Safety and Oncologic Outcomes of Magnetic Resonance Imaging-Guided Cryoablation of Renal Cell Carcinoma: A 10-Year Single-Center Experience.

Abstract:

OBJECTIVES:Magnetic resonance imaging guidance has been sporadically reported for renal tumor cryoablation (CA); therefore, clinical experience with this modality is still limited.The aim of this study is to retrospectively analyze our 10-year experience with renal tumor CA performed on a 1.5 T magnetic resonance imaging unit with the intent of reporting procedural safety and oncologic outcomes. MATERIALS AND METHODS:We included 143 patients (102 men; 41 women; median age, 73 years; range, 34-91 years) with 149 tumors (median size, 2.6 cm; range, 0.6-6.0 cm), treated between 2009 and 2019. Patient, tumor, procedure, and follow-up data were collected and analyzed. The Kaplan-Meier method was used to estimate local recurrence-free (LRFS), metastasis-free (MFS), disease-free (DFS), cancer-specific, and overall (OS) survival. Univariate and multivariate models were used to identify factors associated with complications, LRFS, MFS, DFS, and OS. RESULTS:The overall complication rate was 10.7% (16/149 tumors), with 1 major (1/149 [0.7%]; 95% confidence interval, 0.0%-3.7%) hemorrhagic complication. Other minor complications (15/149 [10.1%]; 95% confidence interval, 0.6%-16.1%) did not include any cases of injury to nearby organs. There were no factors associated with complications.Five-year estimates of LRFS (primary/secondary), MFS, DFS, cancer-specific survival, and OS were 82.8%/91.5%, 91.1%, 75.1%, 98.2%, and 89.6%, respectively. Increasing tumor size (hazard radio [HR], 1.8; P = 0.02) and intraparenchymal tumor location (HR, 5.6; P < 0.01) were associated with lower LRFS; increasing patient's age (HR, 0.5; P = 0.01), high tumor grade (HR, 23.3; P < 0.01) and non-clear-cell/nonpapillary histology (HR, 20.1; P < 0.01) with metastatic disease; and high tumor grade (HR, 3.2; P = 0.04) with lower DFS. CONCLUSION:Magnetic resonance imaging-guided CA of renal tumors is associated with acceptable morbidity and high survival estimates at 5-year follow-up. Given the absence of complications resulting from injuries to nearby organs, further studies are required to evaluate whether the potential reduced incidence of these adverse events justifies large-scale implementation of this interventional modality.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Cazzato RL,De Marini P,Leonard-Lorant I,Leclerc L,Auloge P,Tricard T,Dalili D,Garnon J,Lang H,Gangi A

doi

10.1097/RLI.0000000000000719

subject

Has Abstract

pub_date

2020-09-04 00:00:00

eissn

0020-9996

issn

1536-0210

pub_type

杂志文章
  • Low-dose transaxial tomography. An alternative to computed tomography for the evaluation of anteversion of the femur during childhood.

    abstract::Low-dose transaxial tomography is a technique that can produce cross-sectional images of the hips and femurs in children to permit calculation of the angle of femoral anteversion. Transaxial tomography was compared with computed tomography in terms of measured radiation dose and image quality. Transaxial tomography wa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kushner DC,Cleveland RH,Ehrlich MG,Zaleske DJ,DeLuca SA,Herman TE,Webster EW

    更新日期:1985-12-01 00:00:00

  • An experimental evaluation of central vs. peripheral injection for intravenous digital subtraction angiography (IV-DSA).

    abstract::At a given radiation dosage and field of view, five variables are under meaningful control for intravenous digital subtraction angiography (IV-DSA): concentration and quantity of contrast media injected, volume of injectate, rate of injection, and site of injection. Some controversy exists regarding the selection of a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198401000-00007

    authors: Rubin DL,Burbank FH,Bradley BR,Brody WR

    更新日期:1984-01-01 00:00:00

  • The retropsoas recess. Demonstration using computed tomography.

