Abstract:
OBJECTIVE:The aims of this study were to compare 3 contrast agents and to define feasible doses for quantitative lung perfusion imaging using the dual-bolus approach in dynamic contrast-enhanced (DCE) magnetic resonance imaging (MRI). MATERIALS AND METHODS:Ten healthy volunteers (6 males, 4 females; mean age, 23.5 years) underwent DCE-MRI at 1.5 T using a 3D FLASH sequence. After a prebolus, 3 doses of gadopentetate dimeglumine (Gd-DTPA), gadofosveset, and gadobenate dimeglumine (Gd-BOPTA) were evaluated. Dose regimes were as follows: Gd-DTPA: 3.0 mL, 6.0 mL, and 12.0 mL with 1.5 mL prebolus; gadofosveset: 1.5 mL, 3.0 mL, and 6.0 mL with 0.8 mL prebolus; and Gd-BOPTA: 1.5 mL, 3.0 mL, and 6.0 mL with 0.8 mL prebolus. Pulmonary blood flow (PBF), pulmonary distribution volume, and mean transit time were assessed for each bolus. Region of interest measurements were used to determine the arterial input function (AIF) in the pulmonary trunk and signal intensities in lung parenchyma. Two radiologists independently rated the subjective image quality of the quantitative perfusion maps based on a 4-point Likert scale. RESULTS:Dose-dependent signal saturation effects were observed for all 3 contrast agents concerning AIF and parenchyma measurements. Signal yields were comparable using Gd-BOPTA (AIF, 214.49 arbitrary units [AU]; parenchyma, 41.7 AU) and Gd-DTPA (207.43 AU; 36.3 AU). Gadofosveset showed significantly lower signal yield (165.74 AU; 25.2 AU; p < 0.008). Highest signal increase was observed for Gd-DTPA. Using Gd-DTPA, mean PBF values for the 3 doses (3 mL, 6 mL, 12 mL) in mL/min per milliliter lung volume were 2.9 ± 1.5, 2.4 ± 1.1, and 1.6 ± 1.0. For the 3 doses of gadofosveset (1.5 mL, 3 mL, 6 mL) mean PBF results were 3.1 ± 1.1, 1.9 ± 0.7, and 1.2 ± 0.6. Last, mean PBF values for Gd-BOPTA (1.5 mL, 3 mL, 6 mL) were 3.4 ± 1.7, 2.8 ± 1.3, and 2.0 ± 0.8. Measurements provided consistent values for all perfusion parameters (PBF, pulmonary distribution volume, mean transit time) when compared with reference literature. Contrast dose volume and the applied contrast agent had no relevant effects on the image quality scores. CONCLUSIONS:The dual-bolus approach using a 3D FLASH sequence is a feasible tool for quantitative lung perfusion imaging. Small boluses of 3 mL for Gd-DTPA, 1.5 mL for Gd-BOPTA, and 1.5 mL for gadofosveset provide sufficient signal yield for quantitative parenchyma measurements. Using higher boluses falsely lower perfusion values have to be considered due to signal saturation effects. Although gadofosveset yielded the lowest signal, the generated quantitative perfusion maps were of diagnostic quality.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Veldhoen S,Oechsner M,Fischer A,Weng AM,Kunz AS,Bley TA,Köstler H,Ritter COdoi
10.1097/RLI.0000000000000224subject
Has Abstractpub_date
2016-03-01 00:00:00pages
186-93issue
3eissn
0020-9996issn
1536-0210journal_volume
51pub_type
杂志文章abstract::Magnetic resonance (MR) methods have been used to study the metabolic and vascular response of model tumors to tumor necrosis factor (TNF). Magnetic resonance measurements demonstrated acute reductions in tumor blood flow, measured from tumor uptake of D2O, and in tumor adenosine triphosphate (ATP), measured by 31P ma...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198912000-00022
更新日期:1989-12-01 00:00:00
abstract::The contrast sensitivity of the retina is greatest in the center and decreases rapidly toward the periphery. Therefore, the detection of low-contrast lung nodules depends upon the manner in which the image is sampled by retinal receptors as eye fixations jump across the image during scanning. The scanning performance ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198705000-00010
更新日期:1987-05-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors analyze the origins of the "clotting issue," the controversy that began in the 1980s when contrast media, once perceived as good flushing agents for catheters because of their assumed anticoagulant properties, came under attack for allegedly causing thromboembolism. Laboratory studi...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:
更新日期:1993-11-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate if pancreatic steatosis measured by proton density fat fraction (PDFF) is associated with exocrine pancreatic function defined by fecal elastase concentrations. MATERIALS AND METHODS:A total of 1458 volunteers (777 women; age range, 21-88 years) underwent magnetic re...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000554
更新日期:2019-07-01 00:00:00
abstract:UNLABELLED:Szapiro D, Ghaye B, Willems V, et al. Evaluation of CT time-density curves of lower-limb veins. Invest Radiol 2001;36:164-169. RATIONALE AND OBJECTIVES:To evaluate time-density curves of the lower-limb veins for optimization of CT venography. METHODS:Fifty patients referred for chest CT were randomized int...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00004424-200103000-00005
更新日期:2001-03-01 00:00:00
