Abstract:
OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field digital baseline mammograms (craniocaudal and mediolateral), were included in this prospective trial. For the postinterventional digital mammograms, the milliampere seconds were reduced either by 50% or by 75%. Dose-reduced images were evaluated for sufficient image quality to verify the position of the marker. RESULTS:In 193 of 200 cases (96.5%), image quality was sufficient to verify the correct position of the marker. One (1%) case with insufficient image quality occurred in the 50% dose-reduction group and 6 (6%) in the 75% dose-reduction group (P = 0.06). CONCLUSION:Our results indicate that under evaluation of each individual case, a dose reduction of 50% to 75% can be recommended in postinterventional digital mammograms.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Riedl CC,Jaromi S,Floery D,Pfarl G,Fuchsjaeger MH,Helbich THdoi
10.1097/01.rli.0000163743.63063.9fkeywords:
subject
Has Abstractpub_date
2005-06-01 00:00:00pages
343-8issue
6eissn
0020-9996issn
1536-0210pii
00004424-200506000-00004journal_volume
40pub_type
杂志文章abstract:OBJECTIVES:The objective of this study was to assess the feasibility of the combination of magnetic resonance (MR)-guided biopsy (MRGB) and diagnostic 3T MR imaging in the localization of local recurrence of prostate cancer (PCa) after external beam radiation therapy (EBRT). MATERIALS AND METHODS:Twenty-four consecuti...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181c7bcda
更新日期:2010-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The clinically most widely used devices (Porstmann-plug, Rashkind-umbrella, Botallooccluder) have inherent specific limitations (eg, transarterial approach, residual shunts, limited retrieval). The authors assess practicability, efficacy, and tissue reaction of the new retrievable transvenous p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199709000-00004
更新日期:1997-09-01 00:00:00
abstract::Pyrroxamide [N-(1-hydroxymethyl-2,3-dihydroxypropyl)-2,2,5,5-tetramethyl pyrrolidine-1-oxyl-3-carboxyamide] is a newly tested nonionic monomeric nitroxyl compound with demonstrated effectiveness for MRI contrast enhancement at doses as low as 10(-3) M. Pyrroxamide and its hydroxylamine metabolic derivative were tested...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198808000-00013
更新日期:1988-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:It is widely believed that down-sizing catheters, and possibly needles, will decrease damage to the entry vessel in the performance of angiography. The purposes of this in vitro experiment are to determine if smaller needles produce less arterial wall damage than larger needles and to assess th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199210000-00001
更新日期:1992-10-01 00:00:00
abstract::An isotopic radiation source 125I was investigated for use in soft tissue radiaography, with particular attention to possible use in mammography for mass screening. Film sensitivities, exposure rates, absorbed doeses, contrast and resolution were determined, and compared to conventional x-ray units. It was found that ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197509000-00007
更新日期:1975-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the short-term effects of a new nitinol stent on canine arteries. METHODS:Eighteen nitinol mesh stents were placed in abdominal aortas, common iliac arteries, and renal arteries of six dogs. Angiography was performed to evaluate the patency rates and structural changes of arteries ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199905000-00007
更新日期:1999-05-01 00:00:00
abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199107000-00003
更新日期:1991-07-01 00:00:00
abstract::A patient, suffering a severe anaphylactoid reaction to contrast material injected for an intravenous pyelogram, developed a consumption coagulopathy and evidence of complement activation. Precontrast complement values suggested that the patient had been processing complement via the classical pathway, perhaps as a co...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198011001-00004
更新日期:1980-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors investigate whether a modified gadolinium (Gd)-DTPA formulation can be aerosolized and used as a contrast agent for magnetic resonance (MR) ventilation imaging of the lungs. METHODS:Gadolinium-DTPA (gadopentetate dimeglumine, Schering AG, Berlin, Germany, 100 mmol Gd/L) was modifie...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199712000-00010
更新日期:1997-12-01 00:00:00
abstract::Iohexol and meglumine-sodium diatrizoate were injected intravenously into 18 pigs as either a 99:1 or 1:99 mixture. Blood samples were taken for 30 minutes and the concentration of each of the two contrast media was measured by means of a double labeling technique with 125I and 131I. Relative concentrations of iohexol...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198511000-00016
更新日期:1985-11-01 00:00:00
abstract:OBJECTIVE:To evaluate the degree of ischemic changes of the small intestine after arterial embolization of proximal or distal arteries with Gelfoam particles and coils in dogs. METHODS:Superselective arterial embolization in 18 dogs was performed using a coaxial catheter system. Gelfoam occlusion of the proximal level...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199910000-00004
更新日期:1999-10-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to achieve initial experience with non-contrast-enhanced (ne) magnetic resonance angiography (MRA) of the lower leg arteries in patients with peripheral arterial occlusive disease (PAOD) at 7 T. MATERIALS AND METHODS:Seven patients with PAOD were examined on a 7-T whole-body magnet...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000044
更新日期:2014-05-01 00:00:00
abstract::Patients with intracranial arteriovenous malformations (AVM) can expect significant mortality (15% to 20%) and morbidity (20% to 30%) over a 15-year to 20-year period. Recent advances in interventional neuroradiology, neurosurgery, neuroanesthesia, and stereotactic radiotherapy provide the opportunity to obliterate ma...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199008000-00014
更新日期:1990-08-01 00:00:00
