Lipid-cell interactions in human monocytes investigated by doubly-resonant coherent anti-Stokes Raman scattering microscopy.

Abstract:

:We demonstrate that doubly-resonant coherent anti-Stokes Raman scattering can provide enhanced and highly specific contrast for molecules containing unique Raman-active small molecular groups. This combination provides contrast for molecules that can otherwise be difficult to discriminate by Raman spectroscopy. Here, human monocytes were incubated with either deuterated oleic acid or 17-octadecynoic acid (a fatty acid with an end terminal acetylene group). The carbon-deuterium stretching vibration of the deuterated fatty acid, as well as the unique alkyne stretching vibration of the alkyne-containing fatty acid, were used to provide contrast for these exogenous free fatty acids. The combination of these unique modes with the common aliphatic carbon-hydrogen stretching vibration inherent to all fatty acid allowed for doubly-resonant detection of these unique molecules and enabled us to detect the presence of these lipids in areas within a cell where each molecular resonance by itself did not generate sufficient signal.

journal_name

J Biomed Opt

authors

Weeks T,Schie I,den Hartigh LJ,Rutledge JC,Huser T

doi

10.1117/1.3544585

subject

Has Abstract

pub_date

2011-02-01 00:00:00

pages

021117

issue

2

eissn

1083-3668

issn

1560-2281

journal_volume

16

pub_type

杂志文章
  • New aspects in assessment of changes in width of subarachnoid space with near-infrared transillumination-backscattering sounding, part 2: clinical verification in the patient.

    abstract::The study presents comparison of near-infrared light propagation and near-infrared backscattered radiation power, as simulated with numerical modeling and measured live in a patient in clinical conditions with the use of the near-infrared transillumination-backscattering sounding (NIR-TBSS) technique. A unique chance ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2753756

    authors: Frydrychowski AF,Pluciński J

    更新日期:2007-07-01 00:00:00

  • FRET-based method for evaluation of the efficiency of reversible and irreversible sonoporation.

    abstract::It is widely known that not all of the treated cells survive after introduction of exogenous molecules via any physical method. Therefore, it is important to develop methods that would allow simultaneous evaluation of both molecular delivery efficiency and cell viability. This study presents Förster resonance energy t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.097001

    authors: Ruzgys P,Tamošiūnas M,Lukinsone V,Šatkauskas S

    更新日期:2017-09-01 00:00:00

  • Real-time intraoperative fluorescence imaging system using light-absorption correction.

    abstract::We present a novel fluorescence imaging system developed for real-time interventional imaging applications. The system implements a correction scheme that improves the accuracy of epi-illumination fluorescence images for light intensity variation in tissues. The implementation is based on the use of three cameras oper...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3259362

    authors: Themelis G,Yoo JS,Soh KS,Schulz R,Ntziachristos V

    更新日期:2009-11-01 00:00:00

  • Spatiotemporal laser speckle contrast analysis for blood flow imaging with maximized speckle contrast.

    abstract::Laser speckle contrast imaging is a technique used for imaging blood flow without scanning. Though several studies have attempted to combine spatial and temporal statistics of laser speckle images for reducing image noise as well as preserving acceptable spatiotemporal resolution, the statistical accuracy of these spa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3290804

    authors: Qiu J,Li P,Luo W,Wang J,Zhang H,Luo Q

    更新日期:2010-01-01 00:00:00

  • Three-dimensional optical method for integrated visualization of mouse islet microstructure and vascular network with subcellular-level resolution.

    abstract::Microscopic visualization of islets of Langerhans under normal and diabetic conditions is essential for understanding the pathophysiology of the disease. The intrinsic opacity of pancreata, however, limits optical accessibility for high-resolution light microscopy of islets in situ. Because the standard microtome-base...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3470241

    authors: Fu YY,Lu CH,Lin CW,Juang JH,Enikolopov G,Sibley E,Chiang AS,Tang SC

    更新日期:2010-07-01 00:00:00

  • Study of the influence of over-the-counter vitamin supplement intake on urine fluorescence to optimize cancer detection by fluorescence cystoscopy.

