Evaluation of the prostate imaging reporting and data system for the detection of prostate cancer by the results of targeted biopsy of the prostate.

Abstract:

PURPOSE:The purpose of this study was to evaluate the magnetic resonance prostate imaging reporting and data system (PI-RADS) for the detection of prostate cancer by the results of magnetic resonance imaging (MRI)-guided biopsy of the prostate as a reference standard. PATIENTS AND METHODS:In 55 patients who had undergone MRI-guided biopsy of the prostate, we retrospectively matched every biopsy core with the corresponding lesion in previously acquired endorectal multiparametric MRI including T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI), and dynamic contrast-enhanced MRI (DCE-MRI) at 1.5 T. Two readers blinded to the results of the biopsy evaluated each biopsied lesion according to the PI-RADS scoring system. The results of the targeted biopsy were used as a reference standard. Receiver operating characteristic analysis was performed for statistical analysis. RESULTS:A total of 113 lesions in the 55 patients were evaluated; 30 lesions were malignant. When evaluated according to the criteria of the PI-RADS scoring system, DCE-MRI revealed a lower area under the receiver operating characteristic curve (AUC) (0.76) compared with T2WI (0.88; P=0.06) and DWI (0.93; P=0.004). A sum score combining T2WI, DWI, and DCE-MRI yielded an AUC of 0.93, whereas a sum score combining only T2WI and DWI yielded an AUC of 0.95. In central gland lesions, T2WI showed a numerically higher AUC compared with DWI (0.98 and 0.95), whereas, in peripheral zone lesions, DWI was superior (AUC of 0.93 and 0.73; P=0.04). An approach assigning a PI-RADS score for T2WI to central gland lesions and for DWI to peripheral zone lesions yielded an AUC of 0.96 and was numerically superior compared with any sequence alone and sum scores combining T2WI and DWI as well as T2WI, DWI, and DCE-MRI. CONCLUSIONS:The PI-RADS scoring system shows a good diagnostic performance for the detection of prostate cancer when using a sum score. However, DCE-MRI does not seem to add significant value when evaluated according to the recommended criteria. Assigning a score for T2WI to central gland lesions and for DWI to peripheral zone lesions might be sufficient for stratification of patients for further diagnostic workup.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Baur AD,Maxeiner A,Franiel T,Kilic E,Huppertz A,Schwenke C,Hamm B,Durmus T

doi

10.1097/RLI.0000000000000030

subject

Has Abstract

pub_date

2014-06-01 00:00:00

pages

411-20

issue

6

eissn

0020-9996

issn

1536-0210

journal_volume

49

pub_type

杂志文章
  • Effects of iodinated x-ray contrast media on renal epithelial cells in culture.

    abstract:RATIONALE AND OBJECTIVES:To study cellular mechanisms that cause contrast media nephropathy, an in vitro system for proximal and distal tubular cells has been established to evaluate the influence of x-ray contrast media on tubular function. METHODS:Confluent cell cultures of the two renal cell lines, proximal tubule ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199411000-00002

    authors: Andersen KJ,Christensen EI,Vik H

    更新日期:1994-11-01 00:00:00

  • Constructing pre- and post-tests in a medical student elective.

    abstract::The importance of evaluating medical student performance has been widely addressed in the medical education literature. Multiple-choice examinations are the preferred method of testing because they are easy to administer and score. Development of parallel or equivalent pre- and post-examinations provides objective inf...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Blane CE,Calhoun JG,Vydareny KH

    更新日期:1986-09-01 00:00:00

  • Magnetic resonance microscopy of the rat carotid artery at 300 megahertz.

    abstract:RATIONALE AND OBJECTIVES:Magnetic resonance microscopy (MRM) has evolved from a technical curiosity to a tool with which researchers can study important disease models. But MRM is not simply an extension of clinical magnetic resonance imaging. In this article, the unique adaptations of MRM required in the study of caro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199409000-00004

    authors: Arnder L,Zhou X,Cofer GP,Hedlund LW,Johnson GA

    更新日期:1994-09-01 00:00:00

  • Contrast media for CT. An analysis of the early pharmacokinetics.

    abstract::Iohexol and meglumine-sodium diatrizoate were injected intravenously into 18 pigs as either a 99:1 or 1:99 mixture. Blood samples were taken for 30 minutes and the concentration of each of the two contrast media was measured by means of a double labeling technique with 125I and 131I. Relative concentrations of iohexol...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198511000-00016

    authors: Jensen LI,Dean PB,Nyman U,Golman K

    更新日期:1985-11-01 00:00:00

  • Hepatic parenchymal changes after the intraarterial injection of lipiodol in tumor-bearing rabbits.

