Depiction of reperfused myocardial infarction using contrast-enhanced spin echo and gradient echo magnetic resonance imaging.

Abstract:

RATIONALE AND OBJECTIVES:The authors used gadolinium (Gd) chelate as a T1, T2, and T2* enhancing agent in reperfused myocardial infarction to compare the appearance of reperfused myocardial infarction on spin echo and gradient echo magnetic resonance (MR) sequences. METHODS:Rats (n = 28) were subjected to reperfused myocardial infarction and received no contrast medium, 0.2, 0.5, or 1.0 mmol/kg Gd DTPA-BMA. Spin echo and gradient echo MR images of the excised hearts (n = 7 rats per group) were acquired using 2.0 T system: repetition time (TR)/echo time (TE) = 300/20 ms for T1-weighted spin echo, TR/TE = 4000/80 ms for T2-weighted spin echo, and TR/TE = 600/10, 15, 20, and 30 ms for gradient echo imaging. Regional T2 and T2* relaxation times were measured. Triphenyl tetrazolium chloride was used to verify regional infarction. RESULTS:Unenhanced spin echo images failed to distinguish infarcted from normal myocardium. On Gd DTPA-BMA enhanced T1-weighted spin echo images, infarction was depicted as a high-intensity region "hot spot." On the other hand, the infarcted region was visualized as a low-signal region "cold spot" on Gd DTPA-BMA enhanced T2-weighted images. Changes in signal intensity and T2 relaxation time on T2 weighted images were dose dependent. On gradient recalled echo images, the infarcted region was discriminated from normal myocardium by a dark boundary zone, which was visible only at 1.0 mmol/kg. The presence of infarction was documented in every heart. CONCLUSIONS:The contrast between normal and infarcted myocardium was affected greatly by the dose and imaging parameters. The results indicate that spin echo and gradient echo images have greatly differing sensitivities to extracellular gadolinium chelates. Changes in myocardial T2 relaxation time, but not T2*, correlated well with the dose.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Geschwind JF,Saeed M,Wendland MF,Higgins CB

doi

10.1097/00004424-199807000-00002

subject

Has Abstract

pub_date

1998-07-01 00:00:00

pages

386-92

issue

7

eissn

0020-9996

issn

1536-0210

journal_volume

33

pub_type

杂志文章
  • New contrast media designed for x-ray energy subtraction imaging in digital mammography.

    abstract:RATIONALE AND OBJECTIVES:In contrast-enhanced dual-energy subtraction imaging 2 images acquired postcontrast media administration at different energies are subtracted to highlight structures hidden in the absence of contrast media. X-ray spectra of the newly developed digital full-field mammography units (GE Senographe...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.RLI.0000077124.24140.bd

    authors: Lawaczeck R,Diekmann F,Diekmann S,Hamm B,Bick U,Press WR,Schirmer H,Schön K,Weinmann HJ

    更新日期:2003-09-01 00:00:00

  • Effect of additional cations on the twitching reaction to intracarotid, nonionic contrast media in rabbits.

    abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199009000-00010

    authors: Whisson CC,Evill CA,Sage MR,Wilson AJ

    更新日期:1990-09-01 00:00:00

  • CT Dosimetry: What Has Been Achieved and What Remains to Be Done.

    abstract::Radiation dose in computed tomography (CT) has become a hot topic due to an upward trend in the number of CT procedures worldwide and the relatively high doses associated with these procedures. The main aim of this review article is to provide an overview of the most frequently used metrics for CT radiation dose chara...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000727

    authors: Damilakis J

    更新日期:2021-01-01 00:00:00

  • Consistency of rotator-cuff calcifications. Observations on plain radiography, sonography, computed tomography, and at needle treatment.

    abstract:RATIONALE AND OBJECTIVES:The author analyzes findings of consistency of rotator-cuff calcifications found at ultrasound (US)-guided needle treatment compared with findings of plain radiography, US, and computed tomography (CT). METHODS:Twenty patients had rotator-cuff calcifications (mean diameter, 1.5 cm; range, 1.1-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199605000-00010

    authors: Farin PU

    更新日期:1996-05-01 00:00:00

  • Magnetic resonance osteodensitometry in human heel bones: correlation with quantitative computed tomography using different measuring parameters.

    abstract:RATIONALE AND OBJECTIVES:Density of trabecular bone structures in human heel bones was assessed by 3D magnetic resonance (MR) gradient echo imaging (GEI) with multiple echoes. Different spatial resolutions were applied to investigate the influence of the pixel size on signal characteristics in GEI and to find suitable ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200007000-00001

    authors: Machann J,Schnatterbeck P,Raible A,Lutz O,Claussen CD,Schick F

    更新日期:2000-07-01 00:00:00

  • Quantification of Aortic Stiffness by Ultrasound Time-Harmonic Elastography: The Effect of Intravascular Pressure on Elasticity Measures in a Porcine Model.

