Comparison of Gd(DTPA-BMA) (Omniscan) versus Gd(HP-DO3A) (ProHance) relative to gadolinium retention in human bone tissue by inductively coupled plasma mass spectroscopy.

Abstract:

OBJECTIVE:The objective of this study was to determine the gadolinium (Gd) concentration remaining in human bone tissue after administration of standard clinical doses of 2 Gd-based contrast agents: ProHance and Omniscan. MATERIALS AND METHODS:After administration of 0.1 mmol/kg of Gd chelate to patients undergoing hip replacement surgery, bone specimens were collected and analyzed, and compared with an age-matched control population without a history of Gd chelate administration. Bone specimens were collected fresh, refrigerated, and subsequently frozen. After grinding and freeze-drying, tissue digestion was performed using Teflon bombs and concentrated nitric acid. A method for analysis of Gd in bone specimens was developed and validated using inductively coupled plasma mass spectroscopy (ICP-MS). RESULTS:Results were compared with a previous study using a different technique for analysis of the same tissue specimens. Tissue retention was 1.77+/-0.704 microg Gd/g bone (n=9) for Omniscan and 0.477+/-0.271 microg Gd/g bone (n=10) for ProHance measured by ICP-MS. These findings confirmed results from the previous ICP-AES study. CONCLUSION:Omniscan (Gd[DTPA-BMA]) left approximately 4 times (previous study 2.5 times) more Gd behind in bone than did ProHance (Gd[HP-DO3A]).

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

White GW,Gibby WA,Tweedle MF

doi

10.1097/01.rli.0000186569.32408.95

keywords:

subject

Has Abstract

pub_date

2006-03-01 00:00:00

pages

272-8

issue

3

eissn

0020-9996

issn

1536-0210

pii

00004424-200603000-00010

journal_volume

41

pub_type

杂志文章
  • Minimal spinal hyperostosis with low-dose isotretinoin therapy.

    abstract::Skeletal abnormalities have been reported on numerous occasions in patients who have received high doses of vitamin A and its derivatives. Recently, a new derivative, isotretinoin (Accutane, Hoffman-LaRoche, Inc.), has become available for the treatment of cystic acne. Ninety-six patients treated for a minimum of four...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198601000-00007

    authors: Kilcoyne RF,Cope R,Cunningham W,Nardella FA,Denman S,Franz TJ,Hanifin J

    更新日期:1986-01-01 00:00:00

  • Applications of voxel shifting in magnetic resonance imaging.

    abstract::Due to the nature of three-dimensional Fourier transform (3-DFT) data acquisition in magnetic resonance imaging (MRI), the spatial relation between a resolved volume element (a voxel) and the object can be manipulated easily. Those manipulations have practical consequences in terms of registering slice positions with ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199012000-00006

    authors: Kramer D,Li A,Simovsky I,Hawryszko C,Hale J,Kaufman L

    更新日期:1990-12-01 00:00:00

  • MR cholangiopancreatography at 3.0 T: intraindividual comparative study with MR cholangiopancreatography at 1.5 T for clinical patients.

    abstract:OBJECTIVES:To prospectively evaluate the image quality and diagnostic accuracy of magnetic resonance cholangiopancreatography (MRCP) at 3.0 T compared with that at 1.5 T used for patients. MATERIALS AND METHODS:This study was approved by our institutional review board, and informed consent was obtained from all patien...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b4c0ae

    authors: Onishi H,Kim T,Hori M,Murakami T,Tatsumi M,Nakaya Y,Nakamoto A,Osuga K,Tomoda K,Nakamura H

    更新日期:2009-09-01 00:00:00

  • Ultrasound Time-Harmonic Elastography of the Pancreas: Reference Values and Clinical Feasibility.

