Abstract:
OBJECTIVES:Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. MATERIAL AND METHODS:The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft tip, and a hydrophilic coating was used. Paramagnetic markings were coated on the wire and nonbraided catheters for passive visualization. Bending stiffness of the guidewire was compared with available hydrophilic guidewires (Terumo Glidewire Stiff and Standard). A human aortic silicon phantom and 2 pigs were used. The study was animal care and use approved by the committee. Under MR-guidance, renal arteries were catheterized, balloon angioplasty was performed, and balloon expandable renal artery stents were deployed in vivo. Post mortem autopsy was performed. Guidewire visibility, pushability, steerability, and device-support capabilities of the marked guidewire were qualitatively assessed. Procedure times were recorded. RESULTS:Bending stiffness of the new PEEK-based wire was comparable with Standard Glidewire. In vitro and in vivo guidewire guidance, catheter configuration, renal artery catheterization, and balloon angioplasty were successful. In pigs, stent deployments were successful in both renal arteries. Autopsy revealed acceptable stent positioning. Guidewire visibility through applied markers was acceptable. Steerability, pushability, and device support were good in vitro and in vivo. CONCLUSIONS:The PEEK-based guide allows percutaneous MR-guided renal artery angioplasty and stenting with sufficient visibility, good steerability, pushability, and device support.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Kos S,Huegli R,Hofmann E,Quick HH,Kuehl H,Aker S,Kaiser GM,Borm PJ,Jacob AL,Bilecen Ddoi
10.1097/RLI.0b013e31819b00f1subject
Has Abstractpub_date
2009-04-01 00:00:00pages
234-41issue
4eissn
0020-9996issn
1536-0210journal_volume
44pub_type
杂志文章abstract::Screening chronic hemodialysis patients (CHD) for acquired cystic disease of the kidneys (ACDK) and its complications (hemorrhage and neoplasm) has become accepted management. We evaluated patients on CHD as well as patients on chronic peritoneal dialysis (CPD) for ACDK. The kidneys of 80 chronic dialysis patients wer...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1987-09-01 00:00:00
abstract:OBJECTIVES:Comparison of intravenous Fenestra VC-enhanced computed tomography (CT) with gadopentetate dimeglumine and Ferucarbotran contrast-enhanced magnetic resonance imaging (MRI) for the in vivo imaging of hepatic ischemia/reperfusion injury (IRI) in a murine model. MATERIAL AND METHODS:After induction of hepatic ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318155aa2e
更新日期:2008-02-01 00:00:00
abstract:OBJECTIVES:X-ray computed tomography (CT) using phase contrast can provide images with greatly enhanced soft-tissue contrast in comparison to conventional attenuation-based CT. We report on the first scan of a human specimen recorded with a phase-contrast CT system based on an x-ray grating interferometer and a convent...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181e21866
更新日期:2010-07-01 00:00:00
abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199009000-00010
更新日期:1990-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors used gadolinium (Gd) chelate as a T1, T2, and T2* enhancing agent in reperfused myocardial infarction to compare the appearance of reperfused myocardial infarction on spin echo and gradient echo magnetic resonance (MR) sequences. METHODS:Rats (n = 28) were subjected to reperfused m...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199807000-00002
更新日期:1998-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the role of granulocytes in reperfusion injury after liver transplantation. The authors injected radiolabeled granulocytes to determine if human liver graft outcome could be correlated with granulocyte accumulation. MATERIALS AND METHODS:Pure granulocyte suspension was prepared fro...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199603000-00003
更新日期:1996-03-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to analyze the effect of dual-energy computed tomography (DECT) scanners and fluid characteristics on iodine quantification and to calculate the measurement variability range induced by those variables. METHODS:We performed an experimental phantom study with 4 mediastinal iodine ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000446
更新日期:2018-06-01 00:00:00
abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197807000-00002
更新日期:1978-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000133816.83192.38
更新日期:2004-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Measurements of segmental contraction of the left ventricle by standard magnetic resonance imaging (MRI) and two-dimensional echocardiography involve the comparison of diastolic and systolic time frames acquired from the same imaging plane in space. As the cone-shaped left ventricle shortens al...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199209000-00004
更新日期:1992-09-01 00:00:00
abstract::There are a number of sonographic findings seen in fibroadenoma of the breast. In a retrospective study, we examined the biopsy results of 59 masses given the sonographic diagnosis of fibroadenoma. We also reviewed the sonograms of an additional 26 biopsy-proven fibroadenomas that were not diagnosed as such with ultra...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198601000-00006
更新日期:1986-01-01 00:00:00
abstract:OBJECTIVES:To determine the impact of slice thickness on semiautomatic lymph node analysis. MATERIALS AND METHODS:Thoracic multislice computed tomography (MSCT) of 46 patients with NSCLC were reconstructed at 1.0-, 3.0-, and 5.0-mm slice thickness. Two radiologists independently determined long and short axis diameter...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181c443e1
更新日期:2010-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To develop a new automated calibration method for vessel measurements in vascular x-ray images. METHODS:Radiopaque marker bands mounted equidistantly on a small catheter were acquired in vitro at five image intensifier (II) sizes in x-ray projection images. The positions of the marker centers ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200004000-00002
