Rapid convergence to the inverse solution regularized with Lorentzian distributed function for near-infrared continuous wave diffuse optical tomography.

Abstract:

:A promising method to achieve rapid convergence for image reconstruction is introduced for the continuous-wave near-infrared (NIR) diffuse optical tomography (DOT). Tomographic techniques are usually implemented off line and are time consuming to realize image reconstruction, especially for NIR DOT. Therefore, it is essential to both speed up reconstruction and achieve stable and convergent solutions. We propose an approach using a constraint based on a Lorentzian distributed function incorporated into Tikhonov regularization, thereby rapidly converging a stable solution. It is found in the study that using the proposed method with around five or six iterations leads to a stable solution. The result is compared to the primary method usually converging in approximately 25 iterations. Our algorithm rapidly converges to stable solution in the case of noisy (>20 dB) detected intensities.

journal_name

J Biomed Opt

authors

Pan MC,Pan MC

doi

10.1117/1.3299727

subject

Has Abstract

pub_date

2010-01-01 00:00:00

pages

016014

issue

1

eissn

1083-3668

issn

1560-2281

journal_volume

15

pub_type

杂志文章
  • Effect of probe pressure on cervical fluorescence spectroscopy measurements.

    abstract::Fluorescence spectroscopy is a promising technology for detection of epithelial precancers and cancers. While age and menopausal status influence measurements in the cervix, other variables do not significantly affect the diagnosis. In this study we examine probe pressure as a variable. A fiber optic probe to measure ...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.1695562

    authors: Nath A,Rivoire K,Chang S,Cox D,Atkinson EN,Follen M,Richards-Kortum R

    更新日期:2004-05-01 00:00:00

  • Near-infrared fluorescence goggle system with complementary metal-oxide-semiconductor imaging sensor and see-through display.

    abstract::We have developed a near-infrared (NIR) fluorescence goggle system based on the complementary metal-oxide-semiconductor active pixel sensor imaging and see-through display technologies. The fluorescence goggle system is a compact wearable intraoperative fluorescence imaging and display system that can guide surgery in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.101303

    authors: Liu Y,Njuguna R,Matthews T,Akers WJ,Sudlow GP,Mondal S,Tang R,Gruev V,Achilefu S

    更新日期:2013-10-01 00:00:00

  • Analyzing near-infrared scattering from human skin to monitor changes in hematocrit.

    abstract::Probing tissue with near-infrared radiation (NIR) simultaneously produces remitted fluorescence and Raman scattering (IE) plus Rayleigh∕Mie light scattering (EE) that noninvasively give chemical and physical information about the materials and objects within. We model tissue as a three-phase system: plasma and red blo...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3625283

    authors: Chaiken J,Deng B,Goodisman J,Shaheen G,Bussjager RJ

    更新日期:2011-09-01 00:00:00

  • Comparison of laser and diode sources for acceleration of in vitro wound healing by low-level light therapy.

    abstract::Low-level light therapy has been shown to improve in vitro wound healing. However, well-defined parameters of different light sources for this therapy are lacking. The goal of this study was (1) to determine if the wavelengths tested are effective for in vitro wound healing and (2) to compare a laser and a light-emitt...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.3.038001

    authors: Spitler R,Berns MW

    更新日期:2014-03-01 00:00:00

  • Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

    abstract::Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for var...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.056009

    authors: Dixon AJ,Hossack JA

    更新日期:2013-05-01 00:00:00

  • Myocardial tissue oxygenation estimated with calibrated diffuse reflectance spectroscopy during coronary artery bypass grafting.

    abstract::We present a study using a method able to assess tissue oxygenation, taking into account the absorption and the level of scattering in myocardial tissue using a calibrated fiber optic probe. With this method, interindividual comparisons of oxygenation can be made despite varying tissue optical properties during corona...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.2976433

    authors: Häggblad E,Lindbergh T,Karlsson MG,Casimir-Ahn H,Salerud EG,Strömberg T

    更新日期:2008-09-01 00:00:00

  • High-magnification vascular imaging to reject false-positive sites in situ during Hexvix® fluorescence cystoscopy.

