Potential of optical microangiography to monitor cerebral blood perfusion and vascular plasticity following traumatic brain injury in mice in vivo.

Abstract:

:Optical microanglography (OMAG) is a recently developed imaging modality capable of volumetric imaging of dynamic blood perfusion, down to capillary level resolution, with an imaging depth up to 2.00 mm beneath the tissue surface. We report the use of OMAG to monitor the cerebral blood flow (CBF) over the cortex of mouse brain upon traumatic brain injury (TBI), with the cranium left intact, for a period of two weeks on the same animal. We show the ability of OMAG to repeatedly image 3-D cerebral vasculatures during pre- and post-traumatic phases, and to visualize the changes of regulated CBF and the vascular plasticity after TBI. The results indicate the potential of OMAG to explore the mechanism involved in the rehabilitation of TBI.

journal_name

J Biomed Opt

authors

Jia Y,Alkayed N,Wang RK

doi

10.1117/1.3207121

subject

Has Abstract

pub_date

2009-07-01 00:00:00

pages

040505

issue

4

eissn

1083-3668

issn

1560-2281

journal_volume

14

pub_type

信件
  • Correlation of functional and resting state connectivity of cerebral oxy-, deoxy-, and total hemoglobin concentration changes measured by near-infrared spectrophotometry.

    abstract::The aim is to study cerebral vascular functional connectivity during motor tasks and resting state using multichannel frequency-domain near-infrared spectrophotometry. Maps of 5.7 × 10.8 cm size displaying changes in cerebral oxyhemoglobin (O(2)Hb), deoxyhemoglobin (HHb), and total hemoglobin (tHb) concentrations were...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3615249

    authors: Wolf U,Toronov V,Choi JH,Gupta R,Michalos A,Gratton E,Wolf M

    更新日期:2011-08-01 00:00:00

  • Protein conformation and molecular order probed by second-harmonic-generation microscopy.

    abstract::Second-harmonic-generation (SHG) microscopy has emerged as a powerful tool to image unstained living tissues and probe their molecular and supramolecular organization. In this article, we review the physical basis of SHG, highlighting how coherent summation of second-harmonic response leads to the sensitivity of polar...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.17.6.060901

    authors: Vanzi F,Sacconi L,Cicchi R,Pavone FS

    更新日期:2012-06-01 00:00:00

  • Two-photon microscopy on vital carotid arteries: imaging the relationship between collagen and inflammatory cells in atherosclerotic plaques.

    abstract::We used two-photon laser scanning microscopy (TPLSM) to demonstrate for the first time its potential in studying relational details at the cellular level of atherogenesis in intact, viable mouse carotid arteries. Isolated and mounted arteries of ApoE-/-mice, aged 15 or 21 weeks (7 and 13 weeks on western diet), were i...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2965542

    authors: Megens RT,oude Egbrink MG,Merkx M,Slaaf DW,van Zandvoort MA

    更新日期:2008-07-01 00:00:00

  • Super-resolution photoacoustic microscopy using photonic nanojets: a simulation study.

    abstract::Optical resolution photoacoustic microscopy (ORPAM) is important for various biomedical applications, such as the study of cellular structures, microcirculation systems, and tumor angiogenesis. However, the lateral resolution of a conventional ORPAM is limited by optical diffraction. In this work, we report a simulati...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.116003

    authors: Upputuri PK,Wen ZB,Wu Z,Pramanik M

    更新日期:2014-01-01 00:00:00

  • Multiwavelength time-resolved detection of fluorescence during the inflow of indocyanine green into the adult's brain.

    abstract::Optical technique based on diffuse reflectance measurement combined with indocyanine green (ICG) bolus tracking is extensively tested as a method for clinical assessment of brain perfusion in adults at the bedside. Methodology of multiwavelength and time-resolved detection of fluorescence light excited in the ICG is p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.087001

    authors: Gerega A,Milej D,Weigl W,Botwicz M,Zolek N,Kacprzak M,Wierzejski W,Toczylowska B,Mayzner-Zawadzka E,Maniewski R,Liebert A

