Optical detection of intracellular cavitation during selective laser targeting of the retinal pigment epithelium: dependence of cell death mechanism on pulse duration.

Abstract:

:Selective laser targeting of the retinal pigment epithelium (RPE) is an attractive method for treating RPE-associated disorders. We are developing a method for optically detecting intracellular microcavitation that can potentially serve as an immediate feedback of the treatment outcome. Thermal denaturation or intracellular cavitation can kill RPE cells during selective targeting. We examined the cell damage mechanism for laser pulse durations from 1 to 40 micros ex vivo. Intracellular cavitation was detected as a transient increase in the backscattered treatment beam. Cavitation and cell death were correlated for individual cells after single-pulse irradiation. The threshold radiant exposures for cell death (ED(50,d)) and cavitation (ED(50,c)) increased with pulse duration and were approximately equal for pulses of up to 10 micros. For 20 micros, the ED(50,d) was about 10% lower than the ED(50,c); the difference increased with 40-micros pulses. Cells were killed predominantly by cavitation (up to 10-micros pulses); probability of thermally induced cell death without cavitation gradually increases with pulse duration. Threshold measurements are discussed by modeling the temperature distribution around laser-heated melanosomes and the scattering function from the resulting cavitation. Detection of intracellular cavitation is a highly sensitive method that can potentially provide real-time assessment of RPE damage during selective laser targeting.

journal_name

J Biomed Opt

authors

Lee H,Alt C,Pitsillides CM,Lin CP

doi

10.1117/1.2804078

subject

Has Abstract

pub_date

2007-11-01 00:00:00

pages

064034

issue

6

eissn

1083-3668

issn

1560-2281

journal_volume

12

pub_type

杂志文章
  • Detection of canine skin and subcutaneous tumors by visible and near-infrared diffuse reflectance spectroscopy.

    abstract::Cancer is the main cause of canine morbidity and mortality. The existing evaluation of tumors requires an experienced veterinarian and usually includes invasive procedures (e.g., fine-needle aspiration) that can be unpleasant for the dog and the owner. We investigate visible and near-infrared diffuse reflectance spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.3.037003

    authors: Cugmas B,Plavec T,Bregar M,Naglič P,Pernuš F,Likar B,Bürmen M

    更新日期:2015-03-01 00:00:00

  • Noncontact photoacoustic tomography of in vivo chicken chorioallantoic membrane based on all-fiber heterodyne interferometry.

    abstract::We present three-dimensional (3-D) in vivo photoacoustic (PA) images of the blood vasculature of a chicken chorioallantoic membrane (CAM) obtained by using a fiber-based noncontact PA tomography system. With a fiber-optic heterodyne interferometer, the system measures the surface displacement of a sample, induced by t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106007

    authors: Eom J,Park SJ,Lee BH

    更新日期:2015-10-01 00:00:00

  • Quantitative diffuse reflectance and fluorescence spectroscopy: tool to monitor tumor physiology in vivo.

    abstract::This study demonstrates the use of optical spectroscopy for monitoring tumor oxygenation and metabolism in response to hyperoxic gas breathing. Hemoglobin saturation and redox ratio were quantified for a set of 14 and 9 mice, respectively, measured at baseline and during carbogen breathing (95% O(2), 5% CO(2)). In par...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3103586

    authors: Palmer GM,Viola RJ,Schroeder T,Yarmolenko PS,Dewhirst MW,Ramanujam N

    更新日期:2009-03-01 00:00:00

  • Quantitative three-dimensional photoacoustic tomography of the finger joints: an in vivo study.

    abstract::We present for the first time in vivo full three-dimensional (3-D) photoacoustic tomography (PAT) of the distal interphalangeal joint in a human subject. Both absorbed energy density and absorption coefficient images of the joint are quantitatively obtained using our finite-element-based photoacoustic image reconstruc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3257246

    authors: Sun Y,Sobel E,Jiang H

    更新日期:2009-11-01 00:00:00

  • Analyzing reflectance spectra of human skin in legal medicine.

    abstract::Our current research in the framework of an interdisciplinary project focuses on modelling the dynamics of the hemoglobin reoxygenation process in post-mortem human skin by reflectance spectrometry. The observations of reoxygenation of hemoglobin in livores after postmortem exposure to a cold environment relate the re...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.017004

    authors: Belenki L,Sterzik V,Schulz K,Bohnert M

    更新日期:2013-01-01 00:00:00

  • On the noninvasive optical monitoring and differentiation of methemoglobinemia and sulfhemoglobinemia.

