Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope.

Abstract:

:A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fiber bundle is combined with single mode fibers, for SMC and OCT imaging, respectively. The distal optics consist of a gradient-index lens and spacer to provide a 1× magnification at a working distance of 1.58 mm in air, necessary to image the sample through a 0.23-mm thick outer glass envelope, and an aluminized right-angle prism fixed to the distal end of the gradient-index lens assembly. The resulting 1∶1 imaging system is capable of 3.9-µm lateral and 2.3-µm axial resolution in the OCT channel, and 125-lp/mm resolution across a 0.70-mm field of view in the SMC channel. The endoscope can perform high contrast crypt visualization, molecular imaging, and cross-sectional imaging of colon microstructure.

journal_name

J Biomed Opt

authors

Wall RA,Barton JK

doi

10.1117/1.JBO.17.8.086003

subject

Has Abstract

pub_date

2012-08-01 00:00:00

pages

086003

issue

8

eissn

1083-3668

issn

1560-2281

pii

1352567

journal_volume

17

pub_type

杂志文章
  • Test-retest reliability of the prefrontal response to affective pictures based on functional near-infrared spectroscopy.

    abstract::Functional near-infrared spectroscopy (fNIRS) is being increasingly applied to affective and social neuroscience research; however, the reliability of this method is still unclear. This study aimed to evaluate the test–retest reliability of the fNIRS-based prefrontal response to emotional stimuli. Twenty-six participa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.1.016011

    authors: Huang Y,Mao M,Zhang Z,Zhou H,Zhao Y,Duan L,Kreplin U,Xiao X,Zhu C

    更新日期:2017-01-01 00:00:00

  • Light scattering of human red blood cells during metabolic remodeling of the membrane.

    abstract::We present the light scattering properties of individual human red blood cells (RBCs). We show that both the RBC static and dynamic scattering signals are altered by adenosine 5'-triphosphate (ATP)-driven membrane metabolic remodeling. To measure the light scattering signal from individual RBCs, we use diffraction pha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3524509

    authors: Park Y,Best-Popescu CA,Dasari RR,Popescu G

    更新日期:2011-01-01 00:00:00

  • Lamellar keratoplasty using position-guided surgical needle and M-mode optical coherence tomography.

    abstract::Deep anterior lamellar keratoplasty (DALK) is an emerging surgical technique for the restoration of corneal clarity and vision acuity. The big-bubble technique in DALK surgery is the most essential procedure that includes the air injection through a thin syringe needle to separate the dysfunctional region of the corne...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.12.125005

    authors: Shin S,Bae JK,Ahn Y,Kim H,Choi G,Yoo YS,Joo CK,Moon S,Jung W

    更新日期:2017-12-01 00:00:00

  • Three-beam spectral-domain optical coherence tomography for retinal imaging.

    abstract::A three-beam spectral domain optical coherence tomography system (OCT) whose center wavelength is 840 nm was developed. The three beams focus on fundus 3.1 mm apart from each other and are detected by a single line sensor. The distance between the beams is fixed and the beams scan a total area of 10×10  mm² while keep...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.106001

    authors: Suehira N,Ooto S,Hangai M,Matsumoto K,Tomatsu N,Yuasa T,Yamada K,Yoshimura N

    更新日期:2012-10-01 00:00:00

  • Two-photon microscopy of cortical NADH fluorescence intensity changes: correcting contamination from the hemodynamic response.

    abstract::Quantification of nicotinamide adenine dinucleotide (NADH) changes during functional brain activation and pathological conditions provides critical insight into brain metabolism. Of the different imaging modalities, two-photon laser scanning microscopy (TPLSM) is becoming an important tool for cellular-resolution meas...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3633339

    authors: Baraghis E,Devor A,Fang Q,Srinivasan VJ,Wu W,Lesage F,Ayata C,Kasischke KA,Boas DA,Sakadzić S

    更新日期:2011-10-01 00:00:00

  • Real-time measurement of the vaginal pressure profile using an optical-fiber-based instrumented speculum.

    abstract::Pelvic organ prolapse (POP) occurs when changes to the pelvic organ support structures cause descent or herniation of the pelvic organs into the vagina. Clinical evaluation of POP is a series of manual measurements known as the pelvic organ prolapse quantification (POP-Q) score. However, it fails to identify the mecha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.127008

    authors: Parkinson LA,Gargett CE,Young N,Rosamilia A,Vashi AV,Werkmeister JA,Papageorgiou AW,Arkwright JW

