Three-dimensional cerebral contrast-enhanced magnetic resonance venography at 3.0 Tesla: initial results using highly accelerated parallel acquisition.

Abstract:

OBJECTIVE:The objective of this study was to evaluate a high spatial resolution 3-dimensional (3D) contrast-enhanced magnetic resonance (CE-MR) venography protocol for evaluation of intracranial venous system using highly accelerated parallel imaging at 3.0 T. MATERIALS AND METHODS:Ten patients (4 male, 6 female; age, 38-76 years) with suspected cerebrovascular disease were prospectively studied on a 32-channel 3.0 T MR system. After a single intravenous contrast injection, high spatial resolution 3D CE-MR angiography of the entire supraaortic arteries was performed followed immediately by 3D cerebral CE-MR venography. By using a fast 3D gradient-recalled-echo sequence with elliptic centric k-space ordering and highly accelerated parallel acquisition (acceleration factor 3 and 2 in phase and slice encoding direction, respectively), 3D cerebral CE-MR venography was acquired with voxel dimensions of 0.7 x 0.7 x 0.8 mm in 24 seconds. Image evaluation was performed independently by 2 neuroradiologists for overall image quality, presence of noise, and artifacts. The image quality of 30 venous segments was evaluated in each subject using a 1 to 4 scoring scale. In 2 patients, catheter angiography was available for correlation. Statistical analysis of data was performed by using Wilcoxon rank sum test and kappa coefficient. RESULTS:All studies were determined to be of diagnostic image quality by both observers. The majority (90%) of cerebral venous segments were evaluated to be of diagnostic image quality (median, 3; range, 3-4) by both readers and with excellent interobserver agreement (kappa = 0.86; 95% confidence interval, 0.79-0.93). One meningioma invading the superior sagittal sinus and one superior sagittal sinus fistula were detected subsequently confirmed by conventional angiography. CONCLUSION:High spatial resolution 3D cerebral CE-MR venography is feasible and promising. Using a 32-channel 3.0 T system combined with multichannel array coils effectively supports highly accelerated parallel imaging, enabling subsequent acquisition of both high spatial resolution CE-MR angiography and CE-MR venography after a single contrast injection without impairing the image quality. More extensive clinical studies are warranted to establish the range of applications and confirm the accuracy of this technique.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Nael K,Fenchel M,Salamon N,Duckwiler GR,Laub G,Finn JP,Villablanca JP

doi

10.1097/01.rli.0000236992.21065.04

subject

Has Abstract

pub_date

2006-10-01 00:00:00

pages

763-8

issue

10

eissn

0020-9996

issn

1536-0210

pii

00004424-200610000-00007

journal_volume

41

pub_type

临床试验,杂志文章
  • Human brain chemical shift imaging at age 60 to 90: analysis of the causes of the observed sex differences in brain metabolites.

    abstract:RATIONALE AND OBJECTIVES:To assess whether differences in cerebral atrophy and white matter lesions or in the presence of lactate and lipid signals can explain the observed differences in brain choline, creatine, and N-acetylaspartate levels between healthy elderly women and men. METHODS:In addition to standard magnet...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200110000-00005

    authors: Sijens PE,Den Heijer T,De Leeuw FE,De Groot JC,Achten E,Heijboer RJ,Hofman A,Breteler MM,Oudkerk M

    更新日期:2001-10-01 00:00:00

  • Extravascular extravasation of radiographic contrast media. Effects of conventional and low-osmolar agents in the rat thigh.

    abstract::We compared the damage resulting from intradermal injection of four commonly used radiographic contrast media in laboratory rats. Sixty percent meglumine diatrizoate (Reno M 60) and ioxaglate (Hexabrix) produced significantly more ulceration and crusting on gross inspection and more necrosis, edema, and hemorrhage on ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199005000-00006

    authors: Cohan RH,Leder RA,Bolick D,Herzberg AJ,Hedlund LW,Wheeler CT,Helms MJ,Dunnick NR

    更新日期:1990-05-01 00:00:00

  • Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck: First In Vivo Human Results.

    abstract:PURPOSE:The purpose of this study was to evaluate image quality of a spectral photon-counting detector (PCD) computed tomography (CT) system for evaluation of major arteries of the head and neck compared with conventional single-energy CT scans using energy-integrating detectors (EIDs). METHODS:In this institutional r...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000418

    authors: Symons R,Reich DS,Bagheri M,Cork TE,Krauss B,Ulzheimer S,Kappler S,Bluemke DA,Pourmorteza A

    更新日期:2018-03-01 00:00:00

  • Magnetic resonance imaging in a spinal abscess model. Preliminary report.