abstract::We examined the acute systemic and renal hemodynamic effects of intravenous meglumine/sodium diatrizoate-76% and iopamidol in euvolemic and dehydrated dogs. The physiologic responses were compared with acute changes in the level of an endogenous heparin-like material (EHM). One of eight dehydrated dogs receiving diatr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198610000-00005
更新日期:1986-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To develop a new automated calibration method for vessel measurements in vascular x-ray images. METHODS:Radiopaque marker bands mounted equidistantly on a small catheter were acquired in vitro at five image intensifier (II) sizes in x-ray projection images. The positions of the marker centers ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200004000-00002
更新日期:2000-04-01 00:00:00
abstract::We present a new method for evaluating in vivo changes in bone mineralization in the peripheral skeleton, using computed tomography (CT). A set of bone mineralization indices are generated from numerous CT images of the patient's distal radius. The cross-sectional anatomy displayed by the CT scan allows for separate e...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197903000-00003
更新日期:1979-03-01 00:00:00
abstract::A feasibility study is described to provide quantitative texture measures to distinguish between normal lung, alveolar infiltrates and interstitial infiltrates. Advanced computer imaging technology and decision making processes were applied to distinguish between these textural patterns. The results, based on computer...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197807000-00005
更新日期:1978-07-01 00:00:00
abstract::Skeletal abnormalities have been reported on numerous occasions in patients who have received high doses of vitamin A and its derivatives. Recently, a new derivative, isotretinoin (Accutane, Hoffman-LaRoche, Inc.), has become available for the treatment of cystic acne. Ninety-six patients treated for a minimum of four...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198601000-00007
更新日期:1986-01-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,多中心研究,随机对照试验
doi:10.1097/RLI.0000000000000121
更新日期:2015-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of a new device for interventional creation of atrial septal defects (ASD) working with high-frequency alternating current in an in vitro study with porcine atria. METHODS:The device consists of a symmetrical cage of six superelastic monofile wires, including a mic...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199702000-00003
更新日期:1997-02-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of kidney stone composition analysis using spectral detector computed tomography scanner (SDCT) with normal- and low-dose imaging protocols. METHODS:A total of 154 stones harvested from nephrolithotripsy or nephrolithotomy with a known monocrystalline...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000468
更新日期:2018-08-01 00:00:00
abstract::Using a 1.5 T magnetic resonance imaging (MRI) system, cine phase-contrast and magnitude images were obtained in three phantoms that simulated different anatomic configurations of aortic dissection. The dissection phantoms were made of compliant materials, and pulsatile flow was used in all experiments. Phantoms diffe...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199112000-00007
更新日期:1991-12-01 00:00:00
abstract::The large intestines of eight boxer dogs with canine histiocytic ulcerative colitis (CHUC) and 10 normal dogs were studied by in vivo angiography and postmortem microangiography. The vascular abnormalities were correlated with the gross and histologic pathology found at necropsy. The angiographic abnormalities were ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197505000-00005
更新日期:1975-05-01 00:00:00
abstract::An agent has been identified in lymph from rat kidneys rendered ischemic by partial renal artery occlusion that induces a striking neovascular response in a hamster cheek-pouch assay system. The factor has a high molecular weight, cannot be identified in lymph from normal kidneys, and is associated with a marked incre...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198501000-00015
更新日期:1985-01-01 00:00:00
abstract::The retropsoas recess, a previously undescribed normal anatomic variant, is reported. In most individuals, the space posterior to the belly of the psoas muscle contains fat within the posterior pararenal space. However, a retrospective review of 250 consecutive CT examinations of the abdomen revealed 11 cases (4.4%) i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198707000-00004
更新日期:1987-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. MATERIALS AND METHODS:The nephrotoxic potential of intravenously injected contrast agents in Beagl...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000087096.61127.13
更新日期:2003-11-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to assess the diagnostic value and safety of the contrast agent gadoterate meglumine (Gd-DOTA, DOTAREM, Guerbet, Roissy CdG Cedex, France) in the setting of a postmarketing surveillance study. MATERIALS AND METHODS:Between January 2004 and October 2005, radiologists in 61 radiol...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000248893.01067.e5
更新日期:2007-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Studies describing the effects of radiographic contrast media (RCM) in leukocyte chemotaxis have been contradictory. No studies have been performed after in-vivo exposure. The authors assess the effect of RCM on leukocytes following in-vivo exposure. METHODS:Seventeen patients were studied aft...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199401000-00012
更新日期:1994-01-01 00:00:00
abstract:OBJECTIVE:To investigate the efficacy of true fast imaging with steady state precession (true-FISP) compared with T2-weighted fast spin echo (T2W-FSE) in monitoring changes in cyst volume and renal expansion in an ischemia reperfusion (IR) injured PKD1 knockout (IKO) mouse model. MATERIALS AND METHODS:The animal study...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181be3501
更新日期:2010-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVE:The authors performed a retrospective study in ultrasound to investigate new aspects in the sonomorphology of lymph node metastases of the neck. In this study, it could be demonstrated the first time that the histologic characteristics of the metastases determine the sonographic appearance. In a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199609000-00001
更新日期:1996-09-01 00:00:00