Appearance of breast cysts in planar geometry photoacoustic mammography using 1064-nm excitation.

Abstract:

:In the search for improved imaging modalities for detection and diagnosis of breast cancer, a high negative prediction value is also important. Photoacoustic (optoacoustic) imaging is a relatively new technique that has high potential for visualizing breast malignancies, but little is known about the photoacoustic appearance of benign lesions. In this work, we investigate the visibility of benign breast cysts in forward-mode photoacoustic mammography using 1064-nm light, as currently applied in the Twente photoacoustic mammoscope. Results from (Monte Carlo and k-wave) simulations and phantom measurements were used to interpret results from patient measurements. There was a strong agreement among the results from simulations, phantom, and patient measurements. Depending on the absorption contrast between cyst and breast tissue, cysts were visible as either one or two confined high-contrast areas representing the front and the back of the cyst, respectively. This edge enhancement is most likely the consequence of the local sudden change in the absorbed energy density and Grüneisen coefficients. Although the current forward-mode single-wavelength photoacoustic mammoscope cannot always unambiguously discriminate cysts from malignancies, this study reveals specific features of cysts compared to malignancies, which can be exploited for discrimination of the two abnormalities in future modifications of the imager.

journal_name

J Biomed Opt

authors

Heijblom M,Piras D,Maartens E,Huisman EJ,van den Engh FM,Klaase JM,Steenbergen W,Manohar S

doi

10.1117/1.JBO.18.12.126009

subject

Has Abstract

pub_date

2013-12-01 00:00:00

pages

126009

issue

12

eissn

1083-3668

issn

1560-2281

pii

1790527

journal_volume

18

pub_type

杂志文章
  • Three-dimensional optical method for integrated visualization of mouse islet microstructure and vascular network with subcellular-level resolution.

    abstract::Microscopic visualization of islets of Langerhans under normal and diabetic conditions is essential for understanding the pathophysiology of the disease. The intrinsic opacity of pancreata, however, limits optical accessibility for high-resolution light microscopy of islets in situ. Because the standard microtome-base...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3470241

    authors: Fu YY,Lu CH,Lin CW,Juang JH,Enikolopov G,Sibley E,Chiang AS,Tang SC

    更新日期:2010-07-01 00:00:00

  • Performance of a lookup table-based approach for measuring tissue optical properties with diffuse optical spectroscopy.

    abstract::Diffuse optical spectroscopy (DOS) provides a powerful tool for fast and noninvasive disease diagnosis. The ability to leverage DOS to accurately quantify tissue optical parameters hinges on the model used to estimate light-tissue interaction. We describe the accuracy of a lookup table (LUT)-based inverse model for me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.057001

    authors: Nichols BS,Rajaram N,Tunnell JW

    更新日期:2012-05-01 00:00:00

  • Near-infrared fluorescence goggle system with complementary metal-oxide-semiconductor imaging sensor and see-through display.

    abstract::We have developed a near-infrared (NIR) fluorescence goggle system based on the complementary metal-oxide-semiconductor active pixel sensor imaging and see-through display technologies. The fluorescence goggle system is a compact wearable intraoperative fluorescence imaging and display system that can guide surgery in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.101303

    authors: Liu Y,Njuguna R,Matthews T,Akers WJ,Sudlow GP,Mondal S,Tang R,Gruev V,Achilefu S

    更新日期:2013-10-01 00:00:00

  • Optical detection of intracellular cavitation during selective laser targeting of the retinal pigment epithelium: dependence of cell death mechanism on pulse duration.

    abstract::Selective laser targeting of the retinal pigment epithelium (RPE) is an attractive method for treating RPE-associated disorders. We are developing a method for optically detecting intracellular microcavitation that can potentially serve as an immediate feedback of the treatment outcome. Thermal denaturation or intrace...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2804078

    authors: Lee H,Alt C,Pitsillides CM,Lin CP

    更新日期:2007-11-01 00:00:00

  • Optically sectioned in vivo imaging with speckle illumination HiLo microscopy.

    abstract::We present a simple wide-field imaging technique, called HiLo microscopy, that is capable of producing optically sectioned images in real time, comparable in quality to confocal laser scanning microscopy. The technique is based on the fusion of two raw images, one acquired with speckle illumination and another with st...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3528656

    authors: Lim D,Ford TN,Chu KK,Mertz J

    更新日期:2011-01-01 00:00:00

  • Scattering coefficient determination in turbid media with backscattered polarized light.