    abstract:RATIONAL AND OBJECTIVES:Magnetic resonance (MR) scan technique and lesion detectability were evaluated using a newly developed spinal abscess model in the New Zealand White rabbit. METHODS:To create the lesion, an epidural needle was inserted under fluoroscopic guidance in the lumbar region and advanced to penetrate t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199804000-00008

    authors: Runge VM,Williams NM,Lee C,Timoney JF

    更新日期:1998-04-01 00:00:00

  • Phantom testing of peripheral artery. Absolute blood flow measurement with digital arteriography.

    abstract::A technique to measure absolute arterial blood flow in ml/min has been developed utilizing software programs with high-speed digital recording for the off-line analysis of intra-arterial injections of contrast medium. Measurements of pulsatile flow in a phantom for a physical flow model showed that calculations with t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198503000-00017

    authors: Forbes G,Gray JE,Felmlee JP

    更新日期:1985-03-01 00:00:00

  • Constructing pre- and post-tests in a medical student elective.

    abstract::The importance of evaluating medical student performance has been widely addressed in the medical education literature. Multiple-choice examinations are the preferred method of testing because they are easy to administer and score. Development of parallel or equivalent pre- and post-examinations provides objective inf...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Blane CE,Calhoun JG,Vydareny KH

    更新日期:1986-09-01 00:00:00

  • The detection of inflammation in collapsed lung by alterations in proton nuclear magnetic relaxation times.

    abstract::The purpose of this study was to establish the proton NMR relaxation times of collapsed but otherwise normal lung tissue and to determine whether an inflammatory process within a collapsed lung can be detected by alterations in relaxation times. The lungs of three groups of rabbits were studied: group A (n = 7) had a ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198508000-00004

    authors: Huber DJ,Kobzik L,Melanson G,Adams DF

    更新日期:1985-08-01 00:00:00

  • Automated calibration in vascular X-ray images using the accurate localization of catheter marker bands.

    abstract:RATIONALE AND OBJECTIVES:To develop a new automated calibration method for vessel measurements in vascular x-ray images. METHODS:Radiopaque marker bands mounted equidistantly on a small catheter were acquired in vitro at five image intensifier (II) sizes in x-ray projection images. The positions of the marker centers ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200004000-00002

    authors: Van Assen HC,Vrooman HA,Egmont-Petersen M,Bosch HG,Koning G,Van Der Linden EL,Goedhart B,Reiber JH

    更新日期:2000-04-01 00:00:00

  • Detection of low-contrast signals. A comparison of observers with and without radiology training.

    abstract::Sixteen observers averaging 7.4 years experience in interpreting radiology images and 16 observers without radiology training were tested for their ability to detect low-contrast signals in structured noise backgrounds using a digital display system. No significant difference in true positives, false positives, time t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198704000-00006

    authors: Rackow PL,Spitzer VM,Hendee WR

    更新日期:1987-04-01 00:00:00

  • A closed-chest pulmonary artery occlusion/reperfusion model in the pig: detection of experimental pulmonary embolism with MR angiography and perfusion MR imaging.

    abstract:RATIONALE AND OBJECTIVES:To establish a pig model suitable for imitating pulmonary emboli to facilitate research in the diagnosis of pulmonary embolism. METHODS:Thirteen animals were anesthetized, mechanically ventilated, and subjected to pulmonary artery catheterization initiated from the right external jugular vein....

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200005000-00003

    authors: Amundsen T,Kvaerness J,Aadahl P,Waage A,Bjermer L,Odegård A,Haraldseth O

    更新日期:2000-05-01 00:00:00

  • Observation on the metabolism of iopanoyl (Telepaque) glucuronide in dogs treated with antibiotics.

    abstract::The purpose of our investigation was to determine whether iopanoyl glucuronide, the major metabolite of iopanoic acid (Telepaque), undergoes hydrolysis by bacterial beta-glucuronidase in dogs. The conjugated compound was identified and quantitated by elemental analysis, fluorescent excitation analysis, thin-layer chro...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197805000-00011

    authors: Thoeni RF,Goldberg HI,Moss AA,Lin SK,Brito AC

    更新日期:1978-05-01 00:00:00

  • Magnetic resonance imaging of acute myocardial infarction using a nitroxyl spin label (PCA).

    abstract::The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed imme...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: McNamara MT,Wesbey GE,Brasch RC,Sievers R,Lipton MJ,Higgins CB

    更新日期:1985-09-01 00:00:00

  • Microangiographic anatomy of the cat's eye.

