Abstract:
OBJECTIVE:The objective of this study was to evaluate a high spatial resolution 3-dimensional (3D) contrast-enhanced magnetic resonance (CE-MR) venography protocol for evaluation of intracranial venous system using highly accelerated parallel imaging at 3.0 T. MATERIALS AND METHODS:Ten patients (4 male, 6 female; age, 38-76 years) with suspected cerebrovascular disease were prospectively studied on a 32-channel 3.0 T MR system. After a single intravenous contrast injection, high spatial resolution 3D CE-MR angiography of the entire supraaortic arteries was performed followed immediately by 3D cerebral CE-MR venography. By using a fast 3D gradient-recalled-echo sequence with elliptic centric k-space ordering and highly accelerated parallel acquisition (acceleration factor 3 and 2 in phase and slice encoding direction, respectively), 3D cerebral CE-MR venography was acquired with voxel dimensions of 0.7 x 0.7 x 0.8 mm in 24 seconds. Image evaluation was performed independently by 2 neuroradiologists for overall image quality, presence of noise, and artifacts. The image quality of 30 venous segments was evaluated in each subject using a 1 to 4 scoring scale. In 2 patients, catheter angiography was available for correlation. Statistical analysis of data was performed by using Wilcoxon rank sum test and kappa coefficient. RESULTS:All studies were determined to be of diagnostic image quality by both observers. The majority (90%) of cerebral venous segments were evaluated to be of diagnostic image quality (median, 3; range, 3-4) by both readers and with excellent interobserver agreement (kappa = 0.86; 95% confidence interval, 0.79-0.93). One meningioma invading the superior sagittal sinus and one superior sagittal sinus fistula were detected subsequently confirmed by conventional angiography. CONCLUSION:High spatial resolution 3D cerebral CE-MR venography is feasible and promising. Using a 32-channel 3.0 T system combined with multichannel array coils effectively supports highly accelerated parallel imaging, enabling subsequent acquisition of both high spatial resolution CE-MR angiography and CE-MR venography after a single contrast injection without impairing the image quality. More extensive clinical studies are warranted to establish the range of applications and confirm the accuracy of this technique.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Nael K,Fenchel M,Salamon N,Duckwiler GR,Laub G,Finn JP,Villablanca JPdoi
10.1097/01.rli.0000236992.21065.04subject
Has Abstractpub_date
2006-10-01 00:00:00pages
763-8issue
10eissn
0020-9996issn
1536-0210pii
00004424-200610000-00007journal_volume
41pub_type
临床试验,杂志文章abstract:RATIONALE AND OBJECTIVES:To assess whether differences in cerebral atrophy and white matter lesions or in the presence of lactate and lipid signals can explain the observed differences in brain choline, creatine, and N-acetylaspartate levels between healthy elderly women and men. METHODS:In addition to standard magnet...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200110000-00005
更新日期:2001-10-01 00:00:00
abstract::We compared the damage resulting from intradermal injection of four commonly used radiographic contrast media in laboratory rats. Sixty percent meglumine diatrizoate (Reno M 60) and ioxaglate (Hexabrix) produced significantly more ulceration and crusting on gross inspection and more necrosis, edema, and hemorrhage on ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199005000-00006
更新日期:1990-05-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate image quality of a spectral photon-counting detector (PCD) computed tomography (CT) system for evaluation of major arteries of the head and neck compared with conventional single-energy CT scans using energy-integrating detectors (EIDs). METHODS:In this institutional r...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000418
更新日期:2018-03-01 00:00:00
abstract:RATIONAL AND OBJECTIVES:Magnetic resonance (MR) scan technique and lesion detectability were evaluated using a newly developed spinal abscess model in the New Zealand White rabbit. METHODS:To create the lesion, an epidural needle was inserted under fluoroscopic guidance in the lumbar region and advanced to penetrate t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199804000-00008
更新日期:1998-04-01 00:00:00
abstract::A technique to measure absolute arterial blood flow in ml/min has been developed utilizing software programs with high-speed digital recording for the off-line analysis of intra-arterial injections of contrast medium. Measurements of pulsatile flow in a phantom for a physical flow model showed that calculations with t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198503000-00017
更新日期:1985-03-01 00:00:00
