Abstract:
:The absorbed levels of ethanol or tetracycline, used as gallbladder sclerosing agents, were measured in the systemic blood circulation of 16 rabbits. The maximal systemic level of ethanol was 46 mg/dl and of tetracycline was 4.6 micrograms/ml after 30 minutes of gallbladder exposure. Comparable serum levels would be considered nontoxic in humans. As a gallbladder sclerosing agent, tetracycline (50 mg/cc) was slightly more effective than 95% ethanol exposed for either 15 or 30 minutes.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Remley KB,Cubberley DA,Watanabe AS,Nelson JA,Colby TVdoi
10.1097/00004424-198605000-00005subject
Has Abstractpub_date
1986-05-01 00:00:00pages
396-9issue
5eissn
0020-9996issn
1536-0210journal_volume
21pub_type
杂志文章abstract::The problem of inhomogeneous mixing encountered during hepatic artery (HA) chemotherapy infusion was assessed and a practical solution examined. A glass model of the human HA distribution was used to determine mixing homogeneity of low flow (1.4 mL/minute) dye infusion into pulsatile flow (280-300 mL/minute) of a flui...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198807000-00007
更新日期:1988-07-01 00:00:00
abstract::Radiation dose in computed tomography (CT) has become a hot topic due to an upward trend in the number of CT procedures worldwide and the relatively high doses associated with these procedures. The main aim of this review article is to provide an overview of the most frequently used metrics for CT radiation dose chara...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000727
更新日期:2021-01-01 00:00:00
abstract::We developed a new, cineangiographic method to accurately measure the dynamic changes in the internal diameter of human arteries in vivo. Cine films were digitized at a spatial resolution of 4 microns/pixel, using a line image sensor. The vessel edges, with a Gaussian fit to a unilateral profile curve of the vessel, w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198909000-00005
更新日期:1989-09-01 00:00:00
abstract:OBJECTIVE:: The final event leading to myocardial infarction is adhesion and activation of platelets after rupture of an atherosclerotic plaque, ending in thrombotic occlusion of the coronary artery. Imaging of imminent vessel occlusion may improve patient care. The feasibility of molecular magnetic resonance imaging (...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e31821e62fb
更新日期:2011-10-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. METHODS:Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mo...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199904000-00005
更新日期:1999-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Hepatocellular carcinomas (HCCs) usually consist of components of different histologic grade. Using surgically resected specimens, the authors obtained high-resolution magnetic resonance (MR) images and studied the relationship between histologic grade of HCCs and MR signal intensity. METHOD:I...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199308000-00007
更新日期:1993-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Diabetic patients frequently suffer contrast media-induced nephropathy. Hyperglycemia in diabetes mellitus causes gradual deterioration of glomerular mesangial cells (MCs) in the kidney. In this study, the authors investigated the response of rat MCs cultured in high-glucose medium to diatrizoa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200107000-00001
更新日期:2001-07-01 00:00:00
abstract::Prior studies of the opacification-phase effects of left ventricular (LV) injection of angiographic contrast medium (CM) on LV size and function have yielded discrepant results. A sensitive ultrasonic technique was used to measure LV dimension (Di) in 10 open-chest dogs with physiologic heart rates, and injection of s...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198209000-00009
更新日期:1982-09-01 00:00:00
abstract:OBJECTIVES:Transcatheter arterial embolization (TAE) is used for the treatment of patients with malignant liver tumors. However, the proangiogenesis effect of TAE-associated hypoxia has not been adequately studied. The goal of this study was to determine angiogenic activity in tumors subjected to TAE by evaluating the ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000209663.00629.8a
更新日期:2006-06-01 00:00:00
abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199105000-00009
更新日期:1991-05-01 00:00:00
abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199107000-00003
更新日期:1991-07-01 00:00:00
abstract:INTRODUCTION:The aim of the present study was to evaluate the potential of high-resolution MRI at 2 Tesla (T) for direct noninvasive imaging of the aortic wall in a mouse model of atherosclerosis. MATERIAL AND METHODS:A specific mouse antenna was developed and sequence parameters were adjusted. T(1)- and T2-weighted i...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000067491.31978.1c
更新日期:2003-08-01 00:00:00
abstract:PURPOSE:The aim of this study was to evaluate the feasibility of a prototype volume-interpolated breath-hold examination (VIBE) sequence using compressed sensing (VIBECS) for rapid multiphase arterial magnetic resonance imaging (MRI) at different temporal resolution during free-breathing in comparison with a convention...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000459
更新日期:2018-10-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lym...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000218
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:Over the recent years, there have been increasing concerns that exposure to gadolinium-based contrast agents (GBCAs) may be associated with retention of Gd within the skin, bones, and solid organs in patients with normal renal function, although the clinical implications of this deposition remain to be estab...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000657
