Potential of dose reduction after marker placement with full-field digital mammography.

Abstract:

OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field digital baseline mammograms (craniocaudal and mediolateral), were included in this prospective trial. For the postinterventional digital mammograms, the milliampere seconds were reduced either by 50% or by 75%. Dose-reduced images were evaluated for sufficient image quality to verify the position of the marker. RESULTS:In 193 of 200 cases (96.5%), image quality was sufficient to verify the correct position of the marker. One (1%) case with insufficient image quality occurred in the 50% dose-reduction group and 6 (6%) in the 75% dose-reduction group (P = 0.06). CONCLUSION:Our results indicate that under evaluation of each individual case, a dose reduction of 50% to 75% can be recommended in postinterventional digital mammograms.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Riedl CC,Jaromi S,Floery D,Pfarl G,Fuchsjaeger MH,Helbich TH

doi

10.1097/01.rli.0000163743.63063.9f

keywords:

subject

Has Abstract

pub_date

2005-06-01 00:00:00

pages

343-8

issue

6

eissn

0020-9996

issn

1536-0210

pii

00004424-200506000-00004

journal_volume

40

pub_type

杂志文章
  • Feasibility of 3T dynamic contrast-enhanced magnetic resonance-guided biopsy in localizing local recurrence of prostate cancer after external beam radiation therapy.

    abstract:OBJECTIVES:The objective of this study was to assess the feasibility of the combination of magnetic resonance (MR)-guided biopsy (MRGB) and diagnostic 3T MR imaging in the localization of local recurrence of prostate cancer (PCa) after external beam radiation therapy (EBRT). MATERIALS AND METHODS:Twenty-four consecuti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181c7bcda

    authors: Yakar D,Hambrock T,Huisman H,Hulsbergen-van de Kaa CA,van Lin E,Vergunst H,Hoeks CM,van Oort IM,Witjes JA,Barentsz JO,Fütterer JJ

    更新日期:2010-03-01 00:00:00

  • Retrievable patent ductus arteriosus plug for interventional, transvenous occlusion of the patent ductus arteriosus. Evaluation in lambs and preliminary clinical results.

    abstract:RATIONALE AND OBJECTIVES:The clinically most widely used devices (Porstmann-plug, Rashkind-umbrella, Botallooccluder) have inherent specific limitations (eg, transarterial approach, residual shunts, limited retrieval). The authors assess practicability, efficacy, and tissue reaction of the new retrievable transvenous p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199709000-00004

    authors: Grabitz RG,Schräder R,Sigler M,Seghaye MC,Dzionsko C,Handt S,Schneidt B,Von Bernuth G

    更新日期:1997-09-01 00:00:00

  • Pyrroxamide, a nonionic nitroxyl spin label contrast agent for magnetic resonance imaging. Mutagenesis and cell survival.

    abstract::Pyrroxamide [N-(1-hydroxymethyl-2,3-dihydroxypropyl)-2,2,5,5-tetramethyl pyrrolidine-1-oxyl-3-carboxyamide] is a newly tested nonionic monomeric nitroxyl compound with demonstrated effectiveness for MRI contrast enhancement at doses as low as 10(-3) M. Pyrroxamide and its hydroxylamine metabolic derivative were tested...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198808000-00013

    authors: Gordon DG,Brasch RC,Ogan MD,Deen D

    更新日期:1988-08-01 00:00:00

  • Effects of angiographic needle size and subsequent catheter insertion on arterial walls. An in vitro experiment in human cadavers.

    abstract:RATIONALE AND OBJECTIVES:It is widely believed that down-sizing catheters, and possibly needles, will decrease damage to the entry vessel in the performance of angiography. The purposes of this in vitro experiment are to determine if smaller needles produce less arterial wall damage than larger needles and to assess th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00001

    authors: Smith DC,Hamlin JA,Jensen DA,Pappas JM,Westengard JC,Saukel GW

    更新日期:1992-10-01 00:00:00

  • Investigation of 125I as an isotopic source for mammography.

    abstract::An isotopic radiation source 125I was investigated for use in soft tissue radiaography, with particular attention to possible use in mammography for mass screening. Film sensitivities, exposure rates, absorbed doeses, contrast and resolution were determined, and compared to conventional x-ray units. It was found that ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197509000-00007

    authors: Fairchild R,Atkins HL,Lebowitz E,Greenberg D

    更新日期:1975-09-01 00:00:00

  • Short-term effects of a new intravascular nitinol stent in canine arteries.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the short-term effects of a new nitinol stent on canine arteries. METHODS:Eighteen nitinol mesh stents were placed in abdominal aortas, common iliac arteries, and renal arteries of six dogs. Angiography was performed to evaluate the patency rates and structural changes of arteries ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199905000-00007

    authors: Lee KW,Park JH,Chung JW,Kim WS,Lee W,Yeon KM

    更新日期:1999-05-01 00:00:00

  • Time course of satisfaction of search.

    abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199107000-00003

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Rooholamini SA,Coffman CE,Cornell SH,Cragg AH,Galvin JR,Honda H,Kao SC

    更新日期:1991-07-01 00:00:00

  • Changes in complement and coagulation factors in a patient suffering a severe anaphylactoid reaction to injected contrast material: some considerations of pathogenesis.

    abstract::A patient, suffering a severe anaphylactoid reaction to contrast material injected for an intravenous pyelogram, developed a consumption coagulopathy and evidence of complement activation. Precontrast complement values suggested that the patient had been processing complement via the classical pathway, perhaps as a co...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00004

    authors: Lasser EC,Lang JH,Lyon SG,Hamblin AE

    更新日期:1980-11-01 00:00:00

  • Magnetic resonance imaging of pulmonary ventilation. Initial experiences with a gadolinium-DTPA-based aerosol.

    abstract:RATIONALE AND OBJECTIVES:The authors investigate whether a modified gadolinium (Gd)-DTPA formulation can be aerosolized and used as a contrast agent for magnetic resonance (MR) ventilation imaging of the lungs. METHODS:Gadolinium-DTPA (gadopentetate dimeglumine, Schering AG, Berlin, Germany, 100 mmol Gd/L) was modifie...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199712000-00010

    authors: Misselwitz B,Mühler A,Heinzelmann I,Böck JC,Weinmann HJ

    更新日期:1997-12-01 00:00:00

  • Contrast media for CT. An analysis of the early pharmacokinetics.

    abstract::Iohexol and meglumine-sodium diatrizoate were injected intravenously into 18 pigs as either a 99:1 or 1:99 mixture. Blood samples were taken for 30 minutes and the concentration of each of the two contrast media was measured by means of a double labeling technique with 125I and 131I. Relative concentrations of iohexol...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198511000-00016

    authors: Jensen LI,Dean PB,Nyman U,Golman K

    更新日期:1985-11-01 00:00:00

  • Embolization of superior mesenteric artery branches in dogs. Ischemic bowel changes depend on location of vessel occlusion and embolic materials.

    abstract:OBJECTIVE:To evaluate the degree of ischemic changes of the small intestine after arterial embolization of proximal or distal arteries with Gelfoam particles and coils in dogs. METHODS:Superselective arterial embolization in 18 dogs was performed using a coaxial catheter system. Gelfoam occlusion of the proximal level...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199910000-00004

    authors: Han YM,Lee JM,Jin KY,Lee SY,Kim CS

    更新日期:1999-10-01 00:00:00

  • Initial evaluation of non-contrast-enhanced magnetic resonance angiography in patients with peripheral arterial occlusive disease at 7 T.

    abstract:OBJECTIVES:The aim of this study was to achieve initial experience with non-contrast-enhanced (ne) magnetic resonance angiography (MRA) of the lower leg arteries in patients with peripheral arterial occlusive disease (PAOD) at 7 T. MATERIALS AND METHODS:Seven patients with PAOD were examined on a 7-T whole-body magnet...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000044

    authors: Fischer A,Maderwald S,Johst S,Orzada S,Ladd ME,Umutlu L,Lauenstein TC,Kniemeyer HW,Nassenstein K

    更新日期:2014-05-01 00:00:00

  • Intracranial arteriovenous malformations. Current imaging and treatment.

    abstract::Patients with intracranial arteriovenous malformations (AVM) can expect significant mortality (15% to 20%) and morbidity (20% to 30%) over a 15-year to 20-year period. Recent advances in interventional neuroradiology, neurosurgery, neuroanesthesia, and stereotactic radiotherapy provide the opportunity to obliterate ma...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199008000-00014

    authors: Graves VB,Duff TA

    更新日期:1990-08-01 00:00:00

  • Acute systemic and renal hemodynamic effects of meglumine/sodium diatrizoate 76% and iopamidol in euvolemic and dehydrated dogs.

    abstract::We examined the acute systemic and renal hemodynamic effects of intravenous meglumine/sodium diatrizoate-76% and iopamidol in euvolemic and dehydrated dogs. The physiologic responses were compared with acute changes in the level of an endogenous heparin-like material (EHM). One of eight dehydrated dogs receiving diatr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198610000-00005

    authors: Katzberg RW,Morris TW,Lasser EC,DiMarco PL,Merguerian PA,Ventura JA,Pabico RC,McKenna BA