    更新日期:2012-08-01 00:00:00

  • Monitoring remineralization of enamel subsurface lesions by optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is a potential clinical tool for enamel lesion monitoring. Swept-source OCT findings were compared with cross-sectional nanohardness findings of enamel. Subsurface bovine enamel lesions in three groups were subjected to (1) deionized water (control), (2) phosphoryl oligosaccharide of...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.4.046006

    authors: Mandurah MM,Sadr A,Shimada Y,Kitasako Y,Nakashima S,Bakhsh TA,Tagami J,Sumi Y

    更新日期:2013-04-01 00:00:00

  • Blind deconvolution estimation of fluorescence measurements through quadratic programming.

    abstract::Time-deconvolution of the instrument response from fluorescence lifetime imaging microscopy (FLIM) data is usually necessary for accurate fluorescence lifetime estimation. In many applications, however, the instrument response is not available. In such cases, a blind deconvolution approach is required. An iterative me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075010

    authors: Campos-Delgado DU,Gutierrez-Navarro O,Arce-Santana ER,Skala MC,Walsh AJ,Jo JA

    更新日期:2015-07-01 00:00:00

  • Determination of optical properties of human blood in the spectral range 250 to 1100 nm using Monte Carlo simulations with hematocrit-dependent effective scattering phase functions.

    abstract::The absorption coefficient mu(a), scattering coefficient mu(s), and anisotropy factor g of diluted and undiluted human blood (hematocrit 0.84 and 42.1%) are determined under flow conditions in the wavelength range 250 to 1100 nm, covering the absorption bands of hemoglobin. These values are obtained by high precision ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2203659

    authors: Friebel M,Roggan A,Müller G,Meinke M

    更新日期:2006-05-01 00:00:00

  • Prehistological evaluation of benign and malignant pigmented skin lesions with optical computed tomography.

    abstract::Discrimination of benign and malignant melanocytic lesions is a major issue in clinical dermatology. Assessment of the thickness of melanoma is critical for prognosis and treatment selection. We aimed to evaluate a novel optical computed tomography (optical-CT) system as a tool for three-dimensional (3-D) imaging of m...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.066004

    authors: Kokolakis A,Zacharakis G,Krasagakis K,Lasithiotakis K,Favicchio R,Spiliopoulos G,Giannikaki E,Ripoll J,Tosca A

    更新日期:2012-06-01 00:00:00

  • Multispectral in vivo three-dimensional optical coherence tomography of human skin.

    abstract::The capability of optical coherence tomography (OCT) to perform "optical biopsy" of tissues within a depth range of 1 to 2 mm with micron-scale resolution in real time makes it a promising biomedical imaging modality for dermatologic applications. Three high-speed, spectrometer-based frequency-domain OCT systems opera...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3400665

    authors: Alex A,Povazay B,Hofer B,Popov S,Glittenberg C,Binder S,Drexler W

    更新日期:2010-03-01 00:00:00

  • Raman mapping of oral buccal mucosa: a spectral histopathology approach.

    abstract::Oral cancer is one of the most common cancers worldwide. One-fifth of the world's oral cancer subjects are from India and other South Asian countries. The present Raman mapping study was carried out to understand biochemical variations in normal and malignant oral buccal mucosa. Data were acquired using WITec alpha 30...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.12.126005

    authors: Behl I,Kukreja L,Deshmukh A,Singh SP,Mamgain H,Hole AR,Krishna CM

    更新日期:2014-12-01 00:00:00

  • Theory and practical recommendations for autocorrelation-based image correlation spectroscopy.

    abstract::Image correlation spectroscopy (ICS) is a powerful technique for detecting arrangement of fluorophores in images. This tutorial gives background into the mathematical underpinnings of ICS, specifically image autocorrelation. The effects of various artifacts and image processing steps, including background subtraction,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.080801

    authors: Robertson C,George SC

    更新日期:2012-08-01 00:00:00

  • Novel fluorescent oxygen indicator for intracellular oxygen measurements.

    abstract::Intracellular oxygen concentration is of primary importance in determining numerous physiological and pathological processes in biological systems. In this paper, we describe the application of the oxygen sensing indicator, ruthenium dibipyridine 4-(1"-pyrenyl)-2,2'-bipyridine chloride [Ru(bpy-pyr)(bpy)(2)], for molec...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1483082

    authors: Ji J,Rosenzweig N,Jones I,Rosenzweig Z

    更新日期:2002-07-01 00:00:00

  • Optical delivery of liposome encapsulated chemical stimuli to neuronal cells.

