Magnetic resonance imaging in a spinal abscess model. Preliminary report.

Abstract:

RATIONAL AND OBJECTIVES:Magnetic resonance (MR) scan technique and lesion detectability were evaluated using a newly developed spinal abscess model in the New Zealand White rabbit. METHODS:To create the lesion, an epidural needle was inserted under fluoroscopic guidance in the lumbar region and advanced to penetrate the ligamentum flavum. Next, polyethylene tubing was fed through the needle into the epidural space. A mixed suspension of Staphylococcus aureus (Cowan I) and blue polystyrene microspheres then was injected. Lesions were evaluated by MR imaging in four animals at multiple time points (3, 6, and 9 days). Imaging was performed at 1.5 tesla using a surface coil. Precontrast T2-and T1-weighted scans were first obtained. The T1-weighted scans were acquired both with and without fat saturation, and were repeated after intravenous contrast administration. The contrast agent used was gadoteridol (gadolinium HP-DO3A or ProHance) at a dose of 0.3 mmol/kg. RESULTS:On prospective film review, postcontrast scans proved superior for lesion detection. A spinal abscess could be identified postcontrast in all cases, irrespective of the use of fat saturation. The next best imaging technique for lesion detection was the T2-weighted scan, with 5 of 8 lesions noted thereon. Visualization of lesion margins proved to be a primary factor in prospective lesion identification. Region of interest image analysis demonstrated the postcontrast scans to be superior to all precontrast scan techniques for conspicuity of the interface between the abscess and the compressed spinal cord, with these results statistically significant. The lesions were characterized histologically by infiltrates of heterophils into the meninges and outer spinal cord with accompanying mild hemorrhage, fibrin exudation, and bacterial colonies. The lesions in three animals were confirmed to be in the epidural space, with the lesion in one animal in the subdural space. CONCLUSIONS:The current animal model was developed to study spine infection and, specifically, imaging characteristics and lesion detectability on MR. With the increased use of epidural catheters for pain management and the large number of acquired immunodeficiency syndrome cases, epidural infection is becoming an increasingly important clinical problem. Imaging technique, in particular the use of intravenous contrast, is critical for lesion detection and evaluation.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Runge VM,Williams NM,Lee C,Timoney JF

doi

10.1097/00004424-199804000-00008

subject

Has Abstract

pub_date

1998-04-01 00:00:00

pages

246-55

issue

4

eissn

0020-9996

issn

1536-0210

journal_volume

33

pub_type

杂志文章
  • Effects of angiographic needle size and subsequent catheter insertion on arterial walls. An in vitro experiment in human cadavers.

    abstract:RATIONALE AND OBJECTIVES:It is widely believed that down-sizing catheters, and possibly needles, will decrease damage to the entry vessel in the performance of angiography. The purposes of this in vitro experiment are to determine if smaller needles produce less arterial wall damage than larger needles and to assess th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199210000-00001

    authors: Smith DC,Hamlin JA,Jensen DA,Pappas JM,Westengard JC,Saukel GW

    更新日期:1992-10-01 00:00:00

  • Magnetic resonance imaging-guided percutaneous biopsy of mediastinal masses: diagnostic performance and safety.

    abstract:OBJECTIVE:The objective of this study was to evaluate the diagnostic performance and safety of magnetic resonance (MR) imaging-guided percutaneous mediastinal biopsy procedures using a 0.23-T open MR system with optical tracking navigation. MATERIALS AND METHODS:A retrospective analysis of 59 participants (38 males an...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/RLI.0b013e31827a4a17

    authors: Lü Y,Fritz J,Li C,Liu M,Lee P,Wu L,Carrino JA

    更新日期:2013-06-01 00:00:00

  • Evaluation of complex joint motion with computer-based analysis of fluoroscopic sequences.

    abstract:RATIONALE AND OBJECTIVES:To develop a computer-assisted analysis of complex joint motion based on standard fluoroscopic sequences. MATERIALS AND METHODS:Fluoroscopic sequences of 10 normal shoulders and 20 patients after total shoulder arthroplasty were recorded during abduction and adduction. The analysis of the shou...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200202000-00004

    authors: Pfirrmann CW,Huser M,Székely G,Hodler J,Gerber C

    更新日期:2002-02-01 00:00:00

  • Biodistribution and excretion of 125I ioversol in conscious dogs.

    abstract::Radiolabeled ioversol was injected intravenously into two male and two female beagle dogs (6.7 to 10.4 kg) at two dose levels each (0.2 and 1.0 g I/kg). Blood levels of radioactivity were monitored at 2, 5, 10, 20, 40, 60, 90, and 120 minutes and at one and two days. Urine and feces were collected in metabolism cages ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198906001-00005

    authors: Coveney JR,Robbins MS

    更新日期:1989-06-01 00:00:00

  • Evaluation of normal prostate tissue, chronic prostatitis, and prostate cancer by quantitative perfusion analysis using a dynamic contrast-enhanced inversion-prepared dual-contrast gradient echo sequence.

