Correlation of functional and resting state connectivity of cerebral oxy-, deoxy-, and total hemoglobin concentration changes measured by near-infrared spectrophotometry.

Abstract:

:The aim is to study cerebral vascular functional connectivity during motor tasks and resting state using multichannel frequency-domain near-infrared spectrophotometry. Maps of 5.7 × 10.8 cm size displaying changes in cerebral oxyhemoglobin (O(2)Hb), deoxyhemoglobin (HHb), and total hemoglobin (tHb) concentrations were measured in the motor cortex in 12 subjects (mean age of 28.8±12.7 yrs) during resting state and during two palm squeezing tasks with different timing. For each condition, phase plane plots, cross correlation functions, and connectivity indices were generated for O(2)Hb, HHb, and tHb. The amplitude of the concentration changes in O(2)Hb and HHb depends on the age of the subject. We found large regions of connectivity, which were similar for resting state and task conditions. This means the spatial relationships during resting state, when changes in O(2)Hb, HHb, and tHb corresponded to spontaneous oscillations, were correlated to the spatial patterns during the activation tasks, when changes in O(2)Hb, HHb, and tHb concentration were related to the alternation of stimulation and rest. Thus, the vascular functional connectivity was also present during resting state. The findings suggest that the vascular response to functional activation may be a nonlinear synchronization phenomenon and that resting state processes are more important than previously expected.

journal_name

J Biomed Opt

authors

Wolf U,Toronov V,Choi JH,Gupta R,Michalos A,Gratton E,Wolf M

doi

10.1117/1.3615249

subject

Has Abstract

pub_date

2011-08-01 00:00:00

pages

087013

issue

8

eissn

1083-3668

issn

1560-2281

journal_volume

16

pub_type

杂志文章
  • Perspective review on applications of optics in spinal surgery.

    abstract::Optical technologies may be applied to multiple facets of spinal surgery from diagnostics to intraoperative image guidance to therapeutics. In diagnostics, the current standard remains cross-sectional static imaging. Optical surface scanning tools may have an important role; however, significant work is required to cl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.23.6.060601

    authors: Guha D,Yang VXD

    更新日期:2018-06-01 00:00:00

  • Acoustic attenuation compensation in photoacoustic tomography using time-variant filtering.

    abstract::Most reconstruction algorithms used in photoacoustic tomography do not account for the effects of acoustic attenuation on the recorded signals. For experimental measurements made in biological tissue, the frequency dependent acoustic attenuation causes high frequency components of the propagating photoacoustic waves t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036008

    authors: Treeby BE

    更新日期:2013-03-01 00:00:00

  • System analysis of spatial frequency domain imaging for quantitative mapping of surgically resected breast tissues.

    abstract::The feasibility of spatial frequency domain imaging (SFDI) for breast surgical margin assessment was evaluated in tissue-simulating phantoms and in fully intact lumpectomy specimens at the time of surgery. Phantom data was evaluated according to contrast-detail resolution, quantitative accuracy and model-data goodness...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036012

    authors: Laughney AM,Krishnaswamy V,Rice TB,Cuccia DJ,Barth RJ,Tromberg BJ,Paulsen KD,Pogue BW,Wells WA

    更新日期:2013-03-01 00:00:00

  • Combining casein phosphopeptide-amorphous calcium phosphate with fluoride: synergistic remineralization potential of artificially demineralized enamel or not?

    abstract::Recaldent is a product of casein phosphopeptide-amorphous calcium phosphate (CPP-ACP). The remineralizing potential of CPP-ACP per se, or when combined with 0.22% Fl gel on artificially demineralized enamel using laser florescence, is investigated. Mesial surfaces of 15 sound human molars are tested using a He-Cd lase...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3210780

    authors: Elsayad I,Sakr A,Badr Y

    更新日期:2009-07-01 00:00:00

  • Protein conformation and molecular order probed by second-harmonic-generation microscopy.

    abstract::Second-harmonic-generation (SHG) microscopy has emerged as a powerful tool to image unstained living tissues and probe their molecular and supramolecular organization. In this article, we review the physical basis of SHG, highlighting how coherent summation of second-harmonic response leads to the sensitivity of polar...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.17.6.060901

    authors: Vanzi F,Sacconi L,Cicchi R,Pavone FS

    更新日期:2012-06-01 00:00:00

  • Quantitative phase microscopy of articular chondrocyte dynamics by wide-field digital interferometry.

