Can Ferumoxytol be Used as a Contrast Agent to Differentiate Between Acute and Chronic Inflammatory Kidney Disease?: Feasibility Study in a Rat Model.

Abstract:

OBJECTIVES:Ferumoxytol, an intravenous iron supplement, can be used in off-label mode as a contrast agent in magnetic resonance imaging. The aim of this study was to assess whether ferumoxytol can be used as a marker of inflammation in animal models of acute and chronic inflammatory kidney diseases. MATERIAL AND METHODS:The institutional animal care committee approved this study. A total of 18 rats were examined: 6 healthy Sprague Dawley rats as a control group; 6 rats with polycystic kidney disease (PKD) as a model for chronic inflammatory disease; Thy-1, an antibody triggering glomerulonephritis, was injected in 6 rats as a model for acute inflammation. Each rat was examined directly before and 24 hours after intravenous administration of ferumoxytol at a dose of 30 mg Fe/kg body weight. T2* times of renal tissue were approximated using a multiecho sequence. Changes in relative T2* times and T2 signal intensity after ferumoxytol injection were calculated. RESULTS:Statistically significant differences between the 3 groups were found: the T2* times of both, Thy-1 and PKD rats were statistically significant different compared with the control group (T2* time ratio after/before: Thy-1, 0.21; PKD, 0.19, control, 0.28; P = 0.002). The highest T2 signal loss in the renal cortex was observed in the Thy-1 rats (T2 signal intensity ratio after/before: Thy-1, 0.49; PKD, 0.79; control, 0.78; P = 0.0005). CONCLUSIONS:Ferumoxytol-enhanced magnetic resonance imaging allows detection and differentiation of acute and chronic inflammatory kidney disease based on different patterns of parenchymal ferumoxytol depositions. Ferumoxytol thus might help to differentiate between different types of inflammation in various kidney diseases.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Budjan J,Neudecker S,Schock-Kusch D,Kraenzlin B,Schoenberg SO,Michaely HJ,Attenberger UI

doi

10.1097/RLI.0000000000000209

subject

Has Abstract

pub_date

2016-02-01 00:00:00

pages

100-5

issue

2

eissn

0020-9996

issn

1536-0210

journal_volume

51

pub_type

杂志文章
  • Multiphase magnetic resonance angiography of the abdominal and pelvic arteries: results of a bicenter multireader analysis.

    abstract:RATIONALE AND OBJECTIVES:The objective is to assess the diagnostic accuracy and interobserver variability of multiphase 3D gadolinium-enhanced magnetic resonance angiography (3D-Gd-MRA) for assessment of abdominal and pelvic vascular disease. METHODS:In 41 patients from two different institutions multiphase 3D-Gd-MRA ...

    journal_title:Investigative radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1097/00004424-200201000-00005

    authors: Schoenberg SO,Essig M,Hallscheidt P,Sharafuddin MJ,Stolpen AH,Knopp MV,Yuh WT

    更新日期:2002-01-01 00:00:00

  • Semiautomatic lymph node segmentation in multislice computed tomography: impact of slice thickness on segmentation quality, measurement precision, and interobserver variability.

    abstract:OBJECTIVES:To determine the impact of slice thickness on semiautomatic lymph node analysis. MATERIALS AND METHODS:Thoracic multislice computed tomography (MSCT) of 46 patients with NSCLC were reconstructed at 1.0-, 3.0-, and 5.0-mm slice thickness. Two radiologists independently determined long and short axis diameter...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181c443e1

    authors: Buerke B,Puesken M,Beyer F,Gerss J,Weckesser M,Seifarth H,Heindel W,Wessling J

    更新日期:2010-02-01 00:00:00

  • Transverse ligament and its effect on meniscal motion. Correlation of kinematic MR imaging and anatomic sections.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the effect of the transverse ligament on translation of the menisci. METHODS:Six cadaveric knees were examined by MR imaging inside a positioning device before and after transecting the transverse ligament. The knees were examined at various positions: extension, 30 degrees of flex...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199909000-00002

    authors: Muhle C,Thompson WO,Sciulli R,Pedowitz R,Ahn JM,Yeh L,Clopton P,Haghighi P,Trudell DJ,Resnick D

    更新日期:1999-09-01 00:00:00

  • Binary nature and radiographic identifiability of craniosynostosis.

    abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199410000-00005

    authors: Pilgram TK,Vannier MW,Marsh JL,Kraemer BB,Rayne SC,Gado MH,Moran CJ,McAlister WH,Shackelford GD,Hardesty RA

    更新日期:1994-10-01 00:00:00

  • Myocardial wall motion evaluation using amplitude frequency spectral analysis.

