Time continuous tracking and segmentation of cardiovascular magnetic resonance images using multidimensional dynamic programming.

Abstract:

:In this article, we propose a semiautomatic method for time-continuous contour detection in all phases of the cardiac cycle in magnetic resonance sequences. The method is based on multidimensional dynamic programming. After shape parameterization, cost hypercubes are filled with image-feature derived cost function values. Using multidimensional dynamic programming, an optimal path is sought through the sequence of hypercubes. Constraints can be imposed by setting limits to the parameter changes between subsequent hypercubes. Quantitative evaluation was performed on 20 subjects. Average border positioning error over all slices, all phases and all studies, was 1.77 +/- 0.57 mm for epicardial and 1.86 +/- 0.59 mm for endocardial contours. The average error in end-diastolic and end-systolic volumes over all studies was small: 4.24 +/- 4.62 mL and -4.36 +/- 4.26 mL, respectively. The average error in ejection fraction was 4.82 +/- 3.01%. The reported results compare favorable to the best-reported results in recent literature, underlining the potential of this method for application in daily clinical practice.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Uzümcü M,van der Geest RJ,Swingen C,Reiber JH,Lelieveldt BP

doi

10.1097/01.rli.0000194070.88432.24

keywords:

subject

Has Abstract

pub_date

2006-01-01 00:00:00

pages

52-62

issue

1

eissn

0020-9996

issn

1536-0210

pii

00004424-200601000-00008

journal_volume

41

pub_type

杂志文章
  • Ioversol clinical safety summary.

    abstract::The authors evaluated double-blind comparative and open-label clinical trials in 1,186 patients who received ioversol to evaluate the safety and efficacy of ioversol, a new nonionic low-osmolality contrast medium, at iodine concentrations of 32%, 24%, and 16%. The results indicate that ioversol was well tolerated in a...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198906001-00020

    authors: Benamor M,Aten EM,McElvany KD,Lankin DG,James MA,Buy-Gandal T,Harashe LT,Weinandt WJ

    更新日期:1989-06-01 00:00:00

  • Necrotic areas in VX2 carcinoma of rabbits. Correlation of magnetic resonance imaging and pathologic appearance.

    abstract:RATIONALE AND OBJECTIVES:To assess the potential of magnetic resonance imaging (MRI) for evaluating the evolution of tumor necrosis, the authors evaluated 28 VX2 carcinomas inoculated in the thigh muscles of rabbits. METHODS:MRI of VX2 carcinomas at 2.0 T was done with spin-echo technique 1 week (14 tumors) and 3 week...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199301000-00010

    authors: Choi BI,Lee DH,Han MC

    更新日期:1993-01-01 00:00:00

  • BR1: a new ultrasonographic contrast agent based on sulfur hexafluoride-filled microbubbles.

    abstract:RATIONALE AND OBJECTIVES:The basic characteristics of BR1, a novel echo contrast agent based on stabilized sulfur hexafluoride (SF6) microbubbles have been evaluated. METHODS:The authors determined the physicochemical properties (bubble concentration, bubble size distribution, resistance to pressure, and stability) an...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199508000-00001

    authors: Schneider M,Arditi M,Barrau MB,Brochot J,Broillet A,Ventrone R,Yan F

    更新日期:1995-08-01 00:00:00

  • Comprehensive assessment of renal function and vessel morphology in potential living kidney donors: an MRI-based approach.

    abstract:OBJECTIVES:To test the feasibility of a single MR-based examination allowing for the comprehensive assessment of renal anatomy, function, and vascular status in candidates for kidney transplantation. MATERIALS AND METHODS:Twelve healthy potential kidney donors (mean age: 47 +/- 14 [standard deviation] years, 3 men and...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0b013e3181b35a70

    authors: Rossi C,Boss A,Artunc F,Yildiz S,Martirosian P,Dittmann H,Claussen CD,Heyne N,Schick F,Schlemmer HP