    abstract:OBJECTIVES:The aim of this study was to investigate blood pressure dependency of ultrasound time-harmonic elastography (THE) for quantification of aortic stiffness. MATERIALS AND METHODS:Thoracoabdominal aortas were surgically removed from 9 healthy domestic pigs and prepared for elastographic experiments. All vessels...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000618

    authors: Schaafs LA,Tzschätzsch H,Steffen IG,Braun J,Hamm B,Sack I,Elgeti T

    更新日期:2020-03-01 00:00:00

  • Blood velocity calculated from volumetric dynamic computed tomography angiography.

    abstract:OBJECTIVE:Though functional intravascular parameters such as blood velocity and direction of blood flow are available via imaging modalities such as Doppler ultrasound and phase contrast magnetic resonance imaging, such quantitative information is not yet supported by computed tomography (CT). In this study, we examine...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181ea3588

    authors: Barfett JJ,Fierstra J,Mikulis DJ,Krings T

    更新日期:2010-12-01 00:00:00

  • Experimental tissue damage after subcutaneous injection of water soluble contrast media.

    abstract::Various water soluble contrast media (WSCM) were injected subcutaneously into 970 hind feet of 485 rats. Gross morphologic changes were seen after the injection and analyzed as a function of various physicochemical characteristics of WSCM. The WSCM of larger volume, higher osmolality, higher iodine content, and meglum...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199006000-00011

    authors: Kim SH,Park JH,Kim YI,Kim CW,Han MC

    更新日期:1990-06-01 00:00:00

  • Noninvasive measurement of an index of renal blood flow.

    abstract::A new technique for the noninvasive measurement of an index of renal blood flow is described. The method utilizes ultrasound determined renal volume and radionuclide assessment of the mean transit time of a pertechnetate bolus through the kidneys. From this information a value for flow is calculated according to compa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198307000-00009

    authors: Powers TA,Rees RS,Bowen RD

    更新日期:1983-07-01 00:00:00

  • Contrast-detail phantom study for x-ray spectrum optimization regarding chest radiography using a cesium iodide-amorphous silicon flat-panel detector.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study evaluating a cesium iodide-amorphous silicon-based flat-panel detector was to optimize the x-ray spectrum for chest radiography combining excellent contrast-detail visibility with reduced patient exposure. MATERIALS AND METHODS:A Lucite plate with 36 drilled holes of ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000138091.96320.f8

    authors: Hamer OW,Völk M,Zorger N,Borisch I,Büttner R,Feuerbach S,Strotzer M

    更新日期:2004-10-01 00:00:00

  • Dynamic contrast-enhanced computed tomography as a potential biomarker in patients with metastatic renal cell carcinoma: preliminary results from the Danish Renal Cancer Group Study-1.

    abstract:OBJECTIVES:The aim of this study was to explore the impact of dynamic contrast-enhanced (DCE) computer tomography (CT) as a biomarker in metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS:Twelve patients with favorable or intermediate Memorial Sloan Kettering Cancer Center risk group and clear cell mRCC par...

    journal_title:Investigative radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/RLI.0000000000000058

    authors: Mains JR,Donskov F,Pedersen EM,Madsen HH,Rasmussen F

    更新日期:2014-09-01 00:00:00

  • Assessment of osteosarcoma response to preoperative chemotherapy using dynamic FLASH gadolinium-DTPA-enhanced magnetic resonance mapping.

    abstract:RATIONALE AND OBJECTIVES:To improve the accuracy of magnetic resonance imaging (MRI) in evaluating the response of osteosarcomas to preoperative chemotherapy, the authors developed a technique of mapping tumor necrosis and viability by quantitating slope values of gadolinium-DTPA (Gd-DTPA) uptake on dynamic fast low-an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199205000-00010

    authors: Hanna SL,Parham DM,Fairclough DL,Meyer WH,Le AH,Fletcher BD

    更新日期:1992-05-01 00:00:00

  • Time course of satisfaction of search.

    abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199107000-00003

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Rooholamini SA,Coffman CE,Cornell SH,Cragg AH,Galvin JR,Honda H,Kao SC

    更新日期:1991-07-01 00:00:00

  • Reproducibility, accuracy, and predictors of accuracy for the detection of coronary atherosclerotic plaque composition by computed tomography: an ex vivo comparison to intravascular ultrasound.

    abstract:PURPOSE:To determine the reproducibility, accuracy, and predictors of accuracy of computed tomography (CT) angiography to detect and characterize coronary atherosclerotic plaque as compared with intravascular ultrasound. METHODS:Ten ex vivo human coronary arteries were imaged in a moving phantom by dual-source CT (col...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e0a541

    authors: van der Giessen AG,Toepker MH,Donelly PM,Bamberg F,Schlett CL,Raffle C,Irlbeck T,Lee H,van Walsum T,Maurovich-Horvat P,Gijsen FJ,Wentzel JJ,Hoffmann U