    abstract::Frequency spectral analysis of cardiac wall motion as calculated from the recorded video kymogram are demonstrated. Characteristic harmonics following the fundamental frequency of the cardiac rate have been demonstrated to have an alternating sequential energy distribution as measured from the free margin of the left ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197503000-00005

    authors: Silverman NR,Rosen L,Helland DR

    更新日期:1975-03-01 00:00:00

  • Evaluation of radiologist interpretive performance using blinded reads by multiple external readers.

    abstract:OBJECTIVE:To demonstrate a method of assessing radiologic diagnostic agreement utilizing multiple blinded external readers. METHODS:Six body CT studies interpreted by one reader (primary reader) at the host institution were compiled with patient identifiers removed. Brief clinical histories that were available to the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181d2ee97

    authors: Ryan AF,Semelka RC,Molina PL,Yonkers S,Vaidean G

    更新日期:2010-04-01 00:00:00

  • Pancreatic Steatosis Is Associated With Impaired Exocrine Pancreatic Function.

    abstract:OBJECTIVES:The aim of this study was to investigate if pancreatic steatosis measured by proton density fat fraction (PDFF) is associated with exocrine pancreatic function defined by fecal elastase concentrations. MATERIALS AND METHODS:A total of 1458 volunteers (777 women; age range, 21-88 years) underwent magnetic re...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000554

    authors: Kromrey ML,Friedrich N,Hoffmann RT,Bülow R,Völzke H,Weiss FU,Lerch MM,Motosugi U,Kühn JP

    更新日期:2019-07-01 00:00:00

  • Dechelation (Transmetalation): Consequences and Safety Concerns With the Linear Gadolinium-Based Contrast Agents, In View of Recent Health Care Rulings by the EMA (Europe), FDA (United States), and PMDA (Japan).

    abstract::The issue of dechelation (transmetallation) in vivo after administration of the linear gadolinium-based contrast agents, and potential safety concerns, is considered on the basis of an extensive, focused literature review. Early indications of potential problems included the high level of excess ligand used in the for...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000507

    authors: Runge VM

    更新日期:2018-10-01 00:00:00

  • Depiction of reperfused myocardial infarction using contrast-enhanced spin echo and gradient echo magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:The authors used gadolinium (Gd) chelate as a T1, T2, and T2* enhancing agent in reperfused myocardial infarction to compare the appearance of reperfused myocardial infarction on spin echo and gradient echo magnetic resonance (MR) sequences. METHODS:Rats (n = 28) were subjected to reperfused m...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199807000-00002

    authors: Geschwind JF,Saeed M,Wendland MF,Higgins CB

    更新日期:1998-07-01 00:00:00

  • Robot-assisted biopsy using computed tomography-guidance: initial results from in vitro tests.

    abstract:PURPOSE:We sought to develop a robotic system for computed tomography (CT)-guided biopsy to validate the feasibility, accuracy, and efficacy of the system using phantom tests. MATERIALS AND METHODS:Ten peas (mean diameter 9.9+/-0.4 mm) embedded within a gel phantom were selected for biopsy. Once the best access was de...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000155285.05672.cf

    authors: Kettenbach J,Kronreif G,Figl M,Fürst M,Birkfellner W,Hanel R,Ptacek W,Bergmann H

    更新日期:2005-04-01 00:00:00

  • Analysis of edge-tracking errors inherent in fluoroscopic images of the beating heart.

    abstract:RATIONALE AND OBJECTIVES:Because of the complex relationships between the dynamic three-dimensional cardiac surface shape and its projected image, errors arise with the use of two-dimensional silhouettes to measure displacements of the heart. The character and frequency of such errors are examined. METHODS:A high-prec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199403000-00004

    authors: McInerney JJ,Weldner PW,Herr MD,Copenhaver GL

    更新日期:1994-03-01 00:00:00

  • Application of direct cannulation and injection lymphangiography to the study of the canine cardiac and pulmonary efferent mediastinal lymphatics.

    abstract::Lymphangiograms of canine cardiac and pulmonary efferent mediastinal lymphatics were made by cannulation and injection of Ethiodol. Injections were made singly and serially. The mediastinal lymphatics and lymph nodes, which constitute the pathways of drainage of the heart and lungs, were delineated from the point of c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197901000-00012

    authors: Leeds SE,Uhley HN,Meister RB

    更新日期:1979-01-01 00:00:00

  • Fluorinated blood substitute retention in the rat measured by fluorine-19 magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:Emulsions of perfluorocarbons (PFCs) have been tested as blood substitutes. However, evidence exists that there is long-term retention of some PFCs by the organs of the reticuloendothelial system (RES). The authors investigate organ retention of the blood substitute component, perfluorotripropy...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199208000-00012

    authors: Meyer KL,Carvlin MJ,Mukherji B,Sloviter HA,Joseph PM

    更新日期:1992-08-01 00:00:00

  • Magnetic resonance evaluation of regional left ventricular function. Effect of through-plane motion.

