Eigenvector-based spatial filtering for reduction of physiological interference in diffuse optical imaging.

Abstract:

:Diffuse optical imaging is an effective technique for noninvasive functional brain imaging. However, the measurements respond to systemic hemodynamic fluctuations caused by the cardiac cycle, respiration, and blood pressure, which may obscure or overwhelm the desired stimulus-evoked response. Previous work on this problem employed temporal filtering, estimation of systemic effects from background pixels, or modeling of interference signals with predefined basis functions, with some success. However, weak signals are still lost in the interference, and other complementary methods are desirable. We use the spatial behavior of measured baseline signals to identify the interference subspaces. We then project signals components in this subspace out of the stimulation data. In doing so, we assume that systemic interference components will be more global spatially, with higher energy, than the stimulus-evoked signals of interest. Thus, the eigenvectors corresponding to the largest eigenvalues of an appropriate correlation matrix form the basis for an interference subspace. By projecting the data onto the orthogonal nullspace of these eigenvectors, we can obtain more localized response, as reflected in improved contrast-to-noise ratio and correlation coefficient maps.

journal_name

J Biomed Opt

authors

Zhang Y,Brooks DH,Franceschini MA,Boas DA

doi

10.1117/1.1852552

subject

Has Abstract

pub_date

2005-01-01 00:00:00

pages

11014

issue

1

eissn

1083-3668

issn

1560-2281

journal_volume

10

pub_type

杂志文章
  • Optically sectioned in vivo imaging with speckle illumination HiLo microscopy.

    abstract::We present a simple wide-field imaging technique, called HiLo microscopy, that is capable of producing optically sectioned images in real time, comparable in quality to confocal laser scanning microscopy. The technique is based on the fusion of two raw images, one acquired with speckle illumination and another with st...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3528656

    authors: Lim D,Ford TN,Chu KK,Mertz J

    更新日期:2011-01-01 00:00:00

  • Photochemical effects and hypericin photosensitized processes in collagen.

    abstract::Emission and excitation spectra of collagen were recorded in the ultraviolet and visible regions. The existence of several types of chromophores absorbing and emitting throughout these spectral regions was observed. It was shown that laser irradiation at 355 and 532 nm caused collagen fluorescence photobleaching by 30...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1331559

    authors: Yova D,Hovhannisyan V,Theodossiou T

    更新日期:2001-01-01 00:00:00

  • Detection of canine skin and subcutaneous tumors by visible and near-infrared diffuse reflectance spectroscopy.

    abstract::Cancer is the main cause of canine morbidity and mortality. The existing evaluation of tumors requires an experienced veterinarian and usually includes invasive procedures (e.g., fine-needle aspiration) that can be unpleasant for the dog and the owner. We investigate visible and near-infrared diffuse reflectance spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.3.037003

    authors: Cugmas B,Plavec T,Bregar M,Naglič P,Pernuš F,Likar B,Bürmen M

    更新日期:2015-03-01 00:00:00

  • Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology.

    abstract::We present a novel Fourier-domain angle-resolved low-coherence interferometry (a /LCI) fiber probe designed for in vivo clinical application in gastrointestinal endoscopy. The a/LCI technique measures the depth-resolved angular scattering distribution to determine the size distribution and optical density of cell nucl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3520130

    authors: Zhu Y,Terry NG,Woosley JT,Shaheen NJ,Wax A

    更新日期:2011-01-01 00:00:00

  • Real-time brightfield, darkfield, and phase contrast imaging in a light-emitting diode array microscope.

    abstract::We demonstrate a single-camera imaging system that can simultaneously acquire brightfield, darkfield, and phase contrast images in real time. Our method uses computational illumination via a programmable light-emitting diode (LED) array at the source plane, providing flexible patterning of illumination angles. Brightf...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106002

    authors: Liu Z,Tian L,Liu S,Waller L

    更新日期:2014-01-01 00:00:00

  • Bleaching of plasmon-resonance absorption of gold nanorods decreases efficiency of cell destruction.

