Abstract:
:Diagnostic radiology is expanding, playing an increasingly central role in patient care, which heightens the importance of radiology teaching in undergraduate medical education. This study examined the impact of increased structure and systematic evaluation on student performance in a radiology elective. The evaluation protocol included premultiple and postmultiple choice examinations (70 questions each), a film interpretation quiz (ten films, 20 questions), faculty assessment of a student oral case presentation, and student evaluations of the elective experience. The relationships among the evaluation techniques, as well as differences in class level and course ratings were also examined. Two different treatment groups were studied. Group 1 was given general objectives and information regarding availability of recommended resources, including self-learning materials for the elective, didactic seminars, and viewbox exposure. Group 2 was given specific written instructional objectives, a structured schedule for viewing the self-learning materials, and the same seminars and viewbox exposure. The statistically significant higher performance of the structured group suggests that medical students achieve the objectives of an elective better when learning activities are well defined, structured, and systematically evaluated. In addition, those students receiving the structured experience rated the radiology elective more favorably.
journal_name
Invest Radioljournal_title
Investigative radiologyauthors
Blane CE,Calhoun JG,Maxim BR,Martel W,Davis WKdoi
10.1097/00004424-198505000-00003subject
Has Abstractpub_date
1985-05-01 00:00:00pages
242-5issue
3eissn
0020-9996issn
1536-0210journal_volume
20pub_type
杂志文章abstract::Electromagnetic flow measurement study was performed in 20 anesthetized dogs to evaluate the effect of selective celiac infusion of vasopressin on the hepatic arterial vasculature. Teh hepatic arterial flow showed a biphasic response with an initial decrease followed by a substantial increase in spite of a continued ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1975-05-01 00:00:00
abstract:PURPOSE:The aim of this study was to develop a method to delineate the lethally frozen-tissue region (temperature less than -40°C) arising from interventional cryoablation procedures using a short tau inversion-recovery ultrashort echo-time (STIR-UTE) magnetic resonance (MR) imaging sequence. This method could serve as...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000642
更新日期:2020-05-01 00:00:00
abstract:OBJECTIVES:Ferumoxytol, an intravenous iron supplement, can be used in off-label mode as a contrast agent in magnetic resonance imaging. The aim of this study was to assess whether ferumoxytol can be used as a marker of inflammation in animal models of acute and chronic inflammatory kidney diseases. MATERIAL AND METHO...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000209
更新日期:2016-02-01 00:00:00
abstract:OBJECTIVES:Over the recent years, there have been increasing concerns that exposure to gadolinium-based contrast agents (GBCAs) may be associated with retention of Gd within the skin, bones, and solid organs in patients with normal renal function, although the clinical implications of this deposition remain to be estab...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000657
更新日期:2020-07-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Iopromide is a new monomeric, nonionic contrast agent that exhibits low osmolality and low viscosity in high concentration in aqueous solutions. Double-blind, randomized clinical trials have established the efficacy, safety, and tolerance of iopromide for excretory urography, coronary angiograp...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00004424-199405001-00015
更新日期:1994-05-01 00:00:00
abstract::Thirty patients [four normals, eight with mild and 18 with severe coronary artery disease (CAD)] were studied to evaluate left ventricular function type and post coronary angiography. The end diastolic volume (EDV), end systolic volume (ESV), ejection fraction (EF) and the regional contractility fractions (RCF) of eig...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197603000-00009
更新日期:1976-03-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to achieve initial experience with non-contrast-enhanced (ne) magnetic resonance angiography (MRA) of the lower leg arteries in patients with peripheral arterial occlusive disease (PAOD) at 7 T. MATERIALS AND METHODS:Seven patients with PAOD were examined on a 7-T whole-body magnet...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000044
更新日期:2014-05-01 00:00:00
abstract::The potential of magnetic resonance imaging (MRI) quantification of calcium for the evaluation of pulmonary nodules was investigated in simulated nodules. Calcium salts do not contain mobile protons and thus have no signal on MR proton images. To determine whether the absence of signal from partially calcified nodules...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198711000-00001
更新日期:1987-11-01 00:00:00
abstract::Frequency spectral analysis of cardiac wall motion as calculated from the recorded video kymogram are demonstrated. Characteristic harmonics following the fundamental frequency of the cardiac rate have been demonstrated to have an alternating sequential energy distribution as measured from the free margin of the left ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197503000-00005
更新日期:1975-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To compare gadobenate dimeglumine (Gd-BOPTA) with gadopentetate dimeglumine (Gd-DTPA) for magnetic resonance imaging of the liver. METHODS:The contrast agent Gd-BOPTA or Gd-DTPA was administered at a dose of 0.1 mmol/kg to 257 patients suspected of having malignant liver tumors. Dynamic phase ...