    abstract::The microangiographic anatomy of the cat's eye is presented. The characteristic vascular pattern of each of the three distinct circulations, retinal choroidal, and ciliary is described and illustrated. ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-197501000-00007

    authors: Rothman SL,Kier EL,Deuker DK

    更新日期:1975-01-01 00:00:00

  • Experimental renal papillary necrosis in rats: microangiographic and tubular micropuncture injection studies.

    abstract::Proposed causes of renal papillary necrosis (RPN) include tubular toxicity due to hyperconcentration of toxins in the renal medulla and vasoconstriction of medullary vessels with ischemic necrosis. The authors studied these mechanisms in bromoethylamine hydrobromide-induced RPN in rats by microvascular and tubular mic...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198103000-00006

    authors: Cuttino JT Jr,Goss FU,Clark RL,Marr MC

    更新日期:1981-03-01 00:00:00

  • Ultrasound analysis of tongue, hyoid, and larynx activity during swallowing.

    abstract::Using real-time ultrasound, the motions of the tongue, hyoid bone, and larynx were monitored and timed during swallowing in ten normal subjects. A well-defined propulsive wave of the tongue was observed during swallowing a 5-cc water bolus. The body of the hyoid bone was identified on the ultrasound scan as a high ech...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198403000-00003

    authors: Shawker TH,Sonies B,Hall TE,Baum BF

    更新日期:1984-03-01 00:00:00

  • Model-based iterative reconstruction technique for ultralow-dose computed tomography of the lung: a pilot study.

    abstract:OBJECTIVES:The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. MATERIALS AND METHODS:The institutional review board approved this study, and all patients pr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182562a89

    authors: Yamada Y,Jinzaki M,Tanami Y,Shiomi E,Sugiura H,Abe T,Kuribayashi S

    更新日期:2012-08-01 00:00:00

  • Time course of satisfaction of search.

    abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199107000-00003

    authors: Berbaum KS,Franken EA Jr,Dorfman DD,Rooholamini SA,Coffman CE,Cornell SH,Cragg AH,Galvin JR,Honda H,Kao SC

    更新日期:1991-07-01 00:00:00

  • Osteosarcoma of the nude rat. A model for experimental magnetic resonance imaging studies of bone tumors.

    abstract::A 144cerium-induced osteosarcoma was transplanted to athymic nude rats (Han:rnu/rnu). Nineteen of the tumor-bearing animals were used to demonstrate the characteristics of the osteosarcoma on magnetic resonance imaging (MRI) in comparison with a group of nine animals that had not received any tumor transplant. The tum...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Witzel JG,Bohndorf K,Prescher A,Adam G

    更新日期:1992-03-01 00:00:00

  • The clotting issue: etiologic factors in thromboembolism. II. Clinical considerations.

    abstract:RATIONALE AND OBJECTIVES:The authors analyze the origins of the "clotting issue," the controversy that began in the 1980s when contrast media, once perceived as good flushing agents for catheters because of their assumed anticoagulant properties, came under attack for allegedly causing thromboembolism. Laboratory studi...

    journal_title:Investigative radiology

    pub_type: 杂志文章,评审

    doi:

    authors: Dawson P,Cousins C,Bradshaw A

    更新日期:1993-11-01 00:00:00

  • Observer variation in abdominal CT.

    abstract::Observer performance in radiologic interpretation has traditionally been based upon Receiver Operating Characteristic (ROC) analysis. A statistical method that evaluates the reproducibility or consistency of radiologic interpretation is presented. Since this method is not based upon pathologic verification, it cannot ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198411000-00024

    authors: Herman S,DeBoer G,Rideout DF,Majesky IF

    更新日期:1984-11-01 00:00:00

  • Pharmacokinetics and safety of iomeprol in healthy volunteers and in patients with renal impairment or end-stage renal disease requiring hemodialysis.

    abstract:RATIONALE AND OBJECTIVES:To present the results of two studies conducted to evaluate the pharmacokinetics and safety of iomeprol in healthy volunteers and in patients with various degrees of renal impairment. METHODS:In these two open-label, single-dose, phase I studies, a 50-mL dose of iomeprol 400 was administered i...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-200106000-00002

    authors: Lorusso V,Taroni P,Alvino S,Spinazzi A

    更新日期:2001-06-01 00:00:00

  • Whole-body diffusion-weighted imaging with apparent diffusion coefficient mapping for treatment response assessment in patients with diffuse large B-cell lymphoma: pilot study.

    abstract:OBJECTIVES:The aim of this pilot study was to assess post-treatment apparent diffusion coefficient (ADC) changes of diffuse large B-cell lymphoma lesions on respiratory-gated whole-body diffusion-weighted imaging (DWI), with integrated (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182087b03

    authors: Lin C,Itti E,Luciani A,Zegai B,Lin SJ,Kuhnowski F,Pigneur F,Gaillard I,Paone G,Meignan M,Haioun C,Rahmouni A

