Contrast gradient and the detection of lung nodules.

Abstract:

:The effects of edge gradient and blur on the detection pulmonary nodules were studied, using a test series of 175 artificial nodules on 30 chest films. The nodules were of homogeneous texture, about 1 cm in diameter and had a mean contrast of .12. Six observers viewed the film set, scoring both location and confidence. The sensitivity or the probability of a true-positive response was linearly related to the blur and a modified ROC analysis resulted in a family of ROC curves with the index of detectability monotonically decreasing with increased blur.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Kundel HL,Revesz G,Toto L

doi

10.1097/00004424-197901000-00004

subject

Has Abstract

pub_date

1979-01-01 00:00:00

pages

18-22

issue

1

eissn

0020-9996

issn

1536-0210

journal_volume

14

pub_type

杂志文章
  • Response of tumors to therapy studied by 31P magnetic resonance spectroscopy.

    abstract::Magnetic resonance (MR) methods have been used to study the metabolic and vascular response of model tumors to tumor necrosis factor (TNF). Magnetic resonance measurements demonstrated acute reductions in tumor blood flow, measured from tumor uptake of D2O, and in tumor adenosine triphosphate (ATP), measured by 31P ma...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198912000-00022

    authors: Karczmar GS,Meyerhoff DJ,Speder A,Valone F,Wilkinson M,Shine N,Boska MD,Weiner MW

    更新日期:1989-12-01 00:00:00

  • Intracranial arteriovenous malformations. Current imaging and treatment.

    abstract::Patients with intracranial arteriovenous malformations (AVM) can expect significant mortality (15% to 20%) and morbidity (20% to 30%) over a 15-year to 20-year period. Recent advances in interventional neuroradiology, neurosurgery, neuroanesthesia, and stereotactic radiotherapy provide the opportunity to obliterate ma...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199008000-00014

    authors: Graves VB,Duff TA

    更新日期:1990-08-01 00:00:00

  • Antiproliferative effects of the antiallergic agent azelastine on human aortic smooth-muscle cells: an in vitro study.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to examine the effects of azelastine on proliferation, clonogenic activity, cell-cycle, and migration of human aortic smooth-muscle cells (haSMCs) in vitro. METHODS:HaSMCs were treated for 4 days with azelastine (1 micromol/L, 25 micromol/L, 50 micromol/L). Half of the...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200205000-00002

    authors: Schöber W,Wiskirchen J,Kehlbach R,Gebert R,Rodegerdts E,Betsch A,Johst U,Feuls R,Claussen CD,Duda SD

    更新日期:2002-05-01 00:00:00

  • Intravoxel incoherent motion diffusion-weighted imaging of pancreatic neuroendocrine tumors: prediction of the histologic grade using pure diffusion coefficient and tumor size.

    abstract:PURPOSE:The purpose of this study was to assess the value of intravoxel incoherent motion and diffusion-weighted imaging for predicting the histologic grade of pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:Forty patients with surgically diagnosed PNETs who underwent preoperative magnetic resonance im...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000028

    authors: Hwang EJ,Lee JM,Yoon JH,Kim JH,Han JK,Choi BI,Lee KB,Jang JY,Kim SW,Nickel MD,Kiefer B

    更新日期:2014-06-01 00:00:00

  • Temperature-Sensitive Frozen-Tissue Imaging for Cryoablation Monitoring Using STIR-UTE MRI.

    abstract:PURPOSE:The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than -40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000642

    authors: Tokuda J,Wang Q,Tuncali K,Seethamraju RT,Tempany CM,Schmidt EJ

    更新日期:2020-05-01 00:00:00

  • Free-Breathing Dynamic Contrast-Enhanced Imaging of the Upper Abdomen Using a Cartesian Compressed-Sensing Sequence With Hard-Gated and Motion-State-Resolved Reconstruction.

    abstract:OBJECTIVES:The aim of this study was to compare a compressed-sensing free-breathing VIBE (fbVIBE) with a conventional breath-hold VIBE (bhVIBE) for dynamic contrast-enhanced imaging of the upper abdomen. MATERIALS AND METHODS:In total, 70 datasets (bhVIBE, n = 30; fbVIBE n = 40; hard-gated [hg] reconstruction, n = 30;...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000607

    authors: Hausmann D,Niemann T,Kreul D,Nocito A,Klarhöfer M,Nickel DM,Kiefer B,Attenberger UI,Zöllner FG,Kubik-Huch RA