更新日期:2000-04-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to evaluate the effect of structured reports (SRs) in comparison to nonstructured, free-text (FT) rectal magnetic resonance imaging (MRI) reports in patients with histologically proven rectal cancer and potential effects of both types of reporting on referring surgeons' satisfaction...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000336
更新日期:2017-04-01 00:00:00
abstract::Because of the strong scientific evidence in support of radiation hormesis, we can no longer ignore this concept. There is, however, need for additional, carefully documented investigations in selected biological systems exposed to LLIR if the matter of radiation hormesis is to be settled once and for all. This need s...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:
更新日期:1993-05-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to evaluate the feasibility of a computed tomography (CT) protocol enabling the visualization of the prostatic artery (PA) before prostatic artery embolization (PAE) in benign prostatic hyperplasia, which provides quantitative perfusion information of the prostate gland. MATERIALS ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000582
更新日期:2019-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To test noninvasive inductive heating of implanted vascular stents as an alternative approach for reduction or prevention of neointimal hyperplasia. METHODS:Calorimetric pretests were performed to get an orientation on the different parameters of influence for inductive heating of stents. The ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000117881.42422.72
更新日期:2004-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate different vein graft-coated stent systems in the endovascular treatment of experimental arteriovenous fistulae (AVF) in a canine model. METHODS:Bilateral carotid-to-external jugular vein AVF were created. Two balloon-expandable tantalum stents (Strecker stent), two self-expanding n...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199901000-00004
更新日期:1999-01-01 00:00:00
abstract:OBJECTIVE:The objective of this study was to evaluate the diagnostic performance and safety of magnetic resonance (MR) imaging-guided percutaneous mediastinal biopsy procedures using a 0.23-T open MR system with optical tracking navigation. MATERIALS AND METHODS:A retrospective analysis of 59 participants (38 males an...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/RLI.0b013e31827a4a17
更新日期:2013-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Air microemboli may damage the cerebral microvasculature. The aim of this study was to evaluate the safety of ultrasound contrast agents composed of air microspheres with regard to cerebral damage when administered into the arterial system (ie, when not filtered by the capillary system of the l...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199803000-00001
更新日期:1998-03-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. MATERIALS AND METHODS:Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000004
更新日期:2014-05-01 00:00:00
abstract::The morphologic changes in healthy rat kidneys (n = 102) were studied 2 or 48 hours after intravenous injection of 1 or 3 g iodine (I)/kg of high-osmolality diatrizoate, low-osmolality iopromide and iohexol, or iso-osmolality iotrolan, as well as after 0.2 or 0.6 g/kg of the high-osmolality magnetic resonance contrast...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199110000-00009
更新日期:1991-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To study cellular mechanisms that cause contrast media nephropathy, an in vitro system for proximal and distal tubular cells has been established to evaluate the influence of x-ray contrast media on tubular function. METHODS:Confluent cell cultures of the two renal cell lines, proximal tubule ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199411000-00002
更新日期:1994-11-01 00:00:00
abstract::An isotopic radiation source 125I was investigated for use in soft tissue radiaography, with particular attention to possible use in mammography for mass screening. Film sensitivities, exposure rates, absorbed doeses, contrast and resolution were determined, and compared to conventional x-ray units. It was found that ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197509000-00007
更新日期:1975-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The object of this study was to determine by flow cytometry the cellular and DNA content of the washings of core biopsy samples and needles obtained during stereotactic core biopsies of clinically occult suspicious lesions. METHODS:Fourteen-gauge core multipass biopsy inner-needle saline washi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199801000-00008
更新日期:1998-01-01 00:00:00
abstract:OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318190fbd2
更新日期:2009-02-01 00:00:00
abstract::Early detection of pancreatic ductal adenocarcinoma (PDAC) represents the most significant step toward the treatment of this aggressive lethal disease. Previously, we engineered a preclinical Thy1-targeted microbubble (MBThy1) contrast agent that specifically recognizes Thy1 antigen overexpressed in the vasculature of...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000697
更新日期:2020-11-01 00:00:00
abstract::Using simple surgical techniques, experimental carotid aneurysms are created which simulate some types of human berry aneurysms, both in hemodynamic and radiographic behavior. End to side anastomoses of an external jugular vein graft to the common carotid artery can be carried out by radiologic personnel with no forma...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197703000-00009
更新日期:1977-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors determine the value of contrast-enhanced, three-dimensional (3D) magnetic resonance angiography (MRA) in the assessment of the renal arteries in comparison with conventional arteriography (CA). METHODS:One hundred three patients (71 m, 32 f) were evaluated with both CA and 3D MRA. ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199809000-00021
更新日期:1998-09-01 00:00:00
abstract::Sixteen observers averaging 7.4 years experience in interpreting radiology images and 16 observers without radiology training were tested for their ability to detect low-contrast signals in structured noise backgrounds using a digital display system. No significant difference in true positives, false positives, time t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198704000-00006
更新日期:1987-04-01 00:00:00