    abstract::A simple empirical method is presented to determine the scattering coefficient mu' s from backscattered polarized images of turbid media. It uses the ratio, pixel by pixel, of two images that are the second and the first backscattered Stokes parameter images Q and I, respectively. Taking this image ratio, then integra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1924715

    authors: Jaillon F,Saint-Jalmes H

    更新日期:2005-05-01 00:00:00

  • Variations in the endogenous fluorescence of rabbit corneas after mechanical property alterations.

    abstract::Keratoconus is an eye disease in which the cornea progressively deforms due to loss of cornea mechanical rigidity, and thus causes deterioration of visual acuity. Techniques to characterize the mechanical characteristics of the cornea are important to better monitor changes and response to treatments. To investigate t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.095005

    authors: Ortega-Martinez A,Touchette G,Zhu H,Kochevar IE,Franco W

    更新日期:2017-09-01 00:00:00

  • Potential of optical microangiography to monitor cerebral blood perfusion and vascular plasticity following traumatic brain injury in mice in vivo.

    abstract::Optical microanglography (OMAG) is a recently developed imaging modality capable of volumetric imaging of dynamic blood perfusion, down to capillary level resolution, with an imaging depth up to 2.00 mm beneath the tissue surface. We report the use of OMAG to monitor the cerebral blood flow (CBF) over the cortex of mo...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3207121

    authors: Jia Y,Alkayed N,Wang RK

    更新日期:2009-07-01 00:00:00

  • Comparison of time-resolved and continuous-wave near-infrared techniques for measuring cerebral blood flow in piglets.

    abstract::A primary focus of neurointensive care is monitoring the injured brain to detect harmful events that can impair cerebral blood flow (CBF), resulting in further injury. Since current noninvasive methods used in the clinic can only assess blood flow indirectly, the goal of this research is to develop an optical techniqu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3488626

    authors: Diop M,Tichauer KM,Elliott JT,Migueis M,Lee TY,St Lawrence K

    更新日期:2010-09-01 00:00:00

  • Effect of noise on modulation amplitude and phase in frequency-domain diffusive imaging.

    abstract::We theoretically investigate the effect of noise on frequency-domain heterodyne and/or homodyne measurements of intensity-modulated beams propagating through diffusive media, such as a photon density wave. We assumed that the attenuated amplitude and delayed phase are estimated by taking the Fourier transform of the n...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.016010

    authors: Kang D,Kupinski MA

    更新日期:2012-01-01 00:00:00

  • Dual closed-loop, optoelectronic, auto-oscillatory detection circuit for monitoring fluorescence lifetime-based chemical sensors and biosensors.

    abstract::We present a new detection instrument for sensor measurements based on excited-state fluorescence lifetimes. This system consists of a primary optoelectronic loop containing a resonance-type rf amplifier, a modulatable fluorescence-excitation light source, a fiber optic feedback loop (with a gap for a fluorescent sens...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1688814

    authors: Rabinovich E,Sviminoshvilli T,O'Brien MJ,Brueck SR,Lopez GP

    更新日期:2004-05-01 00:00:00

  • Two-photon microscopy and spectroscopy based on a compact confocal scanning head.

    abstract::We have combined a confocal laser scanning head modified for TPE (two-photon excitation) microscopy with some spectroscopic modules to study single molecules and molecular aggregates. The behavior of the TPE microscope unit has been characterized by means of point spread function measurements and of the demonstration ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.1382809

    authors: Diaspro A,Chirico G,Federici F,Cannone F,Beretta S,Robello M

    更新日期:2001-07-01 00:00:00

  • Visible-wavelength two-photon excitation microscopy with multifocus scanning for volumetric live-cell imaging.

    abstract::Two-photon excitation microscopy is one of the key techniques used to observe three-dimensional (3-D) structures in biological samples. We utilized a visible-wavelength laser beam for two-photon excitation in a multifocus confocal scanning system to improve the spatial resolution and image contrast in 3-D live-cell im...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.1.014502

    authors: Oketani R,Suda H,Uegaki K,Kubo T,Matsuda T,Yamanaka M,Arai Y,Smith N,Nagai T,Fujita K

    更新日期:2019-11-01 00:00:00

  • Analysis of blood coagulation process based on fractality and dynamic characteristic of laser speckle pattern.