    更新日期:2016-12-01 00:00:00

  • Comparison of the sensitivity and image contrast in spontaneous Raman and coherent Stokes Raman scattering microscopy of geometry-controlled samples.

    abstract::We experimentally compare the performance and image contrast of spontaneous Raman and coherent Stokes Raman scattering microscopy. We demonstrate the differences between these techniques on a series of geometry-controlled samples that range in complexity from a point (array of tips) to one-dimensional (line grating) a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3533310

    authors: Kim H,Michaels CA,Bryant GW,Stranick SJ

    更新日期:2011-02-01 00:00:00

  • Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method.

    abstract::Fluorescence molecular tomography (FMT) is an important in vivo imaging modality to visualize physiological and pathological processes in small animals. However, FMT reconstruction is ill-posed and ill-conditioned due to strong optical scattering in deep tissues, which results in poor spatial resolution. It is well kn...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.055001

    authors: Baikejiang R,Zhao Y,Fite BZ,Ferrara KW,Li C

    更新日期:2017-05-01 00:00:00

  • Application of fluorescence recovery after photobleaching to study prestin lateral mobility in the human embryonic kidney cell.

    abstract::The transmembrane protein prestin is crucial to outer hair cell (OHC) electromotility and contributes to the sensitivity and frequency selectivity of mammalian hearing. The molecular mechanisms of electromotility remain unclear, but prestin is purported to function as both a voltage sensor and a molecular motor. Under...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2715202

    authors: Organ LE,Raphael RM

    更新日期:2007-03-01 00:00:00

  • Temperature-modulated fluorescence tomography based on both concentration and lifetime contrast.

    abstract::It is challenging to image fluorescence objects with high spatial resolution in a highly scattering medium. Recently reported temperature-sensitive indocyanine green-loaded pluronic nanocapsules can potentially alleviate this problem. Here we demonstrate a frequency-domain temperature-modulated fluorescence tomography...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.5.056007

    authors: Lin Y,Kwong TC,Bolisay L,Gulsen G

    更新日期:2012-05-01 00:00:00

  • System analysis of spatial frequency domain imaging for quantitative mapping of surgically resected breast tissues.

    abstract::The feasibility of spatial frequency domain imaging (SFDI) for breast surgical margin assessment was evaluated in tissue-simulating phantoms and in fully intact lumpectomy specimens at the time of surgery. Phantom data was evaluated according to contrast-detail resolution, quantitative accuracy and model-data goodness...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036012

    authors: Laughney AM,Krishnaswamy V,Rice TB,Cuccia DJ,Barth RJ,Tromberg BJ,Paulsen KD,Pogue BW,Wells WA

    更新日期:2013-03-01 00:00:00

  • Change of tumor vascular reactivity during tumor growth and postchemotherapy observed by near-infrared spectroscopy.

    abstract::Breast cancer is one of the most common cancers in females. To monitor chemotherapeutic efficacy for breast cancer, medical imaging systems such as x-ray mammography, computed tomography, magnetic resonance imaging, and ultrasound imaging have been used. Currently, it can take up to 3 to 6 weeks to see the tumor respo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.12.121603

    authors: Lee S,Jeong H,Seong M,Kim JG

    更新日期:2017-12-01 00:00:00

  • Design and characterization of a handheld multimodal imaging device for the assessment of oral epithelial lesions.

    abstract::A compact handpiece combining high resolution fluorescence (HRF) imaging with optical coherence tomography (OCT) was developed to provide real-time assessment of oral lesions. This multimodal imaging device simultaneously captures coregistered en face images with subcellular detail alongside cross-sectional images of ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.086004

    authors: Higgins LM,Pierce MC

    更新日期:2014-08-01 00:00:00

  • Detecting glucose-induced changes in in vitro and in vivo experiments with optical coherence tomography.

    abstract::Optical clearing is a well-known phenomenon. It is based on the matching of refractive indices of a bulk material and scattering particles. The same principle is also used in scattering-based optical measurements of different constituents, such as glucose. By registering changes in scattering, it is possible to evalua...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2904957

    authors: Kinnunen M,Myllylä R,Vainio S

    更新日期:2008-03-01 00:00:00

  • Evans blue dye-enhanced capillary-resolution photoacoustic microscopy in vivo.

