,Ji K

    更新日期:1994-04-01 00:00:00

  • Comparison of Routine Brain Imaging at 3 T and 7 T.

    abstract:OBJECTIVE:The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating dis...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000256

    authors: Springer E,Dymerska B,Cardoso PL,Robinson SD,Weisstanner C,Wiest R,Schmitt B,Trattnig S

    更新日期:2016-08-01 00:00:00

  • Selective catheterization for magnification angiography of internal spermatic and proper hepatic arteries in rabbits.

    abstract::A method is presented for selective catheterization and filming of the small internal spermatic and proper hepatic arteries in rabbits. The angiograms thus obtained afford clear delineation of the vessels and their branches and can enhance radiographic investigation of a variety of experimental disease models. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197705000-00009

    authors: Young S,Hollenberg NK

    更新日期:1977-05-01 00:00:00

  • Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.

    abstract:PURPOSE:The purpose of this study was to evaluate image quality of a spectral photon-counting detector (PCD) computed tomography (CT) system for evaluation of major arteries of the head and neck compared with conventional single-energy CT scans using energy-integrating detectors (EIDs). METHODS:In this institutional r...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000418

    authors: Symons R,Reich DS,Bagheri M,Cork TE,Krauss B,Ulzheimer S,Kappler S,Bluemke DA,Pourmorteza A

    更新日期:2018-03-01 00:00:00

  • Contrast media tonicity. Part I. Effects upon IV-DSA time-concentration curve peak and width: experimental studies.

    abstract::Prior to the formation of an intravenous digital subtraction angiography (IV-DSA) image, contrast medium passes through the lesser circulation and is diluted by the blood volume of the heart and lungs. If the contrast medium alone influences central blood volume or cardiac output, the shape of the resultant time-conce...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198603000-00009

    authors: Burbank FH,Thompson WM

    更新日期:1986-03-01 00:00:00

  • Human brain chemical shift imaging at age 60 to 90: analysis of the causes of the observed sex differences in brain metabolites.

    abstract:RATIONALE AND OBJECTIVES:To assess whether differences in cerebral atrophy and white matter lesions or in the presence of lactate and lipid signals can explain the observed differences in brain choline, creatine, and N-acetylaspartate levels between healthy elderly women and men. METHODS:In addition to standard magnet...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200110000-00005

    authors: Sijens PE,Den Heijer T,De Leeuw FE,De Groot JC,Achten E,Heijboer RJ,Hofman A,Breteler MM,Oudkerk M

    更新日期:2001-10-01 00:00:00

  • Feasibility of real-time magnetic resonance-guided angioplasty and stenting of renal arteries in vitro and in Swine, using a new polyetheretherketone-based magnetic resonance-compatible guidewire.

    abstract:OBJECTIVES:Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. MATERIAL AND METHODS:The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft ti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31819b00f1

    authors: Kos S,Huegli R,Hofmann E,Quick HH,Kuehl H,Aker S,Kaiser GM,Borm PJ,Jacob AL,Bilecen D

    更新日期:2009-04-01 00:00:00

  • Investigation of 125I as an isotopic source for mammography.

    abstract::An isotopic radiation source 125I was investigated for use in soft tissue radiaography, with particular attention to possible use in mammography for mass screening. Film sensitivities, exposure rates, absorbed doeses, contrast and resolution were determined, and compared to conventional x-ray units. It was found that ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197509000-00007

    authors: Fairchild R,Atkins HL,Lebowitz E,Greenberg D

    更新日期:1975-09-01 00:00:00

  • Nonenhanced magnetic resonance angiography of the lower extremity vessels at 7 tesla: initial experience.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of nonenhanced magnetic resonance angiography (MRA) of the lower extremities at 7 tesla (T). MATERIALS AND METHODS:Eight healthy volunteers were examined on a 7-T whole-body magnetic resonance system. For image acquisition, a custom-built 16-channel t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182839c2b

    authors: Fischer A,Maderwald S,Orzada S,Johst S,Schäfer LC,Ladd ME,Nassenstein K,Umutlu L,Lauenstein TC