    abstract::When irradiated with nanosecond laser pulses, gold nanoparticles allow for manipulation or destruction of cells and proteins with high spatial and temporal precision. Gold nanorods are especially attractive, because they have an up-to-20-fold stronger absorption than a sphere of equal volume, which is shifted to the o...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.058003

    authors: Rudnitzki F,Bever M,Rahmanzadeh R,Brieger K,Endl E,Groll J,Hüttmann G

    更新日期:2012-05-01 00:00:00

  • Surface-enhanced Raman spectroscopy of tears: toward a diagnostic tool for neurodegenerative disease identification.

    abstract:SIGNIFICANCE:A noninvasive method based on surface-enhanced Raman spectroscopy (SERS) of tears was proposed as a support for diagnosing neurodegenerative pathologies, including different forms of dementia and Alzheimer's disease (AD). In this field, timely and reliable discrimination and diagnosis are critical aspects ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.8.087002

    authors: Cennamo G,Montorio D,Morra VB,Criscuolo C,Lanzillo R,Salvatore E,Camerlingo C,Lisitskiy M,Delfino I,Portaccio M,Lepore M

    更新日期:2020-08-01 00:00:00

  • Subcellular imaging of epithelium with time-lapse optical coherence tomography.

    abstract::We present the first experimental result of direct delineation of the nuclei of living rat bladder epithelium with ultrahigh-resolution optical coherence tomography (uOCT). We demonstrate that the cellular details embedded in the speckle noise in a uOCT image can be uncovered by time-lapse frame averaging that takes a...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.2800007

    authors: Pan YT,Wu ZL,Yuan ZJ,Wang ZG,Du CW

    更新日期:2007-09-01 00:00:00

  • Differential optical spectropolarimetric imaging system assisted by liquid crystal devices for skin imaging.

    abstract::Skin cancer diagnosis depends not only on histopathological examination but also on visual inspection before and after the excision of suspected lesion. Neoplasm is accompanied with changes in birefringence of collagen, pleomorphicity, and hyperchromatic state of epithelial nuclei. These phenomena can be measured by s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3609003

    authors: Aharon O,Abdulhalim I,Arnon O,Rosenberg L,Dyomin V,Silberstein E

    更新日期:2011-08-01 00:00:00

  • Changes induced by peripheral nerve injury in the morphology and nanomechanics of sensory neurons.

    abstract::Peripheral nerve injury in vivo promotes a regenerative growth in vitro characterized by an improved neurite regrowth. Knowledge of the conditioning injury effects on both morphology and mechanical properties of live sensory neurons could be instrumental to understand the cellular and molecular mechanisms leading to t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.106014

    authors: Benzina O,Szabo V,Lucas O,Saab MB,Cloitre T,Scamps F,Gergely C,Martin M

    更新日期:2013-10-01 00:00:00

  • Quantitative fluorescence imaging of protoporphyrin IX through determination of tissue optical properties in the spatial frequency domain.

    abstract::The ability to quantitatively determine tissue fluorescence is of interest for the purpose of better understanding the details of photodynamic therapy of skin cancer. In particular, we are interested in quantifying protoporphyrin IX (PpIX) in vivo. We present a method of correcting fluorescence for effects of native t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3665440

    authors: Saager RB,Cuccia DJ,Saggese S,Kelly KM,Durkin AJ

    更新日期:2011-12-01 00:00:00

  • Low-frequency wide-field fluorescence lifetime imaging using a high-power near-infrared light-emitting diode light source.

    abstract::Fluorescence lifetime imaging (FLi) could potentially improve exogenous near-infrared (NIR) fluorescence imaging, because it offers the capability of discriminating a signal of interest from background, provides real-time monitoring of a chemical environment, and permits the use of several different fluorescent dyes h...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3368997

    authors: Gioux S,Lomnes SJ,Choi HS,Frangioni JV

    更新日期:2010-03-01 00:00:00

  • Dynamic in vivo imaging of small animal brain using pulsed laser diode-based photoacoustic tomography system.

    abstract::We demonstrate dynamic in vivo imaging using a low-cost portable pulsed laser diode (PLD)-based photoacoustic tomography system. The system takes advantage of an 803-nm PLD having high-repetition rate ∼7000  Hz combined with a fast-scanning single-element ultrasound transducer leading to a 5 s cross-sectional imaging....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.090501

    authors: Upputuri PK,Pramanik M

    更新日期:2017-09-01 00:00:00

  • Ultrasensitive opto-microfluidic immunosensor integrating gold nanoparticle-enhanced chemiluminescence and highly stable organic photodetector.

