Assessment of myocardial viability using delayed enhancement magnetic resonance imaging at 3.0 Tesla.

Abstract:

OBJECTIVE:Cardiac magnetic resonance imaging (MRI) at 3.0 T has recently become available and potentially provides a significant improvement of tissue contrast in T1-weighted imaging techniques relying on Gd-based contrast enhancement. Imaging at high-field strength may be especially advantageous for methods relying on strong T1-weighting and imaging after contrast material administration. The aim of this study was to compare cardiac delayed enhancement (DE) MRI at 3.0 T and 1.5 T with respect to image quality, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) between infarcted and normal myocardium. MATERIALS AND METHODS:Forty consecutive patients with history of myocardial infarction were examined at 3.0 T (n = 20) or at 1.5 T (n = 20). Myocardial function was assessed using cine steady-state-free-precession (SSFP) sequences (TR 3.1 milliseconds, TE 1.6 milliseconds, flip angle 70 degrees , and a matrix of 168 x 256 at 1.5 T and TR 3.4 milliseconds, TE 1.7 milliseconds, flip angle 50 degrees and a matrix of 168 x 256 at 3.0 T), acquired in long- and short-axes views. DE images were obtained 15 minutes after the administration of 0.15 mmol of Gd-DTPA/kg body weight using a segmented inversion recovery prepared gradient echo sequence at 1.5 T (TR 9.6 milliseconds, TE 4.4 milliseconds, flip angle 25 degrees , matrix 160 x 256, bandwidth 140 Hertz/pixel) and at 3.0 T (TR 9.8 milliseconds, TE 4.3 milliseconds, flip angle 30 degrees , matrix 150 x 256, bandwidth 140 Hertz/pixel). For image analysis, standardized SNR and CNR measurements were performed in infarcted and remote myocardial regions. Two independent observers rated image quality on a 4-point scale (0 = poor image quality, 1 = sufficient image quality, 2 = good image quality, 3 = excellent image quality). RESULTS:High diagnostic image quality was obtained in all patients. Rating of mean image quality was 2.2 +/- 0.8 at 1.5 T and 2.5 +/- 0.6 at 3.0 T (P = 0.012) for observer 1 and 2.2 +/- 0.7 at 1.5 T and 2.6 +/- 0.6 at 3.0 T (P = 0.003) for observer 2, respectively. Interobserver agreement was good (kappa = 0.68 at 1.5 T and 0.78 at 3.0 T). SNR measurements yielded a mean SNR of 37.8 +/- 13.9/22.9 +/- 6.0 in infarcted myocardium (P < 0.001) and 5.6 +/- 2.2/5.9 +/- 2.4 in normal myocardium (P = 0.45) at 3.0 T/1.5 T, respectively. CNR measurements revealed mean values of 32.4 +/- 13.0/16.7 +/- 5.4 (P< 0.001) at 3.0 T/1.5 T, respectively. CONCLUSIONS:Delayed enhancement MRI at 3.0 T is feasible and provides superior image quality compared with 1.5 T. Furthermore, using identical contrast doses, increased SNR and CNR values were recorded at 3.0 T.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Klumpp B,Fenchel M,Hoevelborn T,Helber U,Scheule A,Claussen C,Miller S

doi

10.1097/01.rli.0000233321.82194.09

subject

Has Abstract

pub_date

2006-09-01 00:00:00

pages

661-7

issue

9

eissn

0020-9996

issn

1536-0210

pii

00004424-200609000-00001

journal_volume

41

pub_type

临床试验,杂志文章
  • Comparison of gadobenate dimeglumine with gadopentetate dimeglumine for magnetic resonance imaging of liver tumors.

    abstract:RATIONALE AND OBJECTIVES:To compare gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for magnetic resonance imaging of the liver. METHODS:The contrast agent Gd-BOPTA or Gd-DTPA was administered at a dose of 0.1 mmol/kg to 257 patients suspected of having malignant liver tumors. Dynamic phase ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1097/00004424-200111000-00002

    authors: Kuwatsuru R,Kadoya M,Ohtomo K,Tanimoto A,Hirohashi S,Murakami T,Tanaka Y,Yoshikawa K,Katayama H