    abstract::The retropsoas recess, a previously undescribed normal anatomic variant, is reported. In most individuals, the space posterior to the belly of the psoas muscle contains fat within the posterior pararenal space. However, a retrospective review of 250 consecutive CT examinations of the abdomen revealed 11 cases (4.4%) i...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198707000-00004

    authors: Kelly RB,Mahoney PD,Frick MP

    更新日期:1987-07-01 00:00:00

  • T2-Weighted 4D Magnetic Resonance Imaging for Application in Magnetic Resonance-Guided Radiotherapy Treatment Planning.

    abstract:OBJECTIVES:The aim of this study was to develop and verify a method to obtain good temporal resolution T2-weighted 4-dimensional (4D-T2w) magnetic resonance imaging (MRI) by using motion information from T1-weighted 4D (4D-T1w) MRI, to support treatment planning in MR-guided radiotherapy. MATERIALS AND METHODS:Ten pat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000381

    authors: Freedman JN,Collins DJ,Bainbridge H,Rank CM,Nill S,Kachelrieß M,Oelfke U,Leach MO,Wetscherek A

    更新日期:2017-10-01 00:00:00

  • Measurement of distensibility of blood vessels using cineangiograms.

    abstract::We developed a new, cineangiographic method to accurately measure the dynamic changes in the internal diameter of human arteries in vivo. Cine films were digitized at a spatial resolution of 4 microns/pixel, using a line image sensor. The vessel edges, with a Gaussian fit to a unilateral profile curve of the vessel, w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198909000-00005

    authors: Sugahara T,Yanagihara Y,Uyama C,Maeda H,Takafuchi M,Azumi T

    更新日期:1989-09-01 00:00:00

  • Evaluation of CT time-density curves of lower-limb veins.

    abstract:UNLABELLED:Szapiro D, Ghaye B, Willems V, et al. Evaluation of CT time-density curves of lower-limb veins. Invest Radiol 2001;36:164-169. RATIONALE AND OBJECTIVES:To evaluate time-density curves of the lower-limb veins for optimization of CT venography. METHODS:Fifty patients referred for chest CT were randomized int...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200103000-00005

    authors: Szapiro D,Ghaye B,Willems V,Zhang L,Albert A,Dondelinger RF

    更新日期:2001-03-01 00:00:00

  • The effect of some iodinated contrast media on human plasma butyrylcholinesterase activity.

    abstract::The effect of three iodinated contrast media (CM) on human plasma butyrylcholinesterase (BuChE) activity was studied during the intravenous pyelography (i.v.P). BuChE is an enzyme that participates in the metabolism of acetylcholine and hydrolyzes food esters and drugs such as nondepolarizing muscle relaxants and loca...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199805000-00008

    authors: Mironidou M,Ximitidou O,Christopoulos S,Kokkas B

    更新日期:1998-05-01 00:00:00

  • Role of red blood cell deformation in toxicity of contrast media in cerebral angiography.

    abstract::The authors investigated the effect on the brain of red blood cells that had been modified by contrast media. Rat blood was mixed with an equivolume of contrast media, and up to 200 microL of the mixture was infused to the internal carotid artery of the rat. Evans blue was administered intravenously to assess the inte...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198905000-00009

    authors: Miyazawa T,Nakagawa H,Oshino N

    更新日期:1989-05-01 00:00:00

  • Pancreatic Steatosis Is Associated With Impaired Exocrine Pancreatic Function.

    abstract:OBJECTIVES:The aim of this study was to investigate if pancreatic steatosis measured by proton density fat fraction (PDFF) is associated with exocrine pancreatic function defined by fecal elastase concentrations. MATERIALS AND METHODS:A total of 1458 volunteers (777 women; age range, 21-88 years) underwent magnetic re...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000554

    authors: Kromrey ML,Friedrich N,Hoffmann RT,Bülow R,Völzke H,Weiss FU,Lerch MM,Motosugi U,Kühn JP