    更新日期:2009-11-01 00:00:00

  • Ultrasonic detection of osteomyelitis. Pathologic correlation in an animal model.

    abstract::The authors correlated sonographic findings with histologic findings in a rabbit model of osteomyelitis. Staphylococcus aureus osteomyelitis was induced in the femora of 11 New Zealand white rabbits. The opposite leg was used as a control. Sonographic findings showed fluid adjacent to the bone in 11 cases. The fluid w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199202000-00002

    authors: Abiri MM,DeAngelis GA,Kirpekar M,Abou AN,Ablow RC

    更新日期:1992-02-01 00:00:00

  • Inhibition of restenosis in stented porcine coronary arteries: uptake of Paclitaxel from angiographic contrast media.

    abstract:RATIONALE AND OBJECTIVES:Paclitaxel added to angiographic contrast medium (CM) has been shown to inhibit restenosis in the porcine coronary overstretch model. This study determined early local tissue concentrations after the administration of different paclitaxel doses and preparations. MATERIALS AND METHODS:Fifteen p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000116125.96544.64

    authors: Speck U,Scheller B,Abramjuk C,Grossmann S,Mahnkopf D,Simon O

    更新日期:2004-03-01 00:00:00

  • Contrast-detail phantom study for x-ray spectrum optimization regarding chest radiography using a cesium iodide-amorphous silicon flat-panel detector.

    abstract:RATIONALE AND OBJECTIVES:The purpose of this study evaluating a cesium iodide-amorphous silicon-based flat-panel detector was to optimize the x-ray spectrum for chest radiography combining excellent contrast-detail visibility with reduced patient exposure. MATERIALS AND METHODS:A Lucite plate with 36 drilled holes of ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000138091.96320.f8

    authors: Hamer OW,Völk M,Zorger N,Borisch I,Büttner R,Feuerbach S,Strotzer M

    更新日期:2004-10-01 00:00:00

  • Pancreatic Steatosis Is Associated With Impaired Exocrine Pancreatic Function.

    abstract:OBJECTIVES:The aim of this study was to investigate if pancreatic steatosis measured by proton density fat fraction (PDFF) is associated with exocrine pancreatic function defined by fecal elastase concentrations. MATERIALS AND METHODS:A total of 1458 volunteers (777 women; age range, 21-88 years) underwent magnetic re...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000554

    authors: Kromrey ML,Friedrich N,Hoffmann RT,Bülow R,Völzke H,Weiss FU,Lerch MM,Motosugi U,Kühn JP

    更新日期:2019-07-01 00:00:00

  • Brain tumor enhancement in magnetic resonance imaging: dependency on the level of protein binding of applied contrast agents.

    abstract:PURPOSE:To evaluate the dependency of tumor contrast enhancement (CE) in regard to protein-binding properties of contrast agents, using 4 different agents with a wide range of protein-binding capacities in a standardized rat brain glioma model. MATERIAL AND METHODS:Sixteen rats with implanted brain gliomas were evalua...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318191a334

    authors: Wintersperger BJ,Runge VM,Tweedle MF,Jackson CB,Reiser MF

    更新日期:2009-02-01 00:00:00

  • Response of tumors to therapy studied by 31P magnetic resonance spectroscopy.

    abstract::Magnetic resonance (MR) methods have been used to study the metabolic and vascular response of model tumors to tumor necrosis factor (TNF). Magnetic resonance measurements demonstrated acute reductions in tumor blood flow, measured from tumor uptake of D2O, and in tumor adenosine triphosphate (ATP), measured by 31P ma...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198912000-00022

    authors: Karczmar GS,Meyerhoff DJ,Speder A,Valone F,Wilkinson M,Shine N,Boska MD,Weiner MW

    更新日期:1989-12-01 00:00:00

  • Assessment of cerebral blood flow in man by video dilution technique: a preliminary report.

