Abstract:
:Effectiveness of terbutaline, a potent uterine muscle relaxant, for differentiation of temporary and anatomic interstitial fallopian tube obstruction (IFTO) at hysterosalpingography (HSG) was explored. In 43 IFTO evaluated, HSG after terbutaline showed patency in only one of 16 tubes in which IFTO was caused by spasm or other temporary cause. We conclude that terbutaline is not helpful in differentiating temporary from anatomic tubal obstruction during HSG.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Thurmond AS,Novy M,Rösch Jdoi
10.1097/00004424-198803000-00010subject
Has Abstractpub_date
1988-03-01 00:00:00pages
209-10issue
3eissn
0020-9996issn
1536-0210journal_volume
23pub_type
杂志文章abstract::An agent has been identified in lymph from rat kidneys rendered ischemic by partial renal artery occlusion that induces a striking neovascular response in a hamster cheek-pouch assay system. The factor has a high molecular weight, cannot be identified in lymph from normal kidneys, and is associated with a marked incre...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198501000-00015
更新日期:1985-01-01 00:00:00
abstract::Methods are presented for the quantification of spatial resolution in x-ray computed tomographic (CT) images. Model-dependent methods are derived and compared with model independent methods for computation of the Modulation Transfer Function (MTF). These techniques are applied to phantom images of point, line, edge, a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198603000-00012
更新日期:1986-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The clinically most widely used devices (Porstmann-plug, Rashkind-umbrella, Botallooccluder) have inherent specific limitations (eg, transarterial approach, residual shunts, limited retrieval). The authors assess practicability, efficacy, and tissue reaction of the new retrievable transvenous p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199709000-00004
更新日期:1997-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors determine the relative effect of soft-tissue compartments, body fat (percent [%Bfat] and weight [Bfat kg]) and fat-free mass (FFM kg), on measurements of ultrasound bone velocity (UBV m/second). METHODS:The authors measured UBV in proximal phalanxes and body fat and fat-free mass b...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199710000-00005
更新日期:1997-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVE:The purpose of this study was to investigate the feasibility, efficacy, and safety of ultrasound-guided percutaneous cryotherapy of stage T1 breast cancers. MATERIALS AND METHODS:Thirty patients with biopsy-confirmed breast cancers with tumor diameters of 15 mm or smaller (range, 5-15 mm; media...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000166935.56971.ff
更新日期:2005-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors investigated whether gadolinium-ethoxybenzyl-DTPA (Gd-EOB-DTPA) can be eliminated in the absence of the two usual excretory pathways (urinary or biliary) and whether a remaining excretory pathway is able to compensate for impaired liver or kidney function. METHODS:The study was per...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199402000-00017
更新日期:1994-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the imaging characteristics of various iliac artery stents and stent-grafts in a multislice, computed tomography angiography (MSCTA) phantom study. METHODS:Twelve types of stents and three stent-grafts made of different materials (steel, nitinol, tantalum, cobalt-based alloy) were ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200112000-00004
更新日期:2001-12-01 00:00:00
abstract::Sixteen observers averaging 7.4 years experience in interpreting radiology images and 16 observers without radiology training were tested for their ability to detect low-contrast signals in structured noise backgrounds using a digital display system. No significant difference in true positives, false positives, time t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198704000-00006
更新日期:1987-04-01 00:00:00
abstract:OBJECTIVE:To evaluate the feasibility of adenosine-stress dynamic myocardial volume perfusion imaging with second generation dual source computed tomography (CT) for the qualitative and quantitative assessment of myocardial blood flow (MBF) compared with stress perfusion and viability magnetic resonance imaging (MRI). ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181dfa2f2
更新日期:2010-06-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare technical aspects and neointima formation of a new Nitinol stent and a Wallstent. METHODS:A Nitinol sten and a Wallstent were placed into the iliac arteries of 14 sheep (total of 28 stents) and followed angiographically. Seven sheep were killed after 1 month and 7 after 4.5 months. ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199507000-00004
更新日期:1995-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Gd-DTPA is a well-characterized, safe contrast agent frequently used in magnetic resonance imaging (MRI) of the central nervous system. The purpose of this double-blind, comparative MRI study of brain, spine, trunk, and limbs was to evaluate the safety and efficacy of Gd-DOTA versus Gd-DTPA in ...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00004424-199502000-00002
更新日期:1995-02-01 00:00:00
abstract::Magnetic resonance spectroscopy (MRS) has been most extensively applied to the study of animal models and not humans. The major reason for this extensive animal research is due to the nature of the early magnetic resonance high-field magnets, which only permitted the study of isolated cells, tissues, or small animals....