    abstract::The expensive fabrication of current opto-microfluidic sensors is a barrier to the successful adoption of these devices in point-of-care testing. This work reports a simple inexpensive opto-microfluidic device incorporating a poly(dimethylsiloxane)-glass hybrid microfluidic chip modified with gold nanoparticles and a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.3.030504

    authors: Pires NM,Dong T

    更新日期:2014-03-01 00:00:00

  • Characterization of natural and irradiated nails by means of the depolarization metrics.

    abstract::Mueller polarimetry is applied to study the samples of nails: natural (or reference) and irradiated to 2 Gy ionizing radiation dose. We measure the whole Mueller matrices of the samples as a function of the scattering angle at a wavelength of 632.8 nm. We apply depolarization analysis to measured Mueller matrices by c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.7.071108

    authors: Savenkov S,Priezzhev A,Oberemok Y,Sholom S,Kolomiets I,Chunikhina K

    更新日期:2016-07-01 00:00:00

  • Chemical reactivation of fluorescein isothiocyanate immunofluorescence-labeled resin-embedded samples.

    abstract::Resin embedding is widely used and facilitates microscopic imaging of biological tissues. In contrast, quenching of fluorescence during embedding process hinders the application of resin embedding for imaging of fluorescence-labeled samples. For samples expressing fluorescent proteins, it has been demonstrated that th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.2.020501

    authors: Li L,Rao G,Lv X,Chen R,Cheng X,Wang X,Zeng S,Liu X

    更新日期:2018-02-01 00:00:00

  • Virtual organelle self-coding for fluorescence imaging via adversarial learning.

    abstract:SIGNIFICANCE:Our study introduces an application of deep learning to virtually generate fluorescence images to reduce the burdens of cost and time from considerable effort in sample preparation related to chemical fixation and staining. AIM:The objective of our work was to determine how successfully deep learning meth...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.9.096009

    authors: Nguyen T,Bui V,Thai A,Lam V,Raub C,Chang LC,Nehmetallah G

    更新日期:2020-09-01 00:00:00

  • Pulsed versus continuous wave low-level light therapy on osteoarticular signs and symptoms in limited scleroderma (CREST syndrome): a case report.

    abstract::Limited cutaneous systemic sclerosis (lcSSc) was formerly known as CREST syndrome in reference to the associated clinical features: calcinosis, Raynaud's phenomenon, esophageal dysfunction, sclerodactyly, and telangiectasias. The transforming growth factor beta has been identified as a major player in the pathogenic p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.11.118001

    authors: Barolet D

    更新日期:2014-01-01 00:00:00

  • Perspective review on applications of optics in spinal surgery.

    abstract::Optical technologies may be applied to multiple facets of spinal surgery from diagnostics to intraoperative image guidance to therapeutics. In diagnostics, the current standard remains cross-sectional static imaging. Optical surface scanning tools may have an important role; however, significant work is required to cl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.23.6.060601

    authors: Guha D,Yang VXD

    更新日期:2018-06-01 00:00:00

  • Optical detection of intracellular cavitation during selective laser targeting of the retinal pigment epithelium: dependence of cell death mechanism on pulse duration.

    abstract::Selective laser targeting of the retinal pigment epithelium (RPE) is an attractive method for treating RPE-associated disorders. We are developing a method for optically detecting intracellular microcavitation that can potentially serve as an immediate feedback of the treatment outcome. Thermal denaturation or intrace...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2804078

    authors: Lee H,Alt C,Pitsillides CM,Lin CP

    更新日期:2007-11-01 00:00:00

  • No-core fiber-based highly sensitive optical fiber pH sensor.

    abstract::The present work describes the fabrication and characterization of an optical fiber pH sensor using a sol–gel technique. The sensing head configuration is incorporated using a short section of no-core fiber, coated with tetraethyl orthosilicate and spliced at the end of a single mode fiber with a bulge. Different type...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.057001

    authors: Bhardwaj V,Pathak AK,Singh VK

    更新日期:2017-05-01 00:00:00

  • Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.