    abstract::We experimentally implement label-free phase microscopy using wide-field digital interferometry (WFDI) techniques to retrieve quantitative volumetric data of articular chondrocyte dynamics. Using the scanless interferometric system, we visualize chondrocyte swelling and bursting induced by hypo-osmotic pressure. Recon...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3290242

    authors: Shaked NT,Finan JD,Guilak F,Wax A

    更新日期:2010-01-01 00:00:00

  • Noninvasive monitoring of hemodynamic stress using quantitative near-infrared frequency-domain photon migration spectroscopy.

    abstract::Hemorrhagic hypovolemia and inotropic agent administration were used to manipulate cardiac output (CO) and oxygen delivery in rabbits to investigate the correlation between noninvasive frequency domain photon migration (FDPM) spectroscopy and invasive hemodynamic monitoring parameters. Frequency-domain photon migratio...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1427046

    authors: Pham TH,Hornung R,Ha HP,Burney T,Serna D,Powell L,Brenner M,Tromberg BJ

    更新日期:2002-01-01 00:00:00

  • Discovery of the near-infrared window into the body and the early development of near-infrared spectroscopy.

    abstract::Extension of optical monitoring of intact tissues from the visible and ultraviolet to the near-infrared (NIR) range (700-1300 nm) was first undertaken in 1977 for the purpose of monitoring the redox behavior of Cytochrome c oxidase (cyt c ox) in vivo. Soon it became evident that the much greater NIR translucency of sk...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429952

    authors: Jo Bsis-Vandervliet FF

    更新日期:1999-10-01 00:00:00

  • Monitoring hemodynamic and morphologic responses to closed head injury in a mouse model using orthogonal diffuse near-infrared light reflectance spectroscopy.

    abstract::The authors' aim is to assess and quantitatively measure brain hemodynamic and morphological variations during closed-head injury (CHI) in mice using orthogonal diffuse near-infrared reflectance spectroscopy (o-DRS). CHI is a type of injury to the head that does not penetrate the skull. Usually, it is caused by mechan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.4.045003

    authors: Abookasis D,Shochat A,Mathews MS

    更新日期:2013-04-01 00:00:00

  • Functional imaging of dye concentration in tissue phantoms by spectroscopic optical coherence tomography.

    abstract::We present functional imaging of the concentration of a photodynamic therapy (PDT)-related dye in scattering tissue phantoms based on spatially resolved measurements of optical properties through spectroscopic optical coherence tomography (OCT). Expressions for the OCT signal are developed, enabling estimation of dept...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1898242

    authors: Støren T,Røyset A,Svaasand LO,Lindmo T

    更新日期:2005-03-01 00:00:00

  • Oblique incidence reflectometry: optical models and measurements using a side-viewing gradient index lens-based endoscopic imaging system.

    abstract::A side-viewing, 2.3-mm diameter oblique incidence reflectometry endoscope has been designed to obtain optical property measurements of turbid samples. Light from a single-mode fiber is relayed obliquely onto the tissue with a gradient index lens-based distal optics assembly and the resulting diffuse reflectance profil...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.6.067002

    authors: Wall RA,Barton JK

    更新日期:2014-06-01 00:00:00

  • Confocal fluorescence microscope with dual-axis architecture and biaxial postobjective scanning.

    abstract::We present a novel confocal microscope that has dual-axis architecture and biaxial postobjective scanning for the collection of fluorescence images from biological specimens. This design uses two low-numerical-aperture lenses to achieve high axial resolution and long working distance, and the scanning mirror located d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1760760

    authors: Wang TD,Contag CH,Mandella MJ,Chan NY,Kino GS

    更新日期:2004-07-01 00:00:00

  • Photoacoustic microscopy of blood pulse wave.

    abstract::Blood pulse wave velocity (PWV) is an important physiological parameter that characterizes vascular stiffness. In this letter, we present electrocardiogram-synchronized, photoacoustic microscopy for noninvasive quantification of the PWV in the peripheral vessels of living mice. Interestingly, blood pulse wave-induced ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.7.070504

    authors: Yeh C,Hu S,Maslov K,Wang LV

    更新日期:2012-07-01 00:00:00

  • Holographic analysis on deformation and restoration of malaria-infected red blood cells by antimalarial drug.