abstract::The importance of evaluating medical student performance has been widely addressed in the medical education literature. Multiple-choice examinations are the preferred method of testing because they are easy to administer and score. Development of parallel or equivalent pre- and post-examinations provides objective inf...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1986-09-01 00:00:00
abstract::The purpose of this study was to establish the proton NMR relaxation times of collapsed but otherwise normal lung tissue and to determine whether an inflammatory process within a collapsed lung can be detected by alterations in relaxation times. The lungs of three groups of rabbits were studied: group A (n = 7) had a ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198508000-00004
更新日期:1985-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To develop a new automated calibration method for vessel measurements in vascular x-ray images. METHODS:Radiopaque marker bands mounted equidistantly on a small catheter were acquired in vitro at five image intensifier (II) sizes in x-ray projection images. The positions of the marker centers ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200004000-00002
更新日期:2000-04-01 00:00:00
abstract::Sixteen observers averaging 7.4 years experience in interpreting radiology images and 16 observers without radiology training were tested for their ability to detect low-contrast signals in structured noise backgrounds using a digital display system. No significant difference in true positives, false positives, time t...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198704000-00006
更新日期:1987-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To establish a pig model suitable for imitating pulmonary emboli to facilitate research in the diagnosis of pulmonary embolism. METHODS:Thirteen animals were anesthetized, mechanically ventilated, and subjected to pulmonary artery catheterization initiated from the right external jugular vein....
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200005000-00003
更新日期:2000-05-01 00:00:00
abstract::The purpose of our investigation was to determine whether iopanoyl glucuronide, the major metabolite of iopanoic acid (Telepaque), undergoes hydrolysis by bacterial beta-glucuronidase in dogs. The conjugated compound was identified and quantitated by elemental analysis, fluorescent excitation analysis, thin-layer chro...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197805000-00011
更新日期:1978-05-01 00:00:00
abstract::The effects of an intravenously administered nitroxyl spin label (PCA) on the magnetic resonance imaging (MRI) appearance and relaxation times of acute canine myocardial infarctions were studied. Twenty-four hours after ligation of the left anterior descending coronary artery (LAD), animals were either sacrificed imme...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1985-09-01 00:00:00
abstract::The microangiographic anatomy of the cat's eye is presented. The characteristic vascular pattern of each of the three distinct circulations, retinal choroidal, and ciliary is described and illustrated. ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197501000-00007
更新日期:1975-01-01 00:00:00
abstract::Proposed causes of renal papillary necrosis (RPN) include tubular toxicity due to hyperconcentration of toxins in the renal medulla and vasoconstriction of medullary vessels with ischemic necrosis. The authors studied these mechanisms in bromoethylamine hydrobromide-induced RPN in rats by microvascular and tubular mic...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198103000-00006
更新日期:1981-03-01 00:00:00
abstract::Using real-time ultrasound, the motions of the tongue, hyoid bone, and larynx were monitored and timed during swallowing in ten normal subjects. A well-defined propulsive wave of the tongue was observed during swallowing a 5-cc water bolus. The body of the hyoid bone was identified on the ultrasound scan as a high ech...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198403000-00003
更新日期:1984-03-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to assess the effectiveness of a model-based iterative reconstruction (MBIR) in improving image quality and diagnostic performance of ultralow-dose computed tomography (ULDCT) of the lung. MATERIALS AND METHODS:The institutional review board approved this study, and all patients pr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182562a89
更新日期:2012-08-01 00:00:00
abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199107000-00003
更新日期:1991-07-01 00:00:00
