Initial evaluation of non-contrast-enhanced magnetic resonance angiography in patients with peripheral arterial occlusive disease at 7 T.

Abstract:

OBJECTIVES:The aim of this study was to achieve initial experience with non-contrast-enhanced (ne) magnetic resonance angiography (MRA) of the lower leg arteries in patients with peripheral arterial occlusive disease (PAOD) at 7 T. MATERIALS AND METHODS:Seven patients with PAOD were examined on a 7-T whole-body magnetic resonance system. A custom-built 16-channel transmit/receive coil and a manually positionable AngioSURF table were used for multistation imaging. For ne-MRA, an axial T1-weighted Turbo-fast low angle shot sequence (repetition time, 700 milliseconds; echo time, 3.84 milliseconds; bandwidth, 930 Hz/pixel; voxel volume, 1 × 1 × 2 mm; matrix, 384 × 288) with phonocardiogram gating was acquired at 7 T. Acquisition time of an entire angiogram covering the vasculature from pelvis to feet amounted to approximately 30 minutes, depending on the patient's heart frequency. All patients underwent a contrast-enhanced MRA (ce-MRA) at 1.5 T as standard of reference. The presence of stenosis and occlusions was evaluated segment based and compared for both MRA techniques. The degree of stenosis was defined as low grade (<50%), high grade (50%-99%), and occlusion (100%). High-grade stenosis and occlusion were considered to be hemodynamically significant stenosis. RESULTS:The 7-T ne-MRA enabled a homogenous, hyperintense artery signal and nearly total venous suppression with accurate delineation of arterial anatomy both proximal and distal to stenotic disease. A total of 154 artery segments were depicted with ce-MRA at 1.5 T. At 7 T, only 124 segments (80.5%) were displayed and involved for analysis, as the iliacal region was displayed incompletely in 4 patients because of the fact that the fixed coil diameter was too small to contain the lower abdomen and pelvis of these patients. In comparison with ce-MRA at 1.5 T as the reference standard, there was total agreement regarding the characterization of an artery segment as being normal or having any kind of stenosis. Of the 124 included segments, 28 segments (23%) had hemodynamically significant stenosis evaluated with 7-T ne-MRA and 26 segments (21%) assessed with 1.5-T ce-MRA. The sensitivity and specificity values of 7-T ne-MRA for detecting segments with hemodynamically significant stenosis were 93% and 98%, respectively. CONCLUSIONS:Non-contrast-enhanced MRA by means of T1-weighted Turbo-fast low angle shot imaging at 7 T in patients with PAOD is feasible and allowed for good visualization of stenosis and occlusions in all analyzed artery segments in this small patient group. However, this study also shows the challenges of ultrahigh-field body imaging, and more experience is required to determine the impact of 7-T ne-MRA in clinical practice.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Fischer A,Maderwald S,Johst S,Orzada S,Ladd ME,Umutlu L,Lauenstein TC,Kniemeyer HW,Nassenstein K

doi

10.1097/RLI.0000000000000044

subject

Has Abstract

pub_date

2014-05-01 00:00:00

pages

331-8

issue

5

eissn

0020-9996

issn

1536-0210

journal_volume

49

pub_type

杂志文章
  • Comparison of Gd(DTPA-BMA) (Omniscan) versus Gd(HP-DO3A) (ProHance) relative to gadolinium retention in human bone tissue by inductively coupled plasma mass spectroscopy.

