Noninvasive quantification of hepatic fat content using three-echo dixon magnetic resonance imaging with correction for T2* relaxation effects.

Abstract:

OBJECTIVE:To investigate three-echo T2*-corrected Dixon magnetic resonance imaging (MRI) for noninvasively estimating hepatic fat content (HFC) compared with biopsy. MATERIALS AND METHODS:One hundred patients (50 men, 50 women; mean age, 57.7±14.2 years) underwent clinically indicated liver core biopsy (102 valid tissue samples) and liver MRI 24 to 72 hours later. MRI was performed at 1.5T (Magnetom Avanto, Siemens Healthcare, Erlangen, Germany) using Dixon imaging with T2* correction (work in progress, WIP-432.rev.1, Siemens Healthcare). An ultrafast breath-hold three-echo 3D-gradient echo sequence with TR/TE1/TE2/TE3 of 11/2.4/4.8/9.6 milliseconds, and online calculation of T2*-corrected water images (signal intensities of water [SIW]), fat images (SIF), and fat content map (SIFAT=10×SIF/(SIW+SIF)) was used. SIs of the calculated fat content map (SIFAT) were verified using the histologically quantified HFC (HFC(path)). Spearman correlation for HFC(path) and SIFAT was calculated. Stage of fibrosis, hepatic iron content, and patterns of liver fat (macrovesicular, microvesicular, mixed) and their influence on predicting HFC by MRI were determined. RESULTS:Correlation between SIFAT and HFC(path) was rspearman=0.89. Agreement between HFC predicted by MRI and HFC(path) calculated by nonlinear saturation-growth regression was rspearman=0.89. Kruskal-Wallis analysis revealed no significant difference for SIFAT across fibrosis grades (P=0.90) and liver iron content (P=0.76). Regarding the cellular architecture of liver fat, the microvesicular pattern showed lower mean ranks in SI than macrovesicular and mixed patterns (P=0.01). CONCLUSION:T2*-corrected Dixon MRI is a noninvasive tool for estimating HFC, showing excellent correlation with liver biopsy without being limited by liver iron content and fibrosis/cirrhosis.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Kühn JP,Evert M,Friedrich N,Kannengiesser S,Mayerle J,Thiel R,Lerch MM,Dombrowski F,Mensel B,Hosten N,Puls R

doi

10.1097/RLI.0b013e31822b124c

subject

Has Abstract

pub_date

2011-12-01 00:00:00

pages

783-9

issue

12

eissn

0020-9996

issn

1536-0210

journal_volume

46

pub_type

杂志文章
  • Experimental pulmonary arteritis.

    abstract::Experimental pulmonary arteritis was produced in rabbits by intravenous injection of alveolar macrophages from donor rabbits. These animals, along with matched controls, were studied with pulmonary angiography to test the hypothesis that angiography could detect the vasculitic process in life. The animals were then sa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198007000-00005

    authors: Hicken P,Hogg JC,Pare PD

    更新日期:1980-07-01 00:00:00

  • Experimental tissue damage after subcutaneous injection of water soluble contrast media.

    abstract::Various water soluble contrast media (WSCM) were injected subcutaneously into 970 hind feet of 485 rats. Gross morphologic changes were seen after the injection and analyzed as a function of various physicochemical characteristics of WSCM. The WSCM of larger volume, higher osmolality, higher iodine content, and meglum...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199006000-00011

    authors: Kim SH,Park JH,Kim YI,Kim CW,Han MC

    更新日期:1990-06-01 00:00:00

  • Characterization of ultrasmall magnetite [correction of paramagnetic magnetite] particles as superparamagnetic contrast agents in MRI.

    abstract:RATIONALE AND OBJECTIVES:Very small dextran-coated magnetite particles were developed. These particles can be used either as immunospecific contrast agents for MRI by coupling to antibodies or as an interstitial contrast agent. METHODS:The particles were synthesized from iron chloride/dextran solutions. Size was evalu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200009000-00006

    authors: Grimm J,Karger N,Lüsse S,Winoto-Morbach S,Krisch B,Müller-Hülsbeck S,Heller M

    更新日期:2000-09-01 00:00:00

  • Semiquantitative assessment of myocardial perfusion using magnetic resonance imaging: evaluation of appropriate thresholds and segmentation models.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000133816.83192.38

    authors: Fenchel M,Kramer U,Helber U,Stauder NI,Franow A,Claussen CD,Miller S

    更新日期:2004-09-01 00:00:00

  • Incompatibility of water-soluble contrast media and intravascular pharmacologic agents. An in vitro study.