    更新日期:2019-07-01 00:00:00

  • Biliary tract depiction in living potential liver donors at 3.0-T magnetic resonance cholangiography.

    abstract:OBJECTIVES:To prospectively evaluate accuracy of biliary anatomy depiction and quality of biliary tract visualization of magnetic resonance cholangiography (MRC) at 3.0 T in living potential liver donors (LPLDs). MATERIALS AND METHODS:Our institutional review board approved this study and did not require patient's inf...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31817e9b52

    authors: Kim SY,Byun JH,Hong HS,Choi EK,Lee SS,Park SH,Lee MG

    更新日期:2008-08-01 00:00:00

  • Dynamic contrast-enhanced computed tomography as a potential biomarker in patients with metastatic renal cell carcinoma: preliminary results from the Danish Renal Cancer Group Study-1.

    abstract:OBJECTIVES:The aim of this study was to explore the impact of dynamic contrast-enhanced (DCE) computer tomography (CT) as a biomarker in metastatic renal cell carcinoma (mRCC). MATERIALS AND METHODS:Twelve patients with favorable or intermediate Memorial Sloan Kettering Cancer Center risk group and clear cell mRCC par...

    journal_title:Investigative radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/RLI.0000000000000058

    authors: Mains JR,Donskov F,Pedersen EM,Madsen HH,Rasmussen F

    更新日期:2014-09-01 00:00:00

  • Effect of transcatheter hepatic arterial embolization on angiogenesis in an animal model.

    abstract:OBJECTIVES:Transcatheter arterial embolization (TAE) is used for the treatment of patients with malignant liver tumors. However, the proangiogenesis effect of TAE-associated hypoxia has not been adequately studied. The goal of this study was to determine angiogenic activity in tumors subjected to TAE by evaluating the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000209663.00629.8a

    authors: Gupta S,Kobayashi S,Phongkitkarun S,Broemeling LD,Kan Z

    更新日期:2006-06-01 00:00:00

  • Improved diagnosis of pulmonary emphysema using in vivo dark-field radiography.

    abstract:OBJECTIVES:The purpose of this study was to assess whether the recently developed method of grating-based x-ray dark-field radiography can improve the diagnosis of pulmonary emphysema in vivo. MATERIALS AND METHODS:Pulmonary emphysema was induced in female C57BL/6N mice using endotracheal instillation of porcine pancr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000067

    authors: Meinel FG,Yaroshenko A,Hellbach K,Bech M,Müller M,Velroyen A,Bamberg F,Eickelberg O,Nikolaou K,Reiser MF,Pfeiffer F,Yildirim AÖ

    更新日期:2014-10-01 00:00:00

  • Comparison of Power Versus Manual Injection in Bolus Shape and Image Quality on Contrast-Enhanced Magnetic Resonance Angiography: An Experimental Study in a Swine Model.

    abstract:OBJECTIVE:The aim of this study was to compare power versus manual injection in bolus shape and image quality on contrast-enhanced magnetic resonance angiography (CE-MRA). MATERIALS AND METHODS:Three types of CE-MRA (head-neck 3-dimensional [3D] MRA with a test-bolus technique, thoracic-abdominal 3D MRA with a bolus-t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000383

    authors: Tsuboyama T,Jost G,Pietsch H,Tomiyama N

    更新日期:2017-09-01 00:00:00

  • Comparison of Iodine Density Measurement Among Dual-Energy Computed Tomography Scanners From 3 Vendors.

    abstract:OBJECTIVES:The aims of this study were to analyze the effect of dual-energy computed tomography (DECT) scanners and fluid characteristics on iodine quantification and to calculate the measurement variability range induced by those variables. METHODS:We performed an experimental phantom study with 4 mediastinal iodine ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000446

    authors: Kim H,Goo JM,Kang CK,Chae KJ,Park CM

    更新日期:2018-06-01 00:00:00

  • Incidence and methods of diagnosis of musculoskeletal injuries incurred in Operations Desert Shield and Desert Storm.