    abstract::There are several pathologies whose study and diagnosis is impaired by a relatively small number of documented cases. A practical approach to overcome this obstacle and advance the research in this area consists in employing computer simulations to perform controlled in silico experiments. The results of these experim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.9.097005

    authors: Baranoski GV,Chen TF,Kimmel BW,Miranda E,Yim D

    更新日期:2012-09-01 00:00:00

  • Parameters affecting ultrafast laser microsurgery of subepithelial voids for scar treatment in vocal folds.

    abstract::Toward developing a new method for restoring tissue viscoelasticity in scarred vocal folds, we previously proposed a method to localize biomaterials within subepithelial voids ablated using ultrafast laser pulses. The clinical implementation of this method necessitates the quantification of the laser parameters for ab...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.11.118001

    authors: Yildirim M,Ferhanoglu O,Kobler J,Zeitels SM,Ben-Yakar A

    更新日期:2013-11-01 00:00:00

  • Real-time brightfield, darkfield, and phase contrast imaging in a light-emitting diode array microscope.

    abstract::We demonstrate a single-camera imaging system that can simultaneously acquire brightfield, darkfield, and phase contrast images in real time. Our method uses computational illumination via a programmable light-emitting diode (LED) array at the source plane, providing flexible patterning of illumination angles. Brightf...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106002

    authors: Liu Z,Tian L,Liu S,Waller L

    更新日期:2014-01-01 00:00:00

  • Coregistered photoacoustic and ultrasound imaging and classification of ovarian cancer: ex vivo and in vivo studies.

    abstract::Most ovarian cancers are diagnosed at advanced stages due to the lack of efficacious screening techniques. Photoacoustic tomography (PAT) has a potential to image tumor angiogenesis and detect early neovascular changes of the ovary. We have developed a coregistered PAT and ultrasound (US) prototype system for real-tim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.4.046006

    authors: Salehi HS,Li H,Merkulov A,Kumavor PD,Vavadi H,Sanders M,Kueck A,Brewer MA,Zhu Q

    更新日期:2016-04-30 00:00:00

  • Variations in the endogenous fluorescence of rabbit corneas after mechanical property alterations.

    abstract::Keratoconus is an eye disease in which the cornea progressively deforms due to loss of cornea mechanical rigidity, and thus causes deterioration of visual acuity. Techniques to characterize the mechanical characteristics of the cornea are important to better monitor changes and response to treatments. To investigate t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.095005

    authors: Ortega-Martinez A,Touchette G,Zhu H,Kochevar IE,Franco W

    更新日期:2017-09-01 00:00:00

  • Diagnosis of oral submucous fibrosis with optical coherence tomography.

    abstract::The epithelium (EP) thickness and the standard deviation (SD) of A-mode scan intensity in the laminar propria (LP) layer are used as effective indicators for the diagnosis of oral submucous fibrosis (OSF) based on the noninvasive clinical scanning of a swept-source optical coherence tomography (OCT) system of approxim...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3233653

    authors: Lee CK,Tsai MT,Lee HC,Chen HM,Chiang CP,Wang YM,Yang CC

    更新日期:2009-09-01 00:00:00

  • Experimental measurement of time-dependent photon scatter for diffuse optical tomography.

    abstract::Time-resolved measurement of early arriving photons through diffusive media has been shown to effectively reduce the high degree of light scatter in biological tissue. However, the experimentally achievable reduction in photon scatter and the impact of time-gated detection on instrument noise performance is not well u...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3523371

    authors: Valim N,Brock J,Niedre M

    更新日期:2010-11-01 00:00:00

  • Design and characterization of a handheld multimodal imaging device for the assessment of oral epithelial lesions.

    abstract::A compact handpiece combining high resolution fluorescence (HRF) imaging with optical coherence tomography (OCT) was developed to provide real-time assessment of oral lesions. This multimodal imaging device simultaneously captures coregistered en face images with subcellular detail alongside cross-sectional images of ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.086004

    authors: Higgins LM,Pierce MC

    更新日期:2014-08-01 00:00:00

  • Optimal optode montage on electroencephalography/functional near-infrared spectroscopy caps dedicated to study epileptic discharges.

