Low-frequency wide-field fluorescence lifetime imaging using a high-power near-infrared light-emitting diode light source.

Abstract:

:Fluorescence lifetime imaging (FLi) could potentially improve exogenous near-infrared (NIR) fluorescence imaging, because it offers the capability of discriminating a signal of interest from background, provides real-time monitoring of a chemical environment, and permits the use of several different fluorescent dyes having the same emission wavelength. We present a high-power, LED-based, NIR light source for the clinical translation of wide-field (larger than 5 cm in diameter) FLi at frequencies up to 35 MHz. Lifetime imaging of indocyanine green (ICG), IRDye 800-CW, and 3,3(')-diethylthiatricarbocyanine iodide (DTTCI) was performed over a large field of view (10 cm by 7.5 cm) using the LED light source. For comparison, a laser diode light source was employed as a gold standard. Experiments were performed both on the bench by diluting the fluorescent dyes in various chemical environments in Eppendorf tubes, and in vivo by injecting the fluorescent dyes mixed in Matrigel subcutaneously into CD-1 mice. Last, measured fluorescence lifetimes obtained using the LED and the laser diode sources were compared with those obtained using a state-of-the-art time-domain imaging system and with those previously described in the literature. On average, lifetime values obtained using the LED and the laser diode light sources were consistent, exhibiting a mean difference of 3% from the expected values and a coefficient of variation of 12%. Taken together, our study offers an alternative to laser diodes for clinical translation of FLi and explores the use of relatively low frequency modulation for in vivo imaging.

journal_name

J Biomed Opt

authors

Gioux S,Lomnes SJ,Choi HS,Frangioni JV

doi

10.1117/1.3368997

subject

Has Abstract

pub_date

2010-03-01 00:00:00

pages

026005

issue

2

eissn

1083-3668

issn

1560-2281

journal_volume

15

pub_type

杂志文章
  • Deep learning-level melanoma detection by interpretable machine learning and imaging biomarker cues.

    abstract:SIGNIFICANCE:Melanoma is a deadly cancer that physicians struggle to diagnose early because they lack the knowledge to differentiate benign from malignant lesions. Deep machine learning approaches to image analysis offer promise but lack the transparency to be widely adopted as stand-alone diagnostics. AIM:We aimed to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.11.112906

    authors: Gareau DS,Browning J,Correa Da Rosa J,Suarez-Farinas M,Lish S,Zong AM,Firester B,Vrattos C,Renert-Yuval Y,Gamboa M,Vallone MG,Barragán-Estudillo ZF,Tamez-Peña AL,Montoya J,Jesús-Silva MA,Carrera C,Malvehy J,Puig S,Mar

    更新日期:2020-11-01 00:00:00

  • Raman spectroscopy of in vivo cutaneous melanin.

    abstract::We successfully acquire the in vivo Raman spectrum of melanin from human skin using a rapid near-infrared (NIR) Raman spectrometer. The Raman signals of in vivo cutaneous melanin are similar to those observed from natural and synthetic eumelanins. The melanin Raman spectrum is dominated by two intense and broad peaks ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1805553

    authors: Huang Z,Lui H,Chen XK,Alajlan A,McLean DI,Zeng H

    更新日期:2004-11-01 00:00:00

  • Monitoring hemodynamic and morphologic responses to closed head injury in a mouse model using orthogonal diffuse near-infrared light reflectance spectroscopy.

    abstract::The authors' aim is to assess and quantitatively measure brain hemodynamic and morphological variations during closed-head injury (CHI) in mice using orthogonal diffuse near-infrared reflectance spectroscopy (o-DRS). CHI is a type of injury to the head that does not penetrate the skull. Usually, it is caused by mechan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.4.045003

    authors: Abookasis D,Shochat A,Mathews MS

    更新日期:2013-04-01 00:00:00

  • Hybridized wavefront shaping for high-speed, high-efficiency focusing through dynamic diffusive media.

    abstract::One of the prime limiting factors of optical imaging in biological applications is the diffusion of light by tissue, which prevents focusing at depths greater than the optical diffusion limit (typically ?1??mm). To overcome this challenge, wavefront shaping techniques that use a spatial light modulator (SLM) to correc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.121502

    authors: Hemphill AS,Tay JW,Wang LV

    更新日期:2016-12-01 00:00:00

  • In vivo simultaneous multispectral fluorescence imaging with spectral multiplexed volume holographic imaging system.