    abstract::This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.8.087001

    authors: Al-Fakih E,Arifin N,Pirouzi G,Mahamd Adikan FR,Shasmin HN,Abu Osman NA

    更新日期:2017-08-01 00:00:00

  • Early detection of colorectal cancer relapse by infrared spectroscopy in "normal" anastomosis tissue.

    abstract::Colorectal cancer is one of the most aggressive cancers usually occurring in people above the age of 50 years. In the United States, colorectal cancer is the third most diagnosed cancer. The American Cancer Society has estimated 96,830 new cases of colon cancer and 40,000 new cases of rectal cancer in 2014 in the Unit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075007

    authors: Salman A,Sebbag G,Argov S,Mordechai S,Sahu RK

    更新日期:2015-07-01 00:00:00

  • Cutaneous melanin exhibiting fluorescence emission under near-infrared light excitation.

    abstract::Under ultraviolet and visible light excitation, melanin is essentially a nonfluorescent substance. This work reports our study on near-infrared (NIR) fluorescence properties of melanins, and explores potential applications of NIR fluorescence techniques for evaluating skin disorders involving melanin. The NIR fluoresc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2204007

    authors: Huang Z,Zeng H,Hamzavi I,Alajlan A,Tan E,McLean DI,Lui H

    更新日期:2006-05-01 00:00:00

  • Evaluation of hypericin-mediated photodynamic therapy in combination with angiogenesis inhibitor bevacizumab using in vivo fluorescence confocal endomicroscopy.

    abstract::Photodynamic therapy (PDT) is an alternative cancer treatment modality that offers localized treatment using a photosensitizer and light. However, tumor angiogenesis is a major concern following PDT-induced hypoxia as it promotes recurrence. Bevacizumab is a monoclonal antibody that targets vascular endothelial growth...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3281671

    authors: Bhuvaneswari R,Thong PS,Gan YY,Soo KC,Olivo M

    更新日期:2010-01-01 00:00:00

  • New aspects in assessment of changes in width of subarachnoid space with near-infrared transillumination-backscattering sounding, part 2: clinical verification in the patient.

    abstract::The study presents comparison of near-infrared light propagation and near-infrared backscattered radiation power, as simulated with numerical modeling and measured live in a patient in clinical conditions with the use of the near-infrared transillumination-backscattering sounding (NIR-TBSS) technique. A unique chance ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2753756

    authors: Frydrychowski AF,Pluciński J

    更新日期:2007-07-01 00:00:00

  • Dynamics of retinal photocoagulation and rupture.

    abstract::In laser retinal photocoagulation, short (<20 ms) pulses have been found to reduce thermal damage to the inner retina, decrease treatment time, and minimize pain. However, the safe therapeutic window (defined as the ratio of power for producing a rupture to that of mild coagulation) decreases with shorter exposures. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3130282

    authors: Sramek C,Paulus Y,Nomoto H,Huie P,Brown J,Palanker D

    更新日期:2009-05-01 00:00:00

  • Toward the clinical application of time-domain fluorescence lifetime imaging.

    abstract::High-speed (video-rate) fluorescence lifetime imaging (FLIM) through a flexible endoscope is reported based on gated optical image intensifier technology. The optimization and potential application of FLIM to tissue autofluorescence for clinical applications are discussed. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2102807

    authors: Munro I,McGinty J,Galletly N,Requejo-Isidro J,Lanigan PM,Elson DS,Dunsby C,Neil MA,Lever MJ,Stamp GW,French PM

    更新日期:2005-09-01 00:00:00

  • Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope.

    abstract::A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fib...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.086003

    authors: Wall RA,Barton JK

    更新日期:2012-08-01 00:00:00

  • Video-rate optical flow corrected intraoperative functional fluorescence imaging.

    abstract::Intraoperative fluorescence molecular imaging based on targeted fluorescence agents is an emerging approach to improve surgical and endoscopic imaging and guidance. Short exposure times per frame and implementation at video rates are necessary to provide continuous feedback to the physician and avoid motion artifacts....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046012

    authors: Koch M,Glatz J,Ermolayev V,de Vries EG,van Dam GM,Englmeier KH,Ntziachristos V

    更新日期:2014-04-01 00:00:00