abstract::A 144cerium-induced osteosarcoma was transplanted to athymic nude rats (Han:rnu/rnu). Nineteen of the tumor-bearing animals were used to demonstrate the characteristics of the osteosarcoma on magnetic resonance imaging (MRI) in comparison with a group of nine animals that had not received any tumor transplant. The tum...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1992-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors analyze the origins of the "clotting issue," the controversy that began in the 1980s when contrast media, once perceived as good flushing agents for catheters because of their assumed anticoagulant properties, came under attack for allegedly causing thromboembolism. Laboratory studi...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:
更新日期:1993-11-01 00:00:00
abstract::Observer performance in radiologic interpretation has traditionally been based upon Receiver Operating Characteristic (ROC) analysis. A statistical method that evaluates the reproducibility or consistency of radiologic interpretation is presented. Since this method is not based upon pathologic verification, it cannot ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198411000-00024
更新日期:1984-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To present the results of two studies conducted to evaluate the pharmacokinetics and safety of iomeprol in healthy volunteers and in patients with various degrees of renal impairment. METHODS:In these two open-label, single-dose, phase I studies, a 50-mL dose of iomeprol 400 was administered i...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/00004424-200106000-00002
更新日期:2001-06-01 00:00:00
abstract:OBJECTIVES:The aim of this pilot study was to assess post-treatment apparent diffusion coefficient (ADC) changes of diffuse large B-cell lymphoma lesions on respiratory-gated whole-body diffusion-weighted imaging (DWI), with integrated (18)F-fluoro-2-deoxyglucose positron emission tomography/computed tomography (PET/CT...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182087b03
更新日期:2011-05-01 00:00:00
abstract::The association of GE Medical Systems and the AUR represents a unique collaboration between academic radiology and industry that bears important potential for elevating the quality of clinical research in radiology and developing a cadre of high-quality radiologist researchers for the future. The establishment of the ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199305000-00001
更新日期:1993-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors assessed whether a non-sleep-deprived, second-year diagnostic radiology resident assigned to an after-hours "night stalker" emergency radiology (ER) rotation in an urban university hospital has a measurable impact on the number and clinical significance of "missed" radiologic findin...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199301000-00032
更新日期:1993-01-01 00:00:00
abstract::The authors evaluated double-blind comparative and open-label clinical trials in 1,186 patients who received ioversol to evaluate the safety and efficacy of ioversol, a new nonionic low-osmolality contrast medium, at iodine concentrations of 32%, 24%, and 16%. The results indicate that ioversol was well tolerated in a...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/00004424-198906001-00020
更新日期:1989-06-01 00:00:00
abstract::In this article, we propose a semiautomatic method for time-continuous contour detection in all phases of the cardiac cycle in magnetic resonance sequences. The method is based on multidimensional dynamic programming. After shape parameterization, cost hypercubes are filled with image-feature derived cost function val...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000194070.88432.24
更新日期:2006-01-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to assess the effect of age and number of previous injections of gadodiamide on the signal intensity of unenhanced T1-weighted (T1w) images of the dentate nucleus and globus pallidus in a large population. MATERIALS AND METHODS:A large, single-center retrospective population sur...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000431
更新日期:2018-04-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181e943d2
更新日期:2010-12-01 00:00:00
abstract::High-resolution real-time ultrasonography (5, 7.5, and 10 MHz) was used to examine the menisci of the knee in ten normal volunteers and in ten patients with knee injuries. The posterior horns of the medial and lateral menisci were easily demonstrated. Normal anatomy and pathologic changes could be imaged in the menisc...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198604000-00008
更新日期:1986-04-01 00:00:00
abstract::Gadolinium was attached to antibodies and tested in vitro and in vivo for its effect on proton relaxation enhancement. Using the cyclic anhydride method, diethylenetriaminepentaacetic acid (DTPA) was attached to albumin, IgG and anti-CEA monoclonal antibody. Gadolinium (Gd) was then chelated to the protein complexes f...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198510000-00008
更新日期:1985-10-01 00:00:00