    abstract:OBJECTIVES:Pancreatic ductal adenocarcinoma (PDAC) is a very aggressive tumor with a very low 5-year survival rate of 8%. The aims of this study are to determine reference values and physiologic confounders in healthy pancreas and to assess the diagnostic accuracy of ultrasound time-harmonic elastography (THE) in the d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000638

    authors: Burkhardt C,Tzschätzsch H,Schmuck R,Bahra M,Jürgensen C,Pelzer U,Hamm B,Braun J,Sack I,Marticorena Garcia SR

    更新日期:2020-05-01 00:00:00

  • Photographic unsharp masking in chest radiography.

    abstract::A photographic unsharp masking technique for improving the latitude of chest radiographs without sacrificing image contrast or detail is described. An unsharp mask film, prepared from a scout film of the patient's chest, is placed between the film and the front (entrance) screen in the cassette. A second radiograph th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198107000-00007

    authors: Sorenson JA,Niklason LT,Nelson JA

    更新日期:1981-07-01 00:00:00

  • Pharmacokinetics and safety of iomeprol in healthy volunteers and in patients with renal impairment or end-stage renal disease requiring hemodialysis.

    abstract:RATIONALE AND OBJECTIVES:To present the results of two studies conducted to evaluate the pharmacokinetics and safety of iomeprol in healthy volunteers and in patients with various degrees of renal impairment. METHODS:In these two open-label, single-dose, phase I studies, a 50-mL dose of iomeprol 400 was administered i...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-200106000-00002

    authors: Lorusso V,Taroni P,Alvino S,Spinazzi A

    更新日期:2001-06-01 00:00:00

  • Accuracy of ultrasound in fetal femur length determination. Ultrasound phantom study.

    abstract::An ultrasound phantom was constructed simulating fetal femurs in amniotic fluid. Bones of 26, 36, 50, 58, and 70 mm, representative of gestational ages ranging from 17 to 36 weeks, were scanned with mechanical sector, phased sector, and linear array systems (ATL, Diasonics, Acuson, and GE). Measurements were made with...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198505000-00016

    authors: Gamba JL,Bowie JD,Dodson WC,Hedlund LW

    更新日期:1985-05-01 00:00:00

  • Prediction of antiangiogenic treatment efficacy by iron oxide enhanced parametric magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Tools for monitoring modern target-specific antiangiogenic and antivascular therapies are highly desirable because treatment strategies are time consuming, expensive, and yet sometimes ineffective. Therefore, the aim of this experimental study was to evaluate the predictive value of steady-stat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3180d5cbd9

    authors: Persigehl T,Matuszewski L,Kessler T,Wall A,Meier N,Ebert W,Berdel WE,Heindel W,Mesters R,Bremer C

    更新日期:2007-12-01 00:00:00

  • Development of a macromolecular dual-modality MR-optical imaging for sentinel lymph node mapping.

    abstract:OBJECTIVE:To evaluate the effectiveness of a dual magnetic resonance-near infrared fluorescence optical imaging agent, poly(l-glutamic acid)-DTPA-Gd-NIR813, for both preoperative and intraoperative visualization and characterization of sentinel lymph nodes (SLN) in mice. MATERIALS AND METHODS:Poly(L-glutamic acid) was...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31804f5a79

    authors: Melancon MP,Wang Y,Wen X,Bankson JA,Stephens LC,Jasser S,Gelovani JG,Myers JN,Li C

    更新日期:2007-08-01 00:00:00

  • Microbubble contrast agents: targeted ultrasound imaging and ultrasound-assisted drug-delivery applications.

    abstract::The use of microbubble contrast agents for general tissue delineation and perfusion enjoys steady interest in ultrasound imaging. Microbubbles as contrast materials require a small dosage and show excellent detection sensitivity. Targeting ligands on the surface of microbubbles permit the selective accumulation of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/01.rli.0000199292.88189.0f

    authors: Klibanov AL

    更新日期:2006-03-01 00:00:00

  • Incidence of nephrogenic systemic fibrosis in patients undergoing dialysis after contrast-enhanced magnetic resonance imaging with gadolinium-based contrast agents: the Prospective Fibrose Nephrogénique Systémique study.