abstract::Over the past 120 years, continuous developments in medical imaging has improved diagnosis and treatment for many diseases and has thereby improved treatment outcome and quality of life of many patients. The number of computed tomography (CT) examinations is today increasing by 4% per year worldwide, for a total of ap...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000696
更新日期:2020-09-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:This study evaluated the value of dynamically enhanced fast low-angle shot (FLASH) magnetic resonance (MR) imaging in measuring cardiac output with and without dipyridamole pharmacological stress. METHODS:Ten subjects underwent rest and stress MR imaging. Rest images were acquired using electr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199611000-00003
更新日期:1996-11-01 00:00:00
abstract::An agent has been identified in lymph from rat kidneys rendered ischemic by partial renal artery occlusion that induces a striking neovascular response in a hamster cheek-pouch assay system. The factor has a high molecular weight, cannot be identified in lymph from normal kidneys, and is associated with a marked incre...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198501000-00015
更新日期:1985-01-01 00:00:00
abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199009000-00010
更新日期:1990-09-01 00:00:00
abstract:PURPOSE:To evaluate the feasibility of ex vivo ablation implementing a cryo-based internally cooled bipolar radiofrequency (RF) applicator and to determine the influence of power and gas pressure on the size and shape of the resulting ablation zones. MATERIALS AND METHODS:Two hundred twenty-five ablations were perform...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181b66d11
更新日期:2009-12-01 00:00:00
abstract:OBJECTIVE:With the introduction of ultrashort echo time (UTE) sequences solid polymeric materials might become visible on clinical whole-body magnetic resonance (MR) scanners. The aim of this study was to characterize solid polymeric materials typically used for instruments in magnetic resonance guided interventions an...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318188601f
更新日期:2008-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The reflux of ethanol into the peritoneal cavity during percutaneous ethanol injection therapy (PEIT) of liver neoplasms may cause pain and other side effects. This article studies the optimal injection technique to minimize the reflux of ethanol. METHODS:A technique using normal postmortem pi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199211000-00008
更新日期:1992-11-01 00:00:00
abstract:OBJECTIVES:To evaluate the potential of quantitative assays of vascular characteristics based on dynamic contrast-enhanced magnetic resonance imaging (MRI) using a macromolecular contrast medium (MMCM) to search for and measure effects of dimethyl sulfoxide (DMSO) on cancer vasculature with microscopic correlations. M...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318164b71d
更新日期:2008-05-01 00:00:00
abstract:OBJECTIVES:The objectives of this study were to test the feasibility of an investigational dual-channel next-generation endorectal coil (NG-ERC) in vivo, to quantitatively assess signal-to-noise ratio (SNR), and to get an impression of image quality compared with the current clinically available single-loop endorectal ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3182a56678
更新日期:2014-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:At many institutions, three-dimensional magnetic resonance imaging (MRI) is routinely used for examination of the knee. Multiplanar reconstruction (MPR) is a method of displaying three-dimensional datasets. The authors assessed the usefulness of MPR for evaluating knee MRI datasets by comparing...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199302000-00011
更新日期:1993-02-01 00:00:00
abstract:PURPOSE:To determine whether liver metastases conspicuity is improved at 80 kVp when compared with weighted average (WA) simulated 120 kVp data using dual source dual energy CT. METHODS:A total of 11 patients with 44 hypo-vascular liver metastases underwent contrast enhanced Dual Energy CT (DECT). In all cases the sub...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e3181dfda78
更新日期:2010-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Very small dextran-coated magnetite particles were developed. These particles can be used either as immunospecific contrast agents for MRI by coupling to antibodies or as an interstitial contrast agent. METHODS:The particles were synthesized from iron chloride/dextran solutions. Size was evalu...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200009000-00006
更新日期:2000-09-01 00:00:00
abstract::A patient, suffering a severe anaphylactoid reaction to contrast material injected for an intravenous pyelogram, developed a consumption coagulopathy and evidence of complement activation. Precontrast complement values suggested that the patient had been processing complement via the classical pathway, perhaps as a co...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198011001-00004
