Abstract:
:A feasibility study is described to provide quantitative texture measures to distinguish between normal lung, alveolar infiltrates and interstitial infiltrates. Advanced computer imaging technology and decision making processes were applied to distinguish between these textural patterns. The results, based on computer extracted quantitative measures, show an excellent separation of the three classes considered with 95% accuracy in the training phase and 90% accuracy in the testing phase.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Tully RJ,Conners RW,Harlow CA,Lodwick GSdoi
10.1097/00004424-197807000-00005subject
Has Abstractpub_date
1978-07-01 00:00:00pages
298-305issue
4eissn
0020-9996issn
1536-0210journal_volume
13pub_type
杂志文章abstract::Using cardiac-gated fast acquisition with multiple excitation (FAME), time curves of the cerebral aqueduct signals were derived in 19 healthy volunteers and 14 patients. A mean curve of the normal subjects was determined during systole. A relatively stable point of time was found at 270 msec after the R-wave supposed ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198911000-00004
更新日期:1989-11-01 00:00:00
abstract::In order to measure the accuracy of a diagnostic imaging technique, the correctness of each observer decision must be determined. This is often difficult in clinical cases, and various strategies are frequently used to approximate the truth. Experiments using chest radiographs as an example are reported to show the pi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198303000-00018
更新日期:1983-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Diabetic patients frequently suffer contrast media-induced nephropathy. Hyperglycemia in diabetes mellitus causes gradual deterioration of glomerular mesangial cells (MCs) in the kidney. In this study, the authors investigated the response of rat MCs cultured in high-glucose medium to diatrizoa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200107000-00001
更新日期:2001-07-01 00:00:00
abstract::Four-hour delayed contrast-enhanced computed tomography (DCECT) shows promise for improved detection of focal liver lesions. No previous studies have examined the use of nonionic contrast materials for DCECT. The authors undertook a case-controlled study in monkeys to define the relative efficacies of iopamidol and di...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198910000-00010
更新日期:1989-10-01 00:00:00
abstract::Iohexol and meglumine-sodium diatrizoate were injected intravenously into 18 pigs as either a 99:1 or 1:99 mixture. Blood samples were taken for 30 minutes and the concentration of each of the two contrast media was measured by means of a double labeling technique with 125I and 131I. Relative concentrations of iohexol...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198511000-00016
更新日期:1985-11-01 00:00:00
abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198602000-00015
更新日期:1986-02-01 00:00:00
abstract::Twenty-six patients who had received 43 grafts were studied before and after coronary artery vein bypass surgery. Cine ventriculograms taken in the right anterior oblique projection were analyzed and regional ejection fractions calculated. Single and multiple grafts were considered separately as were thrombosed and pa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197705000-00001
更新日期:1977-05-01 00:00:00
abstract::The study aim was to define potential differences and advantages in magnetic resonance (MR) patterns of tumoral contrast enhancement using either a small molecular, extracellular fluid contrast enhancer [Gd-DTPA] or a macromolecular agent [albumin-(Gd-DTPA)20], designed for primary intravascular biodistribution. MR im...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198908000-00007
更新日期:1989-08-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. MATERIALS AND METHODS:The institutional review board approved this study, and all patients pr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182562a89
更新日期:2012-08-01 00:00:00
abstract:INTRODUCTION:Attenuation correction for magnetic resonance (MR) coils is a new challenge that came about with the development of combined MR and positron emission tomography (PET) imaging. This task is difficult because such coils are not directly visible on either PET or MR acquisitions with current combined scanners ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182a530f8
更新日期:2014-02-01 00:00:00
abstract::We studied 60 male patients who had concurrent chest films (CXR), computed tomography scans (CT) and pulmonary function tests (PFT) to assess the sensitivity of CT and conventional films in detecting emphysema compared with PFT. We also sought to determine whether emphysema could be diagnosed by CT in patients with no...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198804000-00004
更新日期:1988-04-01 00:00:00
abstract:PURPOSE:The aim of this study was to identify the signal intensity (SI) changes in the dentate nucleus (DN) and the globus pallidus (GP) on unenhanced T1-weighted magnetic resonance (MR) images after multiple administration of gadolinium-based contrast agents (GBCAs) in children and compare those changes between linear...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000436
更新日期:2018-04-01 00:00:00
abstract::An agent has been identified in lymph from rat kidneys rendered ischemic by partial renal artery occlusion that induces a striking neovascular response in a hamster cheek-pouch assay system. The factor has a high molecular weight, cannot be identified in lymph from normal kidneys, and is associated with a marked incre...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198501000-00015
更新日期:1985-01-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to assess and compare the overall performance, reliability, variability, as well as the accuracy of diffusion tensor imaging (DTI) and fiber tracking metrics, for the muscles of the calf at 3 T and 7 T. MATERIALS AND METHODS:Ten volunteers (5 males; mean age, 29.1 ± 4.7 years), with...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000508