    abstract::Video dilution technique (VDT) is currently performed in conjunction with routine cerebral angiography to determine carotid blood flow in humans. Preliminary results indicate that the blood flows (as a percentage of cardial output) of the common, internal, and external carotid arteries are 8.5%, 5.5%, and 3.0%, respec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198105000-00004

    authors: Lantz BM,Dublin AB,McGahan JP,Link DP

    更新日期:1981-05-01 00:00:00

  • Magnetic resonance imaging using gadolinium labeled monoclonal antibody.

    abstract::Gadolinium was attached to antibodies and tested in vitro and in vivo for its effect on proton relaxation enhancement. Using the cyclic anhydride method, diethylenetriaminepentaacetic acid (DTPA) was attached to albumin, IgG and anti-CEA monoclonal antibody. Gadolinium (Gd) was then chelated to the protein complexes f...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198510000-00008

    authors: Unger EC,Totty WG,Neufeld DM,Otsuka FL,Murphy WA,Welch MS,Connett JM,Philpott GW

    更新日期:1985-10-01 00:00:00

  • Glucose alters the susceptibility of mesangial cells to contrast media.

    abstract:RATIONALE AND OBJECTIVES:Diabetic patients frequently suffer contrast media-induced nephropathy. Hyperglycemia in diabetes mellitus causes gradual deterioration of glomerular mesangial cells (MCs) in the kidney. In this study, the authors investigated the response of rat MCs cultured in high-glucose medium to diatrizoa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200107000-00001

    authors: Wasaki M,Sugimoto J,Shirota K

    更新日期:2001-07-01 00:00:00

  • Comparative evaluation of digital radiography versus conventional radiography of fractured skulls.

    abstract:OBJECTIVES:The authors assessed the relative efficacy of conventional and digital storage-phosphor radiographs for the detection of skull fractures. METHODS:Fifty conventional film-screen radiographs (FSR) and 50 digital storage-phosphor radiographs (DR) with 66 fractures were compared. Five radiologists evaluated ima...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199308000-00005

    authors: Langen HJ,Klein HM,Wein B,Stargardt A,Günther RW

    更新日期:1993-08-01 00:00:00

  • Low-osmolality contrast media-induced ventricular fibrillation.

    abstract::We evaluated the incidence of ventricular fibrillation with low-osmolality contrast media by right coronary arteriography in eleven adult mongrel dogs. Following insertion of the catheter into the right coronary artery, a test solution was infused for 25 seconds (total 11 mL) or until fibrillation occurred. The test s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198904000-00008

    authors: Hayakawa K,Yamashita K

    更新日期:1989-04-01 00:00:00

  • Evolution of the ablation region after magnetic resonance-guided high-intensity focused ultrasound ablation in a Vx2 tumor model.

    abstract:OBJECTIVES:Volumetric magnetic resonance (MR)-guided high-intensity focused ultrasound (HIFU) is a completely noninvasive image-guided thermal ablation technique. Recently, there has been growing interest in the use of MR-HIFU for noninvasive ablation of malignant tumors. Of particular interest for noninvasive ablation...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182820257

    authors: Wijlemans JW,Deckers R,van den Bosch MA,Seinstra BA,van Stralen M,van Diest PJ,Moonen CT,Bartels LW

    更新日期:2013-06-01 00:00:00

  • Experimental nephrotoxicity of the radiocontrast agents iohexol, ioxaglate, and iothalamate. An in vitro and in vivo study.

    abstract::The authors compared the renal toxicity of the low osmolality radiocontrast agents, iohexol and ioxaglate, and the ionic agent, iothalamate, at equivalent iodine dose, using experimental models in vitro and in vivo. In isolated perfused rat kidneys, all agents induced comparable biphasic hemodynamic changes, associate...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199104000-00008

    authors: Brezis M,Greenfeld Z,Herman M,Meyer JJ,Heyman SN,Rosen S

    更新日期:1991-04-01 00:00:00

  • The effect of certain variables on the tumor and tissue distribution of tracers: VI. False-carrier effect, Part III, Fe.