    更新日期:2010-11-01 00:00:00

  • The uptake of manganese dipyridoxal-diphosphate by chemically induced hepatocellular carcinoma in rats. A correlation between contrast-media-enhanced magnetic resonance imaging, tumor differentiation, and vascularization.

    abstract:OBJECTIVES AND RATIONALE:Negative enhancement of implanted liver tumors has been achieved in preclinical studies on manganese dipyridoxal-diphosphate (Mn-DPDP), a new hepatobiliary specific contrast agent for magnetic resonance imaging (MRI). The authors investigated the effects of Mn-DPDP on primary liver cancer and i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199306000-00011

    authors: Ni Y,Marchal G,Zhang X,Van Hecke P,Michiels J,Yu J,Rummeny E,Lodemann KP,Baert AL

    更新日期:1993-06-01 00:00:00

  • Temporal changes in the oxidation state in in vitro blood.

    abstract::The rates at which the paramagnetic compounds deoxyhemoglobin (Hb) and methemoglobin (MHb) form in vivo within an area of hemorrhage are unknown. The present experiment establishes the baseline concentrations and rates of change in paramagnetic hemoglobin concentrations, as well as the pH in normal heparinized and clo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199003000-00006

    authors: Taber KH,Migliore PJ,Pagani JJ,Ford JJ,McLauren T,Hayman LA

    更新日期:1990-03-01 00:00:00

  • Systemic absorption of gallbladder sclerosing agents in the rabbit. A preliminary study.

    abstract::The absorbed levels of ethanol or tetracycline, used as gallbladder sclerosing agents, were measured in the systemic blood circulation of 16 rabbits. The maximal systemic level of ethanol was 46 mg/dl and of tetracycline was 4.6 micrograms/ml after 30 minutes of gallbladder exposure. Comparable serum levels would be c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198605000-00005

    authors: Remley KB,Cubberley DA,Watanabe AS,Nelson JA,Colby TV

    更新日期:1986-05-01 00:00:00

  • Magnetic resonance imaging-guided percutaneous biopsy of mediastinal masses: diagnostic performance and safety.

    abstract:OBJECTIVE:The objective of this study was to evaluate the diagnostic performance and safety of magnetic resonance (MR) imaging-guided percutaneous mediastinal biopsy procedures using a 0.23-T open MR system with optical tracking navigation. MATERIALS AND METHODS:A retrospective analysis of 59 participants (38 males an...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0b013e31827a4a17

    authors: Lü Y,Fritz J,Li C,Liu M,Lee P,Wu L,Carrino JA

    更新日期:2013-06-01 00:00:00

  • A method for the study of regional ischemic dysfunction in the intact dog. Permanent endocardial markers and the pressure-length loop.

    abstract::A radiographic method for use in the closed-chest dog is described which allows the quantitation of segmental mechanical performance. Previous work has shown that the area of the pressure-length loop (an approximation of a stress-strain integral) is a useful measure of the mechanical work performed by a segment of myo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197611000-00010

    authors: Ringertz HG,Carlsson E,Tyberg JV

    更新日期:1976-11-01 00:00:00

  • The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques.

    abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00016

    authors: Rockette HE,Gur D,Metz CE

    更新日期:1992-02-01 00:00:00

  • Noninvasive estimation of organ weights by postmortem magnetic resonance imaging and multislice computed tomography.

    abstract:OBJECTIVE:Computed tomography (CT) and magnetic resonance imaging (MRI) are introduced as an alternative to traditional autopsy. The purpose of this study was to investigate their accuracy in mass estimation of liver and spleen. METHODS:In 44 cases, the weights of spleen and liver were estimated based on MRI and CT da...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000221323.38443.8d

    authors: Jackowski C,Thali MJ,Buck U,Aghayev E,Sonnenschein M,Yen K,Dirnhofer R,Vock P

    更新日期:2006-07-01 00:00:00

  • Image fusion in dual energy computed tomography: effect on contrast enhancement, signal-to-noise ratio and image quality in computed tomography angiography.

    abstract:OBJECTIVE:The aim of this study was to evaluate the influence of different weighting factors on contrast enhancement, signal-to-noise ratio (SNR), and image quality in image fusion in dual energy computed tomography (DECT) angiography. MATERIAL AND METHODS:Fifteen patients underwent a CT angiography of the aorta with ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31818c3d4b

    authors: Behrendt FF,Schmidt B,Plumhans C,Keil S,Woodruff SG,Ackermann D,Mühlenbruch G,Flohr T,Günther RW,Mahnken AH