    abstract::Fluorescence cystoscopy (FC) efficiently enhances the detection and improves the therapeutic management of early bladder cancer. During an FC, about 150 ml of water is needed to inflate the bladder. The water is quickly diluted by urine which can be fluorescent. If this bladder washout fluid (BWF) becomes fluorescent,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.6.066011

    authors: Zellweger M,Martoccia C,Mengin M,Iselin C,van den Bergh H,Wagnières G

    更新日期:2015-06-01 00:00:00

  • Photon migration through fetal head in utero using continuous wave, near-infrared spectroscopy: development and evaluation of experimental and numerical models.

    abstract::In this work experimental tissue phantoms and numerical models were developed to estimate photon migration through the fetal head in utero. The tissue phantoms incorporate a fetal head within an amniotic fluid sac surrounded by a maternal tissue layer. A continuous wave, dual-wavelength (lambda = 760 and 850 nm) spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429983

    authors: Vishnoi G,Hielscher AH,Ramanujam N,Chance B

    更新日期:2000-04-01 00:00:00

  • Imaging tumor hypoxia by near-infrared fluorescence tomography.

    abstract::We have developed a novel nitroimidazole indocyanine dye conjugate for tumor-targeted hypoxia fluorescence tomography. The hypoxia probe has been evaluated in vitro using tumor cell lines and in vivo with tumor targeting in mice. The in vitro cell studies were performed to assess fluorescence labeling differences betw...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3589348

    authors: Biswal NC,Pavlik C,Smith MB,Aguirre A,Xu Y,Zanganeh S,Kuhn LT,Claffey KP,Zhu Q

    更新日期:2011-06-01 00:00:00

  • Analyzing reflectance spectra of human skin in legal medicine.

    abstract::Our current research in the framework of an interdisciplinary project focuses on modelling the dynamics of the hemoglobin reoxygenation process in post-mortem human skin by reflectance spectrometry. The observations of reoxygenation of hemoglobin in livores after postmortem exposure to a cold environment relate the re...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.017004

    authors: Belenki L,Sterzik V,Schulz K,Bohnert M

    更新日期:2013-01-01 00:00:00

  • Optical properties of mouse brain tissue after optical clearing with FocusClear™.

    abstract::Fluorescence microscopy is commonly used to investigate disease progression in biological tissues. Biological tissues, however, are strongly scattering in the visible wavelengths, limiting the application of fluorescence microscopy to superficial (<200µm) regions. Optical clearing, which involves incubation of the tis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.9.095010

    authors: Moy AJ,Capulong BV,Saager RB,Wiersma MP,Lo PC,Durkin AJ,Choi B

    更新日期:2015-01-01 00:00:00

  • Applications of compressive sensing in spatial frequency domain imaging.

    abstract:SIGNIFICANCE:Spatial frequency domain imaging (SFDI) is an imaging modality that projects spatially modulated light patterns to determine optical property maps for absorption and reduced scattering of biological tissue via a pixel-by-pixel data acquisition and analysis procedure. Compressive sensing (CS) is a signal pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.11.112904

    authors: Mellors BOL,Bentley A,Spear AM,Howle CR,Dehghani H

    更新日期:2020-11-01 00:00:00

  • Cutaneous melanin exhibiting fluorescence emission under near-infrared light excitation.

    abstract::Under ultraviolet and visible light excitation, melanin is essentially a nonfluorescent substance. This work reports our study on near-infrared (NIR) fluorescence properties of melanins, and explores potential applications of NIR fluorescence techniques for evaluating skin disorders involving melanin. The NIR fluoresc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2204007

    authors: Huang Z,Zeng H,Hamzavi I,Alajlan A,Tan E,McLean DI,Lui H

    更新日期:2006-05-01 00:00:00

  • Bipolar cellular morphology of malignant melanoma in unstained human melanoma skin tissue.

    abstract::Microstructures of unstained human melanoma skin tissues have been examined by multimodal nonlinear optical microscopy. The polarized shape of the individual melanoma cell can be readily recognized-a phenotype that has been identified in laboratory cultures as characteristic of proliferating melanocytes but has not be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3120491

    authors: Zhang K,Zhang W,Yang CY,Yang H

    更新日期:2009-03-01 00:00:00

  • Three-dimensional surface reconstruction within noncontact diffuse optical tomography using structured light.