    abstract::Fluorescence imaging for detection of non-muscle-invasive bladder cancer is based on the selective production and accumulation of fluorescing porphyrins-mainly, protoporphyrin IX-in cancerous tissues after the instillation of Hexvix®. Although the sensitivity of this procedure is very good, its specificity is somewhat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3484257

    authors: Lovisa B,Jichlinski P,Weber BC,Aymon D,van den Bergh H,Wagnières G

    更新日期:2010-09-01 00:00:00

  • Volume holographic imaging endoscopic design and construction techniques.

    abstract::A reflectance volume holographic imaging (VHI) endoscope has been designed for simultaneous in vivo imaging of surface and subsurface tissue structures. Prior utilization of VHI systems has been limited to ex vivo tissue imaging. The VHI system presented in this work is designed for laparoscopic use. It consists of a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.056010

    authors: Howlett ID,Han W,Gordon M,Rice P,Barton JK,Kostuk RK

    更新日期:2017-05-01 00:00:00

  • Automated three-dimensional morphology-based clustering of human erythrocytes with regular shapes: stomatocytes, discocytes, and echinocytes.

    abstract::We present unsupervised clustering methods for automatic grouping of human red blood cells (RBCs) extracted from RBC quantitative phase images obtained by digital holographic microscopy into three RBC clusters with regular shapes, including biconcave, stomatocyte, and sphero-echinocyte. We select some good features re...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.7.076015

    authors: Ahmadzadeh E,Jaferzadeh K,Lee J,Moon I

    更新日期:2017-07-01 00:00:00

  • Early detection of high-grade squamous intraepithelial lesions in the cervix with quantitative spectroscopic imaging.

    abstract::Quantitative spectroscopy has recently been extended from a contact-probe to wide-area spectroscopic imaging to enable mapping of optical properties across a wide area of tissue. We train quantitative spectroscopic imaging (QSI) to identify cervical high-grade squamous intraepithelial lesions (HSILs) in 34 subjects un...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.076013

    authors: Lau C,Mirkovic J,Yu CC,O'Donoghue GP,Galindo L,Dasari R,de las Morenas A,Feld M,Stier E

    更新日期:2013-07-01 00:00:00

  • Hardware implementation algorithm and error analysis of high-speed fluorescence lifetime sensing systems using center-of-mass method.

    abstract::A new, simple, high-speed, and hardware-only integration-based fluorescence-lifetime-sensing algorithm using a center-of-mass method (CMM) is proposed to implement lifetime calculations, and its signal-to-noise-ratio based on statistics theory is also deduced. Compared to the commonly used iterative least-squares meth...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3309737

    authors: Li DU,Rae B,Andrews R,Arlt J,Henderson R

    更新日期:2010-01-01 00:00:00

  • Diffuse reflectance spectroscopy to monitor murine colorectal tumor progression and therapeutic response (Erratum).

    abstract::The erratum notes a correction to Fig. 5 for the published article. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,已发布勘误

    doi:10.1117/1.JBO.25.4.049803

    authors: Mundo AI,Greening GJ,Fahr MJ,Hale LN,Bullard EA,Rajaram N,Muldoon TJ

    更新日期:2020-04-01 00:00:00

  • Propagation of coherent polarized light in turbid highly scattering medium.

    abstract::Within the framework of further development of unified Monte Carlo code for the needs of biomedical optics and biophotonics, we present an approach for modeling of coherent polarized light propagation in highly scattering turbid media, such as biological tissues. The temporal coherence of light, linear and circular po...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.2.025005

    authors: Doronin A,Macdonald C,Meglinski I

    更新日期:2014-02-01 00:00:00

  • Comparison between optical-resolution photoacoustic microscopy and confocal laser scanning microscopy for turbid sample imaging.

    abstract::Optical-resolution photoacoustic microscopy (ORPAM) in theory provides lateral resolution equivalent to the optical diffraction limit. Scattering media, such as biological turbid media, attenuates the optical signal and also alters the diffraction-limited spot size of the focused beam. The ORPAM signal is generated on...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.121202

    authors: U-Thainual P,Kim DH

    更新日期:2015-12-01 00:00:00

  • Multiphoton adaptation of a commercial low-cost confocal microscope for live tissue imaging.