    abstract::Spatially confined and precise time delivery of neuroactive molecules is an important issue in neurophysiology. In this work we developed a technique for delivering chemical stimuli to cultured neurons consisting in encapsulating the molecules of interest in liposomes. These vectors were then loaded in reservoirs cons...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3616133

    authors: Pinato G,Raffaelli T,D'Este E,Tavano F,Cojoc D

    更新日期:2011-09-01 00:00:00

  • Method measuring oxygen tension and transport within subcutaneous devices.

    abstract::Cellular therapies hold promise to replace the implantation of whole organs in the treatment of disease. For most cell types, in vivo viability depends on oxygen delivery to avoid the toxic effects of hypoxia. A promising approach is the in situ vascularization of implantable devices which can mediate hypoxia and impr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.087006

    authors: Weidling J,Sameni S,Lakey JR,Botvinick E

    更新日期:2014-08-01 00:00:00

  • Morphological and chemical changes in dentin after using endodontic agents: fourier transform Raman spectroscopy, energy-dispersive x-ray fluorescence spectrometry, and scanning electron microscopy study.

    abstract::We examine the morphological and chemical changes in the pulp chamber dentin after using endodontic agents by scanning electron microscopy (SEM), Fourier transform Raman spectroscopy (FT-Raman), and micro energy-dispersive x-ray fluorescence spectrometry (μEDXRF). Thirty teeth were sectioned exposing the pulp chamber ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.075008

    authors: Pascon FM,Kantovitz KR,Soares LE,Santo AM,Martin AA,Puppin-Rontani RM

    更新日期:2012-07-01 00:00:00

  • Fluorescence Talbot microscope using incoherent source.

    abstract::Fluorescence Talbot microscope is a scalable field-of-view (FOV) imaging platform, which takes advantage of the phase sensitivity of the self-image of a periodic structure. Such a system can maintain the microscopic resolution and extend the FOV for the whole slide (15  mm×15  mm) scanning. Previously reported Talbot ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.8.086003

    authors: Sun Y,Pang S

    更新日期:2016-08-01 00:00:00

  • Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle.

    abstract::We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coeffici...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.125005

    authors: Li Z,Baker WB,Parthasarathy AB,Ko TS,Wang D,Schenkel S,Durduran T,Li G,Yodh AG

    更新日期:2015-01-01 00:00:00

  • Intracranial glioma xenograft model rapidly reestablishes blood-brain barrier integrity for longitudinal imaging of tumor progression using fluorescence molecular tomography and contrast agents.

    abstract:SIGNIFICANCE:The blood-brain barrier (BBB) is a major obstacle to detecting and treating brain tumors. Overcoming this challenge will facilitate the early and accurate detection of brain lesions and guide surgical resection of tumors. AIM:We generated an orthotopic brain tumor model that simulates the pathophysiology ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.2.026004

    authors: Habimana-Griffin L,Ye D,Carpenter J,Prior J,Sudlow G,Marsala L,Mixdorf M,Rubin J,Chen H,Achilefu S

    更新日期:2020-02-01 00:00:00

  • Accurate single-shot quantitative phase imaging of biological specimens with telecentric digital holographic microscopy.

    abstract::The advantages of using a telecentric imaging system in digital holographic microscopy (DHM) to study biological specimens are highlighted. To this end, the performances of nontelecentric DHM and telecentric DHM are evaluated from the quantitative phase imaging (QPI) point of view. The evaluated stability of the micro...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046022

    authors: Doblas A,Sánchez-Ortiga E,Martínez-Corral M,Saavedra G,Garcia-Sucerquia J

    更新日期:2014-04-01 00:00:00

  • No-core fiber-based highly sensitive optical fiber pH sensor.

    abstract::The present work describes the fabrication and characterization of an optical fiber pH sensor using a sol–gel technique. The sensing head configuration is incorporated using a short section of no-core fiber, coated with tetraethyl orthosilicate and spliced at the end of a single mode fiber with a bulge. Different type...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.057001

    authors: Bhardwaj V,Pathak AK,Singh VK

    更新日期:2017-05-01 00:00:00

  • Optical redox imaging indices discriminate human breast cancer from normal tissues.