    abstract:BACKGROUND:Nephrogenic systemic fibrosis (NSF) has been related to the use of gadolinium-based contrast agents (GBCAs) in patients undergoing dialysis. The Prospective Fibrose Nephrogénique Systémique study, a French prospective study supported by the French drug regulatory agency (Agence Nationale de Sécurité du Médic...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0000000000000000

    authors: Amet S,Launay-Vacher V,Clément O,Frances C,Tricotel A,Stengel B,Gauvrit JY,Grenier N,Reinhardt G,Janus N,Choukroun G,Laville M,Deray G

    更新日期:2014-02-01 00:00:00

  • Image mottle in abdominal CT.

    abstract:RATIONALE AND OBJECTIVES:To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. METHODS:Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199904000-00005

    authors: Ende JF,Huda W,Ros PR,Litwiller AL

    更新日期:1999-04-01 00:00:00

  • Ultrasound bone velocity on proximal phalanges in premenopausal, perimenopausal, and postmenopausal healthy women.

    abstract:RATIONALE AND OBJECTIVES:The authors studied premenopausal, perimenopausal, and postmenopausal women to determine if ultrasound bone velocity (UBV) on proximal phalanges of women reflect bone changes related to gonadal status and age. METHODS:A total of 166 healthy women-64 postmenopausal women (mean age 58.7 +/- 9.4 ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199701000-00011

    authors: Aguado F,Revilla M,Hernández ER,Villa LF,Rico H

    更新日期:1997-01-01 00:00:00

  • Robot-assisted biopsy using computed tomography-guidance: initial results from in vitro tests.

    abstract:PURPOSE:We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS:Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was de...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000155285.05672.cf

    authors: Kettenbach J,Kronreif G,Figl M,Fürst M,Birkfellner W,Hanel R,Ptacek W,Bergmann H

    更新日期:2005-04-01 00:00:00

  • The spectrum of sonographic findings of fibroadenoma of the breast.

    abstract::There are a number of sonographic findings seen in fibroadenoma of the breast. In a retrospective study, we examined the biopsy results of 59 masses given the sonographic diagnosis of fibroadenoma. We also reviewed the sonograms of an additional 26 biopsy-proven fibroadenomas that were not diagnosed as such with ultra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198601000-00006

    authors: Jackson VP,Rothschild PA,Kreipke DL,Mail JT,Holden RW

    更新日期:1986-01-01 00:00:00

  • The effect of verification on the assessment of imaging techniques.

    abstract::In order to measure the accuracy of a diagnostic imaging technique, the correctness of each observer decision must be determined. This is often difficult in clinical cases, and various strategies are frequently used to approximate the truth. Experiments using chest radiographs as an example are reported to show the pi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198303000-00018

    authors: Revesz G,Kundel HL,Bonitatibus M

    更新日期:1983-03-01 00:00:00

  • Sonography of the kidneys in hemolytic uremic syndrome.

    abstract::The sonographic appearance of kidneys in patients presenting with acute renal failure due to hemolytic-uremic syndrome (HUS) was evaluated and compared with that in an age-matched control series. In nine patients with HUS, the renal cortex was typically hyperechogenic and the renal pyramids appeared sonolucent. The re...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198607000-00006

    authors: Kenney PJ,Brinsko RE,Patel DV,Spitzer RE,Farrar FM

    更新日期:1986-07-01 00:00:00

  • Three-dimensional ultrashort echo time imaging of solid polymers on a 3-Tesla whole-body MRI scanner.

    abstract:OBJECTIVE:With the introduction of ultrashort echo time (UTE) sequences solid polymeric materials might become visible on clinical whole-body magnetic resonance (MR) scanners. The aim of this study was to characterize solid polymeric materials typically used for instruments in magnetic resonance guided interventions an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318188601f

    authors: Springer F,Martirosian P,Schwenzer NF,Szimtenings M,Kreisler P,Claussen CD,Schick F