    更新日期:2001-11-01 00:00:00

  • In vivo and in vitro evaluation of Gd-DTPA-polylysine as a macromolecular contrast agent for magnetic resonance imaging.

    abstract::Polylysine covalently linked to moieties of gadopentetate (Gd-DTPA), for use as a macromolecular blood pool marker for contrast material-enhanced magnetic resonance imaging (MRI), was characterized by means of physicochemical measurements and pharmacokinetics in rats and rabbits and compared with Gd-DTPA. Gd-DTPA-poly...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199111000-00008

    authors: Schuhmann-Giampieri G,Schmitt-Willich H,Frenzel T,Press WR,Weinmann HJ

    更新日期:1991-11-01 00:00:00

  • Quantification of roughness of calcific deposits in computed tomography scans of human coronary arteries.

    abstract:OBJECTIVES:The incidence of coronary artery disease has been shown to be greater in patients with calcific deposits than in those without. It has been suggested that the pattern of distribution of coronary calcific deposits within coronary arteries is of greater predictive value for acute coronary events than the overa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3180cc2041

    authors: Wilner WT,Mazraeshahi RM,Aboshady I,Bodmann BG,Papadakis M,Kouri D,Conyers JL,Cherukuri P,Vela D,Gladish G,Gavish L,Cody DD,Frazier L,Lukovenkov S,Madjid M,Zarrabi A,Ahmed A,Willerson JT,Casscells SW,Gertz SD

    更新日期:2007-11-01 00:00:00

  • Characteristics of magnetic resonance sequences used for imaging silicone gel, saline, and gel-saline implants at low field strengths.

    abstract:RATIONALE AND OBJECTIVES:Low-field magnetic resonance imaging (MRI) evaluation of breast implants is described, with emphasis on the capabilities provided by different imaging sequences. METHODS:Open architecture MR images using a .064-T permanent magnet and three-dimensional Fourier transform and inversion recovery s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199408000-00009

    authors: Frankel S,Occhipinti K,Kaufman L,Kramer D,Carlson J,Mineyev M,Friedenthal R

    更新日期:1994-08-01 00:00:00

  • Effect of additional cations on the twitching reaction to intracarotid, nonionic contrast media in rabbits.

    abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199009000-00010

    authors: Whisson CC,Evill CA,Sage MR,Wilson AJ

    更新日期:1990-09-01 00:00:00

  • Imaging of complex NMR spectra.

    abstract::The Point Spread Function (PSF) in NMR imaging is the result of both the line broadening due to magnet field inhomogeneity and the intrinsic spectrum of the nucleus at resonance. In the case of proton imaging, the line broadening dominates the small chemical shifts and the spectral lines are not resolved. This is not ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198503000-00016

    authors: Harrison CG,Adams DF,Kramer PB

    更新日期:1985-03-01 00:00:00

  • Short-term effects of a new intravascular nitinol stent in canine arteries.

    abstract:RATIONALE AND OBJECTIVES:To evaluate the short-term effects of a new nitinol stent on canine arteries. METHODS:Eighteen nitinol mesh stents were placed in abdominal aortas, common iliac arteries, and renal arteries of six dogs. Angiography was performed to evaluate the patency rates and structural changes of arteries ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199905000-00007

    authors: Lee KW,Park JH,Chung JW,Kim WS,Lee W,Yeon KM

    更新日期:1999-05-01 00:00:00

  • A Standardized Parameter-Free Algorithm for Combined Intravoxel Incoherent Motion and Diffusion Kurtosis Analysis of Diffusion Imaging Data.

