Noncontact photoacoustic tomography of in vivo chicken chorioallantoic membrane based on all-fiber heterodyne interferometry.

Abstract:

:We present three-dimensional (3-D) in vivo photoacoustic (PA) images of the blood vasculature of a chicken chorioallantoic membrane (CAM) obtained by using a fiber-based noncontact PA tomography system. With a fiber-optic heterodyne interferometer, the system measures the surface displacement of a sample, induced by the PA wave, which overcomes the disadvantage of physical-contact of ultrasonic transducer in a conventional system. The performance of an implemented system is analyzed and its capability of in vivo 3-D bioimaging is presented. At a depth of 2.5 mm in a phantom experiment, the lateral and axial resolutions were measured as 100 and 30  μm, respectively. The lateral resolution became doubled at a depth of 7.0 mm; however, interestingly, the axial resolution was not noticeably deteriorated with the depth. With the CAM experiment, performed under the American National Standards Institute laser safety standard condition, blood vessel structures placed as deep as 3.5 mm were clearly recognized.

journal_name

J Biomed Opt

authors

Eom J,Park SJ,Lee BH

doi

10.1117/1.JBO.20.10.106007

subject

Has Abstract

pub_date

2015-10-01 00:00:00

pages

106007

issue

10

eissn

1083-3668

issn

1560-2281

pii

2464649

journal_volume

20

pub_type

杂志文章
  • Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is an emerging technology for high-resolution, noncontact imaging of transparent and scattering media. Polarization-sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT that can image birefringent properties of a biological sample. PS-OCT was used to measu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1629308

    authors: Götzinger E,Pircher M,Sticker M,Fercher AF,Hitzenberger CK

    更新日期:2004-01-01 00:00:00

  • Modeling optical behavior of birefringent biological tissues for evaluation of quantitative polarized light microscopy.

    abstract::Quantitative polarized light microscopy (qPLM) is a popular tool for the investigation of birefringent architectures in biological tissues. Collagen, the most abundant protein in mammals, is such a birefringent material. Interpretation of results of qPLM in terms of collagen network architecture and anisotropy is chal...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3241986

    authors: van Turnhout MC,Kranenbarg S,van Leeuwen JL

    更新日期:2009-09-01 00:00:00

  • Processing algorithms for tracking speckle shifts in optical elastography of biological tissues.

    abstract::Parametric and nonparametric data processing schemes for analyzing translating laser speckle data used to investigate the mechanical behavior of biological tissues are examined. Cross-correlation, minimum mean square estimator, maximum likelihood, and maximum entropy approaches are discussed and compared on speckle da...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1412224

    authors: Duncan DD,Kirkpatrick SJ

    更新日期:2001-10-01 00:00:00

  • Quantitative concentration measurements of creatinine dissolved in water and urine using Raman spectroscopy and a liquid core optical fiber.

    abstract::We describe the use of a Teflon-AF liquid core optical fiber (LCOF) geometry to enhance the collection of Raman scattering from the biochemical creatinine, dissolved in water and in urine. At short integration times, where shot noise is most troublesome, the enhanced signal leads to greater accuracy in estimating the ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1917842

    authors: Qi D,Berger AJ

    更新日期:2005-05-01 00:00:00

  • Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics.

    abstract::Application of a fiber optic biosensor (FOB) to the real-time investigation of the interaction kinetics between FITC-conjugated monoclonal sheep anti-human C-reactive protein (CRP) antibody and CRP isoforms on the surface of optical fiber is described. Recently, both the native pentameric CRP (pCRP), an acute phase pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714029

    authors: Chou C,Hsu HY,Wu HT,Tseng KY,Chiou A,Yu CJ,Lee ZY,Chan TS

    更新日期:2007-03-01 00:00:00

  • Evaluation of the contribution of the renal capsule and cortex to kidney autofluorescence intensity under ultraviolet excitation.

    abstract::The use of reduced nicotinamide adenine dinucleotide (NADH) fluorescence to gain metabolic information on kidneys in response to an alteration in oxygen availability has previously been experimentally demonstrated, but signal quantification has not, to date, been addressed. In this work the relative contribution to ra...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3094948

    authors: Raman RN,Pivetti CD,Rubenchik AM,Matthews DL,Troppmann C,Demos SG

    更新日期:2009-03-01 00:00:00

  • Confocal detection of planar homogeneous and heterogeneous immunosorbent assays.

    abstract::Optically sectioned detection of fluorescence immunoassays using a confocal microscope enables the creation of both homo- and heterogeneous planar format assays. We report a set assays requiring optically sectioned detection using a model system and analysis procedures for separating signals of a surface layer from an...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3268772

    authors: Ghafari H,Zhou Y,Ali S,Hanley QS

    更新日期:2009-11-01 00:00:00

  • Quantitative phase microscopy of articular chondrocyte dynamics by wide-field digital interferometry.