    abstract::In vitro incompatibilities between nine water-soluble contrast media and 21 intravascular pharmacologic agents were investigated using naked-eye observation and a centrifuge. Most of the previously reported incompatibilities were verified, and a few new incompatibilities were discovered: phentolamine mesylate with dia...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199201000-00008

    authors: Kim SH,Lee HK,Han MC

    更新日期:1992-01-01 00:00:00

  • Binary nature and radiographic identifiability of craniosynostosis.

    abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199410000-00005

    authors: Pilgram TK,Vannier MW,Marsh JL,Kraemer BB,Rayne SC,Gado MH,Moran CJ,McAlister WH,Shackelford GD,Hardesty RA

    更新日期:1994-10-01 00:00:00

  • Detection of emphysema with computed tomography. Correlation with pulmonary function tests and chest radiography.

    abstract::We studied 60 male patients who had concurrent chest films (CXR), computed tomography scans (CT) and pulmonary function tests (PFT) to assess the sensitivity of CT and conventional films in detecting emphysema compared with PFT. We also sought to determine whether emphysema could be diagnosed by CT in patients with no...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198804000-00004

    authors: Sanders C,Nath PH,Bailey WC

    更新日期:1988-04-01 00:00:00

  • A review of the toxicity of nonionic contrast agents in children.

    abstract:OBJECTIVES:The safety of nonionic contrast agents with that of ionic iodinated contrast agents in children is compared. METHODS:A comprehensive literature search was conducted to identify all publications on the safety profile of nonionic contrast agents administered intravenously to children. This information was com...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199311001-00027

    authors: Cohen MD

    更新日期:1993-11-01 00:00:00

  • Brain tumor enhancement in magnetic resonance imaging: dependency on the level of protein binding of applied contrast agents.

    abstract:PURPOSE:To evaluate the dependency of tumor contrast enhancement (CE) in regard to protein-binding properties of contrast agents, using 4 different agents with a wide range of protein-binding capacities in a standardized rat brain glioma model. MATERIAL AND METHODS:Sixteen rats with implanted brain gliomas were evalua...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318191a334

    authors: Wintersperger BJ,Runge VM,Tweedle MF,Jackson CB,Reiser MF

    更新日期:2009-02-01 00:00:00

  • Consistency of rotator-cuff calcifications. Observations on plain radiography, sonography, computed tomography, and at needle treatment.

    abstract:RATIONALE AND OBJECTIVES:The author analyzes findings of consistency of rotator-cuff calcifications found at ultrasound (US)-guided needle treatment compared with findings of plain radiography, US, and computed tomography (CT). METHODS:Twenty patients had rotator-cuff calcifications (mean diameter, 1.5 cm; range, 1.1-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199605000-00010

    authors: Farin PU

    更新日期:1996-05-01 00:00:00

  • Differentiation of delayed kidney graft function with gadolinium-DTPA-enhanced magnetic resonance imaging and Doppler ultrasound.

    abstract:RATIONALE AND OBJECTIVES:The authors differentiate acute tubular necrosis from transplant rejection in patients with delayed kidney graft function using gadolinium (Gd)-DTPA enhanced magnetic resonance (MR) imaging. METHODS:Twenty-four patients after renal transplantation (10 with normal graft function, 14 with delaye...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-199606000-00009

    authors: Preidler KW,Szolar D,Schreyer H,Ebner F,Kern R,Holzer H,Horina JH

    更新日期:1996-06-01 00:00:00

  • Dual source dual energy MDCT: comparison of 80 kVp and weighted average 120 kVp data for conspicuity of hypo-vascular liver metastases.

    abstract:PURPOSE:To determine whether liver metastases conspicuity is improved at 80 kVp when compared with weighted average (WA) simulated 120 kVp data using dual source dual energy CT. METHODS:A total of 11 patients with 44 hypo-vascular liver metastases underwent contrast enhanced Dual Energy CT (DECT). In all cases the sub...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181dfda78

    authors: Robinson E,Babb J,Chandarana H,Macari M

    更新日期:2010-07-01 00:00:00

  • Robot-assisted biopsy using computed tomography-guidance: initial results from in vitro tests.

    abstract:PURPOSE:We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS:Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was de...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000155285.05672.cf

    authors: Kettenbach J,Kronreif G,Figl M,Fürst M,Birkfellner W,Hanel R,Ptacek W,Bergmann H