    更新日期:1986-10-01 00:00:00

  • Automated calibration in vascular X-ray images using the accurate localization of catheter marker bands.

    abstract:RATIONALE AND OBJECTIVES:To develop a new automated calibration method for vessel measurements in vascular x-ray images. METHODS:Radiopaque marker bands mounted equidistantly on a small catheter were acquired in vitro at five image intensifier (II) sizes in x-ray projection images. The positions of the marker centers ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200004000-00002

    authors: Van Assen HC,Vrooman HA,Egmont-Petersen M,Bosch HG,Koning G,Van Der Linden EL,Goedhart B,Reiber JH

    更新日期:2000-04-01 00:00:00

  • Bone mineral analysis using single-energy computed tomography.

    abstract::We present a new method for evaluating in vivo changes in bone mineralization in the peripheral skeleton, using computed tomography (CT). A set of bone mineralization indices are generated from numerous CT images of the patient's distal radius. The cross-sectional anatomy displayed by the CT scan allows for separate e...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197903000-00003

    authors: Orphanoudakis SC,Jensen PS,Rauschkolb EN,Lang R,Rasmussen H

    更新日期:1979-03-01 00:00:00

  • Towards computer analysis of pulmonary infiltration.

    abstract::A feasibility study is described to provide quantitative texture measures to distinguish between normal lung, alveolar infiltrates and interstitial infiltrates. Advanced computer imaging technology and decision making processes were applied to distinguish between these textural patterns. The results, based on computer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00005

    authors: Tully RJ,Conners RW,Harlow CA,Lodwick GS

    更新日期:1978-07-01 00:00:00

  • Minimal spinal hyperostosis with low-dose isotretinoin therapy.

    abstract::Skeletal abnormalities have been reported on numerous occasions in patients who have received high doses of vitamin A and its derivatives. Recently, a new derivative, isotretinoin (Accutane, Hoffman-LaRoche, Inc.), has become available for the treatment of cystic acne. Ninety-six patients treated for a minimum of four...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198601000-00007

    authors: Kilcoyne RF,Cope R,Cunningham W,Nardella FA,Denman S,Franz TJ,Hanifin J

    更新日期:1986-01-01 00:00:00

  • Solid, part-solid, or non-solid?: classification of pulmonary nodules in low-dose chest computed tomography by a computer-aided diagnosis system.

    abstract:OBJECTIVES:The purpose of this study was to develop and validate a computer-aided diagnosis (CAD) tool for automatic classification of pulmonary nodules seen on low-dose computed tomography into solid, part-solid, and non-solid. MATERIALS AND METHODS:Study lesions were randomly selected from 2 sites participating in t...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1097/RLI.0000000000000121

    authors: Jacobs C,van Rikxoort EM,Scholten ET,de Jong PA,Prokop M,Schaefer-Prokop C,van Ginneken B

    更新日期:2015-03-01 00:00:00

  • Interventional atrioseptostomy by application of monopolar high-frequency alternating current. In vitro evaluation of a new device.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of a new device for interventional creation of atrial septal defects (ASD) working with high-frequency alternating current in an in vitro study with porcine atria. METHODS:The device consists of a symmetrical cage of six superelastic monofile wires, including a mic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199702000-00003

    authors: Grabitz RG,Handt S,Vanopbroeke HJ,Seghaye MC,Franke A,Osypka P,von Bernuth G

    更新日期:1997-02-01 00:00:00

  • Low-Dose Characterization of Kidney Stones Using Spectral Detector Computed Tomography: An Ex Vivo Study.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of kidney stone composition analysis using spectral detector computed tomography scanner (SDCT) with normal- and low-dose imaging protocols. METHODS:A total of 154 stones harvested from nephrolithotripsy or nephrolithotomy with a known monocrystalline...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000468

    authors: Große Hokamp N,Salem J,Hesse A,Holz JA,Ritter M,Heidenreich A,Maintz D,Haneder S

    更新日期:2018-08-01 00:00:00

  • Cine phase-contrast magnetic resonance imaging for analysis of flow phenomena in experimental aortic dissection.

    abstract::Using a 1.5 T magnetic resonance imaging (MRI) system, cine phase-contrast and magnitude images were obtained in three phantoms that simulated different anatomic configurations of aortic dissection. The dissection phantoms were made of compliant materials, and pulsatile flow was used in all experiments. Phantoms diffe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199112000-00007

    authors: Iwai F,Sostman HD,Evans AJ,Nadel SN,Hedlund LW,Beam CA,Charles HC,Spritzer CE