    更新日期:2011-05-01 00:00:00

  • The General Electric-Association of University Radiologists Radiology Research Academic Fellowship (GERRAF). An industry-academic collaboration to improve clinical research in radiology.

    abstract::The association of GE Medical Systems and the AUR represents a unique collaboration between academic radiology and industry that bears important potential for elevating the quality of clinical research in radiology and developing a cadre of high-quality radiologist researchers for the future. The establishment of the ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199305000-00001

    authors: Hillman BJ,Fryback DG,Holden RW,McNeil BJ,Molitor RM,Moss AA,Peck PV,Putman CE,Thompson WM

    更新日期:1993-05-01 00:00:00

  • The night stalker effect: quality improvements with a dedicated night-call rotation.

    abstract:RATIONALE AND OBJECTIVES:The authors assessed whether a non-sleep-deprived, second-year diagnostic radiology resident assigned to an after-hours "night stalker" emergency radiology (ER) rotation in an urban university hospital has a measurable impact on the number and clinical significance of "missed" radiologic findin...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199301000-00032

    authors: Mann FA,Danz PL

    更新日期:1993-01-01 00:00:00

  • Ioversol clinical safety summary.

    abstract::The authors evaluated double-blind comparative and open-label clinical trials in 1,186 patients who received ioversol to evaluate the safety and efficacy of ioversol, a new nonionic low-osmolality contrast medium, at iodine concentrations of 32%, 24%, and 16%. The results indicate that ioversol was well tolerated in a...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198906001-00020

    authors: Benamor M,Aten EM,McElvany KD,Lankin DG,James MA,Buy-Gandal T,Harashe LT,Weinandt WJ

    更新日期:1989-06-01 00:00:00

  • Time continuous tracking and segmentation of cardiovascular magnetic resonance images using multidimensional dynamic programming.

    abstract::In this article, we propose a semiautomatic method for time-continuous contour detection in all phases of the cardiac cycle in magnetic resonance sequences. The method is based on multidimensional dynamic programming. After shape parameterization, cost hypercubes are filled with image-feature derived cost function val...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000194070.88432.24

    authors: Uzümcü M,van der Geest RJ,Swingen C,Reiber JH,Lelieveldt BP

    更新日期:2006-01-01 00:00:00

  • Effect of Age on High T1 Signal Intensity of the Dentate Nucleus and Globus Pallidus in a Large Population Exposed to Gadodiamide.

    abstract:OBJECTIVE:The purpose of this study was to assess the effect of age and number of previous injections of gadodiamide on the signal intensity of unenhanced T1-weighted (T1w) images of the dentate nucleus and globus pallidus in a large population. MATERIALS AND METHODS:A large, single-center retrospective population sur...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000431

    authors: Quattrocchi CC,Errante Y,Mallio CA,Marinelli L,LoVullo G,Giannotti G,Della Sala SW,van der Molen AJ,Beomonte Zobel B

    更新日期:2018-04-01 00:00:00

  • Fibroblast response to gadolinium: role for platelet-derived growth factor receptor.

    abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3181e943d2

    authors: Bhagavathula N,Dame MK,DaSilva M,Jenkins W,Aslam MN,Perone P,Varani J

    更新日期:2010-12-01 00:00:00

  • High resolution sonography of the menisci of the knee.

    abstract::High-resolution real-time ultrasonography (5, 7.5, and 10 MHz) was used to examine the menisci of the knee in ten normal volunteers and in ten patients with knee injuries. The posterior horns of the medial and lateral menisci were easily demonstrated. Normal anatomy and pathologic changes could be imaged in the menisc...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198604000-00008

    authors: Selby B,Richardson ML,Montana MA,Teitz CC,Larson RV,Mack LA

    更新日期:1986-04-01 00:00:00

  • Magnetic resonance imaging using gadolinium labeled monoclonal antibody.

    abstract::Gadolinium was attached to antibodies and tested in vitro and in vivo for its effect on proton relaxation enhancement. Using the cyclic anhydride method, diethylenetriaminepentaacetic acid (DTPA) was attached to albumin, IgG and anti-CEA monoclonal antibody. Gadolinium (Gd) was then chelated to the protein complexes f...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198510000-00008

    authors: Unger EC,Totty WG,Neufeld DM,Otsuka FL,Murphy WA,Welch MS,Connett JM,Philpott GW

    更新日期:1985-10-01 00:00:00