    abstract::Previous work has shown that Fe3+, when administered in the proper dose and time sequence, increases the tumor uptake of gallium-67 (67Ga) while decreasing its uptake by normal tissues. The purpose of this series of experiments was to examine further the postulate that the false carrier effect is mediated at the cellu...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198207000-00016

    authors: Stern PH,Halpern SE,Hagan PL,Chen A

    更新日期:1982-07-01 00:00:00

  • Potential of dose reduction after marker placement with full-field digital mammography.

    abstract:OBJECTIVES:The purpose of our study was to assess the potential for radiation dose reduction in digital postinterventional digital mammograms after marker placement. MATERIALS AND METHODS:One hundred consecutive cases of marker placement (hook-wire localization or postbiopsy clip marker placement), with 200 full-field...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000163743.63063.9f

    authors: Riedl CC,Jaromi S,Floery D,Pfarl G,Fuchsjaeger MH,Helbich TH

    更新日期:2005-06-01 00:00:00

  • Developments in X-Ray Contrast Media and the Potential Impact on Computed Tomography.

    abstract::Over the past 120 years, continuous developments in medical imaging has improved diagnosis and treatment for many diseases and has thereby improved treatment outcome and quality of life of many patients. The number of computed tomography (CT) examinations is today increasing by 4% per year worldwide, for a total of ap...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000696

    authors: Schöckel L,Jost G,Seidensticker P,Lengsfeld P,Palkowitsch P,Pietsch H

    更新日期:2020-09-01 00:00:00

  • Evaluation of the integrity of the blood-brain barrier after meningeal trauma.

    abstract:RATIONALE AND OBJECTIVES:The authors used magnetic resonance imaging (MRI) techniques to examine the effect of meningeal trauma produced by cisterna magna puncture on the integrity of the blood-cerebrospinal fluid barrier (BCB) in a rat model. METHODS:Intravenous gadolinium-DTPA (Gd-DTPA), a relaxation rate modifier w...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199204000-00008

    authors: Walker JD,Martin MA,Potts DG,Lemaire C,Templeton DM

    更新日期:1992-04-01 00:00:00

  • Ultrahigh-field imaging of the biliary tract at 7 T: initial results of gadoxetic acid-enhanced magnetic resonance cholangiography.

    abstract:OBJECTIVES:The objectives of this study were to assess the feasibility of magnetic resonance cholangiography (MRC) using biliary-secreted gadoxetic acid at 7 T and to compare it with T2-weighted (w) MRC at 3 T. MATERIALS AND METHODS:Ten healthy volunteers were examined on a 7-T whole-body magnetic resonance system. T2...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000004

    authors: Fischer A,Kraff O,Orzada S,Nensa F,Schäfer LC,Ladd ME,Umutlu L,Lauenstein TC

    更新日期:2014-05-01 00:00:00

  • Experimental arterial stent placement. Comparison of a new Nitinol stent and Wallstent.

    abstract:RATIONALE AND OBJECTIVES:To compare technical aspects and neointima formation of a new Nitinol stent and a Wallstent. METHODS:A Nitinol sten and a Wallstent were placed into the iliac arteries of 14 sheep (total of 28 stents) and followed angiographically. Seven sheep were killed after 1 month and 7 after 4.5 months. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199507000-00004

    authors: Schürmann K,Vorwerk D,Kulisch A,Stroehmer-Kulisch E,Biesterfeld S,Stopinski T,Günther RW

    更新日期:1995-07-01 00:00:00

  • The night stalker effect: quality improvements with a dedicated night-call rotation.

    abstract:RATIONALE AND OBJECTIVES:The authors assessed whether a non-sleep-deprived, second-year diagnostic radiology resident assigned to an after-hours "night stalker" emergency radiology (ER) rotation in an urban university hospital has a measurable impact on the number and clinical significance of "missed" radiologic findin...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199301000-00032

    authors: Mann FA,Danz PL

    更新日期:1993-01-01 00:00:00

  • Vein graft-coated stents for endovascular occlusion of canine experimental arteriovenous fistulae.