    abstract:OBJECTIVE:The objective of this study was to determine the gadolinium (Gd) concentration remaining in human bone tissue after administration of standard clinical doses of 2 Gd-based contrast agents: ProHance and Omniscan. MATERIALS AND METHODS:After administration of 0.1 mmol/kg of Gd chelate to patients undergoing hi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000186569.32408.95

    authors: White GW,Gibby WA,Tweedle MF

    更新日期:2006-03-01 00:00:00

  • Granulocyte accumulation in the transplanted liver does not correlate with clinical and histologic evidence of dysfunction.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the role of granulocytes in reperfusion injury after liver transplantation. The authors injected radiolabeled granulocytes to determine if human liver graft outcome could be correlated with granulocyte accumulation. MATERIALS AND METHODS:Pure granulocyte suspension was prepared fro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199603000-00003

    authors: Ziser A,Forstrom LA,Plevak DJ,Sanchez-Urdazpal L,Gores GJ,Wiesner RH,Batts KP,Krom RA

    更新日期:1996-03-01 00:00:00

  • Lung perfusion demonstrated by contrast-enhanced dynamic magnetic resonance imaging. Application to unilateral lung transplantation.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of magnetic resonance (MR) to image pulmonary perfusion in healthy controls and to detect pulmonary defects in patients with unilateral lung transplantation, using dynamic images after contrast administration. METHODS:Five patients with right lung transplantation a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199706000-00006

    authors: Berthezène Y,Croisille P,Bertocchi M,Houzard C,Bendib K,Revel D

    更新日期:1997-06-01 00:00:00

  • Low-dose transaxial tomography. An alternative to computed tomography for the evaluation of anteversion of the femur during childhood.

    abstract::Low-dose transaxial tomography is a technique that can produce cross-sectional images of the hips and femurs in children to permit calculation of the angle of femoral anteversion. Transaxial tomography was compared with computed tomography in terms of measured radiation dose and image quality. Transaxial tomography wa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kushner DC,Cleveland RH,Ehrlich MG,Zaleske DJ,DeLuca SA,Herman TE,Webster EW

    更新日期:1985-12-01 00:00:00

  • Detection and characterization of crystal suspensions using single-source dual-energy computed tomography: a phantom model of crystal arthropathies.

    abstract:OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000099

    authors: Diekhoff T,Kiefer T,Stroux A,Pilhofer I,Juran R,Mews J,Blobel J,Tsuyuki M,Ackermann B,Hamm B,Hermann KG

    更新日期:2015-04-01 00:00:00

  • Reflux of ethanol during experimental liver ethanol injections.

    abstract:RATIONALE AND OBJECTIVES:The reflux of ethanol into the peritoneal cavity during percutaneous ethanol injection therapy (PEIT) of liver neoplasms may cause pain and other side effects. This article studies the optimal injection technique to minimize the reflux of ethanol. METHODS:A technique using normal postmortem pi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199211000-00008

    authors: Vehmas T

    更新日期:1992-11-01 00:00:00

  • Collateral arterial formation. Lymph draining ischemic kidneys contains a neovascular stimulating agent of high molecular weight.

    abstract::An agent has been identified in lymph from rat kidneys rendered ischemic by partial renal artery occlusion that induces a striking neovascular response in a hamster cheek-pouch assay system. The factor has a high molecular weight, cannot be identified in lymph from normal kidneys, and is associated with a marked incre...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198501000-00015

    authors: Hollenberg NK,Paskins-Hurlburt AJ,Abrams HL

    更新日期:1985-01-01 00:00:00

  • The pediatric tracheostomy: III). An appraisal of xerography.

    abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00002

    authors: Scott JR,Kramer SS,Griscom NT

    更新日期:1978-07-01 00:00:00

  • Comparison of gadobenate dimeglumine with gadopentetate dimeglumine for magnetic resonance imaging of liver tumors.

    abstract:RATIONALE AND OBJECTIVES:To compare gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for magnetic resonance imaging of the liver. METHODS:The contrast agent Gd-BOPTA or Gd-DTPA was administered at a dose of 0.1 mmol/kg to 257 patients suspected of having malignant liver tumors. Dynamic phase ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200111000-00002

    authors: Kuwatsuru R,Kadoya M,Ohtomo K,Tanimoto A,Hirohashi S,Murakami T,Tanaka Y,Yoshikawa K,Katayama H