    abstract::A simultaneous multispectral fluorescence imaging system incorporating multiplexed volume holographic grating (VHG) is developed to acquire multispectral images of an object in one shot. With the multiplexed VHG, the imaging system can provide the distribution and spectral characteristics of multiple fluorophores in t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.6.060502

    authors: Lv Y,Zhang J,Zhang D,Cai W,Chen N,Luo J

    更新日期:2016-06-01 00:00:00

  • Optical reflectance assay for the detection of biofilm formation.

    abstract::We describe the protocol for an inexpensive and nondestructive optical reflectance assay for the measurement of biofilm formation. Reflectance data are obtained using an Ocean Optics (Dunedin, Florida) USB 2000 spectrometer with a polychromatic light source. A fiber optic cable is used both for illumination and collec...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1953347

    authors: Broschat SL,Loge FJ,Peppin JD,White D,Call DR,Kuhn E

    更新日期:2005-07-01 00:00:00

  • Curved array photoacoustic tomographic system for small animal imaging.

    abstract::We present systematic characterization of a photoacoustic imaging system optimized for rapid, high-resolution tomographic imaging of small animals. The system is based on a 128-element ultrasonic transducer array with a 5-MHz center frequency and 80% bandwidth shaped to a quarter circle of 25 mm radius. A 16-channel d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2907157

    authors: Gamelin J,Aguirre A,Maurudis A,Huang F,Castillo D,Wang LV,Zhu Q

    更新日期:2008-03-01 00:00:00

  • Macromolecular diffusion in the extracellular matrix measured by fluorescence correlation spectroscopy.

    abstract::Diffusion of therapeutic macromolecules through the extracellular matrix of tumor tissue is a crucial step in drug delivery. We use fluorescence correlation spectroscopy (FCS) to measure diffusion of IgG (150 kDa) and dextrans (155 kDa and 2 MDa) in solution, 5% gelatin hydrogel, and multicellular spheroids. Gel and s...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2982530

    authors: Reitan NK,Juthajan A,Lindmo T,de Lange Davies C

    更新日期:2008-09-01 00:00:00

  • Self-mixing in a diode laser as a method for cardiovascular diagnostics.

    abstract::Our aim is the development of a simple optical method for pulse wave profile, pulse wave delay time, and blood flow measurement. The method is based on recording the Doppler frequency shift related to a moving target--blood vessel walls or small particles. The Doppler signal is detected using the self-mixing that occu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1528949

    authors: Meigas K,Hinrikus H,Kattai R,Lass J

    更新日期:2003-01-01 00:00:00

  • Computational segmentation of collagen fibers from second-harmonic generation images of breast cancer.

    abstract::Second-harmonic generation (SHG) imaging can help reveal interactions between collagen fibers and cancer cells. Quantitative analysis of SHG images of collagen fibers is challenged by the heterogeneity of collagen structures and low signal-to-noise ratio often found while imaging collagen in tissue. The role of collag...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.016007

    authors: Bredfeldt JS,Liu Y,Pehlke CA,Conklin MW,Szulczewski JM,Inman DR,Keely PJ,Nowak RD,Mackie TR,Eliceiri KW

    更新日期:2014-01-01 00:00:00

  • Depth-sensitive reflectance measurements using obliquely oriented fiber probes.

    abstract::Computer simulation is used to facilitate the design of fiber-probe geometries that enable enhanced detection of optical signals arising from specific tissue depths. Obtaining understanding of the relationship between fiber-probe design and tissue interrogation is critical when developing strategies for optical detect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1989335

    authors: Wang AM,Bender JE,Pfefer J,Utzinger U,Drezek RA

    更新日期:2005-07-01 00:00:00

  • Evaluating the use of optical coherence tomography for the detection of epithelial cancers in vitro.

    abstract::Optical coherence tomography (OCT) is a noninvasive imaging methodology that is able to image tissue to depths of over 1 mm. Many epithelial conditions, such as melanoma and oral cancers, require an invasive biopsy for diagnosis. A noninvasive, real-time, point of care method of imaging depth-resolved epithelial struc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3652708

    authors: Smith LE,Hearnden V,Lu Z,Smallwood R,Hunter KD,Matcher SJ,Thornhill MH,Murdoch C,MacNeil S

    更新日期:2011-11-01 00:00:00

  • Reflectance confocal microscopy for characterization of mammary ductal structures and development of neoplasia in genetically engineered mouse models of breast cancer.

    abstract::The earliest steps of breast cancer begin with aberrations in mammary ductal structure. Techniques that enable an investigator to image in situ and then analyze the same tissue using biochemical tools facilitates identification of genetic networks and signaling pathways active in the imaged structure. Cellular confoca...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2065827

    authors: Parrish A,Halama E,Tilli MT,Freedman M,Furth PA

    更新日期:2005-09-01 00:00:00

  • Integration of a Raman spectroscopy system to a robotic-assisted surgical system for real-time tissue characterization during radical prostatectomy procedures.