更新日期:2020-07-01 00:00:00
abstract:PURPOSE:To determine whether liver metastases conspicuity is improved at 80 kVp when compared with weighted average (WA) simulated 120 kVp data using dual source dual energy CT. METHODS:A total of 11 patients with 44 hypo-vascular liver metastases underwent contrast enhanced Dual Energy CT (DECT). In all cases the sub...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181dfda78
更新日期:2010-07-01 00:00:00
abstract::Various water soluble contrast media (WSCM) were injected subcutaneously into 970 hind feet of 485 rats. Gross morphologic changes were seen after the injection and analyzed as a function of various physicochemical characteristics of WSCM. The WSCM of larger volume, higher osmolality, higher iodine content, and meglum...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199006000-00011
更新日期:1990-06-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to perform phantom measurements to prove the feasibility of single-source dual-energy computed tomography (DECT) of the extremities using a volume scan mode. In addition, we, for the first time, wanted to determine which concentrations of monosodium urate (MSU) in gout and calcium p...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000099
更新日期:2015-04-01 00:00:00
abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181b66d11
更新日期:2009-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study assesses the ability of a cardiac-gated phase-contrast magnetic resonance imaging (MRI) technique to measure renal blood flow (RBF) noninvasively in humans. METHODS:In nine normal volunteers, total RBF in the renal arteries and in the left renal vein was estimated by MRI and correla...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199206000-00012
更新日期:1992-06-01 00:00:00
abstract:PURPOSE:To evaluate the dependency of tumor contrast enhancement (CE) in regard to protein-binding properties of contrast agents, using 4 different agents with a wide range of protein-binding capacities in a standardized rat brain glioma model. MATERIAL AND METHODS:Sixteen rats with implanted brain gliomas were evalua...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318191a334
更新日期:2009-02-01 00:00:00
abstract:PURPOSE:Magnetic Resonance Imaging (MRI) has become the method of choice in the evaluation of patients with suspected cervical artery dissection (CAD). However, reliable identification of acute CAD might be impaired by the limited spatial resolution of standard 1.5 T MRI. In this preliminary study, we implemented a mul...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000195836.57778.1f
更新日期:2006-02-01 00:00:00
abstract::Recent publications of the magnetic resonance safety profile of neurostimulators, cardiac pacemakers, and other implanted devices imply that these devices are no longer a contraindication for magnetic resonance imaging. It is very promising that patients who have these implanted devices may in the future no longer be ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000185898.59140.91
更新日期:2005-12-01 00:00:00
abstract:OBJECTIVE:BR55, a vascular endothelial growth factor receptor 2 (VEGFR2)-specific ultrasound molecular contrast agent (MCA), has shown promising results in multiple preclinical models regarding cancer imaging. In this first-in-human, phase 0, exploratory study, we investigated the feasibility and safety of the MCA for ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000362
更新日期:2017-07-01 00:00:00
abstract:OBJECTIVES:The goal of this study was to demonstrate feasibility of measuring extracellular pH in cartilage and meniscus using acidoCEST technique with a 3-dimensional ultrashort echo time readout (acidoCEST-UTE) magnetic resonance imaging (MRI). MATERIALS AND METHODS:Magnetization transfer ratio asymmetry, radiofrequ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000576
更新日期:2019-09-01 00:00:00
abstract::The rate at which isotopes descend from the cisterna magna to the lumbar subarachnoid space is highly variable. In monkeys, with and without previous lumbar puncture, transit time was measured. In animals with a previous lumbar puncture, transit times were 10 to 120 minutes; in monkeys without a previous lumbar punctu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198805000-00005
更新日期:1988-05-01 00:00:00
abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198602000-00015
更新日期:1986-02-01 00:00:00
abstract::We investigated the feasibility of using intravascular ultrasound imaging to analyze vascular physiology in various arterial beds. Canine superficial femoral, external iliac, and common carotid arteries were harvested and suspended and perfused in a bath of oxygenated, heated, physiologic salt solution. A 6-Fr, 20-MHz...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199103000-00010
更新日期:1991-03-01 00:00:00
abstract:OBJECTIVE:To investigate the correlation between intravoxel incoherent motion (IVIM) model-derived parameters and histologically determined microvascularity in pancreatic ductal adenocarcinomas (PDACs) and pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:From April 2013 to May 2014, 42 patients with mal...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000187
更新日期:2015-11-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the impact on metal artifacts and dose efficiency of using a tin filter in combination with high-energy threshold (TH) images of a photon-counting detector (PCD) computed tomography (CT) system. MATERIALS AND METHODS:A 3D-printed spine with pedicle screws was scanned...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000535
更新日期:2019-04-01 00:00:00