    abstract::Functional near-infrared spectroscopy (fNIRS), acquired simultaneously with electroencephalography (EEG), allows the investigation of hemodynamic brain responses to epileptic activity. Because the presumed epileptogenic focus is patient-specific, an appropriate source/detector (SD) montage has to be reconfigured for e...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.2.026010

    authors: Machado A,Marcotte O,Lina JM,Kobayashi E,Grova C

    更新日期:2014-02-01 00:00:00

  • Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics.

    abstract::Application of a fiber optic biosensor (FOB) to the real-time investigation of the interaction kinetics between FITC-conjugated monoclonal sheep anti-human C-reactive protein (CRP) antibody and CRP isoforms on the surface of optical fiber is described. Recently, both the native pentameric CRP (pCRP), an acute phase pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714029

    authors: Chou C,Hsu HY,Wu HT,Tseng KY,Chiou A,Yu CJ,Lee ZY,Chan TS

    更新日期:2007-03-01 00:00:00

  • Multi-reference global registration of individual A-lines in adaptive optics optical coherence tomography retinal images.

    abstract:SIGNIFICANCE:Adaptive optics optical coherence tomography (AO-OCT) technology enables non-invasive, high-resolution three-dimensional (3D) imaging of the retina and promises earlier detection of ocular disease. However, AO-OCT data are corrupted by eye-movement artifacts that must be removed in post-processing, a proce...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.26.1.016001

    authors: Kurokawa K,Crowell JA,Do N,Lee JJ,Miller DT

    更新日期:2021-01-01 00:00:00

  • Light scattering of human red blood cells during metabolic remodeling of the membrane.

    abstract::We present the light scattering properties of individual human red blood cells (RBCs). We show that both the RBC static and dynamic scattering signals are altered by adenosine 5'-triphosphate (ATP)-driven membrane metabolic remodeling. To measure the light scattering signal from individual RBCs, we use diffraction pha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3524509

    authors: Park Y,Best-Popescu CA,Dasari RR,Popescu G

    更新日期:2011-01-01 00:00:00

  • Endoscopic swept-source optical coherence tomography based on a two-axis microelectromechanical system mirror.

    abstract::A microelectromechanical system (MEMS) mirror based endoscopic swept-source optical coherence tomography (SS-OCT) system that can perform three-dimensional (3-D) imaging at high speed is reported. The key component enabling 3-D endoscopic imaging is a two-axis MEMS scanning mirror which has a 0.8×0.8  mm2 mirror plate...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.8.086005

    authors: Wang D,Fu L,Wang X,Gong Z,Samuelson S,Duan C,Jia H,Ma JS,Xie H

    更新日期:2013-08-01 00:00:00

  • Confocal fluorescence microscope with dual-axis architecture and biaxial postobjective scanning.

    abstract::We present a novel confocal microscope that has dual-axis architecture and biaxial postobjective scanning for the collection of fluorescence images from biological specimens. This design uses two low-numerical-aperture lenses to achieve high axial resolution and long working distance, and the scanning mirror located d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1760760

    authors: Wang TD,Contag CH,Mandella MJ,Chan NY,Kino GS

    更新日期:2004-07-01 00:00:00

  • Visible-wavelength two-photon excitation microscopy with multifocus scanning for volumetric live-cell imaging.

    abstract::Two-photon excitation microscopy is one of the key techniques used to observe three-dimensional (3-D) structures in biological samples. We utilized a visible-wavelength laser beam for two-photon excitation in a multifocus confocal scanning system to improve the spatial resolution and image contrast in 3-D live-cell im...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.1.014502

    authors: Oketani R,Suda H,Uegaki K,Kubo T,Matsuda T,Yamanaka M,Arai Y,Smith N,Nagai T,Fujita K

    更新日期:2019-11-01 00:00:00

  • Time-dependent blood flow and oxygenation in human skeletal muscles measured with noninvasive near-infrared diffuse optical spectroscopies.

    abstract::We have employed near-infrared optical methods to measure noninvasively the dynamics of muscle blood flow and oxygen saturation (StO2) during cuff occlusion and plantar flexion exercise. Relative muscle oxygen consumption (rVO2) was also computed from these data. Diffuse correlation spectroscopy provides information a...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1884603

    authors: Yu G,Durduran T,Lech G,Zhou C,Chance B,Mohler ER 3rd,Yodh AG

    更新日期:2005-03-01 00:00:00

  • Near-infrared light-responsive liposomal contrast agent for photoacoustic imaging and drug release applications.