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-198912000-00004
更新日期:1989-12-01 00:00:00
abstract:OBJECTIVES:Magnetic resonance imaging guidance has been sporadically reported for renal tumor cryoablation (CA); therefore, clinical experience with this modality is still limited.The aim of this study is to retrospectively analyze our 10-year experience with renal tumor CA performed on a 1.5 T magnetic resonance imagi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000719
更新日期:2020-09-04 00:00:00
abstract:RATIONALE AND OBJECTIVES:Validation of new positron emission tomography (PET) tracers or magnetic (MR) imaging contrast agents is based on isolated rodent heart preparations. The use of larger animals could provide a more direct validation using the devices used for humans. METHODS:An isolated pig heart preparation ha...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199711000-00010
更新日期:1997-11-01 00:00:00
abstract::Arterial occlusion by direct-current transcatheter electrocoagulation (TCEC) has been developed experimentally and used successfully in clinical situations. The major shortcoming of the technique has been the lengthy time necessary for occlusion of larger arteries. In the present study we attempted to decrease the tim...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198203000-00011
更新日期:1982-03-01 00:00:00
abstract:OBJECTIVES:Imaging of the kidney using blood oxygen level dependent MR presents a major opportunity to examine differences in tissue oxygenation within the cortex and medulla applicable to human disease. We sought to define the differences between regions within kidneys and to optimize selection of regions of interest ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181b4c1e8
更新日期:2009-09-01 00:00:00
abstract::Comparatively new in the roentgen evaluation of infants and children, xerography would appear to be ideal for portraying the pediatric airway. Since the radiation dose of xerography is higher than conventional radiography, its image quality is the subject of careful scrutiny in a pediatric setting here described in 23...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197807000-00002
更新日期:1978-07-01 00:00:00
abstract:OBJECTIVES:Ferumoxytol, an intravenous iron supplement, can be used in off-label mode as a contrast agent in magnetic resonance imaging. The aim of this study was to assess whether ferumoxytol can be used as a marker of inflammation in animal models of acute and chronic inflammatory kidney diseases. MATERIAL AND METHO...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000209
更新日期:2016-02-01 00:00:00
abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199105000-00009
更新日期:1991-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199704000-00008
更新日期:1997-04-01 00:00:00
abstract::Surgical resection is the standard of care for colorectal metastases isolated to the liver. However, only 10-25% of the patients are eligible for resection because of extent and location of the disease in the liver or concurrent medical conditions. Image-guided radiofrequency (RF) ablation is a minimally invasive tech...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-200411000-00007
更新日期:2004-11-01 00:00:00
abstract::Because of relatively low acute toxicity, iosulamide meglumine has been recommended as an improved contrast material for intravenous cholangiography. It has been postulated that high doses of the compound could be given safely with the expectation of achieving greater biliary excretion and improved opacification of th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198105000-00016
更新日期:1981-05-01 00:00:00
abstract::The effects of edge gradient and blur on the detection pulmonary nodules were studied, using a test series of 175 artificial nodules on 30 chest films. The nodules were of homogeneous texture, about 1 cm in diameter and had a mean contrast of .12. Six observers viewed the film set, scoring both location and confidence...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197901000-00004
更新日期:1979-01-01 00:00:00
abstract::The developing trend for all medical images to be in digital form raises an important question: should diagnostic interpretations be made directly from a CRT or from some form of hard copy recording of the CRT? This question was studied by having two observers read a series of digital images of the thyroid including b...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198305000-00015
更新日期:1983-05-01 00:00:00
abstract::Three facets of dual-energy quantitative computed tomography are studied: (1) the algorithm for postprocessing data (the methods of Cann, Laval-Jeantet et al, Goodsitt et al [two methods], and Nickoloff et al); (2) the influence of choice of tissue-equivalent materials for calibration; and (3) the difference between c...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199008000-00003
更新日期:1990-08-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a convention...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000459
更新日期:2018-10-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate if pancreatic steatosis measured by proton density fat fraction (PDFF) is associated with exocrine pancreatic function defined by fecal elastase concentrations. MATERIALS AND METHODS:A total of 1458 volunteers (777 women; age range, 21-88 years) underwent magnetic re...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000554
更新日期:2019-07-01 00:00:00
abstract::Patients with intracranial arteriovenous malformations (AVM) can expect significant mortality (15% to 20%) and morbidity (20% to 30%) over a 15-year to 20-year period. Recent advances in interventional neuroradiology, neurosurgery, neuroanesthesia, and stereotactic radiotherapy provide the opportunity to obliterate ma...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199008000-00014
更新日期:1990-08-01 00:00:00
abstract:PURPOSE:The aim of this study was to determine to what degree current compressed sensing methods are capable of accelerating clinical magnetic resonance neuroimaging sequences. METHODS:Two 2-dimensional clinical sequences were chosen for this study because of their long scan times. A pilot study was used to establish ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31828a012d
更新日期:2013-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Magnetic resonance microscopy (MRM) has evolved from a technical curiosity to a tool with which researchers can study important disease models. But MRM is not simply an extension of clinical magnetic resonance imaging. In this article, the unique adaptations of MRM required in the study of caro...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199409000-00004
更新日期:1994-09-01 00:00:00