    更新日期:2013-07-01 00:00:00

  • Combined methods for assessment of neurotoxicity: testing of new nonionic radiographic media.

    abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00053

    authors: Sovak M,Siefert HM,Ranganathan R

    更新日期:1980-11-01 00:00:00

  • Evaluation of the integrity of the blood-brain barrier after meningeal trauma.

    abstract:RATIONALE AND OBJECTIVES:The authors used magnetic resonance imaging (MRI) techniques to examine the effect of meningeal trauma produced by cisterna magna puncture on the integrity of the blood-cerebrospinal fluid barrier (BCB) in a rat model. METHODS:Intravenous gadolinium-DTPA (Gd-DTPA), a relaxation rate modifier w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199204000-00008

    authors: Walker JD,Martin MA,Potts DG,Lemaire C,Templeton DM

    更新日期:1992-04-01 00:00:00

  • Noninvasive estimation of organ weights by postmortem magnetic resonance imaging and multislice computed tomography.

    abstract:OBJECTIVE:Computed tomography (CT) and magnetic resonance imaging (MRI) are introduced as an alternative to traditional autopsy. The purpose of this study was to investigate their accuracy in mass estimation of liver and spleen. METHODS:In 44 cases, the weights of spleen and liver were estimated based on MRI and CT da...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000221323.38443.8d

    authors: Jackowski C,Thali MJ,Buck U,Aghayev E,Sonnenschein M,Yen K,Dirnhofer R,Vock P

    更新日期:2006-07-01 00:00:00

  • Necrotic areas in VX2 carcinoma of rabbits. Correlation of magnetic resonance imaging and pathologic appearance.

    abstract:RATIONALE AND OBJECTIVES:To assess the potential of magnetic resonance imaging (MRI) for evaluating the evolution of tumor necrosis, the authors evaluated 28 VX2 carcinomas inoculated in the thigh muscles of rabbits. METHODS:MRI of VX2 carcinomas at 2.0 T was done with spin-echo technique 1 week (14 tumors) and 3 week...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199301000-00010

    authors: Choi BI,Lee DH,Han MC

    更新日期:1993-01-01 00:00:00

  • Ultrasound analysis of tongue, hyoid, and larynx activity during swallowing.

    abstract::Using real-time ultrasound, the motions of the tongue, hyoid bone, and larynx were monitored and timed during swallowing in ten normal subjects. A well-defined propulsive wave of the tongue was observed during swallowing a 5-cc water bolus. The body of the hyoid bone was identified on the ultrasound scan as a high ech...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198403000-00003

    authors: Shawker TH,Sonies B,Hall TE,Baum BF

    更新日期:1984-03-01 00:00:00

  • Hardcopy recording technologies for digitally formatted image data.

    abstract::The hardcopy recording technologies of video cameras, slow-scan (digital spot) recorders, and laser film printers are presented and compared. Slow-scan (digital spot) recorders offer a few advantages when compared with multiformat video cameras. But only laser film printers provide the high-quality hardcopy recordings...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199102000-00017

    authors: Siegel EL,Bishop MD,Wetzel LH,Anderson WF,McMillan JH

    更新日期:1991-02-01 00:00:00

  • Advances in magnetic resonance (2006).

    abstract::Advances in the field of magnetic resonance (MR) as it pertains to clinical diagnostic radiology are examined in this review on the basis of publications in Investigative Radiology over the past 2 years (2005-2006). The articles published during that timeframe are discussed, organizationally wise, by anatomic region w...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/01.rli.0000250461.03245.5c

    authors: Runge VM

    更新日期:2006-12-01 00:00:00

  • Delayed Gadolinium Leakage in Ocular Structures: A Potential Marker for Age- and Vascular Risk Factor-Related Small Vessel Disease?