    abstract::A main field in biomedical optics research is diffuse optical tomography, where intensity variations of the transmitted light traversing through tissue are detected. Mathematical models and reconstruction algorithms based on finite element methods and Monte Carlo simulations describe the light transport inside the tis...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.12.126009

    authors: Baum K,Hartmann R,Bischoff T,Oelerich JO,Finkensieper S,Heverhagen JT

    更新日期:2012-12-01 00:00:00

  • Fluorescence Talbot microscope using incoherent source.

    abstract::Fluorescence Talbot microscope is a scalable field-of-view (FOV) imaging platform, which takes advantage of the phase sensitivity of the self-image of a periodic structure. Such a system can maintain the microscopic resolution and extend the FOV for the whole slide (15  mm×15  mm) scanning. Previously reported Talbot ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.8.086003

    authors: Sun Y,Pang S

    更新日期:2016-08-01 00:00:00

  • Model-based spectroscopic analysis of the oral cavity: impact of anatomy.

    abstract::In order to evaluate the impact of anatomy on the spectral properties of oral tissue, we used reflectance and fluorescence spectroscopy to characterize nine different anatomic sites. All spectra were collected in vivo from healthy oral mucosa. We analyzed 710 spectra collected from the oral cavity of 79 healthy volunt...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2992139

    authors: McGee S,Mirkovic J,Mardirossian V,Elackattu A,Yu CC,Kabani S,Gallagher G,Pistey R,Galindo L,Badizadegan K,Wang Z,Dasari R,Feld MS,Grillone G

    更新日期:2008-11-01 00:00:00

  • Confocal reflectance and two-photon microscopy studies of a songbird skull for preparation of transcranial imaging.

    abstract::We present experiments and analyses of confocal reflectance and two-photon microscopy studies of zebra finch skull samples. The thin and hollow structure of these birds' skulls is quite translucent, which can allow in vivo transcranial two-photon imaging for brain activation monitoring. However, the skull structure is...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3155522

    authors: Abi-Haidar D,Olivier T

    更新日期:2009-05-01 00:00:00

  • Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is an emerging technology for high-resolution, noncontact imaging of transparent and scattering media. Polarization-sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT that can image birefringent properties of a biological sample. PS-OCT was used to measu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1629308

    authors: Götzinger E,Pircher M,Sticker M,Fercher AF,Hitzenberger CK

    更新日期:2004-01-01 00:00:00

  • Light propagation in a turbid medium with insonified microbubbles.

    abstract::Surfactant stabilized microbubbles are widely used clinical contrast agents for ultrasound imaging. In this work, the light propagation through a turbid medium in the presence of microbubbles has been investigated. Through a series of experiments, it has been found that the optical attenuation is increased when the mi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.1.015002

    authors: Leung TS,Honeysett JE,Stride E,Deng J

    更新日期:2013-01-01 00:00:00

  • Image reconstruction in photoacoustic tomography with variable speed of sound using a higher-order geometrical acoustics approximation.

    abstract::Previous research correcting for variable speed of sound in photoacoustic tomography (PAT) based on a generalized radon transform (GRT) model assumes first-order geometrical acoustics (GA) approximation. In the GRT model, the pressure is related to the optical absorption, in an acoustically inhomogeneous medium, throu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3333550

    authors: Modgil D,Anastasio MA,La Rivière PJ

    更新日期:2010-03-01 00:00:00

  • Noncontact photoacoustic tomography of in vivo chicken chorioallantoic membrane based on all-fiber heterodyne interferometry.

    abstract::We present three-dimensional (3-D) in vivo photoacoustic (PA) images of the blood vasculature of a chicken chorioallantoic membrane (CAM) obtained by using a fiber-based noncontact PA tomography system. With a fiber-optic heterodyne interferometer, the system measures the surface displacement of a sample, induced by t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.10.106007

    authors: Eom J,Park SJ,Lee BH

    更新日期:2015-10-01 00:00:00

  • Ex vivo optical metabolic measurements from cultured tissue reflect in vivo tissue status.

    abstract::Optical measurements of metabolism are ideally acquired in vivo; however, intravital measurements are often impractical. Accurate ex vivo assessments would greatly broaden the applicability of optical measurements of metabolism. We investigate the use of live tissue culture experiments to serve as a surrogate for in v...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.116015

    authors: Walsh AJ,Poole KM,Duvall CL,Skala MC

    更新日期:2012-11-01 00:00:00

  • Waveguide evanescent field fluorescence microscopy: high contrast imaging of a domain forming mixed lipid Langmuir-Blodgett monolayer mimicking lung surfactant.