    更新日期:1991-12-01 00:00:00

  • Vascular alterations in canine histiocytic ulcerative colitis.

    abstract::The large intestines of eight boxer dogs with canine histiocytic ulcerative colitis (CHUC) and 10 normal dogs were studied by in vivo angiography and postmortem microangiography. The vascular abnormalities were correlated with the gross and histologic pathology found at necropsy. The angiographic abnormalities were ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197505000-00005

    authors: Lawson TL,Gomez JA,Margulis AR

    更新日期:1975-05-01 00:00:00

  • Collateral arterial formation. Lymph draining ischemic kidneys contains a neovascular stimulating agent of high molecular weight.

    abstract::An agent has been identified in lymph from rat kidneys rendered ischemic by partial renal artery occlusion that induces a striking neovascular response in a hamster cheek-pouch assay system. The factor has a high molecular weight, cannot be identified in lymph from normal kidneys, and is associated with a marked incre...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198501000-00015

    authors: Hollenberg NK,Paskins-Hurlburt AJ,Abrams HL

    更新日期:1985-01-01 00:00:00

  • The retropsoas recess. Demonstration using computed tomography.

    abstract::The retropsoas recess, a previously undescribed normal anatomic variant, is reported. In most individuals, the space posterior to the belly of the psoas muscle contains fat within the posterior pararenal space. However, a retrospective review of 250 consecutive CT examinations of the abdomen revealed 11 cases (4.4%) i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198707000-00004

    authors: Kelly RB,Mahoney PD,Frick MP

    更新日期:1987-07-01 00:00:00

  • A new animal model for testing renal tolerance of contrast agents.

    abstract:RATIONALE AND OBJECTIVES:To develop a new animal model for the evaluation of the renal tolerance of contrast agent and its application to diatrizoate and iotrolan injections in comparison to saline and mannitol solution. MATERIALS AND METHODS:The nephrotoxic potential of intravenously injected contrast agents in Beagl...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000087096.61127.13

    authors: Krause W,Gilles T

    更新日期:2003-11-01 00:00:00

  • Clinical safety and diagnostic value of the gadolinium chelate gadoterate meglumine (Gd-DOTA).

    abstract:OBJECTIVE:The purpose of this study was to assess the diagnostic value and safety of the contrast agent gadoterate meglumine (Gd-DOTA, DOTAREM, Guerbet, Roissy CdG Cedex, France) in the setting of a postmarketing surveillance study. MATERIALS AND METHODS:Between January 2004 and October 2005, radiologists in 61 radiol...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000248893.01067.e5

    authors: Herborn CU,Honold E,Wolf M,Kemper J,Kinner S,Adam G,Barkhausen J

    更新日期:2007-01-01 00:00:00

  • The effect of radiographic contrast media on leukocyte motility.

    abstract:RATIONALE AND OBJECTIVES:Studies describing the effects of radiographic contrast media (RCM) in leukocyte chemotaxis have been contradictory. No studies have been performed after in-vivo exposure. The authors assess the effect of RCM on leukocytes following in-vivo exposure. METHODS:Seventeen patients were studied aft...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199401000-00012

    authors: Roobottom CA,Farrow R,Wells IP,Hurlock-Fimls N

    更新日期:1994-01-01 00:00:00

  • Polycystic kidney disease evaluation by magnetic resonance imaging in ischemia-reperfusion injured PKD1 knockout mouse model: comparison of T2-weighted FSE and true-FISP.

    abstract:OBJECTIVE:To investigate the efficacy of true fast imaging with steady state precession (true-FISP) compared with T2-weighted fast spin echo (T2W-FSE) in monitoring changes in cyst volume and renal expansion in an ischemia reperfusion (IR) injured PKD1 knockout (IKO) mouse model. MATERIALS AND METHODS:The animal study...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181be3501

    authors: Zhou X,Bao H,Takakura A,Zhou J,Albert M,Sun Y

    更新日期:2010-01-01 00:00:00

  • Keratinization and necrosis. Morphologic aspects of lymphatic metastases in ultrasound.

    abstract:RATIONALE AND OBJECTIVE:The authors performed a retrospective study in ultrasound to investigate new aspects in the sonomorphology of lymph node metastases of the neck. In this study, it could be demonstrated the first time that the histologic characteristics of the metastases determine the sonographic appearance. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199609000-00001

    authors: Mäurer J,Willam C,Steinkamp HJ,Knollmann FD,Felix R

    更新日期:1996-09-01 00:00:00