    abstract:BACKGROUND:Gadolinium leakage in ocular structures (GLOS) was recently observed in fluid-attenuated inversion recovery (FLAIR) images obtained the day after an initial gadolinium injection in stroke patients. The specificity of GLOS to stroke and its mechanisms remain unclear. OBJECTIVE:We investigated the factors ass...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000757

    authors: Galmiche C,Moal B,Marnat G,Sagnier S,Schweitzer C,Dousset V,Sibon I,Tourdias T

    更新日期:2021-01-19 00:00:00

  • Evaluation of Gd-EOB-DTPA uptake in a perfused and isolated mouse liver model: correlation between magnetic resonance imaging and monochromatic quantitative computed tomography.

    abstract:OBJECTIVES:The aim of this work was to quantitatively evaluate the pharmacokinetic pattern of Gd-EOB-DTPA in a model of isolated and perfused mouse liver by using magnetic resonance imaging (MRI) and monochromatic quantitative computed tomography (MQCT). MATERIALS AND METHODS:For MQCT, perfusions were realized with th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000174474.43772.58

    authors: Segers J,Le Duc G,Laumonier C,Troprès I,Elst LV,Muller RN

    更新日期:2005-09-01 00:00:00

  • Hybrid Positron Emission Tomography/Magnetic Resonance Imaging: Challenges, Methods, and State of the Art of Hardware Component Attenuation Correction.

    abstract::Attenuation correction (AC) is an essential step in the positron emission tomography (PET) data reconstruction process to provide accurate and quantitative PET images. The introduction of PET/magnetic resonance (MR) hybrid systems has raised new challenges but also possibilities regarding PET AC. While in PET/computed...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000289

    authors: Paulus DH,Quick HH

    更新日期:2016-10-01 00:00:00

  • The night stalker effect: quality improvements with a dedicated night-call rotation.

    abstract:RATIONALE AND OBJECTIVES:The authors assessed whether a non-sleep-deprived, second-year diagnostic radiology resident assigned to an after-hours "night stalker" emergency radiology (ER) rotation in an urban university hospital has a measurable impact on the number and clinical significance of "missed" radiologic findin...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199301000-00032

    authors: Mann FA,Danz PL

    更新日期:1993-01-01 00:00:00

  • Incidence and methods of diagnosis of musculoskeletal injuries incurred in Operations Desert Shield and Desert Storm.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the incidence and distribution of orthopedic injuries sustained in Operation Desert Shield and Desert Storm by evaluating whether existing diagnostic imaging modalities were sufficient to diagnose the types of musculoskeletal injuries incurred. The authors also sought to det...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199703000-00006

    authors: Truax AL,Chandnani VP,Chacko AK,Gonzalez DM

    更新日期:1997-03-01 00:00:00

  • Increased ablation zones using a cryo-based internally cooled bipolar RF applicator in ex vivo bovine liver.

    abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b66d11

    authors: Rempp H,Voigtländer M,Clasen S,Kempf S,Neugebauer A,Schraml C,Schmidt D,Claussen CD,Enderle MD,Goldberg SN,Pereira PL

    更新日期:2009-12-01 00:00:00

  • Some practical issues of experimental design and data analysis in radiological ROC studies.

    abstract::Receiver operating characteristic (ROC) analysis has been used in a broad variety of medical imaging studies during the past 15 years, and its advantages over more traditional measures of diagnostic performance are now clearly established. But despite the essential simplicity of the approach, workers in the field ofte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198903000-00012

    authors: Metz CE

    更新日期:1989-03-01 00:00:00

  • Radiologist's responsibility in France when using contrast media.

    abstract::French physicians must obtain their patient's consent before carrying out an action that interferes with the patient's corporal integrity. The doctor must use simple, approximate, intelligent, and honest words that help the patient to reach the indispensable decision. Proof of lack of consent lies with the patient. Th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00006

    authors: Alméras JP,Husson R,Moreau JF

    更新日期:1988-09-01 00:00:00