journal_title:Investigative radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1097/00004424-200111000-00002
更新日期:2001-11-01 00:00:00
abstract::Because of a need to correlate pulmonary microvascular changes with physiologic data during lung injury, in vitro and in vivo pulmonary capillary microangiography was performed on normal dogs and those subjected to oleic acid injury and glass bead microembolization. During these studies, no significant differences wer...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:
更新日期:1983-01-01 00:00:00
abstract:PURPOSE:The aim was to investigate the feasibility and image quality of prospective respiratory gating for 3-D computed tomography (CT) of the lung. MATERIAL AND METHODS:Eight anesthetized pigs underwent prospectively gated multidetector computed tomography using 2 devices: a charge-coupled device (CCD) camera and a l...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/01.rli.0000208926.98693.b6
更新日期:2006-05-01 00:00:00
abstract::Gelatin encapsulated nitrogen microbubbles were effective ultrasonic contrast agents in in vitro phantom and in vivo rabbit V2 carcinoma studies. Intra-arterial injection of 80-micrometer gelatin encapsulated nitrogen microbubbles appeared to improve tumor visualization by rim enhancement, which persisted for several ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198005000-00013
更新日期:1980-05-01 00:00:00
abstract::Perfluoroctylbromide (PFOB), a radiopaque reticuloendothelial system contrast media for computed tomography, has been shown to accumulate in macrophages. In the current study PFOB was tested in rabbits as an abscess imaging agent. Two abscesses were induced in each of 24 rabbits, one in the liver and the other in the ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198409000-00017
更新日期:1984-09-01 00:00:00
abstract:PURPOSE:The purpose of this study was to evaluate image quality of a spectral photon-counting detector (PCD) computed tomography (CT) system for evaluation of major arteries of the head and neck compared with conventional single-energy CT scans using energy-integrating detectors (EIDs). METHODS:In this institutional r...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000418
更新日期:2018-03-01 00:00:00
abstract::Simultaneous inflation of two balloons may be necessary for balloon dilation valvuloplasty in patients with a large annulus. We examined the cardiovascular effects of dilating the pulmonary annulus with two balloons in 18 normal dogs using pulsed Doppler ultrasound and gross and microscopic examination. When the ratio...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198808000-00005
更新日期:1988-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:Magnetic resonance imaging (MRI) techniques seem to be very promising for 3D dosimetry studies, but long imaging acquisition time limits their use. A new fast T1 mapping protocol, easy to implement on a conventional MR imager, has been used to determine dose distributions on Fricke gels. METHO...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199903000-00014
更新日期:1999-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To demonstrate the usefulness of a model of the parenchymous vascularization to evaluate texture analysis methods. METHODS:Slices with thickness varying from 1 to 4 mm were reformatted from a 3D vascular model corresponding to either normal tissue perfusion or local hypervascularization. Param...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199903000-00004
更新日期:1999-03-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors investigated whether gadolinium-ethoxybenzyl-DTPA (Gd-EOB-DTPA) can be eliminated in the absence of the two usual excretory pathways (urinary or biliary) and whether a remaining excretory pathway is able to compensate for impaired liver or kidney function. METHODS:The study was per...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199402000-00017
更新日期:1994-02-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors compare the magnetic resonance (MR) phase contrast flow velocity measurements in varying concentric stenoses with invasive measurements obtained with a Doppler guidewire. METHODS:Flow velocity measurements were obtained using a calibrated 0.018 inch 12 MHz Doppler guidewire and a 1...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199808000-00001