    abstract::Complete and continuous imaging of microvascular networks is crucial for a wide variety of biomedical applications. Photoacoustic tomography can provide high resolution microvascular imaging using hemoglobin within red blood cells (RBCs) as an endogenic contrast agent. However, intermittent RBC flow in capillaries res...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3251044

    authors: Yao J,Maslov K,Hu S,Wang LV

    更新日期:2009-09-01 00:00:00

  • Diabetic retinopathy assessed by dynamic light scattering and corneal autofluorescence.

    abstract::Autofluorescence of the cornea within specific wavelength region and dynamic light scattering measurements of ocular tissue have both been used for early-stage detection of the presence of diabetic retinopathy. In the present study, autofluorescence of the cornea and dynamic light scattering in the cornea and vitreous...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429882

    authors: Rovati L,Fankhauser F,Docchio F,Van Best J

    更新日期:1998-07-01 00:00:00

  • Theory and practical recommendations for autocorrelation-based image correlation spectroscopy.

    abstract::Image correlation spectroscopy (ICS) is a powerful technique for detecting arrangement of fluorophores in images. This tutorial gives background into the mathematical underpinnings of ICS, specifically image autocorrelation. The effects of various artifacts and image processing steps, including background subtraction,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.080801

    authors: Robertson C,George SC

    更新日期:2012-08-01 00:00:00

  • New aspects in assessment of changes in width of subarachnoid space with near-infrared transillumination-backscattering sounding, part 2: clinical verification in the patient.

    abstract::The study presents comparison of near-infrared light propagation and near-infrared backscattered radiation power, as simulated with numerical modeling and measured live in a patient in clinical conditions with the use of the near-infrared transillumination-backscattering sounding (NIR-TBSS) technique. A unique chance ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2753756

    authors: Frydrychowski AF,Pluciński J

    更新日期:2007-07-01 00:00:00

  • Using thermographic cameras to investigate eye temperature and clinical severity in depression.

    abstract::Previous studies suggest that altered corneal temperature may be a feature of schizophrenia, but the association between major depressive disorder (MDD) and corneal temperature has yet to be assessed. The aim of this study is to investigate whether eye temperature is different among MDD patients than among healthy ind...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.026001

    authors: Maller JJ,George SS,Viswanathan RP,Fitzgerald PB,Junor P

    更新日期:2016-02-01 00:00:00

  • Rise of Raman spectroscopy in neurosurgery: a review.

    abstract:SIGNIFICANCE:Although the clinical potential for Raman spectroscopy (RS) has been anticipated for decades, it has only recently been used in neurosurgery. Still, few devices have succeeded in making their way into the operating room. With recent technological advancements, however, vibrational sensing is poised to be a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.5.050901

    authors: DePaoli D,Lemoine É,Ember K,Parent M,Prud'homme M,Cantin L,Petrecca K,Leblond F,Côté DC

    更新日期:2020-05-01 00:00:00

  • New method for evaluation of in vivo scattering and refractive index properties obtained with optical coherence tomography.

    abstract::Optical coherence tomography (OCT) provides more parameters than pure morphology does. In a recent paper [A. Knuettel and M. Boehlau-Godau, J. Biomed. Opt. 5(1) 83-92 (2000)] we have shown that the refractive index (RI) can be evaluated in a localized manner in skin tissue under in vivo conditions. Based on a theory, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1647544

    authors: Knüttel A,Bonev S,Knaak W

    更新日期:2004-03-01 00:00:00

  • Optical delivery of liposome encapsulated chemical stimuli to neuronal cells.

    abstract::Spatially confined and precise time delivery of neuroactive molecules is an important issue in neurophysiology. In this work we developed a technique for delivering chemical stimuli to cultured neurons consisting in encapsulating the molecules of interest in liposomes. These vectors were then loaded in reservoirs cons...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3616133

    authors: Pinato G,Raffaelli T,D'Este E,Tavano F,Cojoc D

    更新日期:2011-09-01 00:00:00

  • Overview of diffuse optical tomography and its clinical applications.