    更新日期:2019-11-01 00:00:00

  • Evaluation of intrarenal oxygenation at 3.0 T using 3-dimensional multiple gradient-recalled echo sequence.

    abstract:OBJECTIVE:The objective of this study was to validate quantitation of R2* and DeltaR2* measurements obtained with a 3-dimensional (3-D) multiple gradient-recalled echo (mGRE) sequence for evaluating intrarenal oxygenation in humans. MATERIALS AND METHODS:Validation was accomplished (1) by comparing R2* values with pre...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000187166.43871.fb

    authors: Tumkur S,Vu A,Li L,Prasad PV

    更新日期:2006-02-01 00:00:00

  • Assessment of a non-ionic contrast medium (Amipaque) in the gastrointestinal tract.

    abstract::Gastrografin and Amipaque with identical iodine content and flavoring were orally administered in 100 ml doses to 10 healthy volunteers in a double-blind crossover study. The nonionic Amipaque has only about one third of the osmolality of Gastrografin, and draws less fluid into the bowel lumen. Consequently there is l...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-197811000-00008

    authors: Johansen JG

    更新日期:1978-11-01 00:00:00

  • Dynamic contrast-enhanced computed tomography as a potential biomarker in patients with metastatic renal cell carcinoma: preliminary results from the Danish Renal Cancer Group Study-1.

    abstract:OBJECTIVES:The aim of this study was to explore the impact of dynamic contrast-enhanced (DCE) computer tomography (CT) as a biomarker in metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS:Twelve patients with favorable or intermediate Memorial Sloan Kettering Cancer Center risk group and clear cell mRCC par...

    journal_title:Investigative radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/RLI.0000000000000058

    authors: Mains JR,Donskov F,Pedersen EM,Madsen HH,Rasmussen F

    更新日期:2014-09-01 00:00:00

  • A large animal model (swine) to study the diagnosis and treatment of cholelithiasis.

    abstract::Human gallstones were surgically placed into the gallbladders of 200 swine. Eight of these swine were used as a prospective series to verify that the placement and presence of human gallstones in their gallbladders caused no significant pathologic changes in the gallbladder and that the gallstones were not spontaneous...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198902000-00005

    authors: Griffith SL,Burney BT,Fry FJ,Franklin TD Jr

    更新日期:1989-02-01 00:00:00

  • The effects of orientation on volume measurements of human left ventricular casts.

    abstract::Biplane angiocardiography has emerged as a standard method for calculating left ventricular volume measurements. Validation of such measurements has separately been made for several projections of silicone casts of the left ventricle. This study was undertaken to establish and compare the regression lines for left ven...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198011000-00002

    authors: Lipton MJ,Hayashi TT,Davis PL,Carlsson E

    更新日期:1980-11-01 00:00:00

  • Biodistribution and excretion of 125I ioversol in conscious dogs.

    abstract::Radiolabeled ioversol was injected intravenously into two male and two female beagle dogs (6.7 to 10.4 kg) at two dose levels each (0.2 and 1.0 g I/kg). Blood levels of radioactivity were monitored at 2, 5, 10, 20, 40, 60, 90, and 120 minutes and at one and two days. Urine and feces were collected in metabolism cages ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198906001-00005

    authors: Coveney JR,Robbins MS

    更新日期:1989-06-01 00:00:00

  • Dynamic contrast-enhanced ultrasound for assessment of skeletal muscle microcirculation in peripheral arterial disease.

    abstract:OBJECTIVE:: This feasibility study was performed to assess whether dynamic contrast-enhanced ultrasound (CEUS) and transient arterial occlusion are able to detect alterations in the microvascular perfusion and arterial perfusion reserve in patients suffering from peripheral arterial disease (PAD) in comparison with hea...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182183a77

    authors: Amarteifio E,Weber MA,Wormsbecher S,Demirel S,Krakowski-Roosen H,Jöres A,Braun S,Delorme S,Böckler D,Kauczor HU,Krix M

    更新日期:2011-08-01 00:00:00

  • The effect of certain variables on the tumor and tissue distribution of tracers: VI. False-carrier effect, Part III, Fe.