    abstract::The Nikon C1 confocal laser scanning microscope is a relatively inexpensive and user-friendly instrument. We describe a straightforward method to convert the C1 for multiphoton microscopy utilizing direct coupling of a femtosecond near-infrared laser into the scan head and fiber optic transmission of emission light to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3139850

    authors: Mancuso JJ,Larson AM,Wensel TG,Saggau P

    更新日期:2009-05-01 00:00:00

  • No-core fiber-based highly sensitive optical fiber pH sensor.

    abstract::The present work describes the fabrication and characterization of an optical fiber pH sensor using a sol–gel technique. The sensing head configuration is incorporated using a short section of no-core fiber, coated with tetraethyl orthosilicate and spliced at the end of a single mode fiber with a bulge. Different type...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.057001

    authors: Bhardwaj V,Pathak AK,Singh VK

    更新日期:2017-05-01 00:00:00

  • Functional imaging of dye concentration in tissue phantoms by spectroscopic optical coherence tomography.

    abstract::We present functional imaging of the concentration of a photodynamic therapy (PDT)-related dye in scattering tissue phantoms based on spatially resolved measurements of optical properties through spectroscopic optical coherence tomography (OCT). Expressions for the OCT signal are developed, enabling estimation of dept...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1898242

    authors: Støren T,Røyset A,Svaasand LO,Lindmo T

    更新日期:2005-03-01 00:00:00

  • Rapid confocal imaging of large areas of excised tissue with strip mosaicing.

    abstract::Imaging large areas of tissue rapidly and with high resolution may enable rapid pathology at the bedside. The limited field of view of high-resolution microscopes requires the merging of multiple images that are taken sequentially to cover a large area. This merging or mosaicing of images requires long acquisition and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3582335

    authors: Abeytunge S,Li Y,Larson B,Toledo-Crow R,Rajadhyaksha M

    更新日期:2011-05-01 00:00:00

  • Dynamic in vivo imaging of small animal brain using pulsed laser diode-based photoacoustic tomography system.

    abstract::We demonstrate dynamic in vivo imaging using a low-cost portable pulsed laser diode (PLD)-based photoacoustic tomography system. The system takes advantage of an 803-nm PLD having high-repetition rate ∼7000  Hz combined with a fast-scanning single-element ultrasound transducer leading to a 5 s cross-sectional imaging....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.090501

    authors: Upputuri PK,Pramanik M

    更新日期:2017-09-01 00:00:00

  • New aspects in assessment of changes in width of subarachnoid space with near-infrared transillumination-backscattering sounding, part 2: clinical verification in the patient.

    abstract::The study presents comparison of near-infrared light propagation and near-infrared backscattered radiation power, as simulated with numerical modeling and measured live in a patient in clinical conditions with the use of the near-infrared transillumination-backscattering sounding (NIR-TBSS) technique. A unique chance ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2753756

    authors: Frydrychowski AF,Pluciński J

    更新日期:2007-07-01 00:00:00

  • Study of cadmium-induced cytotoxicity using two-photon excitation endogenous fluorescence microscopy.

    abstract::We demonstrate that using time-resolved two-photon excitation endogenous fluorescence microscopy, the cadmium (Cd)-induced cellular toxic level can be assessed by the free-to protein-bound reduced nicotinamide adenine dinucleotide (free/bound NADH) ratio in a living cell. NADH fluorescence excited at 730 nm is capture...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3250293

    authors: Li D,Yang MS,Lin T,Zheng W,Qu JY

    更新日期:2009-09-01 00:00:00

  • Band analysis of hydrated human skin stratum corneum attenuated total reflectance fourier transform infrared spectra in vivo.

    abstract::Water content is an important factor for skin condition. The determination of the hydration state of the skin is necessary to obtain basic knowledge about the penetration and loss of water in the skin stratum corneum. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy is used to measure hy...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429890

    authors: Lucassen GW,van Veen GN,Jansen JA

    更新日期:1998-07-01 00:00:00

  • Blood screening using diffraction phase cytometry.

