Abstract:
RATIONALE AND OBJECTIVES:Ultrasound can cause destruction of microbubble contrast agents used to enhance medical ultrasound imaging. This study sought to characterize the dynamics of this interaction by direct visual observation of microbubbles during insonification in vitro by a medical ultrasound imaging system. METHODS:Video microscopy was used to observe air-filled sonicated albumin microspheres adsorbed to a solid support during insonation. RESULTS:Deflation was not observed at lowest transmit power settings. At higher intensities, gas left the microparticle gradually, apparently dissolving into the surrounding medium. Deflation was slower for higher microsphere surface densities. Intermittent ultrasound imaging (0.5 Hz refresh rate) caused slower deflation than continuous imaging (33 Hz). CONCLUSIONS:Higher concentrations of microbubbles, lower ultrasound transmit power settings, and intermittent imaging each can reduce the rate of destruction of microspheres resulting from medical ultrasound insonation.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Klibanov AL,Ferrara KW,Hughes MS,Wible JH Jr,Wojdyla JK,Dayton PA,Morgan KE,Brandenburger GHdoi
10.1097/00004424-199812000-00004subject
Has Abstractpub_date
1998-12-01 00:00:00pages
863-70issue
12eissn
0020-9996issn
1536-0210journal_volume
33pub_type
杂志文章abstract::The study aim was to define potential differences and advantages in magnetic resonance (MR) patterns of tumoral contrast enhancement using either a small molecular, extracellular fluid contrast enhancer [Gd-DTPA] or a macromolecular agent [albumin-(Gd-DTPA)20], designed for primary intravascular biodistribution. MR im...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198908000-00007
更新日期:1989-08-01 00:00:00
abstract::Arterial occlusion by direct-current transcatheter electrocoagulation (TCEC) has been developed experimentally and used successfully in clinical situations. The major shortcoming of the technique has been the lengthy time necessary for occlusion of larger arteries. In the present study we attempted to decrease the tim...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198203000-00011
更新日期:1982-03-01 00:00:00
abstract::Using real-time ultrasound, the motions of the tongue, hyoid bone, and larynx were monitored and timed during swallowing in ten normal subjects. A well-defined propulsive wave of the tongue was observed during swallowing a 5-cc water bolus. The body of the hyoid bone was identified on the ultrasound scan as a high ech...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198403000-00003
更新日期:1984-03-01 00:00:00
abstract:OBJECTIVES:This clinical study investigated the pharmacokinetics and safety of gadobutrol, a magnetic resonance (MR) imaging extracellular contrast agent, in pediatric patients aged 2 to 17 years. MATERIALS AND METHODS:In this open-label, multicenter study, patients scheduled for routine contrast-enhanced MR imaging o...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181bfe2d2
更新日期:2009-12-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182a56678
更新日期:2014-01-01 00:00:00
abstract::The design and implementation of a digital radiology image management system requires the definition, evaluation, and comparison of appropriate measures of system performance. The mean throughput rate is an important measure of the actual performance of a finished system. The mean throughput rate identifies the transm...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198602000-00014
更新日期:1986-02-01 00:00:00
abstract:PURPOSE:The aim of this study was to identify the signal intensity (SI) changes in the dentate nucleus (DN) and the globus pallidus (GP) on unenhanced T1-weighted magnetic resonance (MR) images after multiple administration of gadolinium-based contrast agents (GBCAs) in children and compare those changes between linear...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000436
更新日期:2018-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To evaluate the use of a new thrombus-specific ultrasound contrast agent, MRX-408, in the ultrasonic detection of thrombus in arteriovenous (AV) fistulae. METHODS:Six purpose-bred mongrels with two AV fistulae each were imaged with gray-scale ultrasound 7 weeks after graft implantation before ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200001000-00010
更新日期:2000-01-01 00:00:00
abstract::The morphologic changes in healthy rat kidneys (n = 102) were studied 2 or 48 hours after intravenous injection of 1 or 3 g iodine (I)/kg of high-osmolality diatrizoate, low-osmolality iopromide and iohexol, or iso-osmolality iotrolan, as well as after 0.2 or 0.6 g/kg of the high-osmolality magnetic resonance contrast...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199110000-00009
更新日期:1991-10-01 00:00:00
abstract::"Satisfaction of search" (SOS) refers to the effect in which a second lesion remains undetected after detection of another lesion on the same radiograph. The objective of this study was to clarify our understanding of SOS by relating it to total time of inspection and time intervals before, between, and after discover...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199107000-00003
更新日期:1991-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Ureteric jet index (UJI), a newly developed technique derived from color Doppler ultrasonography, may hold promise in evaluating renal function because of its ability to evaluate individual renal function and the use of nonionizing radiation. To assess the usefulness of UJI, the authors in this...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199908000-00001
更新日期:1999-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors report on the development and preliminary validation of a technique for measuring contrast-to-noise ratio (CNR) at all points along selected vessel segments in the original three-dimensional magnetic resonance angiography (MRA) dataset. METHODS:Contrast-to-noise ratio dependencies ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199311000-00005
更新日期:1993-11-01 00:00:00
abstract::Compounds containing mobile protons can act as contrast agents by increasing the value of the term (1/12 - 1/11). The efficiency of this method is markedly pH- and field-dependent. There are many such compounds allowing a choice to be made based on the characteristics of the tissue or organ, magnetic field strength, a...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198809001-00058
更新日期:1988-09-01 00:00:00