    abstract:RATIONALE AND OBJECTIVES:The authors studied the incidence and distribution of orthopedic injuries sustained in Operation Desert Shield and Desert Storm by evaluating whether existing diagnostic imaging modalities were sufficient to diagnose the types of musculoskeletal injuries incurred. The authors also sought to det...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199703000-00006

    authors: Truax AL,Chandnani VP,Chacko AK,Gonzalez DM

    更新日期:1997-03-01 00:00:00

  • Hepatic parenchymal changes after the intraarterial injection of lipiodol in tumor-bearing rabbits.

    abstract:RATIONALE AND OBJECTIVES:The influence of lipiodol injection on hepatic morphology and function was investigated in 119 rabbits with hepatic VX2 tumors. METHODS:The rabbits were divided into the following three groups, according to the materials injected via the proper hepatic artery: group 1 received doxorubicin (Adr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199302000-00009

    authors: Akashi Y,Koreeda C,Mizuno T,Inoue K,Kawa SK,Tanaka Y

    更新日期:1993-02-01 00:00:00

  • Imaging of complex NMR spectra.

    abstract::The Point Spread Function (PSF) in NMR imaging is the result of both the line broadening due to magnet field inhomogeneity and the intrinsic spectrum of the nucleus at resonance. In the case of proton imaging, the line broadening dominates the small chemical shifts and the spectral lines are not resolved. This is not ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198503000-00016

    authors: Harrison CG,Adams DF,Kramer PB

    更新日期:1985-03-01 00:00:00

  • Myocardial wall motion evaluation using amplitude frequency spectral analysis.

    abstract::Frequency spectral analysis of cardiac wall motion as calculated from the recorded video kymogram are demonstrated. Characteristic harmonics following the fundamental frequency of the cardiac rate have been demonstrated to have an alternating sequential energy distribution as measured from the free margin of the left ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197503000-00005

    authors: Silverman NR,Rosen L,Helland DR

    更新日期:1975-03-01 00:00:00

  • A new class of contrast agents for magnetic resonance imaging based on selective reduction of water-T2 by chemical exchange.

    abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00058

    authors: Aime S,Nano R,Grandi M

    更新日期:1988-09-01 00:00:00

  • Semiquantitative assessment of myocardial perfusion using magnetic resonance imaging: evaluation of appropriate thresholds and segmentation models.

    abstract:RATIONALE AND OBJECTIVES:The aim of the study was to determine optimal thresholds for semiquantitative perfusion parameters and to evaluate the influence of different segmentation models in detecting malperfused regions. MATERIAL AND METHODS:In 6 healthy subjects and 13 patients with coronary artery disease, contrast-...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000133816.83192.38

    authors: Fenchel M,Kramer U,Helber U,Stauder NI,Franow A,Claussen CD,Miller S

    更新日期:2004-09-01 00:00:00

  • Interventional atrioseptostomy by application of monopolar high-frequency alternating current. In vitro evaluation of a new device.

    abstract:RATIONALE AND OBJECTIVES:The authors evaluate the use of a new device for interventional creation of atrial septal defects (ASD) working with high-frequency alternating current in an in vitro study with porcine atria. METHODS:The device consists of a symmetrical cage of six superelastic monofile wires, including a mic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199702000-00003

    authors: Grabitz RG,Handt S,Vanopbroeke HJ,Seghaye MC,Franke A,Osypka P,von Bernuth G

    更新日期:1997-02-01 00:00:00

  • Comparison of 1.5 and 3 T BOLD MR to study oxygenation of kidney cortex and medulla in human renovascular disease.

    abstract:OBJECTIVES:Imaging of the kidney using blood oxygen level dependent MR presents a major opportunity to examine differences in tissue oxygenation within the cortex and medulla applicable to human disease. We sought to define the differences between regions within kidneys and to optimize selection of regions of interest ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181b4c1e8

    authors: Gloviczki ML,Glockner J,Gomez SI,Romero JC,Lerman LO,McKusick M,Textor SC