    abstract::The reflection and transmission of coherent light from a biological system can yield information about its condition. In the case of blood exposed to the air, there is a change in the properties of the speckle patterns observed in the coagulation process. This can be studied by means of the rate of temporal variation,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.3.031018

    authors: Yokoi N,Aizu Y,Uozumi J

    更新日期:2018-12-01 00:00:00

  • Measurement of the refractive index of whole blood and its components for a continuous spectral region.

    abstract::The refractive index of blood is a key biophysical parameter, which can reflect the physiological state. We measured the refractive index of whole blood and other components, such as serum, plasma, and hemoglobin, based on internal reflection by using a homemade apparatus in the spectral range of 400 to 750 nm. In add...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.3.035003

    authors: Liu S,Deng Z,Li J,Wang J,Huang N,Cui R,Zhang Q,Mei J,Zhou W,Zhang C,Ye Q,Tian J

    更新日期:2019-03-01 00:00:00

  • Detection of enzyme activity in orthotopic murine breast cancer by fluorescence lifetime imaging using a fluorescence resonance energy transfer-based molecular probe.

    abstract::Cancer-related enzyme activity can be detected noninvasively using activatable fluorescent molecular probes. In contrast to "always-on" fluorescent molecular probes, activatable probes are relatively nonfluorescent at the time of administration due to intramolecular fluorescence resonance energy transfer (FRET). Enzym...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3594153

    authors: Solomon M,Guo K,Sudlow GP,Berezin MY,Edwards WB,Achilefu S,Akers WJ

    更新日期:2011-06-01 00:00:00

  • New laryngoscope for quantitative high-speed imaging of human vocal folds vibration in the horizontal and vertical direction.

    abstract::We report the design of a novel laser line-triangulation laryngoscope for the quantitative visualization of the three-dimensional movements of human vocal folds during phonation. This is the first successful in vivo recording of the three-dimensional movements of human vocal folds in absolute values. Triangulation ima...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3041164

    authors: George NA,de Mul FF,Qiu Q,Rakhorst G,Schutte HK

    更新日期:2008-11-01 00:00:00

  • Spectral classifier design with ensemble classifiers and misclassification-rejection: application to elastic-scattering spectroscopy for detection of colonic neoplasia.

    abstract::Optical spectroscopy has shown potential as a real-time, in vivo, diagnostic tool for identifying neoplasia during endoscopy. We present the development of a diagnostic algorithm to classify elastic-scattering spectroscopy (ESS) spectra as either neoplastic or non-neoplastic. The algorithm is based on pattern recognit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3592488

    authors: Rodriguez-Diaz E,Castanon DA,Singh SK,Bigio IJ

    更新日期:2011-06-01 00:00:00

  • Multiwavelength time-resolved detection of fluorescence during the inflow of indocyanine green into the adult's brain.

    abstract::Optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for clinical assessment of brain perfusion in adults at the bedside. Methodology of multiwavelength and time-resolved detection of fluorescence light excited in the ICG is p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.087001

    authors: Gerega A,Milej D,Weigl W,Botwicz M,Zolek N,Kacprzak M,Wierzejski W,Toczylowska B,Mayzner-Zawadzka E,Maniewski R,Liebert A

    更新日期:2012-08-01 00:00:00

  • Imaging tumor hypoxia by near-infrared fluorescence tomography.

    abstract::We have developed a novel nitroimidazole indocyanine dye conjugate for tumor-targeted hypoxia fluorescence tomography. The hypoxia probe has been evaluated in vitro using tumor cell lines and in vivo with tumor targeting in mice. The in vitro cell studies were performed to assess fluorescence labeling differences betw...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3589348

    authors: Biswal NC,Pavlik C,Smith MB,Aguirre A,Xu Y,Zanganeh S,Kuhn LT,Claffey KP,Zhu Q

    更新日期:2011-06-01 00:00:00

  • Spectral imaging technique for retinal perfusion detection using confocal scanning laser ophthalmoscopy.

    abstract::To evaluate retinal perfusion in the human eye, a dual-wavelength confocal scanning laser ophthalmoscope (cSLO) was developed that provides spectral imaging of the fundus using a combination of red (670 nm) and near-infrared (810 nm) wavelengths. The image of the ocular fundus was analyzed to find out if quantitative ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.116005

    authors: Rasta SH,Manivannan A,Sharp PF

    更新日期:2012-11-01 00:00:00

  • Detecting glucose-induced changes in in vitro and in vivo experiments with optical coherence tomography.