    abstract::Photoacoustic imaging has become an emerging tool for theranostic applications. Not only does it help in

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.4.041007

    authors: Sivasubramanian K,Mathiyazhakan M,Wiraja C,Upputuri PK,Xu C,Pramanik M

    更新日期:2017-04-01 00:00:00

  • High-speed 1310 nm-band spectral domain optical coherence tomography at 184,000 lines per second.

    abstract::We propose a useful method to boost the imaging speed for spectral domain optical coherence tomography (SDOCT) by multiplying a number of high-speed spectrometers used in the system with selective precise control of data-recording and data-reading phases for spectral cameras employed in each spectrometer. To demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3592492

    authors: An L,Guan G,Wang RK

    更新日期:2011-06-01 00:00:00

  • Optical properties of mouse brain tissue after optical clearing with FocusClear™.

    abstract::Fluorescence microscopy is commonly used to investigate disease progression in biological tissues. Biological tissues, however, are strongly scattering in the visible wavelengths, limiting the application of fluorescence microscopy to superficial (<200µm) regions. Optical clearing, which involves incubation of the tis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.9.095010

    authors: Moy AJ,Capulong BV,Saager RB,Wiersma MP,Lo PC,Durkin AJ,Choi B

    更新日期:2015-01-01 00:00:00

  • Label-free imaging of biomolecules in food products using stimulated Raman microscopy.

    abstract::The development of methods that allow microscale studies of complex biomaterials based on their molecular composition is of great interest to a wide range of research fields. We show that stimulated Raman scattering (SRS) microscopy is an excellent analytical tool to study distributions of different biomolecules in mu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3516591

    authors: Roeffaers MB,Zhang X,Freudiger CW,Saar BG,van Ruijven M,van Dalen G,Xiao C,Xie XS

    更新日期:2010-11-01 00:00:00

  • Confocal detection of planar homogeneous and heterogeneous immunosorbent assays.

    abstract::Optically sectioned detection of fluorescence immunoassays using a confocal microscope enables the creation of both homo- and heterogeneous planar format assays. We report a set assays requiring optically sectioned detection using a model system and analysis procedures for separating signals of a surface layer from an...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3268772

    authors: Ghafari H,Zhou Y,Ali S,Hanley QS

    更新日期:2009-11-01 00:00:00

  • Real-time full-field photoacoustic imaging using an ultrasonic camera.

    abstract::A photoacoustic imaging system that incorporates a commercial ultrasonic camera for real-time imaging of two-dimensional (2-D) projection planes in tissue at video rate (30 Hz) is presented. The system uses a Q-switched frequency-doubled Nd:YAG pulsed laser for photoacoustic generation. The ultrasonic camera consists ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3420079

    authors: Balogun O,Regez B,Zhang HF,Krishnaswamy S

    更新日期:2010-03-01 00:00:00

  • Acousto-optic-tunable-filter-based spectropolarimetric imagers for medical diagnostic applications--instrument design point of view.

    abstract::Compact optical imagers that can detect both spectral and polarization signatures are required in many biomedical applications. An acousto-optic-tunable-filter (AOTF)-based imager is ideally suited to provide both agile spectral and polarization signatures. Such an imager can be readily used for real-time in vivo medi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2102507

    authors: Gupta N

    更新日期:2005-09-01 00:00:00

  • Study on application of optical clearing technique in skin diseases.

    abstract::So far, the study of the optical clearing is almost always about healthy tissue. However, the ultimate goal is to detect diseases for clinical application. Optical clearing on diseased skins is explored. The effect is evaluated by applying a combined liquid paraffin and glycerol mixed solution on several kinds of dise...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.115003

    authors: Shan H,Liang Y,Wang J,Li Y

    更新日期:2012-11-01 00:00:00

  • Time-resolved diffuse optical tomography and its application to in vitro and in vivo imaging.

    abstract::This work reviews our research during the past several years on time-resolved (TR) near-infrared diffuse optical tomography (DOT). Following an introduction of the measuring modes, two proposed schemes of image reconstruction in TR-DOT are described: one utilizes the full TR data, and the other, referred to as the mod...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2815724

    authors: Zhao H,Gao F,Tanikawa Y,Yamada Y

    更新日期:2007-11-01 00:00:00