    abstract::Surgical excision of the whole prostate through a radical prostatectomy procedure is part of the standard of care for prostate cancer. Positive surgical margins (cancer cells having spread into surrounding nonresected tissue) occur in as many as 1 in 5 cases and strongly correlate with disease recurrence and the requi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.025001

    authors: Pinto M,Zorn KC,Tremblay JP,Desroches J,Dallaire F,Aubertin K,Marple E,Kent C,Leblond F,Trudel D,Lesage F

    更新日期:2019-02-01 00:00:00

  • Time-resolved imaging of optical coefficients through murine chest cavities.

    abstract::As small animal optical imaging and tomography are gaining popularity for interrogating functional and molecular events in vivo, it becomes increasingly necessary to gain knowledge of the optical properties of the species investigated to better understand and describe photon propagation through their tissues. To achie...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2400702

    authors: Niedre MJ,Turner GM,Ntziachristos V

    更新日期:2006-11-01 00:00:00

  • Hyperspectral wide gap second derivative analysis for in vivo detection of cervical intraepithelial neoplasia.

    abstract::Hyperspectral reflectance imaging technique has been used for in vivo detection of cervical intraepithelial neoplasia. However, the clinical outcome of this technique is suboptimal owing to multiple limitations such as nonuniform illumination, high-cost and bulky setup, and time-consuming data acquisition and processi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.121303

    authors: Zheng W,Wang C,Chang S,Zhang S,Xu RX

    更新日期:2015-12-01 00:00:00

  • Evans blue dye-enhanced capillary-resolution photoacoustic microscopy in vivo.

    abstract::Complete and continuous imaging of microvascular networks is crucial for a wide variety of biomedical applications. Photoacoustic tomography can provide high resolution microvascular imaging using hemoglobin within red blood cells (RBCs) as an endogenic contrast agent. However, intermittent RBC flow in capillaries res...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3251044

    authors: Yao J,Maslov K,Hu S,Wang LV

    更新日期:2009-09-01 00:00:00

  • Average-power mediated ultrafast laser osteotomy using a mode-locked Nd:YVO4 laser oscillator.

    abstract::By using a novel temporal characterization technique, we determined that a threshold average laser power of 160 mW is required to drill through a 0.75-mm-thick cortical bone for a Nd:YVO(4) mode-locked laser oscillator with a peak intensity of 1.3 GWcm(2). The ablation mechanism is identified as average-power induced ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2821149

    authors: Lee YM,Tu RY,Chiang AC,Huang YC

    更新日期:2007-11-01 00:00:00

  • Monte Carlo simulations related to gas-based optical diagnosis of human sinusitis.

    abstract::We investigate the feasibility of using diode laser gas spectroscopy for sinusitis diagnostics. We simulate light propagation using the Monte Carlo concept, as implemented by the Advanced Systems Analysis Program (ASAP) software. Simulations and experimental data are compared for a model based on two scattering bodies...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2777179

    authors: Persson L,Kristensson E,Simonsson L,Svanberg S

    更新日期:2007-09-01 00:00:00

  • Temperature-modulated fluorescence tomography based on both concentration and lifetime contrast.

    abstract::It is challenging to image fluorescence objects with high spatial resolution in a highly scattering medium. Recently reported temperature-sensitive indocyanine green-loaded pluronic nanocapsules can potentially alleviate this problem. Here we demonstrate a frequency-domain temperature-modulated fluorescence tomography...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.056007

    authors: Lin Y,Kwong TC,Bolisay L,Gulsen G

    更新日期:2012-05-01 00:00:00

  • Three-dimensional optical method for integrated visualization of mouse islet microstructure and vascular network with subcellular-level resolution.

    abstract::Microscopic visualization of islets of Langerhans under normal and diabetic conditions is essential for understanding the pathophysiology of the disease. The intrinsic opacity of pancreata, however, limits optical accessibility for high-resolution light microscopy of islets in situ. Because the standard microtome-base...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3470241

    authors: Fu YY,Lu CH,Lin CW,Juang JH,Enikolopov G,Sibley E,Chiang AS,Tang SC

    更新日期:2010-07-01 00:00:00

  • Imaging performance of a miniature integrated microendoscope.