更新日期:2019-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study was devised to develop a method of measuring the acute effects of radiocontrast media on renal function and assessing the relationship of the dose of radiocontrast media infused with the incidence of radiocontrast-induced renal failure. In addition, the drug adenosine phosphate-magne...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00004424-199406000-00004
更新日期:1994-06-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to evaluate the use of dielectric pads for improving high spatial resolution imaging of the inner ear at 7 T. MATERIALS AND METHODS:Two sets of dielectric pads were designed using electromagnetic simulations and implemented using a deuterated suspension of barium titanate. Th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000026
更新日期:2014-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000133816.83192.38
更新日期:2004-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the feasibility of mechanical thrombectomy in occluded hemodialysis access shunts by using a newly developed 5F pigtail rotation catheter. METHODS:Thrombosed hemodialysis access shunts were simulated by clotted bovine blood in silicone tubing (diameter 6 mm). After retrograde and a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199907000-00008
更新日期:1999-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The effect of breathholding on pulmonary perfusion remains largely unknown. The aim of this study was to assess the effect of inspiratory and expiratory breathhold on pulmonary perfusion using quantitative pulmonary perfusion magnetic resonance imaging (MRI). METHODS AND RESULTS:Nine healthy v...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000149252.42679.78
更新日期:2005-02-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to evaluate the influence of different weighting factors on contrast enhancement, signal-to-noise ratio (SNR), and image quality in image fusion in dual energy computed tomography (DECT) angiography. MATERIAL AND METHODS:Fifteen patients underwent a CT angiography of the aorta with ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31818c3d4b
更新日期:2009-01-01 00:00:00
abstract::Computed tomography followed by sectional radiography and photography as performed on eight cadaveric specimens in order to define the anatomy and normal motion of both the proximal and the distal radioulnar articulations. Osseous landmarks were defined that allowed measurement of rotation at the glenohumeral, proxima...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198311000-00012
更新日期:1983-11-01 00:00:00
abstract::We have examined the metabolic behavior of several triiodobenzoic acid derivatives because of the observed mutagenicity and cytotoxicity of 3-amino-5-acetamido-2,4,6-triiodobenzoate (I) and 3,5-diamino-2,4,6-triiodobenzoate (II). Measurements were facilitated using iodine-131 (131I)-labeled compounds. Drug retention i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1981-11-01 00:00:00
abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198011001-00053
更新日期:1980-11-01 00:00:00
abstract::Trypan blue and 197HgCl2 were used as markers of the increased leakage through the blood-brain barrier which developed after selective injection of different contrast media formulations into the internal carotid arteries of rabbits. Interest was focused on a new, experimental, nonionic medium (C-29) and possible effec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197907000-00007
更新日期:1979-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Indium-111 (111In)-labeled leukocyte scanning has been used frequently in patients suspected of having infections. Recently, technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) has been used to label leukocytes. This study was undertaken to determine the distribution and dosimetry of 9...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199404000-00010
更新日期:1994-04-01 00:00:00
abstract::Magnetic resonance angiography (MRA) for application in the musculoskeletal system is progressing at a rapid pace. The clinical role of this new technique is still being developed, although a number of uses have already become well recognized, and MRA is diffusing into clinical practice. This article describes the bas...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199212002-00014
更新日期:1992-12-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to assess the impact of oral water and intravenous furosemide challenges on blood oxygenation level-dependent magnetic resonance imaging measurements in the kidney and to examine the contribution of R2 (=1/T2) to changes in R2* (=1/T2*). MATERIALS AND METHODS:This Health Insurance ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182823591
更新日期:2013-07-01 00:00:00
abstract:OBJECTIVES:X-ray computed tomography (CT) using phase contrast can provide images with greatly enhanced soft-tissue contrast in comparison to conventional attenuation-based CT. We report on the first scan of a human specimen recorded with a phase-contrast CT system based on an x-ray grating interferometer and a convent...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181e21866
更新日期:2010-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200204000-00003
更新日期:2002-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVE:To estimate the sensitivity to find small coronary artery calcium lesions with use of different slice widths with electron beam tomography. MATERIALS AND METHODS:Two studies were performed. Study 1 utilized double scanning of a stationary cork phantom with three different slice thickness (1.5, ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.RLI.0000055289.97726.B1
更新日期:2003-03-01 00:00:00