New aspects in assessment of changes in width of subarachnoid space with near-infrared transillumination-backscattering sounding, part 2: clinical verification in the patient.

Abstract:

:The study presents comparison of near-infrared light propagation and near-infrared backscattered radiation power, as simulated with numerical modeling and measured live in a patient in clinical conditions with the use of the near-infrared transillumination-backscattering sounding (NIR-TBSS) technique. A unique chance for such precise comparative analysis was available to us in a clinical case of a female patient with scalp removed from one half of the head due to injury. The analysis performed indicates that the difference between the intensity of the signals in numerical modeling and live measurements is less than 4 dB. Analysis of the theoretical model also provides hints on the positioning of the two detectors relative to the source of radiation. Correctness of these predicted values is confirmed in practical application, when changes of signals received by the detectors are recorded, along with changes of the width of the subarachnoid space. What is more, the power distribution of the spectrum of near-infrared backscattered radiation returning to the detectors is confirmed in the real recording in the patient. An abridged description of the new method of NIR-TBSS is presented.

journal_name

J Biomed Opt

authors

Frydrychowski AF,Pluciński J

doi

10.1117/1.2753756

subject

Has Abstract

pub_date

2007-07-01 00:00:00

pages

044016

issue

4

eissn

1083-3668

issn

1560-2281

journal_volume

12

pub_type

杂志文章
  • Optical reflectance assay for the detection of biofilm formation.

    abstract::We describe the protocol for an inexpensive and nondestructive optical reflectance assay for the measurement of biofilm formation. Reflectance data are obtained using an Ocean Optics (Dunedin, Florida) USB 2000 spectrometer with a polychromatic light source. A fiber optic cable is used both for illumination and collec...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1953347

    authors: Broschat SL,Loge FJ,Peppin JD,White D,Call DR,Kuhn E

    更新日期:2005-07-01 00:00:00

  • Micro-Raman spectroscopy study of cancerous and normal nasopharyngeal tissues.

    abstract::The capabilities of micro-Raman spectroscopy for differentiating normal and malignant nasopharyngeal tissues were evaluated. Raman scattering signals were acquired from 22 normal and 52 malignant nasopharyngeal tissue samples. Distinctive spectral differences in Raman spectra between normal and malignant nasopharyngea...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.2.027003

    authors: Li Y,Pan J,Chen G,Li C,Lin S,Shao Y,Feng S,Huang Z,Xie S,Zeng H,Chen R

    更新日期:2013-02-01 00:00:00

  • Pulse-modulated second harmonic imaging microscope quantitatively demonstrates marked increase of collagen in tumor after chemotherapy.

    abstract::Pulse-modulated second harmonic imaging microscopes (PM-SHIMs) exhibit improved signal-to-noise ratio (SNR) over conventional SHIMs on sensitive imaging and quantification of weak collagen signals inside tissues. We quantify the spatial distribution of sparse collagen inside a xenograft model of human acute myeloid le...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3497565

    authors: Raja AM,Xu S,Sun W,Zhou J,Tai DC,Chen CS,Rajapakse JC,So PT,Yu H

    更新日期:2010-09-01 00:00:00

  • Mathematical model that describes the transition from thermal to photochemical damage in retinal pigment epithelial cell culture.

    abstract::We propose a rate process model for describing photochemical damage to retinal cells by short wavelength laser exposures. The rate equation for photochemical damage contains a positive rate that is temperature independent, and a negative (quenching) rate that is temperature dependent. Using the traditional Arrhenius i...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3544504

    authors: Clark CD 3rd,Denton ML,Thomas RJ

    更新日期:2011-02-01 00:00:00

  • Raman biophysical markers in skin cancer diagnosis.

    abstract::Raman spectroscopy (RS) has demonstrated great potential for in vivo cancer screening; however, the biophysical changes that occur for specific diagnoses remain unclear. We recently developed an inverse biophysical skin cancer model to address this issue. Here, we presented the first demonstration of in vivo melanoma ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.057002

    authors: Feng X,Moy AJ,Nguyen HTM,Zhang Y,Zhang J,Fox MC,Sebastian KR,Reichenberg JS,Markey MK,Tunnell JW

    更新日期:2018-05-01 00:00:00

  • Photoacoustic tomography of ex vivo mouse hearts with myocardial infarction.