更新日期:1998-08-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The purpose of the study was to evaluate the effect of articular fluid distention on patellar position at different degrees of knee angulation. METHODS:Patellar position in 10 cadaveric knee specimens was determined with 30, 100, and 200 mm Hg joint distention at 45, 20, and 5 degrees of knee ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199602000-00001
更新日期:1996-02-01 00:00:00
abstract::The cytogenetic interactions of ionic (diatrizoate, ioxaglate) and nonionic (iohexol) contrast media (CM) with antineoplastic drugs cyclophosphamide (CPA) and carmustine (CARM) were evaluated in a rat bone marrow cell model. Male Wistar rats were anesthetized with a 6% chloral hydrate solution and divided into five gr...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-198805000-00011
更新日期:1988-05-01 00:00:00
abstract::Fractures modeled in the dried skull indicate that the initial plane of computed tomography (CT) section contributes to the accuracy of three-dimensional (3D) images generated from two-dimensional (2D) CT data. The authors retrospectively analyzed seven clinical cases of tripod zygomatic fractures that were imaged wit...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199105000-00009
更新日期:1991-05-01 00:00:00
abstract:OBJECTIVES:The aim of this study was to investigate the impact of a novel iterative denoising and image enhancement technique in T1-weighted precontrast and postcontrast volume-interpolated breath-hold examination (VIBE) of the abdomen on image quality, noise levels, and diagnostic confidence without change of acquisit...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/RLI.0000000000000746
更新日期:2020-11-18 00:00:00
abstract::A radiographic method for use in the closed-chest dog is described which allows the quantitation of segmental mechanical performance. Previous work has shown that the area of the pressure-length loop (an approximation of a stress-strain integral) is a useful measure of the mechanical work performed by a segment of myo...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-197611000-00010
更新日期:1976-11-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To summarize the chemical synthesis, physicochemical characterization, pharmacokinetic behavior, and biological evaluation of P743, a new macromolecular iodinated contrast medium. METHODS:The synthesis and molecular modeling of the iodinated macromolecule P743 are described. The pharmacokineti...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-200101000-00006
更新日期:2001-01-01 00:00:00
abstract::Due to the small size of the bronchial arteries, the bronchial circulation is difficult to study and remains poorly understood. We have utilized single photon emission computed tomography (SPECT) as a noninvasive means of studying the bronchial circulation. Imaging studies were performed in sheep before and after the ...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199001000-00014
更新日期:1990-01-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:To investigate image mottle in conventional CT images of the abdomen as a function of radiographic technique factors and patient size. METHODS:Water-filled phantoms simulating the abdomens of adult (32 cm in diameter) and pediatric (16 cm in diameter) patients were used to investigate image mo...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199904000-00005
更新日期:1999-04-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:The authors synthesized and tested a novel hydrogel system proposed for use in extra- and intravascular radiologic interventions, such as chemoembolizations and embolizations, and as a vehicle for sustained drug release. MATERIALS:The material was specifically designed to meet the prerequisite...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199312000-00001
更新日期:1993-12-01 00:00:00
abstract:RATIONALE AND OBJECTIVES:It is widely believed that down-sizing catheters, and possibly needles, will decrease damage to the entry vessel in the performance of angiography. The purposes of this in vitro experiment are to determine if smaller needles produce less arterial wall damage than larger needles and to assess th...
journal_title:Investigative radiology
pub_type: 杂志文章
doi:10.1097/00004424-199210000-00001
更新日期:1992-10-01 00:00:00