    abstract:OBJECTIVES:The aims of this study were to implement and systematically evaluate the performance of a new parameter-free segmented algorithm for analysis of diffusion imaging data using a combined intravoxel incoherent motion and diffusion kurtosis imaging (IVIM-DKI) model of spin diffusion in comparison with the simple...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000223

    authors: Wurnig MC,Kenkel D,Filli L,Boss A

    更新日期:2016-03-01 00:00:00

  • Binary nature and radiographic identifiability of craniosynostosis.

    abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199410000-00005

    authors: Pilgram TK,Vannier MW,Marsh JL,Kraemer BB,Rayne SC,Gado MH,Moran CJ,McAlister WH,Shackelford GD,Hardesty RA

    更新日期:1994-10-01 00:00:00

  • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

    abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200207000-00005

    authors: Ropers D,Regenfus M,Stilianakis N,Birke S,Kessler W,Moshage W,Laub G,Daniel WG,Achenbach S

    更新日期:2002-07-01 00:00:00

  • Detection of low-contrast signals. A comparison of observers with and without radiology training.

    abstract::Sixteen observers averaging 7.4 years experience in interpreting radiology images and 16 observers without radiology training were tested for their ability to detect low-contrast signals in structured noise backgrounds using a digital display system. No significant difference in true positives, false positives, time t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198704000-00006

    authors: Rackow PL,Spitzer VM,Hendee WR

    更新日期:1987-04-01 00:00:00

  • Educational objectives for diagnostic radiology residency training.

    abstract::A method of teaching radiology residents by identification of general and specific objectives to be accomplished during each time segment of the four-year training program has been developed. The objectives are incorporated into an educational contract that is signed by the resident and rotation director at the beginn...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198612000-00009

    authors: Howland WJ,Marler D,Bosshart D

    更新日期:1986-12-01 00:00:00

  • Value of in vivo T2 measurement for myocardial fibrosis assessment in diabetic mice at 11.75 T.

    abstract:OBJECTIVE:The aim of the study was to assess the value of in vivo T2 measurements to noninvasively quantify myocardial fibrosis in diabetic mice at 11.75 T. Diabetic cardiomyopathy is characterized by extracellular matrix alteration and microcirculation impairment. These conditions might provide electrical heterogeneit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318243e062

    authors: Bun SS,Kober F,Jacquier A,Espinosa L,Kalifa J,Bonzi MF,Kopp F,Lalevee N,Zaffran S,Deharo JC,Cozzone PJ,Bernard M

    更新日期:2012-05-01 00:00:00

  • Right-Angled Traction Bronchiectasis in Differentiating Idiopathic Pulmonary Fibrosis Without Honeycombing From Idiopathic Nonspecific Interstitial Pneumonia.

    abstract:OBJECTIVES:The aim of this study was to conduct a radiopathologic evaluation of right-angled traction bronchiectasis to differentiate idiopathic pulmonary fibrosis (IPF) without honeycombing from idiopathic nonspecific interstitial pneumonia (NSIP). MATERIALS AND METHODS:The derivation cohort included 78 consecutive p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000651

    authors: Kim H,Yoon SH,Lee HJ,Song SG,Koh J,Jeon YK,Chae KJ,Jin GY,Jin KN,Lee KY,Goo JM

    更新日期:2020-06-01 00:00:00

  • Automated calibration in vascular X-ray images using the accurate localization of catheter marker bands.

    abstract:RATIONALE AND OBJECTIVES:To develop a new automated calibration method for vessel measurements in vascular x-ray images. METHODS:Radiopaque marker bands mounted equidistantly on a small catheter were acquired in vitro at five image intensifier (II) sizes in x-ray projection images. The positions of the marker centers ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200004000-00002

    authors: Van Assen HC,Vrooman HA,Egmont-Petersen M,Bosch HG,Koning G,Van Der Linden EL,Goedhart B,Reiber JH

    更新日期:2000-04-01 00:00:00

  • Regional ejection fractions in patients with patent and thrombosed grafts after coronary artery vein bypass surgery.