    abstract:OBJECTIVE:To quantify independent pharmacokinetic parameters for differentiation of prostate pathology. MATERIAL AND METHODS:Twenty-seven patients with biopsy-proven prostate cancer (PSA: 1.4-16.1 ng/mL) underwent magnetic resonance imaging with a new dynamic contrast-enhanced, inversion-prepared dual-contrast gradien...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31816b2f63

    authors: Franiel T,Lüdemann L,Rudolph B,Rehbein H,Staack A,Taupitz M,Prochnow D,Beyersdorff D

    更新日期:2008-07-01 00:00:00

  • Free-Breathing Dynamic Contrast-Enhanced Imaging of the Upper Abdomen Using a Cartesian Compressed-Sensing Sequence With Hard-Gated and Motion-State-Resolved Reconstruction.

    abstract:OBJECTIVES:The aim of this study was to compare a compressed-sensing free-breathing VIBE (fbVIBE) with a conventional breath-hold VIBE (bhVIBE) for dynamic contrast-enhanced imaging of the upper abdomen. MATERIALS AND METHODS:In total, 70 datasets (bhVIBE, n = 30; fbVIBE n = 40; hard-gated [hg] reconstruction, n = 30;...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000607

    authors: Hausmann D,Niemann T,Kreul D,Nocito A,Klarhöfer M,Nickel DM,Kiefer B,Attenberger UI,Zöllner FG,Kubik-Huch RA

    更新日期:2019-11-01 00:00:00

  • Ultra-low-dose, time-resolved contrast-enhanced magnetic resonance angiography of the carotid arteries at 3.0 tesla.

    abstract:PURPOSE:To determine whether time-resolved magnetic resonance angiography (TR-MRA) with ultra-low-dose gadolinium chelate (1.5-3.0 mL) can reliably detect or rule out hemodynamically significant disease in the carotid-vertebral artery territory. MATERIALS AND METHODS:Hundred consecutive patients (62 women, 38 men, mea...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31819ca048

    authors: Lohan DG,Tomasian A,Saleh RS,Singhal A,Krishnam MS,Finn JP

    更新日期:2009-04-01 00:00:00

  • Pathophysiology of radiocontrast nephropathy: a role for medullary hypoxia.

    abstract::Recent experimental data underlies the role of hypoxic tubular injury in the pathophysiology of radiocontrast nephropathy. Although systemic transient hypoxemia, increased blood viscosity, and a leftward shift of the oxygen-hemoglobin dissociation curve may all contribute to intrarenal hypoxia, imbalance between oxyge...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-199911000-00004

    authors: Heyman SN,Reichman J,Brezis M

    更新日期:1999-11-01 00:00:00

  • Iopamidol as a gastrointestinal contrast agent. Lack of peritoneal reactivity.

    abstract::The ideal contrast agent in patients suspected of having gastrointestinal perforation is an iso-osmolar, or nearly iso-osmolar substance, that causes no peritoneal reaction. Iopamidol is a nonionic water-soluble contrast medium that may be considered in such situations. Intraperitoneal injections of ionic and nonionic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199002000-00008

    authors: Ferrante SL,Schreiman JS,Rouse JW,Rysavy JA,Cheng SC,Frick MP

    更新日期:1990-02-01 00:00:00

  • Ultrasound analysis of tongue, hyoid, and larynx activity during swallowing.

    abstract::Using real-time ultrasound, the motions of the tongue, hyoid bone, and larynx were monitored and timed during swallowing in ten normal subjects. A well-defined propulsive wave of the tongue was observed during swallowing a 5-cc water bolus. The body of the hyoid bone was identified on the ultrasound scan as a high ech...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198403000-00003

    authors: Shawker TH,Sonies B,Hall TE,Baum BF

    更新日期:1984-03-01 00:00:00

  • Systemic absorption of gallbladder sclerosing agents in the rabbit. A preliminary study.

    abstract::The absorbed levels of ethanol or tetracycline, used as gallbladder sclerosing agents, were measured in the systemic blood circulation of 16 rabbits. The maximal systemic level of ethanol was 46 mg/dl and of tetracycline was 4.6 micrograms/ml after 30 minutes of gallbladder exposure. Comparable serum levels would be c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198605000-00005

    authors: Remley KB,Cubberley DA,Watanabe AS,Nelson JA,Colby TV

    更新日期:1986-05-01 00:00:00

  • The mini-fellowship in teaching. A senior resident elective.