    abstract:RATIONALE AND OBJECTIVES:The influence of lipiodol injection on hepatic morphology and function was investigated in 119 rabbits with hepatic VX2 tumors. METHODS:The rabbits were divided into the following three groups, according to the materials injected via the proper hepatic artery: group 1 received doxorubicin (Adr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199302000-00009

    authors: Akashi Y,Koreeda C,Mizuno T,Inoue K,Kawa SK,Tanaka Y

    更新日期:1993-02-01 00:00:00

  • Validation of ultrafast computed tomographic left ventricular volume measurement.

    abstract::Left ventricular volume has been measured with ultrafast computed tomography. However, the accuracy with which this can be done is unknown. We therefore imaged with ultrafast computed tomography 11 rectangular phantoms, 20 to 225 ml, and 17 left ventricular casts, 15 to 112 ml. Two observers planimetered serial tomogr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199101000-00006

    authors: Pietras RJ,Wolfkiel CJ,Veselik K,Roig E,Chomka EV,Brundage BH

    更新日期:1991-01-01 00:00:00

  • Comparative transmetallation kinetics and thermodynamic stability of gadolinium-DTPA bis-glucosamide and other magnetic resonance imaging contrast media.

    abstract:RATIONALE AND OBJECTIVES:The relative stability and selectivity of magnetic resonance (MR) imaging contrast agents were compared with in vitro transmetallation and ligand competition reactions. MATERIALS AND METHODS:A gadolinium (Gd)-DTPA-BIGA, Gd-DTPA-BMA, Gd-DTPA, or Gd-HP-DO3A solution was mixed with an equimolar s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199610000-00003

    authors: Puttagunta NR,Gibby WA,Puttagunta VL

    更新日期:1996-10-01 00:00:00

  • Development, chemistry, and physical properties of iopamidol and its analogues.

    abstract::A series of 5-hydroxyacylamino-2,4,6-triiodo-N,N'-hydroxy-alkyl-isophtalamides was prepared in order to study the structural requirements for high water solubility and low toxicity. Among the amides substituted by 2-hydroxyethyl; 2,3-dihydroxypropyl; 1,3-dihydroxypropyl-; and 1,1-dihydroxy-methyl-2-oxyethyl- groups, t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00065

    authors: Pitrè D,Felder E

    更新日期:1980-11-01 00:00:00

  • Ultrasound analysis of tongue, hyoid, and larynx activity during swallowing.

    abstract::Using real-time ultrasound, the motions of the tongue, hyoid bone, and larynx were monitored and timed during swallowing in ten normal subjects. A well-defined propulsive wave of the tongue was observed during swallowing a 5-cc water bolus. The body of the hyoid bone was identified on the ultrasound scan as a high ech...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198403000-00003

    authors: Shawker TH,Sonies B,Hall TE,Baum BF

    更新日期:1984-03-01 00:00:00

  • Critical Questions Regarding Gadolinium Deposition in the Brain and Body After Injections of the Gadolinium-Based Contrast Agents, Safety, and Clinical Recommendations in Consideration of the EMA's Pharmacovigilance and Risk Assessment Committee Recommend

    abstract::For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000374

    authors: Runge VM

    更新日期:2017-06-01 00:00:00

  • Safety and efficacy of dotarem (Gd-DOTA) versus magnevist (Gd-DTPA) in magnetic resonance imaging of the central nervous system.

    abstract:RATIONALE AND OBJECTIVES:Gd-DTPA is a well-characterized, safe contrast agent frequently used in magnetic resonance imaging (MRI) of the central nervous system. The purpose of this double-blind, comparative MRI study of brain, spine, trunk, and limbs was to evaluate the safety and efficacy of Gd-DOTA versus Gd-DTPA in ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-199502000-00002

    authors: Oudkerk M,Sijens PE,Van Beek EJ,Kuijpers TJ

    更新日期:1995-02-01 00:00:00

  • Mixing problems of low flow hepatic artery infusion. Improvement with small caliber double lumen balloon catheters.

    abstract::The problem of inhomogeneous mixing encountered during hepatic artery (HA) chemotherapy infusion was assessed and a practical solution examined. A glass model of the human HA distribution was used to determine mixing homogeneity of low flow (1.4 mL/minute) dye infusion into pulsatile flow (280-300 mL/minute) of a flui...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198807000-00007

    authors: Barth KH,Lutz RJ,Kremers PW,Miller DL

    更新日期:1988-07-01 00:00:00

  • Technical feasibility and performance studies of a 0.009-inch nitinol microguidewire for potential neuroendovascular applications.

    abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199704000-00008

    authors: Putman CM,Chaloupka JC,Kailasnath P,Alderman J

    更新日期:1997-04-01 00:00:00

  • Developments in X-Ray Contrast Media and the Potential Impact on Computed Tomography.