    更新日期:2001-11-01 00:00:00

  • Visualization of breast lymphatic pathways with an indirect computed tomography lymphography using a nonionic monometric contrast medium iopamidol: preliminary results.

    abstract:RATIONALE AND OBJECTIVES:The capability of an indirect computed tomographic lymphography (CT-LG) using a nonionic monometric contrast medium iopamidol for visualizing breast lymphatic pathways was preliminarily tested. MATERIALS AND METHODS:In 10 female dogs, a total of 0.5 and 1 mL of undiluted iopamidol was injected...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200302000-00002

    authors: Suga K,Ogasawara N,Yuan Y,Okada M,Matsunaga N,Tangoku A

    更新日期:2003-02-01 00:00:00

  • Normal renal blood flow measurement using phase-contrast cine magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:This study assesses the ability of a cardiac-gated phase-contrast magnetic resonance imaging (MRI) technique to measure renal blood flow (RBF) noninvasively in humans. METHODS:In nine normal volunteers, total RBF in the renal arteries and in the left renal vein was estimated by MRI and correla...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199206000-00012

    authors: Sommer G,Noorbehesht B,Pelc N,Jamison R,Pinevich AJ,Newton L,Myers B

    更新日期:1992-06-01 00:00:00

  • Cine phase-contrast magnetic resonance imaging for analysis of flow phenomena in experimental aortic dissection.

    abstract::Using a 1.5 T magnetic resonance imaging (MRI) system, cine phase-contrast and magnitude images were obtained in three phantoms that simulated different anatomic configurations of aortic dissection. The dissection phantoms were made of compliant materials, and pulsatile flow was used in all experiments. Phantoms diffe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199112000-00007

    authors: Iwai F,Sostman HD,Evans AJ,Nadel SN,Hedlund LW,Beam CA,Charles HC,Spritzer CE

    更新日期:1991-12-01 00:00:00

  • Improving CT-Based PET Attenuation Correction in the Vicinity of Metal Implants by an Iterative Metal Artifact Reduction Algorithm of CT Data and Its Comparison to Dual-Energy-Based Strategies: A Phantom Study.

    abstract:OBJECTIVE:The aim of this study was to evaluate the potential of iterative metal artifact reduction (IMAR) for the improvement of computed tomography (CT)-based position emission tomography (PET) attenuation correction in the vicinity of metal implants and compare it with dual-energy-based metal artifact reduction stra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000306

    authors: Schabel C,Gatidis S,Bongers M,Hüttig F,Bier G,Kupferschlaeger J,Bamberg F,la Fougère C,Nikolaou K,Pfannenberg C

    更新日期:2017-01-01 00:00:00

  • Feasibility of real-time magnetic resonance-guided angioplasty and stenting of renal arteries in vitro and in Swine, using a new polyetheretherketone-based magnetic resonance-compatible guidewire.

    abstract:OBJECTIVES:Demonstrate the usability of a new polyetheretherketone (PEEK)-based MR-compatible guidewire for renal artery catheterization, angioplasty, and stenting under MR-guidance using MR-visible markers, in vitro and in vivo. MATERIAL AND METHODS:The new 0.035'' guidewire with fiber-reinforced PEEK core, a soft ti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31819b00f1

    authors: Kos S,Huegli R,Hofmann E,Quick HH,Kuehl H,Aker S,Kaiser GM,Borm PJ,Jacob AL,Bilecen D

    更新日期:2009-04-01 00:00:00

  • T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning.

    abstract:OBJECTIVES:The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. MATERIALS AND METHODS:Ten pat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000381

    authors: Freedman JN,Collins DJ,Bainbridge H,Rank CM,Nill S,Kachelrieß M,Oelfke U,Leach MO,Wetscherek A

    更新日期:2017-10-01 00:00:00

  • Hepatocellular carcinoma: correlation between vascular endothelial growth factor level and degree of enhancement by multiphase contrast-enhanced computed tomography.