    更新日期:2005-04-01 00:00:00

  • Feasibility of 3T dynamic contrast-enhanced magnetic resonance-guided biopsy in localizing local recurrence of prostate cancer after external beam radiation therapy.

    abstract:OBJECTIVES:The objective of this study was to assess the feasibility of the combination of magnetic resonance (MR)-guided biopsy (MRGB) and diagnostic 3T MR imaging in the localization of local recurrence of prostate cancer (PCa) after external beam radiation therapy (EBRT). MATERIALS AND METHODS:Twenty-four consecuti...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181c7bcda

    authors: Yakar D,Hambrock T,Huisman H,Hulsbergen-van de Kaa CA,van Lin E,Vergunst H,Hoeks CM,van Oort IM,Witjes JA,Barentsz JO,Fütterer JJ

    更新日期:2010-03-01 00:00:00

  • Radiologist's responsibility in France when using contrast media.

    abstract::French physicians must obtain their patient's consent before carrying out an action that interferes with the patient's corporal integrity. The doctor must use simple, approximate, intelligent, and honest words that help the patient to reach the indispensable decision. Proof of lack of consent lies with the patient. Th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00006

    authors: Alméras JP,Husson R,Moreau JF

    更新日期:1988-09-01 00:00:00

  • Structured Reporting of Rectal Magnetic Resonance Imaging in Suspected Primary Rectal Cancer: Potential Benefits for Surgical Planning and Interdisciplinary Communication.

    abstract:OBJECTIVES:The aim of this study was to evaluate the effect of structured reports (SRs) in comparison to nonstructured, free-text (FT) rectal magnetic resonance imaging (MRI) reports in patients with histologically proven rectal cancer and potential effects of both types of reporting on referring surgeons' satisfaction...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000336

    authors: Nörenberg D,Sommer WH,Thasler W,DʼHaese J,Rentsch M,Kolben T,Schreyer A,Rist C,Reiser M,Armbruster M

    更新日期:2017-04-01 00:00:00

  • Clinical and High-Resolution CT Features of the COVID-19 Infection: Comparison of the Initial and Follow-up Changes.

    abstract:OBJECTIVES:In late December 2019, an outbreak of coronavirus disease (COVID-19) in Wuhan, China was caused by a novel coronavirus, newly named severe acute respiratory syndrome coronavirus 2. We aimed to quantify the severity of COVID-19 infection on high-resolution chest computed tomography (CT) and to determine its r...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000674

    authors: Xiong Y,Sun D,Liu Y,Fan Y,Zhao L,Li X,Zhu W

    更新日期:2020-06-01 00:00:00

  • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

    abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200207000-00005

    authors: Ropers D,Regenfus M,Stilianakis N,Birke S,Kessler W,Moshage W,Laub G,Daniel WG,Achenbach S

    更新日期:2002-07-01 00:00:00

  • Time continuous tracking and segmentation of cardiovascular magnetic resonance images using multidimensional dynamic programming.

    abstract::In this article, we propose a semiautomatic method for time-continuous contour detection in all phases of the cardiac cycle in magnetic resonance sequences. The method is based on multidimensional dynamic programming. After shape parameterization, cost hypercubes are filled with image-feature derived cost function val...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000194070.88432.24

    authors: Uzümcü M,van der Geest RJ,Swingen C,Reiber JH,Lelieveldt BP

    更新日期:2006-01-01 00:00:00

  • The retropsoas recess. Demonstration using computed tomography.

    abstract::The retropsoas recess, a previously undescribed normal anatomic variant, is reported. In most individuals, the space posterior to the belly of the psoas muscle contains fat within the posterior pararenal space. However, a retrospective review of 250 consecutive CT examinations of the abdomen revealed 11 cases (4.4%) i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198707000-00004

    authors: Kelly RB,Mahoney PD,Frick MP

    更新日期:1987-07-01 00:00:00

  • A Single-Arm, Multicenter Validation Study of Prostate Cancer Localization and Aggressiveness With a Quantitative Multiparametric Magnetic Resonance Imaging Approach.

    abstract:OBJECTIVES:The aims of this study were to assess the discriminative performance of quantitative multiparametric magnetic resonance imaging (mpMRI) between prostate cancer and noncancer tissues and between tumor grade groups (GGs) in a multicenter, single-vendor study, and to investigate to what extent site-specific dif...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/RLI.0000000000000558

    authors: Maas MC,Litjens GJS,Wright AJ,Attenberger UI,Haider MA,Helbich TH,Kiefer B,Macura KJ,Margolis DJA,Padhani AR,Selnæs KM,Villeirs GM,Fütterer JJ,Scheenen TWJ