    abstract::Over the past 120 years, continuous developments in medical imaging has improved diagnosis and treatment for many diseases and has thereby improved treatment outcome and quality of life of many patients. The number of computed tomography (CT) examinations is today increasing by 4% per year worldwide, for a total of ap...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000696

    authors: Schöckel L,Jost G,Seidensticker P,Lengsfeld P,Palkowitsch P,Pietsch H

    更新日期:2020-09-01 00:00:00

  • Nephrogenic systemic fibrosis in patients with chronic kidney disease who received gadopentetate dimeglumine.

    abstract:OBJECTIVE:To determine the prevalence of nephrogenic systemic fibrosis (NSF) in patients with chronic kidney disease (CKD) who have received gadopentetate dimeglumine. MATERIALS AND METHODS:We retrospectively studied all patients who underwent contrast-enhanced magnetic resonance imagings (CE-MRIs) between January 1, ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31819343ba

    authors: Hope TA,Herfkens RJ,Denianke KS,LeBoit PE,Hung YY,Weil E

    更新日期:2009-03-01 00:00:00

  • Preliminary evaluation of Hexabrix for temporomandibular joint arthrography.

    abstract::A double-blind randomized study of ten patients compared Hexabrix 32% to Renografin-60 in TMJ arthrography. Equivalent volumes of contrast material were injected under fluoroscopic observation, with film quality and patient subjective response graded independently by three radiologists. In immediate arthrogram quality...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00032

    authors: Katzberg RW

    更新日期:1984-11-01 00:00:00

  • Estimating digital information throughput rates for radiology networks. A model.

    abstract::The design and implementation of a digital radiology image management system requires the definition, evaluation, and comparison of appropriate measures of system performance. The mean throughput rate is an important measure of the actual performance of a finished system. The mean throughput rate identifies the transm...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00014

    authors: Cox GG,Templeton AW,Anderson WH,Cook LT,Hensley KS,Dwyer SJ 3rd

    更新日期:1986-02-01 00:00:00

  • Comparison of 1.5 and 3 T BOLD MR to study oxygenation of kidney cortex and medulla in human renovascular disease.

    abstract:OBJECTIVES:Imaging of the kidney using blood oxygen level dependent MR presents a major opportunity to examine differences in tissue oxygenation within the cortex and medulla applicable to human disease. We sought to define the differences between regions within kidneys and to optimize selection of regions of interest ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b4c1e8

    authors: Gloviczki ML,Glockner J,Gomez SI,Romero JC,Lerman LO,McKusick M,Textor SC

    更新日期:2009-09-01 00:00:00

  • Accuracy of ultrasound in fetal femur length determination. Ultrasound phantom study.

    abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00016

    authors: Gamba JL,Bowie JD,Dodson WC,Hedlund LW

    更新日期:1985-05-01 00:00:00

  • Application of a Novel Iterative Denoising and Image Enhancement Technique in T1-Weighted Precontrast and Postcontrast Gradient Echo Imaging of the Abdomen: Improvement of Image Quality and Diagnostic Confidence.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact of a novel iterative denoising and image enhancement technique in T1-weighted precontrast and postcontrast volume-interpolated breath-hold examination (VIBE) of the abdomen on image quality, noise levels, and diagnostic confidence without change of acquisit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000746

    authors: Gassenmaier S,Afat S,Nickel D,Kannengiesser S,Herrmann J,Hoffmann R,Othman AE

    更新日期:2020-11-18 00:00:00

  • Tamm-Horsfall glycoprotein excretion and aggregation during intravenous urography. Relevance to acute renal failure.

    abstract::The effect of intravenous urography (IVU) on the excretion rate and precipitation of Tamm-Horsfall glycoprotein (THG) has been evaluated in 19 patients. Urine samples were collected immediately before the administration of contrast medium (U1) and then during the period of the excretion urogram (U2). The urinary THG: ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198501000-00014

    authors: Dawnay AB,Thornley C,Nockler I,Webb JA,Cattell WR

    更新日期:1985-01-01 00:00:00

  • A large animal model (swine) to study the diagnosis and treatment of cholelithiasis.

    abstract::Human gallstones were surgically placed into the gallbladders of 200 swine. Eight of these swine were used as a prospective series to verify that the placement and presence of human gallstones in their gallbladders caused no significant pathologic changes in the gallbladder and that the gallstones were not spontaneous...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198902000-00005

    authors: Griffith SL,Burney BT,Fry FJ,Franklin TD Jr

    更新日期:1989-02-01 00:00:00

  • Effects of dilating the canine pulmonary annulus with two balloons. Doppler ultrasound and postmortem findings.