    abstract::Optical clearing is a well-known phenomenon. It is based on the matching of refractive indices of a bulk material and scattering particles. The same principle is also used in scattering-based optical measurements of different constituents, such as glucose. By registering changes in scattering, it is possible to evalua...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2904957

    authors: Kinnunen M,Myllylä R,Vainio S

    更新日期:2008-03-01 00:00:00

  • Time-reversed ultrasonically encoded optical focusing using two ultrasonic transducers for improved ultrasonic axial resolution.

    abstract::Focusing light inside highly scattering media is a challenging task in biomedical optical imaging, manipulation, and therapy. A recent invention has overcome this challenge by time reversing ultrasonically encoded diffuse light to an ultrasound-modulated volume inside a turbid medium. In this technique, a photorefract...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.110502

    authors: Yang Q,Xu X,Lai P,Xu D,Wang LV

    更新日期:2013-11-01 00:00:00

  • Photoacoustic tomography of ex vivo mouse hearts with myocardial infarction.

    abstract::In the present study, we evaluated the applicability of ex vivo photoacoustic imaging (PAI) on small animal organs. We used photoacoustic tomography (PAT) to visualize infarcted areas within murine hearts and compared these data to other imaging techniques [magnetic resonance imaging (MRI), micro-computed tomography] ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3556720

    authors: Holotta M,Grossauer H,Kremser C,Torbica P,Völkl J,Degenhart G,Esterhammer R,Nuster R,Paltauf G,Jaschke W

    更新日期:2011-03-01 00:00:00

  • High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second.

    abstract::We propose a useful method to boost the imaging speed for spectral domain optical coherence tomography (SDOCT) by multiplying a number of high-speed spectrometers used in the system with selective precise control of data-recording and data-reading phases for spectral cameras employed in each spectrometer. To demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3592492

    authors: An L,Guan G,Wang RK

    更新日期:2011-06-01 00:00:00

  • Micro-Raman spectroscopy study of cancerous and normal nasopharyngeal tissues.

    abstract::The capabilities of micro-Raman spectroscopy for differentiating normal and malignant nasopharyngeal tissues were evaluated. Raman scattering signals were acquired from 22 normal and 52 malignant nasopharyngeal tissue samples. Distinctive spectral differences in Raman spectra between normal and malignant nasopharyngea...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.2.027003

    authors: Li Y,Pan J,Chen G,Li C,Lin S,Shao Y,Feng S,Huang Z,Xie S,Zeng H,Chen R

    更新日期:2013-02-01 00:00:00

  • Delineation of an oral cancer lesion with swept-source optical coherence tomography.

    abstract::We demonstrate the ex vivo imaging of an oral cancerous sample with a swept-source optical coherence tomography (SS-OCT) system. With the axial resolution of 8 microm in free space and system sensitivity of 108 dB, we can well distinguish the normal and abnormal tissue portions in a sample. In particular, we analyze t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2960632

    authors: Tsai MT,Lee HC,Lu CW,Wang YM,Lee CK,Yang CC,Chiang CP

    更新日期:2008-07-01 00:00:00

  • Band analysis of hydrated human skin stratum corneum attenuated total reflectance fourier transform infrared spectra in vivo.

    abstract::Water content is an important factor for skin condition. The determination of the hydration state of the skin is necessary to obtain basic knowledge about the penetration and loss of water in the skin stratum corneum. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy is used to measure hy...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429890

    authors: Lucassen GW,van Veen GN,Jansen JA

    更新日期:1998-07-01 00:00:00

  • Multimodal optical measurement in vitro of surface deformations and wall thickness of the pressurized aortic arch.

    abstract::Computational modeling of arterial mechanics continues to progress, even to the point of allowing the study of complex regions such as the aortic arch. Nevertheless, most prior studies assign homogeneous and isotropic material properties and constant wall thickness even when implementing patient-specific luminal geome...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.4.046005

    authors: Genovese K,Humphrey JD

    更新日期:2015-04-01 00:00:00

  • Early diagnosis of teeth erosion using polarized laser speckle imaging.

    abstract::Dental erosion starts with a chemical attack on dental tissue causing tooth demineralization, altering the tooth structure and making it more sensitive to mechanical erosion. Medical diagnosis of dental erosion is commonly achieved through a visual inspection by the dentist during dental checkups and is therefore high...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.071103

    authors: Abou Nader C,Pellen F,Loutfi H,Mansour R,Le Jeune B,Le Brun G,Abboud M

    更新日期:2016-07-01 00:00:00