    abstract:RATIONALE AND OBJECTIVES:To determine whether vascular endothelial growth factor (VEGF) is a histopathological factor influencing contrast enhancement of hepatocellular carcinoma (HCC) on computed tomography (CT). METHODS:Twenty-two nodular HCCs underwent multiphase helical CT and surgery. Tumor size, histological gra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200108000-00008

    authors: Kwak BK,Shim HJ,Park ES,Kim SA,Choi D,Lim HK,Park CK,Chung JW,Park JH

    更新日期:2001-08-01 00:00:00

  • Cerebral embolization in rats induced by red blood cells treated with hypertonic X-ray contrast medium.

    abstract:RATIONALE AND OBJECTIVES:Hypertonic X-ray contrast media induce morphologic changes in red blood cells (RBCs) and reduce their deformability when measured in vitro. This study investigated whether RBCs treated with hypertonic contrast media could induce circulatory as well as metabolic disturbances in vivo. METHODS:Au...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Miyazawa T,Murayama C,Yamanaka T,Fritz-Zieroth B

    更新日期:1993-09-01 00:00:00

  • Contrast-enhanced MRI of tumors. Comparison of Gd-DTPA and a macromolecular agent.

    abstract::The study aim was to define potential differences and advantages in magnetic resonance (MR) patterns of tumoral contrast enhancement using either a small molecular, extracellular fluid contrast enhancer [Gd-DTPA] or a macromolecular agent [albumin-(Gd-DTPA)20], designed for primary intravascular biodistribution. MR im...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198908000-00007

    authors: Wikström MG,Moseley ME,White DL,Dupon JW,Winkelhake JL,Kopplin J,Brasch RC

    更新日期:1989-08-01 00:00:00

  • A large animal model (swine) to study the diagnosis and treatment of cholelithiasis.

    abstract::Human gallstones were surgically placed into the gallbladders of 200 swine. Eight of these swine were used as a prospective series to verify that the placement and presence of human gallstones in their gallbladders caused no significant pathologic changes in the gallbladder and that the gallstones were not spontaneous...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198902000-00005

    authors: Griffith SL,Burney BT,Fry FJ,Franklin TD Jr

    更新日期:1989-02-01 00:00:00

  • Does dilution of contrast media affect contrast enhancement? An experimental study in rats.

    abstract::The effect of contrast media (CM) dilution on contrast enhancement was studied using CM representing four structurally different molecular types at osmolalities ranging from 135 to 1340 mosm/kg. Diatrizoate (ionic monomer), iopamidol (nonionic monomer), ioxaglate (ionic dimer), and iodecol (nonionic dimer) were each g...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00014

    authors: Dean PB,Kivisaari L,Kormano M

    更新日期:1988-09-01 00:00:00

  • Perfusion quantitation by ultrafast computed tomography.

    abstract::Flow measurements can be made with computed tomography (CT) scanners using iodinated, nonionic contrast media as a first-pass indicator. Ultrafast CT (UFCT) is an ideal machine to make these measurements because of its short scan time (50 mseconds) and interscan delay (< or = 0.6 seconds). Additionally, UFCT can acqui...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199212002-00004

    authors: Gould RG

    更新日期:1992-12-01 00:00:00

  • Magnetization transfer and high-dose contrast in early brain infection on magnetic resonance.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the effect of contrast dose, use of magnetization transfer (MT), and temporal delay on the visualization of contrast enhancement with gadoteridol (Gd HP-DO3A) in a canine brain abscess model. METHODS:Alpha streptococcus brain abscesses were studied in five dogs at 1.5 tesla...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199503000-00001

    authors: Runge VM,Wells JW,Kirsch JE

    更新日期:1995-03-01 00:00:00

  • Intravoxel incoherent motion diffusion-weighted imaging of pancreatic neuroendocrine tumors: prediction of the histologic grade using pure diffusion coefficient and tumor size.