    更新日期:2009-01-01 00:00:00

  • Evaluation of diffusion-weighted MR imaging at inclusion in an active surveillance protocol for low-risk prostate cancer.

    abstract:PURPOSE:We aimed to determine whether diffusion-weighted magnetic resonance imaging, by means of the apparent diffusion coefficient (ADC), is able to guide magnetic resonance-guided biopsy in patients fit for active surveillance (AS) and identify patients harboring high-grade Gleason components not suitable for AS. MA...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31827b711e

    authors: Somford DM,Hoeks CM,Hulsbergen-van de Kaa CA,Hambrock T,Fütterer JJ,Witjes JA,Bangma CH,Vergunst H,Smits GA,Oddens JR,van Oort IM,Barentsz JO,MR-PRIAS Collaboration Group.

    更新日期:2013-03-01 00:00:00

  • Magnetic resonance pulmonary angiography and direct imaging of embolus for the detection of pulmonary emboli.

    abstract:RATIONALE AND OBJECTIVES:The authors developed a two-dimensional breathhold magnetic resonance (MR) technique for the direct imaging of pulmonary emboli. METHODS:In vitro MR imaging was performed to demonstrate the potential generation of clot-blood contrast by in vivo pulmonary embolism (PE). A two-dimensional magnet...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199708000-00001

    authors: Moody AR,Liddicoat A,Krarup K

    更新日期:1997-08-01 00:00:00

  • In vivo and in vitro evaluation of Gd-DTPA-polylysine as a macromolecular contrast agent for magnetic resonance imaging.

    abstract::Polylysine covalently linked to moieties of gadopentetate (Gd-DTPA), for use as a macromolecular blood pool marker for contrast material-enhanced magnetic resonance imaging (MRI), was characterized by means of physicochemical measurements and pharmacokinetics in rats and rabbits and compared with Gd-DTPA. Gd-DTPA-poly...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199111000-00008

    authors: Schuhmann-Giampieri G,Schmitt-Willich H,Frenzel T,Press WR,Weinmann HJ

    更新日期:1991-11-01 00:00:00

  • The influence of contrast medium dose on filtration fraction in the rabbit kidney.

    abstract::We have examined the effect of dose on contrast medium-induced reductions in glomerular filtration in anesthetized rabbits. The fraction of renal plasma flow that is filtered, the filtration fraction, was directly measured by the renal arteriovenous difference method using technetium-99m (99mTc) (Sn) DTPA as the trace...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198309000-00007

    authors: Harvey LA,Caldicott WJ

    更新日期:1983-09-01 00:00:00

  • Combined methods for assessment of neurotoxicity: testing of new nonionic radiographic media.

    abstract::A battery of tests for toxicity assessment of new contrast media is reviewed. Cell toxicity in a protozoan culture (Blepharisma americanum); lethal dose determination in mice; EEG Spectral analysis following cisternography in rabbits; ED50 and LD50 determination by intra- and pericerebral injection in rats; intraciste...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011001-00053

    authors: Sovak M,Siefert HM,Ranganathan R

    更新日期:1980-11-01 00:00:00

  • An overview of neck node sonography.

    abstract:RATIONALE AND OBJECTIVES:Gray scale and power Doppler sonography are commonly used to evaluate cervical lymph nodes. This study was undertaken to identify which of the features used in ultrasound of cervical lymph nodes is readily applicable in routine clinical practice. METHODS:Two hundred and eight-six patients diag...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200206000-00005

    authors: Ahuja A,Ying M

    更新日期:2002-06-01 00:00:00

  • Extravascular extravasation of radiographic contrast media. Effects of conventional and low-osmolar agents in the rat thigh.

    abstract::We compared the damage resulting from intradermal injection of four commonly used radiographic contrast media in laboratory rats. Sixty percent meglumine diatrizoate (Reno M 60) and ioxaglate (Hexabrix) produced significantly more ulceration and crusting on gross inspection and more necrosis, edema, and hemorrhage on ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199005000-00006

    authors: Cohan RH,Leder RA,Bolick D,Herzberg AJ,Hedlund LW,Wheeler CT,Helms MJ,Dunnick NR

    更新日期:1990-05-01 00:00:00

  • Keratinization and necrosis. Morphologic aspects of lymphatic metastases in ultrasound.

    abstract:RATIONALE AND OBJECTIVE:The authors performed a retrospective study in ultrasound to investigate new aspects in the sonomorphology of lymph node metastases of the neck. In this study, it could be demonstrated the first time that the histologic characteristics of the metastases determine the sonographic appearance. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199609000-00001

    authors: Mäurer J,Willam C,Steinkamp HJ,Knollmann FD,Felix R

    更新日期:1996-09-01 00:00:00