    abstract::The residency program at the University of Pennsylvania offers a 1-month fellowship for senior residents in medical student education. Instructional philosophy, methods, and content are discussed, observed, practiced, and evaluated. Close supervision and immediate feedback provide training particularly needed by futur...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199006000-00028

    authors: Troupin RH

    更新日期:1990-06-01 00:00:00

  • Critical Questions Regarding Gadolinium Deposition in the Brain and Body After Injections of the Gadolinium-Based Contrast Agents, Safety, and Clinical Recommendations in Consideration of the EMA's Pharmacovigilance and Risk Assessment Committee Recommend

    abstract::For magnetic resonance, the established class of intravenous contrast media is the gadolinium-based contrast agents. In the 3 decades since initial approval, these have proven in general to be very safe for human administration. However, in 2006, a devastating late adverse reaction to administration of the less stable...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/RLI.0000000000000374

    authors: Runge VM

    更新日期:2017-06-01 00:00:00

  • Targeted-microbubble binding selectively to GPIIb IIIa receptors of platelet thrombi.

    abstract:RATIONALE AND OBJECTIVES:New targeted microbubbles directed to the GPIIb IIIa receptor have been developed. The objective was to determine whether targeting microbubbles to clots would enhance ultrasound imaging. Systematic studies were designed to determine whether in vitro methodology is an acceptable predictor of in...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200211000-00001

    authors: Schumann PA,Christiansen JP,Quigley RM,McCreery TP,Sweitzer RH,Unger EC,Lindner JR,Matsunaga TO

    更新日期:2002-11-01 00:00:00

  • Mixing problems of low flow hepatic artery infusion. Improvement with small caliber double lumen balloon catheters.

    abstract::The problem of inhomogeneous mixing encountered during hepatic artery (HA) chemotherapy infusion was assessed and a practical solution examined. A glass model of the human HA distribution was used to determine mixing homogeneity of low flow (1.4 mL/minute) dye infusion into pulsatile flow (280-300 mL/minute) of a flui...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198807000-00007

    authors: Barth KH,Lutz RJ,Kremers PW,Miller DL

    更新日期:1988-07-01 00:00:00

  • Effect of inspiratory and expiratory breathhold on pulmonary perfusion: assessment by pulmonary perfusion magnetic resonance imaging.

    abstract:RATIONALE AND OBJECTIVES:The effect of breathholding on pulmonary perfusion remains largely unknown. The aim of this study was to assess the effect of inspiratory and expiratory breathhold on pulmonary perfusion using quantitative pulmonary perfusion magnetic resonance imaging (MRI). METHODS AND RESULTS:Nine healthy v...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000149252.42679.78

    authors: Fink C,Ley S,Risse F,Eichinger M,Zaporozhan J,Buhmann R,Puderbach M,Plathow C,Kauczor HU

    更新日期:2005-02-01 00:00:00

  • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

    abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200207000-00005

    authors: Ropers D,Regenfus M,Stilianakis N,Birke S,Kessler W,Moshage W,Laub G,Daniel WG,Achenbach S

    更新日期:2002-07-01 00:00:00

  • Computerized case-based instructional system for computed tomography and magnetic resonance imaging of brain tumors.

    abstract:RATIONALE AND OBJECTIVES:A computerized system that applies the case-based approach to training radiologists to diagnose brain tumors was designed. The authors attempted to provide residents a tool that supports their visual memory and inducts case-based reasoning. METHODS:A relational database with a digital image li...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199404000-00020

    authors: Macura RT,Macura KJ,Toro VE,Binet EF,Trueblood JH,Ji K

    更新日期:1994-04-01 00:00:00

  • Trabecular bone structure of the distal radius, the calcaneus, and the spine: which site predicts fracture status of the spine best?

    abstract:RATIONALE AND OBJECTIVES:To compare trabecular bone structure measures obtained in magnetic resonance images of the distal radius and the calcaneus as well as computed tomographic images of the spine versus bone mineral density (BMD) of the spine and the calcaneus in the prediction of osteoporotic spine fracture status...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000129154.50654.4e

    authors: Link TM,Bauer J,Kollstedt A,Stumpf I,Hudelmaier M,Settles M,Majumdar S,Lochmüller EM,Eckstein F

    更新日期:2004-08-01 00:00:00

  • Development and evaluation of a phantom for dynamic contrast-enhanced imaging.

    abstract:OBJECTIVES:Dynamic contrast-enhanced imaging allows assessing functional information in addition to morphology using various modalities. Several applications have been established in clinical practice; however, there is no standard with respect to injection protocols or postprocessing algorithms. The purpose of this st...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318250a72c

    authors: Brauweiler R,Eisa F,Hupfer M,Nowak T,Kolditz D,Kalender WA

    更新日期:2012-08-01 00:00:00

  • Ultrasound-guided, percutaneous cryotherapy of small (< or = 15 mm) breast cancers.