    abstract::Simultaneous inflation of two balloons may be necessary for balloon dilation valvuloplasty in patients with a large annulus. We examined the cardiovascular effects of dilating the pulmonary annulus with two balloons in 18 normal dogs using pulsed Doppler ultrasound and gross and microscopic examination. When the ratio...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198808000-00005

    authors: Butto F,Burke B,Berry JM,Amplatz K,Bass JL

    更新日期:1988-08-01 00:00:00

  • Semiquantitative assessment of myocardial perfusion using magnetic resonance imaging: evaluation of appropriate thresholds and segmentation models.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000133816.83192.38

    authors: Fenchel M,Kramer U,Helber U,Stauder NI,Franow A,Claussen CD,Miller S

    更新日期:2004-09-01 00:00:00

  • Acute systemic and renal hemodynamic effects of meglumine/sodium diatrizoate 76% and iopamidol in euvolemic and dehydrated dogs.

    abstract::We examined the acute systemic and renal hemodynamic effects of intravenous meglumine/sodium diatrizoate-76% and iopamidol in euvolemic and dehydrated dogs. The physiologic responses were compared with acute changes in the level of an endogenous heparin-like material (EHM). One of eight dehydrated dogs receiving diatr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198610000-00005

    authors: Katzberg RW,Morris TW,Lasser EC,DiMarco PL,Merguerian PA,Ventura JA,Pabico RC,McKenna BA

    更新日期:1986-10-01 00:00:00

  • Trabecular bone structure of the distal radius, the calcaneus, and the spine: which site predicts fracture status of the spine best?

    abstract:RATIONALE AND OBJECTIVES:To compare trabecular bone structure measures obtained in magnetic resonance images of the distal radius and the calcaneus as well as computed tomographic images of the spine versus bone mineral density (BMD) of the spine and the calcaneus in the prediction of osteoporotic spine fracture status...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000129154.50654.4e

    authors: Link TM,Bauer J,Kollstedt A,Stumpf I,Hudelmaier M,Settles M,Majumdar S,Lochmüller EM,Eckstein F

    更新日期:2004-08-01 00:00:00

  • Image Quality and Geometric Distortion of Modern Diffusion-Weighted Imaging Sequences in Magnetic Resonance Imaging of the Prostate.

    abstract:PURPOSE:The aim of this study was to compare qualitative and quantitative image quality and geometric distortion of 4 magnetic resonance diffusion-weighted imaging (DWI) sequences of the prostate using comparable imaging parameters and similar acquisition times. METHODS AND MATERIALS:Axial T2-weighted turbo spin echo ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000429

    authors: Stocker D,Manoliu A,Becker AS,Barth BK,Nanz D,Klarhöfer M,Donati OF

    更新日期:2018-04-01 00:00:00

  • Searching for lung nodules. Visual dwell indicates locations of false-positive and false-negative decisions.

    abstract::Eye position recordings made while radiologists searched chest images for lung nodules showed that regions falsely reported positive or suspicious received prolonged visual attention. Correlation of regional fixation dwell time with independent ratings of image features indicated that more than 90% of false-positive d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kundel HL,Nodine CF,Krupinski EA

    更新日期:1989-06-01 00:00:00

  • Polycystic kidney disease evaluation by magnetic resonance imaging in ischemia-reperfusion injured PKD1 knockout mouse model: comparison of T2-weighted FSE and true-FISP.

    abstract:OBJECTIVE:To investigate the efficacy of true fast imaging with steady state precession (true-FISP) compared with T2-weighted fast spin echo (T2W-FSE) in monitoring changes in cyst volume and renal expansion in an ischemia reperfusion (IR) injured PKD1 knockout (IKO) mouse model. MATERIALS AND METHODS:The animal study...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181be3501

    authors: Zhou X,Bao H,Takakura A,Zhou J,Albert M,Sun Y

    更新日期:2010-01-01 00:00:00

  • Incidence of nephrogenic systemic fibrosis in patients undergoing dialysis after contrast-enhanced magnetic resonance imaging with gadolinium-based contrast agents: the Prospective Fibrose Nephrogénique Systémique study.

    abstract:BACKGROUND:Nephrogenic systemic fibrosis (NSF) has been related to the use of gadolinium-based contrast agents (GBCAs) in patients undergoing dialysis. The Prospective Fibrose Nephrogénique Systémique study, a French prospective study supported by the French drug regulatory agency (Agence Nationale de Sécurité du Médic...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0000000000000000

    authors: Amet S,Launay-Vacher V,Clément O,Frances C,Tricotel A,Stengel B,Gauvrit JY,Grenier N,Reinhardt G,Janus N,Choukroun G,Laville M,Deray G

    更新日期:2014-02-01 00:00:00