    更新日期:2019-07-01 00:00:00

  • Osteosarcoma of the nude rat. A model for experimental magnetic resonance imaging studies of bone tumors.

    abstract::A 144cerium-induced osteosarcoma was transplanted to athymic nude rats (Han:rnu/rnu). Nineteen of the tumor-bearing animals were used to demonstrate the characteristics of the osteosarcoma on magnetic resonance imaging (MRI) in comparison with a group of nine animals that had not received any tumor transplant. The tum...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Witzel JG,Bohndorf K,Prescher A,Adam G

    更新日期:1992-03-01 00:00:00

  • Continuous Hepatic Arterial Multiphase Magnetic Resonance Imaging During Free-Breathing.

    abstract:PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a convention...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000459

    authors: Weiss J,Notohamiprodjo M,Taron J,Martirosian P,Nickel D,Bamberg F,Nikolaou K,Othman AE

    更新日期:2018-10-01 00:00:00

  • Microangiographic anatomy of the cat's eye.

    abstract::The microangiographic anatomy of the cat's eye is presented. The characteristic vascular pattern of each of the three distinct circulations, retinal choroidal, and ciliary is described and illustrated. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197501000-00007

    authors: Rothman SL,Kier EL,Deuker DK

    更新日期:1975-01-01 00:00:00

  • Phase I clinical evaluation of citrate-coated monocrystalline very small superparamagnetic iron oxide particles as a new contrast medium for magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the safety and pharmacokinetics of a newly developed MR contrast medium consisting of very small superparamagnetic iron oxide particles (VSOP) coated with citrate (VSOP-C184) in a clinical phase I trial. METHODS:A total of 18 healthy subjects received either VSOP-C184 (core diamete...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/01.rli.0000129472.45832.b0

    authors: Taupitz M,Wagner S,Schnorr J,Kravec I,Pilgrimm H,Bergmann-Fritsch H,Hamm B

    更新日期:2004-07-01 00:00:00

  • Terbutaline in diagnosis of interstitial fallopian tube obstruction.

    abstract::Effectiveness of terbutaline, a potent uterine muscle relaxant, for differentiation of temporary and anatomic interstitial fallopian tube obstruction (IFTO) at hysterosalpingography (HSG) was explored. In 43 IFTO evaluated, HSG after terbutaline showed patency in only one of 16 tubes in which IFTO was caused by spasm ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198803000-00010

    authors: Thurmond AS,Novy M,Rösch J

    更新日期:1988-03-01 00:00:00

  • Microbubble contrast agents: targeted ultrasound imaging and ultrasound-assisted drug-delivery applications.

    abstract::The use of microbubble contrast agents for general tissue delineation and perfusion enjoys steady interest in ultrasound imaging. Microbubbles as contrast materials require a small dosage and show excellent detection sensitivity. Targeting ligands on the surface of microbubbles permit the selective accumulation of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/01.rli.0000199292.88189.0f

    authors: Klibanov AL

    更新日期:2006-03-01 00:00:00

  • Magnetic resonance imaging of pulmonary ventilation. Initial experiences with a gadolinium-DTPA-based aerosol.

    abstract:RATIONALE AND OBJECTIVES:The authors investigate whether a modified gadolinium (Gd)-DTPA formulation can be aerosolized and used as a contrast agent for magnetic resonance (MR) ventilation imaging of the lungs. METHODS:Gadolinium-DTPA (gadopentetate dimeglumine, Schering AG, Berlin, Germany, 100 mmol Gd/L) was modifie...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199712000-00010

    authors: Misselwitz B,Mühler A,Heinzelmann I,Böck JC,Weinmann HJ

    更新日期:1997-12-01 00:00:00

  • Personal computer needs for the radiologist.

    abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00015

    authors: Newell JD,Hunter TB

    更新日期:1986-02-01 00:00:00

  • Adenosine-stress dynamic myocardial CT perfusion imaging: initial clinical experience.

    abstract:OBJECTIVE:To evaluate the feasibility of adenosine-stress dynamic myocardial volume perfusion imaging with second generation dual source computed tomography (CT) for the qualitative and quantitative assessment of myocardial blood flow (MBF) compared with stress perfusion and viability magnetic resonance imaging (MRI). ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181dfa2f2

    authors: Bastarrika G,Ramos-Duran L,Rosenblum MA,Kang DK,Rowe GW,Schoepf UJ

    更新日期:2010-06-01 00:00:00