    abstract::An integrated miniature multi-modal microscope (4M device) for microendoscopy was built and tested. Imaging performance is evaluated and imaging results are presented for both fluorescence and reflectance samples. Images of biological samples show successful imaging of both thin layers of fixed cells prepared on a sli...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2978060

    authors: Rogers JD,Landau S,Tkaczyk TS,Descour MR,Rahman MS,Richards-Kortum R,Kärkäinen AH,Christenson T

    更新日期:2008-09-01 00:00:00

  • Analysis of red blood cell parameters by Talbot-projected fringes.

    abstract::Red blood cell (RBC) anomalies are significant symptoms for identification of health disorders and several blood diseases, which involve the modification of the parameters and biophysical characteristics of such cells. The aim of this study is to measure the three-dimensional phase information of healthy RBCs and thei...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.10.106009

    authors: Agarwal S,Kumar V,Shakher C

    更新日期:2017-10-01 00:00:00

  • In vivo near-infrared dual-axis confocal microendoscopy in the human lower gastrointestinal tract.

    abstract::Near-infrared confocal microendoscopy is a promising technique for deep in vivo imaging of tissues and can generate high-resolution cross-sectional images at the micron-scale. We demonstrate the use of a dual-axis confocal (DAC) near-infrared fluorescence microendoscope with a 5.5-mm outer diameter for obtaining clini...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.021102

    authors: Piyawattanametha W,Ra H,Qiu Z,Friedland S,Liu JT,Loewke K,Kino GS,Solgaard O,Wang TD,Mandella MJ,Contag CH

    更新日期:2012-02-01 00:00:00

  • Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror.

    abstract::A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8×0.8  mm2 mirror plate...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.8.086005

    authors: Wang D,Fu L,Wang X,Gong Z,Samuelson S,Duan C,Jia H,Ma JS,Xie H

    更新日期:2013-08-01 00:00:00

  • Dynamic performance of microelectromechanical systems deformable mirrors for use in an active/adaptive two-photon microscope.

    abstract::Active optics such as deformable mirrors can be used to control both focal depth and aberrations during scanning laser microscopy. If the focal depth can be changed dynamically during scanning, then imaging of oblique surfaces becomes possible. If aberrations can be corrected dynamically during scanning, an image can ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.121507

    authors: Archer-Zhang CC,Foster WB,Downey RD,Arrasmith CL,Dickensheets DL

    更新日期:2016-12-01 00:00:00

  • Change of tumor vascular reactivity during tumor growth and postchemotherapy observed by near-infrared spectroscopy.

    abstract::Breast cancer is one of the most common cancers in females. To monitor chemotherapeutic efficacy for breast cancer, medical imaging systems such as x-ray mammography, computed tomography, magnetic resonance imaging, and ultrasound imaging have been used. Currently, it can take up to 3 to 6 weeks to see the tumor respo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.12.121603

    authors: Lee S,Jeong H,Seong M,Kim JG

    更新日期:2017-12-01 00:00:00

  • Single-cell analysis of dihydroartemisinin-induced apoptosis through reactive oxygen species-mediated caspase-8 activation and mitochondrial pathway in ASTC-a-1 cells using fluorescence imaging techniques.

    abstract::Dihydroartemisinin (DHA), a front-line antimalarial herbal compound, has been shown to possess promising anticancer activity with low toxicity. We have previously reported that DHA induced caspase-3-dependent apoptosis in human lung adenocarcinoma cells. However, the cellular target and molecular mechanism of DHA-indu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3481141

    authors: Lu YY,Chen TS,Wang XP,Li L

    更新日期:2010-07-01 00:00:00

  • Measurement of retinal blood flow in the rat by combining Doppler Fourier-domain optical coherence tomography with fundus imaging.

    abstract::A wide variety of ocular diseases are associated with abnormalities in ocular circulation. As such, there is considerable interest in techniques for quantifying retinal blood flow, among which Doppler optical coherence tomography (OCT) may be the most promising. We present an approach to measure retinal blood flow in ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106008

    authors: Werkmeister RM,Vietauer M,Knopf C,Fürnsinn C,Leitgeb RA,Reitsamer H,Gröschl M,Garhöfer G,Vilser W,Schmetterer L

    更新日期:2014-01-01 00:00:00

  • Two-photon imaging using adaptive phase compensated ultrashort laser pulses.

    abstract::An adaptive pulse shaper controlled by multiphoton intrapulse interference phase scanning (MIIPS) was used, together with a prism-pair, to measure and cancel high-order phase distortions introduced by a high-numerical-aperture objective and other dispersive elements of a two-photon laser-scanning microscope. The deliv...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3059629

    authors: Xi P,Andegeko Y,Pestov D,Lovozoy VV,Dantus M

    更新日期:2009-01-01 00:00:00