    abstract:RATIONALE AND OBJECTIVES:Measurements of segmental contraction of the left ventricle by standard magnetic resonance imaging (MRI) and two-dimensional echocardiography involve the comparison of diastolic and systolic time frames acquired from the same imaging plane in space. As the cone-shaped left ventricle shortens al...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199209000-00004

    authors: Pattynama PM,Doornbos J,Hermans J,van der Wall EE,de Roos A

    更新日期:1992-09-01 00:00:00

  • Selective catheterization for magnification angiography of internal spermatic and proper hepatic arteries in rabbits.

    abstract::A method is presented for selective catheterization and filming of the small internal spermatic and proper hepatic arteries in rabbits. The angiograms thus obtained afford clear delineation of the vessels and their branches and can enhance radiographic investigation of a variety of experimental disease models. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197705000-00009

    authors: Young S,Hollenberg NK

    更新日期:1977-05-01 00:00:00

  • Evaluation and validation of ureteric jet index by glomerular filtration rate.

    abstract:RATIONALE AND OBJECTIVES:Ureteric jet index (UJI), a newly developed technique derived from color Doppler ultrasonography, may hold promise in evaluating renal function because of its ability to evaluate individual renal function and the use of nonionizing radiation. To assess the usefulness of UJI, the authors in this...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199908000-00001

    authors: Chiu NT,Wu CC,Yao WJ,Tu DG,Lee BF,Tong YC,Pan CC

    更新日期:1999-08-01 00:00:00

  • Tubal sterilization by selective catheterization in an animal model.

    abstract:RATIONAL AND OBJECTIVES:The feasibility of tubal occlusion by selective salpingography was tested in an animal model; three novel occluding materials also were tested for this application. METHODS:Unilateral selective salpingography was performed in three groups of six rabbits; fallopian tubes were embolized with etha...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199402000-00007

    authors: Maubon A,Rouanet JP,Laurent A,Joujoux JM,Cover S,Courtieu C,Wassef M,Godlewski G,Honiger J,Lopez FM

    更新日期:1994-02-01 00:00:00

  • Effect of additional cations on the twitching reaction to intracarotid, nonionic contrast media in rabbits.

    abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199009000-00010

    authors: Whisson CC,Evill CA,Sage MR,Wilson AJ

    更新日期:1990-09-01 00:00:00

  • Patient choice and nonionic contrast media.

    abstract:RATIONALE AND OBJECTIVES:Because of the greatly increased cost of nonionic, low-osmolar contrast material, some practitioners reserve its use for patients at high risk for an adverse contrast reaction. The authors attempt to evaluate the proportion of low-risk outpatients--when offered a choice between the more expensi...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199304000-00008

    authors: Hopper KD,Matthews YL

    更新日期:1993-04-01 00:00:00

  • Incidence of nephrogenic systemic fibrosis in patients undergoing dialysis after contrast-enhanced magnetic resonance imaging with gadolinium-based contrast agents: the Prospective Fibrose Nephrogénique Systémique study.

    abstract:BACKGROUND:Nephrogenic systemic fibrosis (NSF) has been related to the use of gadolinium-based contrast agents (GBCAs) in patients undergoing dialysis. The Prospective Fibrose Nephrogénique Systémique study, a French prospective study supported by the French drug regulatory agency (Agence Nationale de Sécurité du Médic...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0000000000000000

    authors: Amet S,Launay-Vacher V,Clément O,Frances C,Tricotel A,Stengel B,Gauvrit JY,Grenier N,Reinhardt G,Janus N,Choukroun G,Laville M,Deray G

    更新日期:2014-02-01 00:00:00

  • Alteration of human tumor cell adhesion by high-strength static magnetic fields.

    abstract:RATIONALE AND OBJECTIVES:The authors investigated whether the ability of human malignant melanoma cells to increase in cell number or their ability to remain viable was compromised by high-field strength static magnetic fields. Normal human fibroblasts also were studied to determine if any magnetic field-related altera...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00014

    authors: Short WO,Goodwill L,Taylor CW,Job C,Arthur ME,Cress AE

    更新日期:1992-10-01 00:00:00

  • Polycystic kidney disease evaluation by magnetic resonance imaging in ischemia-reperfusion injured PKD1 knockout mouse model: comparison of T2-weighted FSE and true-FISP.

    abstract:OBJECTIVE:To investigate the efficacy of true fast imaging with steady state precession (true-FISP) compared with T2-weighted fast spin echo (T2W-FSE) in monitoring changes in cyst volume and renal expansion in an ischemia reperfusion (IR) injured PKD1 knockout (IKO) mouse model. MATERIALS AND METHODS:The animal study...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181be3501

    authors: Zhou X,Bao H,Takakura A,Zhou J,Albert M,Sun Y

    更新日期:2010-01-01 00:00:00

  • Assessment of preoperative magnetic resonance imaging staging in patients with hepatocellular carcinoma undergoing resection compared with the seventh American Joint Committee on Cancer System.