    abstract:PURPOSE:The purpose of this study was to assess the value of intravoxel incoherent motion and diffusion-weighted imaging for predicting the histologic grade of pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:Forty patients with surgically diagnosed PNETs who underwent preoperative magnetic resonance im...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000028

    authors: Hwang EJ,Lee JM,Yoon JH,Kim JH,Han JK,Choi BI,Lee KB,Jang JY,Kim SW,Nickel MD,Kiefer B

    更新日期:2014-06-01 00:00:00

  • Retention of iodine and expression of biomarkers for renal damage in the kidney after application of iodinated contrast media in rats.

    abstract:OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318190fbd2

    authors: Jost G,Pietsch H,Sommer J,Sandner P,Lengsfeld P,Seidensticker P,Lehr S,Hütter J,Sieber MA

    更新日期:2009-02-01 00:00:00

  • Degenerative disease of the sacroiliac joint.

    abstract::Analysis of 46 sacroiliac joints removed in toto at random during routine autopsies was undertaken to define the pathologic and radiographic alterations of this joint in middle-aged and elderly patients. Each joint was sectioned, photographed and radiographed and large microscopic slides were prepared. Sacroiliac oste...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197511000-00008

    authors: Resnick D,Niwayama G,Goergen TG

    更新日期:1975-11-01 00:00:00

  • Fluorinated blood substitute retention in the rat measured by fluorine-19 magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199208000-00012

    authors: Meyer KL,Carvlin MJ,Mukherji B,Sloviter HA,Joseph PM

    更新日期:1992-08-01 00:00:00

  • Safety and Oncologic Outcomes of Magnetic Resonance Imaging-Guided Cryoablation of Renal Cell Carcinoma: A 10-Year Single-Center Experience.

    abstract:OBJECTIVES:Magnetic resonance imaging guidance has been sporadically reported for renal tumor cryoablation (CA); therefore, clinical experience with this modality is still limited.The aim of this study is to retrospectively analyze our 10-year experience with renal tumor CA performed on a 1.5 T magnetic resonance imagi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000719

    authors: Cazzato RL,De Marini P,Leonard-Lorant I,Leclerc L,Auloge P,Tricard T,Dalili D,Garnon J,Lang H,Gangi A

    更新日期:2020-09-04 00:00:00

  • Dechelation (Transmetalation): Consequences and Safety Concerns With the Linear Gadolinium-Based Contrast Agents, In View of Recent Health Care Rulings by the EMA (Europe), FDA (United States), and PMDA (Japan).

    abstract::The issue of dechelation (transmetallation) in vivo after administration of the linear gadolinium-based contrast agents, and potential safety concerns, is considered on the basis of an extensive, focused literature review. Early indications of potential problems included the high level of excess ligand used in the for...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000507

    authors: Runge VM

    更新日期:2018-10-01 00:00:00

  • Experimental pulmonary arteritis.

    abstract::Experimental pulmonary arteritis was produced in rabbits by intravenous injection of alveolar macrophages from donor rabbits. These animals, along with matched controls, were studied with pulmonary angiography to test the hypothesis that angiography could detect the vasculitic process in life. The animals were then sa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198007000-00005

    authors: Hicken P,Hogg JC,Pare PD

    更新日期:1980-07-01 00:00:00

  • Effect of intraarticular pressure on patellar position. Computed tomography study in cadaveric specimens.

    abstract:RATIONALE AND OBJECTIVES:The purpose of the study was to evaluate the effect of articular fluid distention on patellar position at different degrees of knee angulation. METHODS:Patellar position in 10 cadaveric knee specimens was determined with 30, 100, and 200 mm Hg joint distention at 45, 20, and 5 degrees of knee ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199602000-00001

    authors: Brossmann J,Koch S,Schwarzenberg H,Link J,Muhle C,Bull CC,Heller M

    更新日期:1996-02-01 00:00:00