    abstract:RATIONALE AND OBJECTIVES:To evaluate different vein graft-coated stent systems in the endovascular treatment of experimental arteriovenous fistulae (AVF) in a canine model. METHODS:Bilateral carotid-to-external jugular vein AVF were created. Two balloon-expandable tantalum stents (Strecker stent), two self-expanding n...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199901000-00004

    authors: Schellhammer F,Wahkloo AK,Nagursky H,Schumacher M

    更新日期:1999-01-01 00:00:00

  • Magnetic resonance imaging assays for dimethyl sulfoxide effect on cancer vasculature.

    abstract:OBJECTIVES:To evaluate the potential of quantitative assays of vascular characteristics based on dynamic contrast-enhanced magnetic resonance imaging (MRI) using a macromolecular contrast medium (MMCM) to search for and measure effects of dimethyl sulfoxide (DMSO) on cancer vasculature with microscopic correlations. M...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318164b71d

    authors: Cyran CC,Sennino B,Chaopathomkul B,Fu Y,Rogut V,Shames DM,Wendland MF,McDonald DM,Brasch RC

    更新日期:2008-05-01 00:00:00

  • Right-Angled Traction Bronchiectasis in Differentiating Idiopathic Pulmonary Fibrosis Without Honeycombing From Idiopathic Nonspecific Interstitial Pneumonia.

    abstract:OBJECTIVES:The aim of this study was to conduct a radiopathologic evaluation of right-angled traction bronchiectasis to differentiate idiopathic pulmonary fibrosis (IPF) without honeycombing from idiopathic nonspecific interstitial pneumonia (NSIP). MATERIALS AND METHODS:The derivation cohort included 78 consecutive p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000651

    authors: Kim H,Yoon SH,Lee HJ,Song SG,Koh J,Jeon YK,Chae KJ,Jin GY,Jin KN,Lee KY,Goo JM

    更新日期:2020-06-01 00:00:00

  • Clinical comparison between a currently available single-loop and an investigational dual-channel endorectal receive coil for prostate magnetic resonance imaging: a feasibility study at 1.5 and 3 T.

    abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182a56678

    authors: Vos EK,Sambandamurthy S,Kamel M,McKenney R,van Uden MJ,Hoeks CM,Yakar D,Scheenen TW,Fütterer JJ

    更新日期:2014-01-01 00:00:00

  • Ultrasound Time-Harmonic Elastography of the Pancreas: Reference Values and Clinical Feasibility.

    abstract:OBJECTIVES:Pancreatic ductal adenocarcinoma (PDAC) is a very aggressive tumor with a very low 5-year survival rate of 8%. The aims of this study are to determine reference values and physiologic confounders in healthy pancreas and to assess the diagnostic accuracy of ultrasound time-harmonic elastography (THE) in the d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000638

    authors: Burkhardt C,Tzschätzsch H,Schmuck R,Bahra M,Jürgensen C,Pelzer U,Hamm B,Braun J,Sack I,Marticorena Garcia SR

    更新日期:2020-05-01 00:00:00

  • Can Ferumoxytol be Used as a Contrast Agent to Differentiate Between Acute and Chronic Inflammatory Kidney Disease?: Feasibility Study in a Rat Model.

    abstract:OBJECTIVES:Ferumoxytol, an intravenous iron supplement, can be used in off-label mode as a contrast agent in magnetic resonance imaging. The aim of this study was to assess whether ferumoxytol can be used as a marker of inflammation in animal models of acute and chronic inflammatory kidney diseases. MATERIAL AND METHO...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000209

    authors: Budjan J,Neudecker S,Schock-Kusch D,Kraenzlin B,Schoenberg SO,Michaely HJ,Attenberger UI

    更新日期:2016-02-01 00:00:00