    abstract::Twenty-six patients who had received 43 grafts were studied before and after coronary artery vein bypass surgery. Cine ventriculograms taken in the right anterior oblique projection were analyzed and regional ejection fractions calculated. Single and multiple grafts were considered separately as were thrombosed and pa...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197705000-00001

    authors: Martin EC,Wixson D,Baltaxe HA

    更新日期:1977-05-01 00:00:00

  • Iopamidol as a gastrointestinal contrast agent. Lack of peritoneal reactivity.

    abstract::The ideal contrast agent in patients suspected of having gastrointestinal perforation is an iso-osmolar, or nearly iso-osmolar substance, that causes no peritoneal reaction. Iopamidol is a nonionic water-soluble contrast medium that may be considered in such situations. Intraperitoneal injections of ionic and nonionic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199002000-00008

    authors: Ferrante SL,Schreiman JS,Rouse JW,Rysavy JA,Cheng SC,Frick MP

    更新日期:1990-02-01 00:00:00

  • Osteosarcoma of the nude rat. A model for experimental magnetic resonance imaging studies of bone tumors.

    abstract::A 144cerium-induced osteosarcoma was transplanted to athymic nude rats (Han:rnu/rnu). Nineteen of the tumor-bearing animals were used to demonstrate the characteristics of the osteosarcoma on magnetic resonance imaging (MRI) in comparison with a group of nine animals that had not received any tumor transplant. The tum...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Witzel JG,Bohndorf K,Prescher A,Adam G

    更新日期:1992-03-01 00:00:00

  • The radiation dosimetry and normal value study of 99mTc-HMPAO-labeled leukocytes.

    abstract:RATIONALE AND OBJECTIVES:Indium-111 (111In)-labeled leukocyte scanning has been used frequently in patients suspected of having infections. Recently, technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) has been used to label leukocytes. This study was undertaken to determine the distribution and dosimetry of 9...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199404000-00010

    authors: Brown ML,Hung JC,Vetter RJ,O'Connor MK,Chowdhury S,Forstrom LA

    更新日期:1994-04-01 00:00:00

  • Vein graft-coated stents for endovascular occlusion of canine experimental arteriovenous fistulae.

    abstract:RATIONALE AND OBJECTIVES:To evaluate different vein graft-coated stent systems in the endovascular treatment of experimental arteriovenous fistulae (AVF) in a canine model. METHODS:Bilateral carotid-to-external jugular vein AVF were created. Two balloon-expandable tantalum stents (Strecker stent), two self-expanding n...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199901000-00004

    authors: Schellhammer F,Wahkloo AK,Nagursky H,Schumacher M

    更新日期:1999-01-01 00:00:00

  • Experimental tissue damage after subcutaneous injection of water soluble contrast media.

    abstract::Various water soluble contrast media (WSCM) were injected subcutaneously into 970 hind feet of 485 rats. Gross morphologic changes were seen after the injection and analyzed as a function of various physicochemical characteristics of WSCM. The WSCM of larger volume, higher osmolality, higher iodine content, and meglum...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199006000-00011

    authors: Kim SH,Park JH,Kim YI,Kim CW,Han MC

    更新日期:1990-06-01 00:00:00

  • Personal computer needs for the radiologist.

    abstract::This article reviews the computer system hardware and software, applications programs, and computer network services that are available on microcomputers for use by the radiologist. The American College of Radiology Institute computer network is described, which is specifically designed to help the practicing radiolog...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198602000-00015

    authors: Newell JD,Hunter TB

    更新日期:1986-02-01 00:00:00

  • The importance of nuclear magnetic relaxation dispersion (NMRD) profiles in MRI contrast media development.

    abstract::Observation of the relaxivity of MRI contrast media over a wide range of magnetic fields is not only necessary for predicting their efficiency at any field but also compulsory for understanding and improving their mechanisms of action. The best experimental approach to this problem is the field cycling method, which a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00047

    authors: Muller RN,Vander Elst L,Rinck PA,Vallet P,Maton F,Fischer H,Roch A,Van Haverbeke Y

