Abstract:
:There are a number of sonographic findings seen in fibroadenoma of the breast. In a retrospective study, we examined the biopsy results of 59 masses given the sonographic diagnosis of fibroadenoma. We also reviewed the sonograms of an additional 26 biopsy-proven fibroadenomas that were not diagnosed as such with ultrasound. The ultrasound diagnosis was correct in 50 of 76 fibroadenomas (65.8%). Only 12 of the 76 biopsy-proven fibroadenomas had the classic sonographic appearance of a smooth round or oval mass with homogeneous internal echoes. Fourteen fibroadenomas were not visible on the sonograms, even in retrospect. The remaining 50 biopsy-proven fibroadenomas demonstrated one or more "atypical" signs of border irregularity, lobulation, inhomogeneous internal echo texture, or posterior shadowing. There were nine sonographic false positives: five patients had other benign lesions on histology, and four masses believed to be sonographically compatible with fibroadenoma were found to be carcinomas. While breast sonography is frequently a useful modality for breast mass detection, particularly as an adjunct to x-ray mammography, the common overlap in characteristics of benign and malignant masses makes histologic evaluation of all solid masses essential.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Jackson VP,Rothschild PA,Kreipke DL,Mail JT,Holden RWdoi
10.1097/00004424-198601000-00006subject
Has Abstractpub_date
1986-01-01 00:00:00pages
34-40issue
1eissn
0020-9996issn
1536-0210journal_volume
21pub_type
杂志文章abstract:OBJECTIVE:BR55, a vascular endothelial growth factor receptor 2 (VEGFR2)-specific ultrasound molecular contrast agent (MCA), has shown promising results in multiple preclinical models regarding cancer imaging. In this first-in-human, phase 0, exploratory study, we investigated the feasibility and safety of the MCA for ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000362
更新日期:2017-07-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare a compressed-sensing free-breathing VIBE (fbVIBE) with a conventional breath-hold VIBE (bhVIBE) for dynamic contrast-enhanced imaging of the upper abdomen. MATERIALS AND METHODS:In total, 70 datasets (bhVIBE, n = 30; fbVIBE n = 40; hard-gated [hg] reconstruction, n = 30;...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000607
更新日期:2019-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199704000-00008
更新日期:1997-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the imaging characteristics of various iliac artery stents and stent-grafts in a multislice, computed tomography angiography (MSCTA) phantom study. METHODS:Twelve types of stents and three stent-grafts made of different materials (steel, nitinol, tantalum, cobalt-based alloy) were ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200112000-00004
更新日期:2001-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Studies describing the effects of radiographic contrast media (RCM) in leukocyte chemotaxis have been contradictory. No studies have been performed after in-vivo exposure. The authors assess the effect of RCM on leukocytes following in-vivo exposure. METHODS:Seventeen patients were studied aft...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199401000-00012
更新日期:1994-01-01 00:00:00
abstract:AIM:: We sought to improve the clinical interpretation of first-pass myocardial magnetic resonance perfusion. Parametric analyses of the myocardial distribution of the contrast agent have been proposed. The objective of the present study was to compare the effectiveness of visual analysis and of a parametric approach i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000197980.89673.4b
更新日期:2006-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the effect of the transverse ligament on translation of the menisci. METHODS:Six cadaveric knees were examined by MR imaging inside a positioning device before and after transecting the transverse ligament. The knees were examined at various positions: extension, 30 degrees of flex...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199909000-00002
更新日期:1999-09-01 00:00:00
abstract:PURPOSE:We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS:Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was de...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000155285.05672.cf
更新日期:2005-04-01 00:00:00
abstract::The large intestines of eight boxer dogs with canine histiocytic ulcerative colitis (CHUC) and 10 normal dogs were studied by in vivo angiography and postmortem microangiography. The vascular abnormalities were correlated with the gross and histologic pathology found at necropsy. The angiographic abnormalities were ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197505000-00005
更新日期:1975-05-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000099
更新日期:2015-04-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to optimize computed tomography (CT) surveillance of skeletal metastases in patients with breast cancer through the use of osseous subtraction maps between baseline and follow-up examinations created by a novel software algorithm. The new postprocessing algorithm segments the origina...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000343
更新日期:2017-02-01 00:00:00
abstract::Because of a need to correlate pulmonary microvascular changes with physiologic data during lung injury, in vitro and in vivo pulmonary capillary microangiography was performed on normal dogs and those subjected to oleic acid injury and glass bead microembolization. During these studies, no significant differences wer...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1983-01-01 00:00:00
abstract:OBJECTIVE:To assess prospectively, in healthy subjects and in patients with dilated cardiomyopathy (DCM) and hypertrophic obstructive cardiomyopathy (HOCM), the 3-dimensional (3D) shape, size, and motion of the mitral annulus (MA) using computed tomography (CT). MATERIALS AND METHODS:Twenty patients with no cardiac ab...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181994a73
更新日期:2009-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors differentiate breast lesions on sonography by measurements in two compression states that are perpendicular to each other. METHODS:Diameters of 100 breast lesions were measured preoperatively under lateromedial and craniocaudal compression with a new sonographic method. This method...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199607000-00003