abstract:OBJECTIVE:To investigate the effect of saline chase injected at 2 different rates on computed tomography (CT) angiography. MATERIALS AND METHODS:This study was approved by our institutional animal study committee. Three injection protocols were used; contrast injection (24 mL, 0.8 mL/s) without saline chase (protocol ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318032a9fe
更新日期:2007-07-01 00:00:00
abstract::Low-dose transaxial tomography is a technique that can produce cross-sectional images of the hips and femurs in children to permit calculation of the angle of femoral anteversion. Transaxial tomography was compared with computed tomography in terms of measured radiation dose and image quality. Transaxial tomography wa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1985-12-01 00:00:00
abstract:OBJECTIVE:To investigate the correlation between intravoxel incoherent motion (IVIM) model-derived parameters and histologically determined microvascularity in pancreatic ductal adenocarcinomas (PDACs) and pancreatic neuroendocrine tumors (PNETs). MATERIALS AND METHODS:From April 2013 to May 2014, 42 patients with mal...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000187
更新日期:2015-11-01 00:00:00
abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197603000-00009
更新日期:1976-03-01 00:00:00
abstract:OBJECTIVE:Commercially available iodinated contrast media (CM) show significantly different physico-chemical properties. The relevance of the viscosity of CM may be underestimated as a contributing factor for clinically relevant renal failure as suggested by a large registry data analysis (Swedish registry study). The ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318190fbd2
更新日期:2009-02-01 00:00:00
abstract:OBJECTIVE:The aims of this study were to compare 3 contrast agents and to define feasible doses for quantitative lung perfusion imaging using the dual-bolus approach in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). MATERIALS AND METHODS:Ten healthy volunteers (6 males, 4 females; mean age, 23.5 yea...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000224
更新日期:2016-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors conduct technical feasibility and performance studies on a new 0.009-inch nitinol microguidewire for potential neuroendovascular applications. METHODS:In vivo microcatheterizations of brachiocephalic arteries were performed in four pigs using the 0.009-inch nitinol microguidewire w...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199704000-00008
更新日期:1997-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The vasoconstriction of the renal arteries is frequently considered as a crucial factor for radiocontrast-induced nephropathy. A direct effect of iodinated radiographic contrast medium (RCM) on vascular smooth muscle is supposed to be one component of the vascular response. We studied the effec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200208000-00005
更新日期:2002-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Optimal dose schedules and total dose of ionizing radiation for human central nervous system malignancy are not known. An animal model has been developed for the investigation of rat central nervous system response to proton irradiation using magnetic resonance imaging (MRI). A clinical MRI dev...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199504000-00003
更新日期:1995-04-01 00:00:00
abstract:OBJECTIVES:X-ray computed tomography (CT) using phase contrast can provide images with greatly enhanced soft-tissue contrast in comparison to conventional attenuation-based CT. We report on the first scan of a human specimen recorded with a phase-contrast CT system based on an x-ray grating interferometer and a convent...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181e21866
更新日期:2010-07-01 00:00:00
abstract::The authors evaluated double-blind comparative and open-label clinical trials in 1,186 patients who received ioversol to evaluate the safety and efficacy of ioversol, a new nonionic low-osmolality contrast medium, at iodine concentrations of 32%, 24%, and 16%. The results indicate that ioversol was well tolerated in a...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/00004424-198906001-00020
更新日期:1989-06-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to develop a method to determine hepatic and renal clearance of the 2 diastereoisomers (Gd-A, Gd-B) of Gd-EOB-DTPA separately. MATERIALS AND METHODS:Between July 2017 and February 2018, 41 patients with hepatic disease were prospectively included. For each patient, 1 mL of iopromid...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000622
更新日期:2020-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The suitability of paramagnetic complexes as magnetic resonance contrast agents depends on various factors such as their relaxivity, stability, selectivity, and the inertness toward transmetallation by endogenous ions. The transmetallation of a series of 18 gadolinium complexes by the Zn2+ ion ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200102000-00008
更新日期:2001-02-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to compare changes in the signal intensity (SI) ratio of the dentate nucleus (DN) to the pons, DN to cerebrospinal fluid (CSF), and globus pallidus (GP) to thalamus on unenhanced T1-weighted magnetic resonance imaging (MRI) scans after serial injections of the macrocyclic gadolinium-...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000227
更新日期:2015-12-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare a compressed-sensing free-breathing VIBE (fbVIBE) with a conventional breath-hold VIBE (bhVIBE) for dynamic contrast-enhanced imaging of the upper abdomen. MATERIALS AND METHODS:In total, 70 datasets (bhVIBE, n = 30; fbVIBE n = 40; hard-gated [hg] reconstruction, n = 30;...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000607
更新日期:2019-11-01 00:00:00
abstract::Gastrografin and Amipaque with identical iodine content and flavoring were orally administered in 100 ml doses to 10 healthy volunteers in a double-blind crossover study. The nonionic Amipaque has only about one third of the osmolality of Gastrografin, and draws less fluid into the bowel lumen. Consequently there is l...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章
doi:10.1097/00004424-197811000-00008
更新日期:1978-11-01 00:00:00
abstract:OBJECTIVE:The purpose of this study was to assess the effects of gadolinium (Gd3+), provided as gadolinium chloride, on fibroblast function. MATERIALS AND METHODS:Human dermal fibroblasts in monolayer culture and intact skin in organ culture were exposed to the lanthanide metal (1-20 μM). RESULTS:Increased proliferat...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181e943d2
更新日期:2010-12-01 00:00:00