    abstract::Previous work has shown that Fe3+, when administered in the proper dose and time sequence, increases the tumor uptake of gallium-67 (67Ga) while decreasing its uptake by normal tissues. The purpose of this series of experiments was to examine further the postulate that the false carrier effect is mediated at the cellu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198207000-00016

    authors: Stern PH,Halpern SE,Hagan PL,Chen A

    更新日期:1982-07-01 00:00:00

  • Application of a Novel Iterative Denoising and Image Enhancement Technique in T1-Weighted Precontrast and Postcontrast Gradient Echo Imaging of the Abdomen: Improvement of Image Quality and Diagnostic Confidence.

    abstract:OBJECTIVES:The aim of this study was to investigate the impact of a novel iterative denoising and image enhancement technique in T1-weighted precontrast and postcontrast volume-interpolated breath-hold examination (VIBE) of the abdomen on image quality, noise levels, and diagnostic confidence without change of acquisit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000746

    authors: Gassenmaier S,Afat S,Nickel D,Kannengiesser S,Herrmann J,Hoffmann R,Othman AE

    更新日期:2020-11-18 00:00:00

  • Large-tip-angle spin-echo imaging. Theory and applications.

    abstract:RATIONALE AND OBJECTIVES:Tissue contrast phenomenology was investigated analytically and clinically for a class of magnetic resonance (MR) pulse sequences we call large-tip-angle (LTA) spin-echo (SE) imaging. In comparison to traditional SE sequences (denoted 90 degrees-180 degrees-echo), the LTA sequence is of the for...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199310000-00017

    authors: Elster AD,Provost TJ

    更新日期:1993-10-01 00:00:00

  • Ultrasound analysis of tongue, hyoid, and larynx activity during swallowing.

    abstract::Using real-time ultrasound, the motions of the tongue, hyoid bone, and larynx were monitored and timed during swallowing in ten normal subjects. A well-defined propulsive wave of the tongue was observed during swallowing a 5-cc water bolus. The body of the hyoid bone was identified on the ultrasound scan as a high ech...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198403000-00003

    authors: Shawker TH,Sonies B,Hall TE,Baum BF

    更新日期:1984-03-01 00:00:00

  • Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

    abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a56678

    authors: Vos EK,Sambandamurthy S,Kamel M,McKenney R,van Uden MJ,Hoeks CM,Yakar D,Scheenen TW,Fütterer JJ

    更新日期:2014-01-01 00:00:00

  • Embolization of superior mesenteric artery branches in dogs. Ischemic bowel changes depend on location of vessel occlusion and embolic materials.

    abstract:OBJECTIVE:To evaluate the degree of ischemic changes of the small intestine after arterial embolization of proximal or distal arteries with Gelfoam particles and coils in dogs. METHODS:Superselective arterial embolization in 18 dogs was performed using a coaxial catheter system. Gelfoam occlusion of the proximal level...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199910000-00004

    authors: Han YM,Lee JM,Jin KY,Lee SY,Kim CS

    更新日期:1999-10-01 00:00:00

  • The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques.

    abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00016

    authors: Rockette HE,Gur D,Metz CE

    更新日期:1992-02-01 00:00:00

  • Mechanical thrombectomy in hemodialysis access shunts using a 5F pigtail rotation catheter. In vitro and in vivo investigations.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the feasibility of mechanical thrombectomy in occluded hemodialysis access shunts by using a newly developed 5F pigtail rotation catheter. METHODS:Thrombosed hemodialysis access shunts were simulated by clotted bovine blood in silicone tubing (diameter 6 mm). After retrograde and a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199907000-00008

    authors: Wildberger J,Schmitz-Rode T,Wein BB,Günther RW

    更新日期:1999-07-01 00:00:00

  • Digital mammography using iodine-based contrast media: initial clinical experience with dynamic contrast medium enhancement.