更新日期:1996-07-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the impact of a novel iterative denoising and image enhancement technique in T1-weighted precontrast and postcontrast volume-interpolated breath-hold examination (VIBE) of the abdomen on image quality, noise levels, and diagnostic confidence without change of acquisit...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000746
更新日期:2020-11-18 00:00:00
abstract:OBJECTIVE:To investigate the effect of saline chase injected at 2 different rates on computed tomography (CT) angiography. MATERIALS AND METHODS:This study was approved by our institutional animal study committee. Three injection protocols were used; contrast injection (24 mL, 0.8 mL/s) without saline chase (protocol ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318032a9fe
更新日期:2007-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study was devised to develop a method of measuring the acute effects of radiocontrast media on renal function and assessing the relationship of the dose of radiocontrast media infused with the incidence of radiocontrast-induced renal failure. In addition, the drug adenosine phosphate-magne...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00004424-199406000-00004
更新日期:1994-06-01 00:00:00
abstract:OBJECTIVE:To investigate three-echo T2*-corrected Dixon magnetic resonance imaging (MRI) for noninvasively estimating hepatic fat content (HFC) compared with biopsy. MATERIALS AND METHODS:One hundred patients (50 men, 50 women; mean age, 57.7±14.2 years) underwent clinically indicated liver core biopsy (102 valid tiss...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31822b124c
更新日期:2011-12-01 00:00:00
abstract:OBJECTIVES:Intra-arterial digital subtraction angiography (IA-DSA), an invasive procedure, is the current reference examination after percutaneous transluminal angioplasty and stenting for the detection of in-stent restenosis (ISR). In this phantom study, we evaluated flat-panel angiographic computed tomography after i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318276db43
更新日期:2013-02-01 00:00:00
abstract:MATERIALS AND METHODS:Stenotic kidney (STK) and contralateral kidney magnetization transfer ratios (MTRs; Mt/M0) were measured at 3.0-T magnetic resonance imaging, at offset frequencies of 600 and 1000 Hz, before and 1 month post-PTRA in 7 RVD pigs. Stenotic kidney MTR was correlated to renal perfusion, renal blood flo...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000711
更新日期:2021-02-01 00:00:00
abstract:OBJECTIVES:To prospectively evaluate the image quality and diagnostic accuracy of magnetic resonance cholangiopancreatography (MRCP) at 3.0 T compared with that at 1.5 T used for patients. MATERIALS AND METHODS:This study was approved by our institutional review board, and informed consent was obtained from all patien...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181b4c0ae
更新日期:2009-09-01 00:00:00
abstract:BACKGROUND:Nephrogenic systemic fibrosis (NSF) has been related to the use of gadolinium-based contrast agents (GBCAs) in patients undergoing dialysis. The Prospective Fibrose Nephrogénique Systémique study, a French prospective study supported by the French drug regulatory agency (Agence Nationale de Sécurité du Médic...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/RLI.0000000000000000
更新日期:2014-02-01 00:00:00
abstract::We studied 60 male patients who had concurrent chest films (CXR), computed tomography scans (CT) and pulmonary function tests (PFT) to assess the sensitivity of CT and conventional films in detecting emphysema compared with PFT. We also sought to determine whether emphysema could be diagnosed by CT in patients with no...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198804000-00004
更新日期:1988-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The object of this study was to determine by flow cytometry the cellular and DNA content of the washings of core biopsy samples and needles obtained during stereotactic core biopsies of clinically occult suspicious lesions. METHODS:Fourteen-gauge core multipass biopsy inner-needle saline washi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199801000-00008
更新日期:1998-01-01 00:00:00
abstract::Ionic (diatrizoate, ioxaglate) and nonionic (iohexol, iosimide, iopromide, and iotrolan) contrast media (CM) were evaluated for their cytogenetic effects in lymphocytes. Heparinized blood was mixed with culture medium RPMI-1640 supplemented with phytohemagglutinin, fetal calf serum, and antibiotics. Plastic tubes cont...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198611000-00006
更新日期:1986-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Density of trabecular bone structures in human heel bones was assessed by 3D magnetic resonance (MR) gradient echo imaging (GEI) with multiple echoes. Different spatial resolutions were applied to investigate the influence of the pixel size on signal characteristics in GEI and to find suitable ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200007000-00001
更新日期:2000-07-01 00:00:00
abstract::Gelatin encapsulated nitrogen microbubbles were effective ultrasonic contrast agents in in vitro phantom and in vivo rabbit V2 carcinoma studies. Intra-arterial injection of 80-micrometer gelatin encapsulated nitrogen microbubbles appeared to improve tumor visualization by rim enhancement, which persisted for several ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198005000-00013
更新日期:1980-05-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to implement and systematically evaluate the performance of a new parameter-free segmented algorithm for analysis of diffusion imaging data using a combined intravoxel incoherent motion and diffusion kurtosis imaging (IVIM-DKI) model of spin diffusion in comparison with the simple...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000223
更新日期:2016-03-01 00:00:00
abstract::Chest radiographs are commonly obtained to assess children for bronchiolitis, both to corroborate the diagnosis and to exclude other diagnostic possibilities. Their utility in this setting has not previously been examined. Using a blinded, randomized study design, we examined the interobserver and intraobserver variat...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199102000-00004
更新日期:1991-02-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to present a deep learning approach for the automated classification of multiple sclerosis and its mimics and compare model performance with that of 2 expert neuroradiologists. MATERIALS AND METHODS:A total of 268 T2-weighted and T1-weighted brain magnetic resonance imagin scans ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000735
更新日期:2020-10-26 00:00:00