    abstract:RATIONALE AND OBJECTIVE:The purpose of this study was to investigate the feasibility, efficacy, and safety of ultrasound-guided percutaneous cryotherapy of stage T1 breast cancers. MATERIALS AND METHODS:Thirty patients with biopsy-confirmed breast cancers with tumor diameters of 15 mm or smaller (range, 5-15 mm; media...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000166935.56971.ff

    authors: Pfleiderer SO,Marx C,Camara O,Gajda M,Kaiser WA

    更新日期:2005-07-01 00:00:00

  • Stability of MRI paramagnetic contrast media: a proton relaxometric protocol for transmetallation assessment.

    abstract:RATIONALE AND OBJECTIVES:The suitability of paramagnetic complexes as magnetic resonance contrast agents depends on various factors such as their relaxivity, stability, selectivity, and the inertness toward transmetallation by endogenous ions. The transmetallation of a series of 18 gadolinium complexes by the Zn2+ ion ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200102000-00008

    authors: Laurent S,Elst LV,Copoix F,Muller RN

    更新日期:2001-02-01 00:00:00

  • Keratinization and necrosis. Morphologic aspects of lymphatic metastases in ultrasound.

    abstract:RATIONALE AND OBJECTIVE:The authors performed a retrospective study in ultrasound to investigate new aspects in the sonomorphology of lymph node metastases of the neck. In this study, it could be demonstrated the first time that the histologic characteristics of the metastases determine the sonographic appearance. In a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199609000-00001

    authors: Mäurer J,Willam C,Steinkamp HJ,Knollmann FD,Felix R

    更新日期:1996-09-01 00:00:00

  • A new class of contrast agents for magnetic resonance imaging based on selective reduction of water-T2 by chemical exchange.

    abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00058

    authors: Aime S,Nano R,Grandi M

    更新日期:1988-09-01 00:00:00

  • AcidoCEST-UTE MRI for the Assessment of Extracellular pH of Joint Tissues at 3 T.

    abstract:OBJECTIVES:The goal of this study was to demonstrate feasibility of measuring extracellular pH in cartilage and meniscus using acidoCEST technique with a 3-dimensional ultrashort echo time readout (acidoCEST-UTE) magnetic resonance imaging (MRI). MATERIALS AND METHODS:Magnetization transfer ratio asymmetry, radiofrequ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000576

    authors: Ma YJ,High RA,Tang Q,Wan L,Jerban S,Du J,Chang EY

    更新日期:2019-09-01 00:00:00

  • Assessment of myocardial viability using delayed enhancement magnetic resonance imaging at 3.0 Tesla.

    abstract:OBJECTIVE:Cardiac magnetic resonance imaging (MRI) at 3.0 T has recently become available and potentially provides a significant improvement of tissue contrast in T1-weighted imaging techniques relying on Gd-based contrast enhancement. Imaging at high-field strength may be especially advantageous for methods relying on...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/01.rli.0000233321.82194.09

    authors: Klumpp B,Fenchel M,Hoevelborn T,Helber U,Scheule A,Claussen C,Miller S

    更新日期:2006-09-01 00:00:00

  • Time course of satisfaction of search.

    abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199107000-00003

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Rooholamini SA,Coffman CE,Cornell SH,Cragg AH,Galvin JR,Honda H,Kao SC

    更新日期:1991-07-01 00:00:00

  • The role of catheters and guidewires in the production of angiographic thromboembolic complications.

    abstract::Thromboembolic complications occurring during angiography may result from a number of different causes. Catheters and guidewires can interact with blood to form thrombi; this tendency is related to wall defects and the chemical composition and structural characteristics of the catheters and guidewires. Nonthrombic sou...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:10.1097/00004424-198811002-00009

    authors: Kido DK,King PD,Manzione JV,Simon JH

    更新日期:1988-11-01 00:00:00

  • Magnetic resonance imaging of acute myocardial infarction using a nitroxyl spin label (PCA).

    abstract::The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed imme...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: McNamara MT,Wesbey GE,Brasch RC,Sievers R,Lipton MJ,Higgins CB

    更新日期:1985-09-01 00:00:00

  • Observation on the metabolism of iopanoyl (Telepaque) glucuronide in dogs treated with antibiotics.

    abstract::The purpose of our investigation was to determine whether iopanoyl glucuronide, the major metabolite of iopanoic acid (Telepaque), undergoes hydrolysis by bacterial beta-glucuronidase in dogs. The conjugated compound was identified and quantitated by elemental analysis, fluorescent excitation analysis, thin-layer chro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197805000-00011

    authors: Thoeni RF,Goldberg HI,Moss AA,Lin SK,Brito AC

    更新日期:1978-05-01 00:00:00