    更新日期:2009-09-01 00:00:00

  • Evaluation of diffusion-weighted MR imaging at inclusion in an active surveillance protocol for low-risk prostate cancer.

    abstract:PURPOSE:We aimed to determine whether diffusion-weighted magnetic resonance imaging, by means of the apparent diffusion coefficient (ADC), is able to guide magnetic resonance-guided biopsy in patients fit for active surveillance (AS) and identify patients harboring high-grade Gleason components not suitable for AS. MA...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31827b711e

    authors: Somford DM,Hoeks CM,Hulsbergen-van de Kaa CA,Hambrock T,Fütterer JJ,Witjes JA,Bangma CH,Vergunst H,Smits GA,Oddens JR,van Oort IM,Barentsz JO,MR-PRIAS Collaboration Group.

    更新日期:2013-03-01 00:00:00

  • Digital radiography versus conventional radiography for the detection of a skull fracture under varying exposure parameters.

    abstract:RATIONALE AND OBJECTIVES:The effect of varying exposure parameters on the detectability of a fracture with digital and conventional radiography were examined. METHODS:A macerated fractured skull was imaged by film-screen radiography (FSR) and digital storage phosphor radiography (DR) with various exposure values. Five...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199303000-00010

    authors: Langen HJ,Klein HM,Wein B,Schiwy-Bochat KH,Stargardt A,Günther RW

    更新日期:1993-03-01 00:00:00

  • The use of continuous and discrete confidence judgments in receiver operating characteristic studies of diagnostic imaging techniques.

    abstract::Virtually all receiver operating characteristic (ROC) studies of medical imaging methods have involved data collected on a discrete confidence-rating scale, though in principle ROC studies can be conducted with either discrete or continuous scales. Continuous scales provide potential advantages in medical applications...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00016

    authors: Rockette HE,Gur D,Metz CE

    更新日期:1992-02-01 00:00:00

  • Pathophysiology of radiocontrast nephropathy: a role for medullary hypoxia.

    abstract::Recent experimental data underlies the role of hypoxic tubular injury in the pathophysiology of radiocontrast nephropathy. Although systemic transient hypoxemia, increased blood viscosity, and a leftward shift of the oxygen-hemoglobin dissociation curve may all contribute to intrarenal hypoxia, imbalance between oxyge...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199911000-00004

    authors: Heyman SN,Reichman J,Brezis M

    更新日期:1999-11-01 00:00:00

  • Air-filled ultrasound contrast agents do not damage the cerebral microvasculature or brain tissue in rats.

    abstract:RATIONALE AND OBJECTIVES:Air microemboli may damage the cerebral microvasculature. The aim of this study was to evaluate the safety of ultrasound contrast agents composed of air microspheres with regard to cerebral damage when administered into the arterial system (ie, when not filtered by the capillary system of the l...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199803000-00001

    authors: Haggag KJ,Russell D,Walday P,Skiphamn A,Torvik A

    更新日期:1998-03-01 00:00:00

  • The effects of ioxaglate 320, iohexol 350, and iopamidol 370 on erythrocyte aggregation.

    abstract::The authors report a randomized, double-blind prospective trial comparing the effects of nonionic with ionic low-osmolar contrast media on erythrocyte aggregation. The study group comprised 40 consecutive patients with pathology necessitating selective angiography. Patients were examined using either ioxaglate 320, io...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-199108000-00009

    authors: Hayes R,Mahon T,Masterson J,Owens A

    更新日期:1991-08-01 00:00:00

  • Treatment of experimental adenocarcinomas by percutaneous intratumoral injection of absolute ethanol.

    abstract::Percutaneous injection of absolute ethanol into adenocarcinomas implanted in the hind leg of rats was evaluated as a potential cancer treatment. Intramuscular alcohol injections up to 10 mL/kg produced a local dose-dependent coagulation necrosis followed by granulation tissue formation and subsequent fibrosis but no a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198706000-00005

    authors: Burgener FA,Steinmetz SD

    更新日期:1987-06-01 00:00:00