    abstract:OBJECTIVES:The aim of this study was to compare the prognostic utility of a staging system using magnetic resonance imaging (MRI) with the seventh American Joint Committee on Cancer (AJCC) staging system in patients with hepatocellular carcinoma (HCC) who underwent hepatic resection. MATERIALS AND METHODS:A total of 1...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182630e8d

    authors: An C,Choi GH,Lee HS,Kim MJ

    更新日期:2012-11-01 00:00:00

  • Saturation kinetics of iopanoate in dogs with an intact enterohepatic circulation. Before and after phenobarbital induction.

    abstract::Capacity-limited elimination of sodium iopanoate and a reproducible apparent transport maximum (Tm) were demonstrated in nonoperated dogs having an intact enterohepatic circulation and normal endogenous bile salt pool. Using a multiple infusion technique, estimation of apparent Tm of iopanoate in the liver was possibl...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197601000-00007

    authors: Herzog RJ,Nelson JA,Staubus AE

    更新日期:1976-01-01 00:00:00

  • Heavily Calcified Coronary Arteries: Advanced Calcium Subtraction Improves Luminal Visualization and Diagnostic Confidence in Dual-Energy Coronary Computed Tomography Angiography.

    abstract:OBJECTIVES:The aim of this study was to evaluate a prototype dual-energy computed tomography calcium subtraction algorithm and its impact on luminal visualization in patients with heavily calcified coronary arteries. MATERIALS AND METHODS:Twenty-nine patients (62% male; mean age, 64 ± 7 years) who had undergone dual-e...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000416

    authors: De Santis D,Jin KN,Schoepf UJ,Grant KL,De Cecco CN,Nance JW Jr,Vogl TJ,Laghi A,Albrecht MH

    更新日期:2018-02-01 00:00:00

  • First-in-Human Ultrasound Molecular Imaging With a VEGFR2-Specific Ultrasound Molecular Contrast Agent (BR55) in Prostate Cancer: A Safety and Feasibility Pilot Study.

    abstract:OBJECTIVE:BR55, a vascular endothelial growth factor receptor 2 (VEGFR2)-specific ultrasound molecular contrast agent (MCA), has shown promising results in multiple preclinical models regarding cancer imaging. In this first-in-human, phase 0, exploratory study, we investigated the feasibility and safety of the MCA for ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000362

    authors: Smeenge M,Tranquart F,Mannaerts CK,de Reijke TM,van de Vijver MJ,Laguna MP,Pochon S,de la Rosette JJMCH,Wijkstra H

    更新日期:2017-07-01 00:00:00

  • Thirty-two-channel coil 3T magnetic resonance-guided biopsies of prostate tumor suspicious regions identified on multimodality 3T magnetic resonance imaging: technique and feasibility.

    abstract:OBJECTIVES:To test the technique and feasibility of translating tumor suspicious region maps in the prostate, obtained by multimodality, anatomic, and functional 3T magnetic resonance imaging (MRI) data to 32-channel coil, T2-weighted (T2-w), 3T MR images, for directing MR-guided biopsies. Furthermore, to evaluate the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31817d0506

    authors: Hambrock T,Fütterer JJ,Huisman HJ,Hulsbergen-vandeKaa C,van Basten JP,van Oort I,Witjes JA,Barentsz JO

    更新日期:2008-10-01 00:00:00

  • Technical feasibility and performance studies of a 0.009-inch nitinol microguidewire for potential neuroendovascular applications.

    abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199704000-00008

    authors: Putman CM,Chaloupka JC,Kailasnath P,Alderman J

    更新日期:1997-04-01 00:00:00

  • Magnetic resonance imaging and histologic findings of experimental cerebral fat embolism.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study was to determine whether cerebral fat embolism demonstrated reversible or irreversible findings in magnetic resonance (MR) imaging over time and to compare the features in MR images with histologic findings in a cat model. MATERIALS AND METHODS:MR images were obtained...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000077055.48406.e2

    authors: Kim HJ,Lee CH,Lee SH,Moon TY

    更新日期:2003-10-01 00:00:00

  • Effects of angiographic needle size and subsequent catheter insertion on arterial walls. An in vitro experiment in human cadavers.

    abstract:RATIONALE AND OBJECTIVES:It is widely believed that down-sizing catheters, and possibly needles, will decrease damage to the entry vessel in the performance of angiography. The purposes of this in vitro experiment are to determine if smaller needles produce less arterial wall damage than larger needles and to assess th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00001

    authors: Smith DC,Hamlin JA,Jensen DA,Pappas JM,Westengard JC,Saukel GW