    更新日期:2008-11-01 00:00:00

  • Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model.

    abstract:OBJECTIVE:We sought to evaluate the influence of tube voltage on the visualization of acute myocardial infarction (MI) in cardiac multislice spiral computed tomography (MSCT). MATERIALS AND METHODS:Acute MI was induced in 12 domestic pigs by a 45-minute balloon occlusion of the left anterior descending artery. Delayed...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000251577.68223.84

    authors: Mahnken AH,Bruners P,Mühlenbruch G,Emmerich M,Hohl C,Günther RW,Wildberger JE

    更新日期:2007-02-01 00:00:00

  • Breast stereotactic core biopsy washings: abundant cell samples from clinically occult lesions for flow cytometric DNA analysis.

    abstract:RATIONALE AND OBJECTIVES:The object of this study was to determine by flow cytometry the cellular and DNA content of the washings of core biopsy samples and needles obtained during stereotactic core biopsies of clinically occult suspicious lesions. METHODS:Fourteen-gauge core multipass biopsy inner-needle saline washi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199801000-00008

    authors: Stomper PC,Budnick RM,Stewart CC

    更新日期:1998-01-01 00:00:00

  • Multiphase magnetic resonance angiography of the abdominal and pelvic arteries: results of a bicenter multireader analysis.

    abstract:RATIONALE AND OBJECTIVES:The objective is to assess the diagnostic accuracy and interobserver variability of multiphase 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for assessment of abdominal and pelvic vascular disease. METHODS:In 41 patients from two different institutions multiphase 3D-Gd-MRA ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00004424-200201000-00005

    authors: Schoenberg SO,Essig M,Hallscheidt P,Sharafuddin MJ,Stolpen AH,Knopp MV,Yuh WT

    更新日期:2002-01-01 00:00:00

  • Acquired cystic disease of the kidneys. Computed tomography and ultrasonography appraisal in patients on peritoneal and hemodialysis.

    abstract::Screening chronic hemodialysis patients (CHD) for acquired cystic disease of the kidneys (ACDK) and its complications (hemorrhage and neoplasm) has become accepted management. We evaluated patients on CHD as well as patients on chronic peritoneal dialysis (CPD) for ACDK. The kidneys of 80 chronic dialysis patients wer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Jabour BA,Ralls PW,Tang WW,Boswell WD Jr,Colletti PM,Feinstein EI,Massry SG

    更新日期:1987-09-01 00:00:00

  • Magnetic resonance perfusion of the myocardium: semiquantitative and quantitative evaluation in comparison with coronary angiography and fractional flow reserve.

    abstract:PURPOSE:The aim of this study was to investigate if a quantitative evaluation of a magnetic resonance (MR) perfusion examination of the myocardium can achieve a comparable diagnostic accuracy as a semiquantitative evaluation. METHODS:A total of 31 patients with suspected coronary artery disease underwent MR imaging an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31824f54cb

    authors: Huber A,Sourbron S,Klauss V,Schaefer J,Bauner KU,Schweyer M,Reiser M,Rummeny E,Rieber J

    更新日期:2012-06-01 00:00:00

  • Dynamic contrast-enhanced computed tomography as a potential biomarker in patients with metastatic renal cell carcinoma: preliminary results from the Danish Renal Cancer Group Study-1.

    abstract:OBJECTIVES:The aim of this study was to explore the impact of dynamic contrast-enhanced (DCE) computer tomography (CT) as a biomarker in metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS:Twelve patients with favorable or intermediate Memorial Sloan Kettering Cancer Center risk group and clear cell mRCC par...

    journal_title:Investigative radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/RLI.0000000000000058

    authors: Mains JR,Donskov F,Pedersen EM,Madsen HH,Rasmussen F

    更新日期:2014-09-01 00:00:00

  • Cerebral computed tomography angiography using a low tube voltage (80 kVp) and a moderate concentration of iodine contrast material: a quantitative and qualitative comparison with conventional computed tomography angiography.