    abstract::In the present study, we evaluated the applicability of ex vivo photoacoustic imaging (PAI) on small animal organs. We used photoacoustic tomography (PAT) to visualize infarcted areas within murine hearts and compared these data to other imaging techniques [magnetic resonance imaging (MRI), micro-computed tomography] ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3556720

    authors: Holotta M,Grossauer H,Kremser C,Torbica P,Völkl J,Degenhart G,Esterhammer R,Nuster R,Paltauf G,Jaschke W

    更新日期:2011-03-01 00:00:00

  • Water wavenumber calibration for visible light optical coherence tomography.

    abstract:SIGNIFICANCE:Visible light optical coherence tomography (OCT) is emerging for spectroscopic and ultrahigh resolution imaging, but challenges remain. Depth-dependent dispersion limits retinal image quality and current correction approaches are cumbersome. Inconsistent group refractive indices during image reconstruction...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.9.090501

    authors: Zhang T,Kho AM,Srinivasan VJ

    更新日期:2020-09-01 00:00:00

  • Fast spatiotemporal image reconstruction based on low-rank matrix estimation for dynamic photoacoustic computed tomography.

    abstract::In order to monitor dynamic physiological events in near-real time, a variety of photoacoustic computed tomography (PACT) systems have been developed that can rapidly acquire data. Previously reported studies of dynamic PACT have employed conventional static methods to reconstruct a temporally ordered sequence of imag...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.056007

    authors: Wang K,Xia J,Li C,Wang LV,Anastasio MA

    更新日期:2014-05-01 00:00:00

  • Evaluating the use of optical coherence tomography for the detection of epithelial cancers in vitro.

    abstract::Optical coherence tomography (OCT) is a noninvasive imaging methodology that is able to image tissue to depths of over 1 mm. Many epithelial conditions, such as melanoma and oral cancers, require an invasive biopsy for diagnosis. A noninvasive, real-time, point of care method of imaging depth-resolved epithelial struc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3652708

    authors: Smith LE,Hearnden V,Lu Z,Smallwood R,Hunter KD,Matcher SJ,Thornhill MH,Murdoch C,MacNeil S

    更新日期:2011-11-01 00:00:00

  • Simultaneous measurement of dispersion, spectrum, and distance with a fourier transform spectrometer.

    abstract::A Fourier transform spectrometer is used to simultaneously measure distance, dispersion and spectrum. It is shown that short coherence interferometry has the potential to measure the three-dimensional distribution of the spatial structure of a sample with a resolution determined by the coherence length of the light so...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429885

    authors: Hellmuth T,Welle M

    更新日期:1998-01-01 00:00:00

  • Optical fiber-based dispersion for spectral discrimination in fluorescence lifetime imaging systems.

    abstract::The excited state lifetime of a fluorophore together with its fluorescence emission spectrum provide information that can yield valuable insights into the nature of a fluorophore and its microenvironment. However, it is difficult to obtain both channels of information in a conventional scheme as detectors are typicall...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.1.014506

    authors: Sagar MAK,Dai B,Chacko J,Weber J,Velten A,Sanders S,White J,Eliceiri K

    更新日期:2019-12-01 00:00:00

  • Diagnostic performance of receptor-specific surgical specimen staining correlates with receptor expression level.

    abstract::Intraoperative margin assessment is imperative to cancer cure but is a continued challenge to successful surgery. Breast conserving surgery is a relevant example, where a cosmetically improved outcome is gained over mastectomy, but re-excision is required in >25  %   of cases due to positive or closely involved margin...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.026002

    authors: Schaefer JM,Barth CW,Davis SC,Gibbs SL

    更新日期:2019-02-01 00:00:00

  • Continuous monitoring of arthritis in animal models using optical imaging modalities.

    abstract::Given the several difficulties associated with histology, including difficulty in continuous monitoring, this study aimed to investigate the feasibility of optical imaging modalities—cross-polarization color (CPC) imaging, erythema index (EI) imaging, and laser speckle contrast (LSC) imaging—for continuous evaluation ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106010

    authors: Son T,Yoon HJ,Lee S,Jang WS,Jung B,Kim WU

    更新日期:2014-01-01 00:00:00

  • Adaptive wide-field optical tomography.