    abstract::Malaria parasites induce morphological, biochemical, and mechanical changes in red blood cells (RBCs). Mechanical variations are closely related to the deformability of individual RBCs. The deformation of various RBCs, including healthy and malaria-infected RBCs (iRBCs), can be directly observed through quantitative p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.11.115003

    authors: Byeon H,Ha YR,Lee SJ

    更新日期:2015-11-01 00:00:00

  • Light propagation in a turbid medium with insonified microbubbles.

    abstract::Surfactant stabilized microbubbles are widely used clinical contrast agents for ultrasound imaging. In this work, the light propagation through a turbid medium in the presence of microbubbles has been investigated. Through a series of experiments, it has been found that the optical attenuation is increased when the mi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.015002

    authors: Leung TS,Honeysett JE,Stride E,Deng J

    更新日期:2013-01-01 00:00:00

  • Noninvasive optoacoustic temperature determination at the fundus of the eye during laser irradiation.

    abstract::In all fundus laser treatments of the eye, the temperature increase is not exactly known. In order to optimize treatments, an online temperature determination is preferable. We investigated a noninvasive optoacoustic method to monitor the fundus temperature during pulsed laser irradiation. When laser pulses are applie...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1627338

    authors: Schule G,Huttmann G,Framme C,Roider J,Brinkmann R

    更新日期:2004-01-01 00:00:00

  • Eigenvector-based spatial filtering for reduction of physiological interference in diffuse optical imaging.

    abstract::Diffuse optical imaging is an effective technique for noninvasive functional brain imaging. However, the measurements respond to systemic hemodynamic fluctuations caused by the cardiac cycle, respiration, and blood pressure, which may obscure or overwhelm the desired stimulus-evoked response. Previous work on this pro...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1852552

    authors: Zhang Y,Brooks DH,Franceschini MA,Boas DA

    更新日期:2005-01-01 00:00:00

  • Clinical study of noninvasive in vivo melanoma and nonmelanoma skin cancers using multimodal spectral diagnosis.

    abstract::The goal of this study was to determine the diagnostic capability of a multimodal spectral diagnosis (SD) for in vivo noninvasive disease diagnosis of melanoma and nonmelanoma skin cancers. We acquired reflectance, fluorescence, and Raman spectra from 137 lesions in 76 patients using custom-built optical fiber-based c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.117003

    authors: Lim L,Nichols B,Migden MR,Rajaram N,Reichenberg JS,Markey MK,Ross MI,Tunnell JW

    更新日期:2014-01-01 00:00:00

  • Three-dimensional optical coherence tomography at 1050 nm versus 800 nm in retinal pathologies: enhanced performance and choroidal penetration in cataract patients.

    abstract::Frequency domain optical coherence tomography (FD-OCT), based on an all-reflective high-speed InGaAs spectrometer, operating in the 1050 nm wavelength region for retinal diagnostics, enables high-speed, volumetric imaging of retinal pathologies with greater penetration into choroidal tissue is compared to conventional...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2773728

    authors: Povazay B,Hermann B,Unterhuber A,Hofer B,Sattmann H,Zeiler F,Morgan JE,Falkner-Radler C,Glittenberg C,Blinder S,Drexler W

    更新日期:2007-07-01 00:00:00

  • Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror.

    abstract::A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8×0.8  mm2 mirror plate...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.8.086005

    authors: Wang D,Fu L,Wang X,Gong Z,Samuelson S,Duan C,Jia H,Ma JS,Xie H

    更新日期:2013-08-01 00:00:00

  • Quantitative concentration measurements of creatinine dissolved in water and urine using Raman spectroscopy and a liquid core optical fiber.

    abstract::We describe the use of a Teflon-AF liquid core optical fiber (LCOF) geometry to enhance the collection of Raman scattering from the biochemical creatinine, dissolved in water and in urine. At short integration times, where shot noise is most troublesome, the enhanced signal leads to greater accuracy in estimating the ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1917842

    authors: Qi D,Berger AJ

    更新日期:2005-05-01 00:00:00

  • Label-free separation of human embryonic stem cells and their differentiating progenies by phasor fluorescence lifetime microscopy.

    abstract::We develop a label-free optical technique to image and discriminate undifferentiated human embryonic stem cells (hESCs) from their differentiating progenies in vitro. Using intrinsic cellular fluorophores, we perform fluorescence lifetime microscopy (FLIM) and phasor analysis to obtain hESC metabolic signatures. We id...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.4.046012

    authors: Stringari C,Sierra R,Donovan PJ,Gratton E

    更新日期:2012-04-01 00:00:00

  • Modulated electron-multiplied fluorescence lifetime imaging microscope: all-solid-state camera for fluorescence lifetime imaging.