    abstract::Near-infrared diffuse optical tomography (DOT), one of the most sophisticated optical imaging techniques for observations through biological tissue, allows 3-D quantitative imaging of optical properties, which include functional and anatomical information. With DOT, it is expected to be possible to overcome the limita...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.21.9.091312

    authors: Hoshi Y,Yamada Y

    更新日期:2016-09-01 00:00:00

  • Mapping cisplatin-induced viscosity alterations in cancer cells using molecular rotor and fluorescence lifetime imaging microscopy.

    abstract:SIGNIFICANCE:Despite the importance of the cell membrane in regulation of drug activity, the influence of drug treatments on its physical properties is still poorly understood. The combination of fluorescence lifetime imaging microscopy (FLIM) with specific viscosity-sensitive fluorescent molecular rotors allows the qu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.12.126004

    authors: Shimolina LE,Gulin AA,Paez-Perez M,López-Duarte I,Druzhkova IN,Lukina MM,Gubina MV,Brooks NJ,Zagaynova EV,Kuimova MK,Shirmanova MV

    更新日期:2020-12-01 00:00:00

  • Spatially resolved optical and ultrastructural properties of colorectal and pancreatic field carcinogenesis observed by inverse spectroscopic optical coherence tomography.

    abstract::Field carcinogenesis is the initial stage of cancer progression. Understanding field carcinogenesis is valuable for both cancer biology and clinical medicine. Here, we used inverse spectroscopic optical coherence tomography to study colorectal cancer (CRC) and pancreatic cancer (PC) field carcinogenesis. Depth-resolve...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.3.036013

    authors: Yi J,Radosevich AJ,Stypula-Cyrus Y,Mutyal NN,Azarin SM,Horcher E,Goldberg MJ,Bianchi LK,Bajaj S,Roy HK,Backman V

    更新日期:2014-03-01 00:00:00

  • Raman biophysical markers in skin cancer diagnosis.

    abstract::Raman spectroscopy (RS) has demonstrated great potential for in vivo cancer screening; however, the biophysical changes that occur for specific diagnoses remain unclear. We recently developed an inverse biophysical skin cancer model to address this issue. Here, we presented the first demonstration of in vivo melanoma ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.057002

    authors: Feng X,Moy AJ,Nguyen HTM,Zhang Y,Zhang J,Fox MC,Sebastian KR,Reichenberg JS,Markey MK,Tunnell JW

    更新日期:2018-05-01 00:00:00

  • Technical considerations in longitudinal multispectral small animal molecular imaging.

    abstract::In a previous study, we investigated physical methods to reduce whole-body, diet-related autofluorescence interference in several mouse strains through changes in animal diet. Measurements of mice with an in vivo multispectral imaging system over a 21-day period allowed for the quantification of concentration changes ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2799188

    authors: Bouchard MB,MacLaurin SA,Dwyer PJ,Mansfield J,Levenson R,Krucker T

    更新日期:2007-09-01 00:00:00

  • Functional assessment of gap junctions in monolayer and three-dimensional cultures of human tendon cells using fluorescence recovery after photobleaching.

    abstract::Gap junction-mediated intercellular communication influences a variety of cellular activities. In tendons, gap junctions modulate collagen production, are involved in strain-induced cell death, and are involved in the response to mechanical stimulation. The aim of the present study was to investigate gap junction-medi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.015001

    authors: Kuzma-Kuzniarska M,Yapp C,Pearson-Jones TW,Jones AK,Hulley PA

    更新日期:2014-01-01 00:00:00

  • Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.

    abstract::This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.8.087001

    authors: Al-Fakih E,Arifin N,Pirouzi G,Mahamd Adikan FR,Shasmin HN,Abu Osman NA

    更新日期:2017-08-01 00:00:00

  • Comparison of motion correction techniques applied to functional near-infrared spectroscopy data from children.

    abstract::Motion artifacts are the most significant sources of noise in the context of pediatric brain imaging designs and data analyses, especially in applications of functional near-infrared spectroscopy (fNIRS), in which it can completely affect the quality of the data acquired. Different methods have been developed to corre...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.126003

    authors: Hu XS,Arredondo MM,Gomba M,Confer N,DaSilva AF,Johnson TD,Shalinsky M,Kovelman I

    更新日期:2015-01-01 00:00:00