    abstract:OBJECTIVE:To investigate the feasibility of an 80-kVp protocol using a moderate concentration contrast material (MC-CM) for cerebral computed tomography angiography by comparison with a conventional 120-kVp protocol using a high concentration contrast material (HC-CM). MATERIALS AND METHODS:Attenuation values and sign...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31823076a4

    authors: Cho ES,Chung TS,Oh DK,Choi HS,Suh SH,Lee HK,Lee KH

    更新日期:2012-02-01 00:00:00

  • Noninvasive quantification of hepatic fat content using three-echo dixon magnetic resonance imaging with correction for T2* relaxation effects.

    abstract:OBJECTIVE:To investigate three-echo T2*-corrected Dixon magnetic resonance imaging (MRI) for noninvasively estimating hepatic fat content (HFC) compared with biopsy. MATERIALS AND METHODS:One hundred patients (50 men, 50 women; mean age, 57.7±14.2 years) underwent clinically indicated liver core biopsy (102 valid tiss...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31822b124c

    authors: Kühn JP,Evert M,Friedrich N,Kannengiesser S,Mayerle J,Thiel R,Lerch MM,Dombrowski F,Mensel B,Hosten N,Puls R

    更新日期:2011-12-01 00:00:00

  • Magnetic resonance imaging as a monitor of changes in the irradiated rat brain. An aid in determining the time course of events in a histologic study.

    abstract:RATIONALE AND OBJECTIVES:Optimal dose schedules and total dose of ionizing radiation for human central nervous system malignancy are not known. An animal model has been developed for the investigation of rat central nervous system response to proton irradiation using magnetic resonance imaging (MRI). A clinical MRI dev...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199504000-00003

    authors: Kennedy AS,Archambeau JO,Archambeau MH,Holshouser B,Thompson J,Moyers M,Hinshaw D Jr,Slater JM

    更新日期:1995-04-01 00:00:00

  • Correlation of Histological Vessel Characteristics and Diffusion-Weighted Imaging Intravoxel Incoherent Motion-Derived Parameters in Pancreatic Ductal Adenocarcinomas and Pancreatic Neuroendocrine Tumors.

    abstract:OBJECTIVE:To investigate the correlation between intravoxel incoherent motion (IVIM) model-derived parameters and histologically determined microvascularity in pancreatic ductal adenocarcinomas (PDACs) and pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:From April 2013 to May 2014, 42 patients with mal...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000187

    authors: Klau M,Mayer P,Bergmann F,Maier-Hein K,Hase J,Hackert T,Kauczor HU,Grenacher L,Stieltjes B

    更新日期:2015-11-01 00:00:00

  • The use of a thrombus-specific ultrasound contrast agent to detect thrombus in arteriovenous fistulae.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the use of a new thrombus-specific ultrasound contrast agent, MRX-408, in the ultrasonic detection of thrombus in arteriovenous (AV) fistulae. METHODS:Six purpose-bred mongrels with two AV fistulae each were imaged with gray-scale ultrasound 7 weeks after graft implantation before ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200001000-00010

    authors: Unger E,Metzger P 3rd,Krupinski E,Baker M,Hulett R,Gabaeff D,Mills J,Ihnat D,McCreery T

    更新日期:2000-01-01 00:00:00

  • Visualization of breast lymphatic pathways with an indirect computed tomography lymphography using a nonionic monometric contrast medium iopamidol: preliminary results.

    abstract:RATIONALE AND OBJECTIVES:The capability of an indirect computed tomographic lymphography (CT-LG) using a nonionic monometric contrast medium iopamidol for visualizing breast lymphatic pathways was preliminarily tested. MATERIALS AND METHODS:In 10 female dogs, a total of 0.5 and 1 mL of undiluted iopamidol was injected...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200302000-00002

    authors: Suga K,Ogasawara N,Yuan Y,Okada M,Matsunaga N,Tangoku A

    更新日期:2003-02-01 00:00:00