    abstract::Our long-term goal was to investigate the potential of incorporating redox imaging technique as a breast cancer (BC) diagnosis component to increase the positive predictive value of suspicious imaging finding and to reduce unnecessary biopsies and overdiagnosis. We previously found that precancer and cancer tissues in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.114003

    authors: Xu HN,Tchou J,Feng M,Zhao H,Li LZ

    更新日期:2016-11-01 00:00:00

  • Influence of the absorption behavior of sunscreens in the short-wavelength UV range (UVB) and the long-wavelength UV range (UVA) on the relation of the UVB absorption to sun protection factor.

    abstract::The absorption of filter substances in sunscreens, reducing the incident ultraviolet (UV) radiation, is the basis for the protecting ability of such formulations. The erythema-correlated sun protection factor (SPF), depending mainly on the intensity of the UVB radiation, is the common value to quantify the efficacy of...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3497047

    authors: Weigmann HJ,Schanzer S,Antoniou C,Sterry W,Lademann J

    更新日期:2010-09-01 00:00:00

  • Miniature endoscopic optical coherence tomography probe employing a two-axis microelectromechanical scanning mirror with through-silicon vias.

    abstract::We present the design and experimental results of a new MEMS-based endoscopic optical coherence tomography (OCT) probe. The uniqueness of this miniature OCT imaging probe is a two-axis MEMS mirror with through-silicon vias (TSVs) for interconnecting. The TSV interconnection enables ultracompact probe design, successfu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3533323

    authors: Liu L,Wu L,Sun J,Lin E,Xie H

    更新日期:2011-02-01 00:00:00

  • Near-infrared transmittance pulse oximetry with laser diodes.

    abstract::Pulse oximeters are widely used for noninvasive monitoring of oxygen saturation in arterial blood hemoglobin. We present a transmittance pulse oximetry system based on near-infrared (NIR) laser diodes (750 and 850 nm) for monitoring oxygen saturation of arterial blood hemoglobin. The pulse oximetry system is made up o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1578495

    authors: Lopez Silva SM,Dotor Castilla ML,Silveira Martin JP

    更新日期:2003-07-01 00:00:00

  • Quantitative real-time optical imaging of the tissue metabolic rate of oxygen consumption.

    abstract::The tissue metabolic rate of oxygen consumption (tMRO2) is a clinically relevant marker for a number of pathologies including cancer and arterial occlusive disease. We present and validate a noncontact method for quantitatively mapping tMRO2 over a wide, scalable field of view at 16  frames  /  s. We achieve this by d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.036013

    authors: Ghijsen M,Lentsch GR,Gioux S,Brenner M,Durkin AJ,Choi B,Tromberg BJ

    更新日期:2018-03-01 00:00:00

  • Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography.

    abstract::A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon fl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1383062

    authors: Torikoshi M,Tsunoo T,Endo M,Noda K,Kumada M,Yamada S,Soga F,Hyodo K

    更新日期:2001-07-01 00:00:00

  • Enhancement factor in low-coherence enhanced backscattering and its applications for characterizing experimental skin carcinogenesis.

    abstract::We experimentally study potential mechanisms by which the enhancement factor in low-coherence enhanced backscattering (LEBS) can probe subtle variations in radial intensity distribution in weakly scattering media. We use enhanced backscattering of light by implementing either (1) low spatial coherence illumination or ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3443795

    authors: Liu J,Xu Z,Song Q,Konger RL,Kim YL

    更新日期:2010-05-01 00:00:00

  • Processing algorithms for tracking speckle shifts in optical elastography of biological tissues.

    abstract::Parametric and nonparametric data processing schemes for analyzing translating laser speckle data used to investigate the mechanical behavior of biological tissues are examined. Cross-correlation, minimum mean square estimator, maximum likelihood, and maximum entropy approaches are discussed and compared on speckle da...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1412224

    authors: Duncan DD,Kirkpatrick SJ

    更新日期:2001-10-01 00:00:00

  • Ethidium bromide as a marker of mtDNA replication in living cells.

    abstract::Mitochondrial DNA (mtDNA) in tumor cells was found to play an important role in maintaining the malignant phenotype. Using laser scanning confocal fluorescence microscopy (LSCFM) in a recent work, we reported a variable fluorescence intensity of ethidium bromide (EB) in mitochondria nucleoids of living carcinoma cells...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.4.046001

    authors: Villa AM,Fusi P,Pastori V,Amicarelli G,Pozzi C,Adlerstein D,Doglia SM

    更新日期:2012-04-01 00:00:00