    abstract::Waveguide evanescent field fluorescence (WEFF) microscopy is a new development that allows the imaging of contact regions between biological cells and their substratum, as well as imaging of ultrathin films such as monomolecular Langmuir-Blodgett (LB) films. Mixed-lipid monolayer systems mimicking lung surfactant were...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3569095

    authors: Hassanzadeh A,Mittler S

    更新日期:2011-04-01 00:00:00

  • Near-infrared fluorescence goggle system with complementary metal-oxide-semiconductor imaging sensor and see-through display.

    abstract::We have developed a near-infrared (NIR) fluorescence goggle system based on the complementary metal-oxide-semiconductor active pixel sensor imaging and see-through display technologies. The fluorescence goggle system is a compact wearable intraoperative fluorescence imaging and display system that can guide surgery in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.101303

    authors: Liu Y,Njuguna R,Matthews T,Akers WJ,Sudlow GP,Mondal S,Tang R,Gruev V,Achilefu S

    更新日期:2013-10-01 00:00:00

  • Innovative Troxler-free measurement of macular pigment and lens density with correction of the former for the aging lens.

    abstract::Simplified measurement of macular pigment optical density (MPOD) is important because of the ocular health benefits that are attributed to these retinal carotenoids. Here, we describe a novel instrument designed for this purpose, based on heterochromatic flicker photometry (HFP), which removes a number of difficulties...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.10.107003

    authors: Bone RA,Mukherjee A

    更新日期:2013-10-01 00:00:00

  • Dependence of image quality on image operator and noise for optical diffusion tomography.

    abstract::By applying linear perturbation theory to the radiation transport equation, the inverse problem of optical diffusion tomography can be reduced to a set of linear equations, Wμ=R, where W is the weight function, μ are the cross-section perturbations to be imaged, and R is the detector readings perturbations. We have st...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429870

    authors: Chang J,Graber HL,Barbour RL

    更新日期:1998-04-01 00:00:00

  • New method for evaluation of in vivo scattering and refractive index properties obtained with optical coherence tomography.

    abstract::Optical coherence tomography (OCT) provides more parameters than pure morphology does. In a recent paper [A. Knuettel and M. Boehlau-Godau, J. Biomed. Opt. 5(1) 83-92 (2000)] we have shown that the refractive index (RI) can be evaluated in a localized manner in skin tissue under in vivo conditions. Based on a theory, ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1647544

    authors: Knüttel A,Bonev S,Knaak W

    更新日期:2004-03-01 00:00:00

  • Analysis of red blood cell parameters by Talbot-projected fringes.

    abstract::Red blood cell (RBC) anomalies are significant symptoms for identification of health disorders and several blood diseases, which involve the modification of the parameters and biophysical characteristics of such cells. The aim of this study is to measure the three-dimensional phase information of healthy RBCs and thei...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.10.106009

    authors: Agarwal S,Kumar V,Shakher C

    更新日期:2017-10-01 00:00:00

  • Quantitative assessment of radiation-induced changes of bladder and rectum collagen structure using optical methods.

    abstract::The objective of the study is the quantitative analysis of the dose-time dependences of changes occurring in collagen of bladder and rectum after gamma-irradiation using optical methods [nonlinear microscopy in a second harmonic generation (SHG) detection regime and cross-polarization optical coherence tomography (CP ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.091417

    authors: Kochueva M,Dudenkova V,Kuznetsov S,Varlamova A,Sergeeva E,Kiseleva E,Maslennikova A

    更新日期:2018-08-01 00:00:00

  • Visible-wavelength two-photon excitation microscopy with multifocus scanning for volumetric live-cell imaging.

    abstract::Two-photon excitation microscopy is one of the key techniques used to observe three-dimensional (3-D) structures in biological samples. We utilized a visible-wavelength laser beam for two-photon excitation in a multifocus confocal scanning system to improve the spatial resolution and image contrast in 3-D live-cell im...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.1.014502

    authors: Oketani R,Suda H,Uegaki K,Kubo T,Matsuda T,Yamanaka M,Arai Y,Smith N,Nagai T,Fujita K

    更新日期:2019-11-01 00:00:00