    更新日期:1988-09-01 00:00:00

  • Phlebography. Survey and present state.

    abstract::Milestones in the history of phlebography are shortly reviewed. The present state of phlebography with emphasis upon the role of new nonionic contrast media is presented. ...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:

    authors: Enge I

    更新日期:1985-01-01 00:00:00

  • Ultra-low-dose, time-resolved contrast-enhanced magnetic resonance angiography of the carotid arteries at 3.0 tesla.

    abstract:PURPOSE:To determine whether time-resolved magnetic resonance angiography (TR-MRA) with ultra-low-dose gadolinium chelate (1.5-3.0 mL) can reliably detect or rule out hemodynamically significant disease in the carotid-vertebral artery territory. MATERIALS AND METHODS:Hundred consecutive patients (62 women, 38 men, mea...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31819ca048

    authors: Lohan DG,Tomasian A,Saleh RS,Singhal A,Krishnam MS,Finn JP

    更新日期:2009-04-01 00:00:00

  • Assessment of preoperative magnetic resonance imaging staging in patients with hepatocellular carcinoma undergoing resection compared with the seventh American Joint Committee on Cancer System.

    abstract:OBJECTIVES:The aim of this study was to compare the prognostic utility of a staging system using magnetic resonance imaging (MRI) with the seventh American Joint Committee on Cancer (AJCC) staging system in patients with hepatocellular carcinoma (HCC) who underwent hepatic resection. MATERIALS AND METHODS:A total of 1...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182630e8d

    authors: An C,Choi GH,Lee HS,Kim MJ

    更新日期:2012-11-01 00:00:00

  • Toward the Clinical Development and Validation of a Thy1-Targeted Ultrasound Contrast Agent for the Early Detection of Pancreatic Ductal Adenocarcinoma.

    abstract::Early detection of pancreatic ductal adenocarcinoma (PDAC) represents the most significant step toward the treatment of this aggressive lethal disease. Previously, we engineered a preclinical Thy1-targeted microbubble (MBThy1) contrast agent that specifically recognizes Thy1 antigen overexpressed in the vasculature of...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000697

    authors: Bam R,Daryaei I,Abou-Elkacem L,Vilches-Moure JG,Meuillet EJ,Lutz A,Marinelli ER,Unger EC,Gambhir SS,Paulmurugan R

    更新日期:2020-11-01 00:00:00

  • Evaluation of the prostate imaging reporting and data system for the detection of prostate cancer by the results of targeted biopsy of the prostate.

    abstract:PURPOSE:The purpose of this study was to evaluate the magnetic resonance prostate imaging reporting and data system (PI-RADS) for the detection of prostate cancer by the results of magnetic resonance imaging (MRI)-guided biopsy of the prostate as a reference standard. PATIENTS AND METHODS:In 55 patients who had underg...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000030

    authors: Baur AD,Maxeiner A,Franiel T,Kilic E,Huppertz A,Schwenke C,Hamm B,Durmus T

    更新日期:2014-06-01 00:00:00

  • Magnetization Transfer Imaging Predicts Porcine Kidney Recovery After Revascularization of Renal Artery Stenosis.

    abstract:MATERIALS AND METHODS:Stenotic kidney (STK) and contralateral kidney magnetization transfer ratios (MTRs; Mt/M0) were measured at 3.0-T magnetic resonance imaging, at offset frequencies of 600 and 1000 Hz, before and 1 month post-PTRA in 7 RVD pigs. Stenotic kidney MTR was correlated to renal perfusion, renal blood flo...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000711

    authors: Afarideh M,Jiang K,Ferguson CM,Woollard JR,Glockner JF,Lerman LO

    更新日期:2021-02-01 00:00:00

  • A new class of contrast agents for magnetic resonance imaging based on selective reduction of water-T2 by chemical exchange.

    abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198809001-00058

    authors: Aime S,Nano R,Grandi M

    更新日期:1988-09-01 00:00:00