    abstract::We have built an all-solid-state camera that is directly modulated at the pixel level for frequency-domain fluorescence lifetime imaging microscopy (FLIM) measurements. This novel camera eliminates the need for an image intensifier through the use of an application-specific charge coupled device design in a frequency-...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.jbo.17.12.126020

    authors: Zhao Q,Schelen B,Schouten R,van den Oever R,Leenen R,van Kuijk H,Peters I,Polderdijk F,Bosiers J,Raspe M,Jalink K,Geert Sander de Jong J,van Geest B,Stoop K,Young IT

    更新日期:2012-12-01 00:00:00

  • Rapid convergence to the inverse solution regularized with Lorentzian distributed function for near-infrared continuous wave diffuse optical tomography.

    abstract::A promising method to achieve rapid convergence for image reconstruction is introduced for the continuous-wave near-infrared (NIR) diffuse optical tomography (DOT). Tomographic techniques are usually implemented off line and are time consuming to realize image reconstruction, especially for NIR DOT. Therefore, it is e...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3299727

    authors: Pan MC,Pan MC

    更新日期:2010-01-01 00:00:00

  • Lipid-cell interactions in human monocytes investigated by doubly-resonant coherent anti-Stokes Raman scattering microscopy.

    abstract::We demonstrate that doubly-resonant coherent anti-Stokes Raman scattering can provide enhanced and highly specific contrast for molecules containing unique Raman-active small molecular groups. This combination provides contrast for molecules that can otherwise be difficult to discriminate by Raman spectroscopy. Here, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3544585

    authors: Weeks T,Schie I,den Hartigh LJ,Rutledge JC,Huser T

    更新日期:2011-02-01 00:00:00

  • Monitoring remineralization of enamel subsurface lesions by optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is a potential clinical tool for enamel lesion monitoring. Swept-source OCT findings were compared with cross-sectional nanohardness findings of enamel. Subsurface bovine enamel lesions in three groups were subjected to (1) deionized water (control), (2) phosphoryl oligosaccharide of...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.4.046006

    authors: Mandurah MM,Sadr A,Shimada Y,Kitasako Y,Nakashima S,Bakhsh TA,Tagami J,Sumi Y

    更新日期:2013-04-01 00:00:00

  • Reproducibility of parameters of postocclusive reactive hyperemia measured by diffuse optical tomography.

    abstract::The application of near-infrared spectroscopy (NIRS) to assess microvascular function has shown promising results. An important limitation when using a single source-detector pair, however, is the lack of depth sensitivity. Diffuse optical tomography (DOT) overcomes this limitation using an array of sources and detect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.6.066012

    authors: Vidal-Rosas EE,Billings SA,Chico T,Coca D

    更新日期:2016-06-01 00:00:00

  • Theory and practical recommendations for autocorrelation-based image correlation spectroscopy.

    abstract::Image correlation spectroscopy (ICS) is a powerful technique for detecting arrangement of fluorophores in images. This tutorial gives background into the mathematical underpinnings of ICS, specifically image autocorrelation. The effects of various artifacts and image processing steps, including background subtraction,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.080801

    authors: Robertson C,George SC

    更新日期:2012-08-01 00:00:00

  • Hybridized wavefront shaping for high-speed, high-efficiency focusing through dynamic diffusive media.

    abstract::One of the prime limiting factors of optical imaging in biological applications is the diffusion of light by tissue, which prevents focusing at depths greater than the optical diffusion limit (typically ?1??mm). To overcome this challenge, wavefront shaping techniques that use a spatial light modulator (SLM) to correc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.121502

    authors: Hemphill AS,Tay JW,Wang LV

    更新日期:2016-12-01 00:00:00

  • Intraoperative hyperspectral determination of human tissue properties.

    abstract::We address the automatic differentiation of human tissue using multispectral imaging with promising potential for automatic visualization during surgery. Currently, tissue types have to be continuously differentiated based on the surgeon's knowledge only. Further, automatic methods based on optical in vivo properties ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.091409

    authors: Wisotzky EL,Uecker FC,Arens P,Dommerich S,Hilsmann A,Eisert P

    更新日期:2018-05-01 00:00:00