更新日期:1980-11-01 00:00:00
abstract:OBJECTIVE:The aim of this study was to compare quantitative and semiquantitative parameters (signal-to-noise ratio [SNR], contrast-to-noise ratio [CNR], image quality, diagnostic confidence) from a standard brain magnetic resonance imaging examination encompassing common neurological disorders such as demyelinating dis...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000256
更新日期:2016-08-01 00:00:00
abstract::Electromagnetic flow measurement study was performed in 20 anesthetized dogs to evaluate the effect of selective celiac infusion of vasopressin on the hepatic arterial vasculature. Teh hepatic arterial flow showed a biphasic response with an initial decrease followed by a substantial increase in spite of a continued ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1975-05-01 00:00:00
abstract::The authors compared the renal toxicity of the low osmolality radiocontrast agents, iohexol and ioxaglate, and the ionic agent, iothalamate, at equivalent iodine dose, using experimental models in vitro and in vivo. In isolated perfused rat kidneys, all agents induced comparable biphasic hemodynamic changes, associate...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199104000-00008
更新日期:1991-04-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to compare F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/magnetic resonance (MR) (with and without diffusion-weighted imaging [DWI]) to F-FDG PET/computed tomography (CT), with regard to the assessment of nodal and extranodal involvement, in patients with Hodgkin lym...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000218
更新日期:2016-03-01 00:00:00
abstract::Twenty-six patients who had received 43 grafts were studied before and after coronary artery vein bypass surgery. Cine ventriculograms taken in the right anterior oblique projection were analyzed and regional ejection fractions calculated. Single and multiple grafts were considered separately as were thrombosed and pa...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197705000-00001
更新日期:1977-05-01 00:00:00
abstract:OBJECTIVES:The authors assessed the relative efficacy of conventional and digital storage-phosphor radiographs for the detection of skull fractures. METHODS:Fifty conventional film-screen radiographs (FSR) and 50 digital storage-phosphor radiographs (DR) with 66 fractures were compared. Five radiologists evaluated ima...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199308000-00005
更新日期:1993-08-01 00:00:00
abstract:OBJECTIVES:The objective of this study was to evaluate the use of dielectric pads for improving high spatial resolution imaging of the inner ear at 7 T. MATERIALS AND METHODS:Two sets of dielectric pads were designed using electromagnetic simulations and implemented using a deuterated suspension of barium titanate. Th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000026
更新日期:2014-05-01 00:00:00
abstract:OBJECTIVES:The aims of this study were to implement and systematically evaluate the performance of a new parameter-free segmented algorithm for analysis of diffusion imaging data using a combined intravoxel incoherent motion and diffusion kurtosis imaging (IVIM-DKI) model of spin diffusion in comparison with the simple...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000223
更新日期:2016-03-01 00:00:00
abstract::Gadolinium was attached to antibodies and tested in vitro and in vivo for its effect on proton relaxation enhancement. Using the cyclic anhydride method, diethylenetriaminepentaacetic acid (DTPA) was attached to albumin, IgG and anti-CEA monoclonal antibody. Gadolinium (Gd) was then chelated to the protein complexes f...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198510000-00008
更新日期:1985-10-01 00:00:00
abstract:OBJECTIVES:The safety of nonionic contrast agents with that of ionic iodinated contrast agents in children is compared. METHODS:A comprehensive literature search was conducted to identify all publications on the safety profile of nonionic contrast agents administered intravenously to children. This information was com...
journal_title:Investigative radiology
pub_type: 杂志文章,评审
doi:10.1097/00004424-199311001-00027
更新日期:1993-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Dynamic contrast enhanced (DCE) MR mammography (MRM) uses tumor capillary density differences for prognosis. The heterogeneous response of permeability-surface area products (PS = Kp<-->t) was examined in mammary tumors, as a function of contrast agent size, to determine what effect ROI size mi...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200204000-00003
更新日期:2002-04-01 00:00:00
abstract:PURPOSE:To evaluate the dependency of tumor contrast enhancement (CE) in regard to protein-binding properties of contrast agents, using 4 different agents with a wide range of protein-binding capacities in a standardized rat brain glioma model. MATERIAL AND METHODS:Sixteen rats with implanted brain gliomas were evalua...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0b013e318191a334
更新日期:2009-02-01 00:00:00