    abstract::We describe a wide-field optical tomography technique, which allows the measurement-guided optimization of illumination patterns for enhanced reconstruction performances. The iterative optimization of the excitation pattern aims at reducing the dynamic range in photons transmitted through biological tissue. It increas...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036006

    authors: Venugopal V,Intes X

    更新日期:2013-03-01 00:00:00

  • Quantitative real-time optical imaging of the tissue metabolic rate of oxygen consumption.

    abstract::The tissue metabolic rate of oxygen consumption (tMRO2) is a clinically relevant marker for a number of pathologies including cancer and arterial occlusive disease. We present and validate a noncontact method for quantitatively mapping tMRO2 over a wide, scalable field of view at 16  frames  /  s. We achieve this by d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.3.036013

    authors: Ghijsen M,Lentsch GR,Gioux S,Brenner M,Durkin AJ,Choi B,Tromberg BJ

    更新日期:2018-03-01 00:00:00

  • Eigenvector-based spatial filtering for reduction of physiological interference in diffuse optical imaging.

    abstract::Diffuse optical imaging is an effective technique for noninvasive functional brain imaging. However, the measurements respond to systemic hemodynamic fluctuations caused by the cardiac cycle, respiration, and blood pressure, which may obscure or overwhelm the desired stimulus-evoked response. Previous work on this pro...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1852552

    authors: Zhang Y,Brooks DH,Franceschini MA,Boas DA

    更新日期:2005-01-01 00:00:00

  • FLIM data analysis based on Laguerre polynomial decomposition and machine-learning.

    abstract:SIGNIFICANCE:The potential of fluorescence lifetime imaging microscopy (FLIM) is recently being recognized, especially in biological studies. However, FLIM does not directly measure the lifetimes, rather it records the fluorescence decay traces. The lifetimes and/or abundances have to be estimated from these traces dur...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.26.2.022909

    authors: Guo S,Silge A,Bae H,Tolstik T,Meyer T,Matziolis G,Schmitt M,Popp J,Bocklitz T

    更新日期:2021-01-01 00:00:00

  • Study of the inhibition effect of thiazone on muscle optical clearing.

    abstract::We investigated the effect of thiazone, a widely used penetration enhancer, on in vitro porcine skin and muscle tissue by single-integrating sphere technique during optical clearing (OC) treatment. The results showed that thiazone induced an increase on the total transmittance of skin which led to a reduction in that ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.105004

    authors: Jin X,Deng Z,Wang J,Ye Q,Mei J,Zhou W,Zhang C,Tian J

    更新日期:2016-10-01 00:00:00

  • Using ultrahigh sensitive optical microangiography to achieve comprehensive depth resolved microvasculature mapping for human retina.

    abstract::This paper presents comprehensive and depth-resolved retinal microvasculature images within human retina achieved by a newly developed ultrahigh sensitive optical microangiography (UHS-OMAG) system. Due to its high flow sensitivity, UHS-OMAG is much more sensitive to tissue motion due to the involuntary movement of th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3642638

    authors: An L,Shen TT,Wang RK

    更新日期:2011-10-01 00:00:00

  • Raman microscopy in the diagnosis and prognosis of surgically resected nonsmall cell lung cancer.

    abstract::The main curative therapy for patients with nonsmall cell lung cancer is surgery. Despite this, the survival rate is only 50%, therefore it is important to more efficiently diagnose and predict prognosis for lung cancer patients. Raman spectroscopy is useful in the diagnosis of malignant and premalignant lesions. The ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3323088

    authors: Magee ND,Beattie JR,Carland C,Davis R,McManus K,Bradbury I,Fennell DA,Hamilton PW,Ennis M,McGarvey JJ,Elborn JS

    更新日期:2010-03-01 00:00:00

  • Low-level chemiluminescent analysis of nondiluted human blood reveals its dynamic system properties.

    abstract::Lucigenin- and luminol-dependent chemiluminescence [(LC-CL) and (LM-CL)] in nondiluted human blood was studied. LM-CL was low in fresh blood and disappeared after its storage for 3 h, though the respiratory burst (RB) stimulation in blood was followed by high intensity and long-lasting LM-CL. LC-CL was high in fresh b...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429921

    authors: Voeikov VL,Novikov CN,Vilenskaya ND

    更新日期:1999-01-01 00:00:00

  • Optical pH measurement system using a single fluorescent dye for assessing susceptibility to dental caries.