    abstract:PURPOSE:We sought to evaluate the potential of dynamic contrast enhancement after the intravenous administration of an iodine-based contrast medium in full-field digital mammography. MATERIAL AND METHODS:A protocol for image acquisition was established for contrast-enhanced mammography and the mammography unit (Senogr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000167421.83203.4e

    authors: Diekmann F,Diekmann S,Jeunehomme F,Muller S,Hamm B,Bick U

    更新日期:2005-07-01 00:00:00

  • Biodistribution of radiolabeled, formulated gadopentetate, gadoteridol, gadoterate, and gadodiamide in mice and rats.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the long-term distribution of gadolinium (Gd) in mice and rats after the administration of four commercially available magnetic resonance imaging contrast media. The goals were to determine any possible product dissociation in vivo and to evaluate the effects that product ex...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199506000-00008

    authors: Tweedle MF,Wedeking P,Kumar K

    更新日期:1995-06-01 00:00:00

  • The effects of ioxaglate 320, iohexol 350, and iopamidol 370 on erythrocyte aggregation.

    abstract::The authors report a randomized, double-blind prospective trial comparing the effects of nonionic with ionic low-osmolar contrast media on erythrocyte aggregation. The study group comprised 40 consecutive patients with pathology necessitating selective angiography. Patients were examined using either ioxaglate 320, io...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-199108000-00009

    authors: Hayes R,Mahon T,Masterson J,Owens A

    更新日期:1991-08-01 00:00:00

  • A method for evaluating the bronchial circulation. Preliminary observations.

    abstract::Due to the small size of the bronchial arteries, the bronchial circulation is difficult to study and remains poorly understood. We have utilized single photon emission computed tomography (SPECT) as a noninvasive means of studying the bronchial circulation. Imaging studies were performed in sheep before and after the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199001000-00014

    authors: Chiles C,Newman GE,Blinder RA

    更新日期:1990-01-01 00:00:00

  • Towards computer analysis of pulmonary infiltration.

    abstract::A feasibility study is described to provide quantitative texture measures to distinguish between normal lung, alveolar infiltrates and interstitial infiltrates. Advanced computer imaging technology and decision making processes were applied to distinguish between these textural patterns. The results, based on computer...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197807000-00005

    authors: Tully RJ,Conners RW,Harlow CA,Lodwick GS

    更新日期:1978-07-01 00:00:00

  • Magnetic resonance pulmonary angiography and direct imaging of embolus for the detection of pulmonary emboli.

    abstract:RATIONALE AND OBJECTIVES:The authors developed a two-dimensional breathhold magnetic resonance (MR) technique for the direct imaging of pulmonary emboli. METHODS:In vitro MR imaging was performed to demonstrate the potential generation of clot-blood contrast by in vivo pulmonary embolism (PE). A two-dimensional magnet...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199708000-00001

    authors: Moody AR,Liddicoat A,Krarup K

    更新日期:1997-08-01 00:00:00

  • Ultrasound Time-Harmonic Elastography of the Pancreas: Reference Values and Clinical Feasibility.

    abstract:OBJECTIVES:Pancreatic ductal adenocarcinoma (PDAC) is a very aggressive tumor with a very low 5-year survival rate of 8%. The aims of this study are to determine reference values and physiologic confounders in healthy pancreas and to assess the diagnostic accuracy of ultrasound time-harmonic elastography (THE) in the d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000638

    authors: Burkhardt C,Tzschätzsch H,Schmuck R,Bahra M,Jürgensen C,Pelzer U,Hamm B,Braun J,Sack I,Marticorena Garcia SR

    更新日期:2020-05-01 00:00:00

  • The biliary and urinary excretion of sodium tyropanoate and sodium ipodate in dogs: pharmacokinetics, influence of bile salts and choleretic effects with comparison to iopanoic acid.

    abstract::The biliary and urinary excretion of sodium tyropanoate (Bilopaque) and sodium ipodate (Oragrafin) were studied in unanesthetized bile-fistula dogs using stepwise, increasing, intravenous infusions of the contrast materials. A constant intravenous infusion of sodium taurocholate was administered at the rate of either ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197701000-00017

    authors: Berk RN,Loeb PM,Cobo-Frenkel A,Barnhart JL

    更新日期:1977-01-01 00:00:00

  • Digital radiography versus conventional radiography for the detection of a skull fracture under varying exposure parameters.

    abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199303000-00010

    authors: Langen HJ,Klein HM,Wein B,Schiwy-Bochat KH,Stargardt A,Günther RW

    更新日期:1993-03-01 00:00:00