    abstract::Blood smear analysis has remained a crucial diagnostic tool for pathologists despite the advent of automatic analyzers such as flow cytometers and impedance counters. Though these current methods have proven to be indispensible tools for physicians and researchers alike, they provide limited information on the detaile...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3369965

    authors: Mir M,Ding H,Wang Z,Reedy J,Tangella K,Popescu G

    更新日期:2010-03-01 00:00:00

  • High-speed upper-airway imaging using full-range optical coherence tomography.

    abstract::Obstruction in the upper airway can often cause reductions in breathing or gas exchange efficiency and lead to rest disorders such as sleep apnea. Imaging diagnosis of the obstruction region has been accomplished using computed tomography (CT) and magnetic resonance imaging (MRI). However CT requires the use of ionizi...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.jbo.17.11.110507

    authors: Jing J,Zhang J,Loy AC,Wong BJ,Chen Z

    更新日期:2012-11-01 00:00:00

  • Light scattering of human red blood cells during metabolic remodeling of the membrane.

    abstract::We present the light scattering properties of individual human red blood cells (RBCs). We show that both the RBC static and dynamic scattering signals are altered by adenosine 5'-triphosphate (ATP)-driven membrane metabolic remodeling. To measure the light scattering signal from individual RBCs, we use diffraction pha...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3524509

    authors: Park Y,Best-Popescu CA,Dasari RR,Popescu G

    更新日期:2011-01-01 00:00:00

  • Bioluminescence of Vibrio fischeri: bacteria respond quickly and sensitively to pulsed microwave electric (but not magnetic) fields.

    abstract::Biological systems with intrinsic luminescent properties serve as powerful and noninvasive bioreporters for real-time and label-free monitoring of cell physiology. This study employs the bioluminescent marine bacterium Vibrio fischeri to investigate the effects of separated microwave electric (E) and magnetic (H) fiel...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.5.051412

    authors: Williams CF,Geroni GM,Lloyd D,Choi H,Clark N,Pirog A,Lees J,Porch A

    更新日期:2019-02-01 00:00:00

  • Detection of enzyme activity in orthotopic murine breast cancer by fluorescence lifetime imaging using a fluorescence resonance energy transfer-based molecular probe.

    abstract::Cancer-related enzyme activity can be detected noninvasively using activatable fluorescent molecular probes. In contrast to "always-on" fluorescent molecular probes, activatable probes are relatively nonfluorescent at the time of administration due to intramolecular fluorescence resonance energy transfer (FRET). Enzym...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3594153

    authors: Solomon M,Guo K,Sudlow GP,Berezin MY,Edwards WB,Achilefu S,Akers WJ

    更新日期:2011-06-01 00:00:00

  • Blind deconvolution estimation of fluorescence measurements through quadratic programming.

    abstract::Time-deconvolution of the instrument response from fluorescence lifetime imaging microscopy (FLIM) data is usually necessary for accurate fluorescence lifetime estimation. In many applications, however, the instrument response is not available. In such cases, a blind deconvolution approach is required. An iterative me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075010

    authors: Campos-Delgado DU,Gutierrez-Navarro O,Arce-Santana ER,Skala MC,Walsh AJ,Jo JA

    更新日期:2015-07-01 00:00:00

  • Resolution in the ApoTome and the confocal laser scanning microscope: comparison.

    abstract::The essential feature of the confocal laser scanning microscope (cLSM) is the generation of optical sections by the removal of out-of-focus light. About ten years ago, structured illumination microscopy (SIM) was introduced as an alternative method for obtaining optical sections from biological specimens. Here we comp...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3083439

    authors: Weigel A,Schild D,Zeug A

    更新日期:2009-01-01 00:00:00

  • Multiplexed neural recording along a single optical fiber via optical reflectometry.

    abstract::We introduce the design and theoretical analysis of a fiber-optic architecture for neural recording without contrast agents, which transduces neural electrical signals into a multiplexed optical readout. Our sensor design is inspired by electro-optic modulators, which modulate the refractive index of a waveguide by ap...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.5.057003

    authors: Rodriques SG,Marblestone AH,Scholvin J,Dapello J,Sarkar D,Mankin M,Gao R,Wood L,Boyden ES

    更新日期:2016-05-01 00:00:00