    abstract::Sugar-rich diets and poor dental hygiene promote the formation of a biofilm (plaque) that strongly adheres to the dental enamel surface and fosters the evolution of aciduric bacteria. The acid contributes to demineralization of the exterior tooth enamel, which accelerates after the pH drops below a critical value (∼5....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.1.017001

    authors: Sharma M,Graham JY,Walczak PA,Nguyen R,Lee LK,Carson MD,Nelson LY,Patel SN,Xu Z,Seibel EJ

    更新日期:2019-01-01 00:00:00

  • Video-rate optical flow corrected intraoperative functional fluorescence imaging.

    abstract::Intraoperative fluorescence molecular imaging based on targeted fluorescence agents is an emerging approach to improve surgical and endoscopic imaging and guidance. Short exposure times per frame and implementation at video rates are necessary to provide continuous feedback to the physician and avoid motion artifacts....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046012

    authors: Koch M,Glatz J,Ermolayev V,de Vries EG,van Dam GM,Englmeier KH,Ntziachristos V

    更新日期:2014-04-01 00:00:00

  • Holographic analysis on deformation and restoration of malaria-infected red blood cells by antimalarial drug.

    abstract::Malaria parasites induce morphological, biochemical, and mechanical changes in red blood cells (RBCs). Mechanical variations are closely related to the deformability of individual RBCs. The deformation of various RBCs, including healthy and malaria-infected RBCs (iRBCs), can be directly observed through quantitative p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.11.115003

    authors: Byeon H,Ha YR,Lee SJ

    更新日期:2015-11-01 00:00:00

  • Computational segmentation of collagen fibers from second-harmonic generation images of breast cancer.

    abstract::Second-harmonic generation (SHG) imaging can help reveal interactions between collagen fibers and cancer cells. Quantitative analysis of SHG images of collagen fibers is challenged by the heterogeneity of collagen structures and low signal-to-noise ratio often found while imaging collagen in tissue. The role of collag...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.016007

    authors: Bredfeldt JS,Liu Y,Pehlke CA,Conklin MW,Szulczewski JM,Inman DR,Keely PJ,Nowak RD,Mackie TR,Eliceiri KW

    更新日期:2014-01-01 00:00:00

  • Real-time in vivo photoacoustic and ultrasound imaging.

    abstract::A real-time photoacoustic imaging system is designed and built. This system is based on a commercially available ultrasound imaging system. It can achieve a frame rate of 8 frames/sec. Vasculature in the hand of a human volunteer is imaged, and the resulting photoacoustic image is combined with the ultrasound image. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3005421

    authors: Kolkman RG,Brands PJ,Steenbergen W,van Leeuwen TG

    更新日期:2008-09-01 00:00:00

  • Blind deconvolution estimation of fluorescence measurements through quadratic programming.

    abstract::Time-deconvolution of the instrument response from fluorescence lifetime imaging microscopy (FLIM) data is usually necessary for accurate fluorescence lifetime estimation. In many applications, however, the instrument response is not available. In such cases, a blind deconvolution approach is required. An iterative me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075010

    authors: Campos-Delgado DU,Gutierrez-Navarro O,Arce-Santana ER,Skala MC,Walsh AJ,Jo JA

    更新日期:2015-07-01 00:00:00

  • High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second.

    abstract::We propose a useful method to boost the imaging speed for spectral domain optical coherence tomography (SDOCT) by multiplying a number of high-speed spectrometers used in the system with selective precise control of data-recording and data-reading phases for spectral cameras employed in each spectrometer. To demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3592492

    authors: An L,Guan G,Wang RK

    更新日期:2011-06-01 00:00:00

  • Laser-ultraviolet-A-induced ultraweak photon emission in mammalian cells.

    abstract::Photobiological research in the last 30 yr has shown the existence of ultraweak photon emission in biological tissue, which can be detected with sophisticated photomultiplier systems. Although the emission of this ultraweak radiation, often termed biophotons, is extremely low in mammalian cells, it can be efficiently ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1899185

    authors: Niggli HJ,Tudisco S,Privitera G,Applegate LA,Scordino A,Musumeci F

    更新日期:2005-03-01 00:00:00

  • Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope.

    abstract::A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fib...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.086003

    authors: Wall RA,Barton JK

    更新日期:2012-08-01 00:00:00