    abstract::We experimentally implement label-free phase microscopy using wide-field digital interferometry (WFDI) techniques to retrieve quantitative volumetric data of articular chondrocyte dynamics. Using the scanless interferometric system, we visualize chondrocyte swelling and bursting induced by hypo-osmotic pressure. Recon...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3290242

    authors: Shaked NT,Finan JD,Guilak F,Wax A

    更新日期:2010-01-01 00:00:00

  • FLIM data analysis based on Laguerre polynomial decomposition and machine-learning.

    abstract:SIGNIFICANCE:The potential of fluorescence lifetime imaging microscopy (FLIM) is recently being recognized, especially in biological studies. However, FLIM does not directly measure the lifetimes, rather it records the fluorescence decay traces. The lifetimes and/or abundances have to be estimated from these traces dur...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.26.2.022909

    authors: Guo S,Silge A,Bae H,Tolstik T,Meyer T,Matziolis G,Schmitt M,Popp J,Bocklitz T

    更新日期:2021-01-01 00:00:00

  • Noninvasive measurements of carotenoids in bovine udder by reflection spectroscopy.

    abstract::For a long time, the antioxidative status in cattle has been discussed as an indicator for stress conditions resulting from disease or exertion. Until now, invasive approaches have been necessary to obtain blood samples or biopsy materials and gain insights into the antioxidative status of cattle. Due to these efforts...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.10.101514

    authors: Klein J,Darvin ME,Müller KE,Lademann J

    更新日期:2012-10-01 00:00:00

  • Rapid convergence to the inverse solution regularized with Lorentzian distributed function for near-infrared continuous wave diffuse optical tomography.

    abstract::A promising method to achieve rapid convergence for image reconstruction is introduced for the continuous-wave near-infrared (NIR) diffuse optical tomography (DOT). Tomographic techniques are usually implemented off line and are time consuming to realize image reconstruction, especially for NIR DOT. Therefore, it is e...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3299727

    authors: Pan MC,Pan MC

    更新日期:2010-01-01 00:00:00

  • Curved array photoacoustic tomographic system for small animal imaging.

    abstract::We present systematic characterization of a photoacoustic imaging system optimized for rapid, high-resolution tomographic imaging of small animals. The system is based on a 128-element ultrasonic transducer array with a 5-MHz center frequency and 80% bandwidth shaped to a quarter circle of 25 mm radius. A 16-channel d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2907157

    authors: Gamelin J,Aguirre A,Maurudis A,Huang F,Castillo D,Wang LV,Zhu Q

    更新日期:2008-03-01 00:00:00

  • Unsupervised analysis of small animal dynamic Cerenkov luminescence imaging.

    abstract::Clustering analysis (CA) and principal component analysis (PCA) were applied to dynamic Cerenkov luminescence images (dCLI). In order to investigate the performances of the proposed approaches, two distinct dynamic data sets obtained by injecting mice with (32)P-ATP and (18)F-FDG were acquired using the IVIS 200 optic...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3663442

    authors: Spinelli AE,Boschi F

    更新日期:2011-12-01 00:00:00

  • Distinguishing tracheal and esophageal tissues with hyperspectral imaging and fiber-optic sensing.

    abstract::During emergency medical situations, where the patient has an obstructed airway or necessitates respiratory support, endotracheal intubation (ETI) is the medical technique of placing a tube into the trachea in order to facilitate adequate ventilation of the lungs. Complications during ETI, such as repeated attempts, f...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.117004

    authors: Nawn CD,Souhan BE,Carter R 3rd,Kneapler C,Fell N,Ye JY

    更新日期:2016-11-01 00:00:00

  • Spectral classifier design with ensemble classifiers and misclassification-rejection: application to elastic-scattering spectroscopy for detection of colonic neoplasia.

    abstract::Optical spectroscopy has shown potential as a real-time, in vivo, diagnostic tool for identifying neoplasia during endoscopy. We present the development of a diagnostic algorithm to classify elastic-scattering spectroscopy (ESS) spectra as either neoplastic or non-neoplastic. The algorithm is based on pattern recognit...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3592488

    authors: Rodriguez-Diaz E,Castanon DA,Singh SK,Bigio IJ

    更新日期:2011-06-01 00:00:00

  • Tool for simulating the focusing of arbitrary vector beams in free-space and stratified media.

    abstract::Vectorial models of focused beams are important to a variety of fields including microscopy, lithography, optical physics, and biomedical imaging. This has led to many models being developed, which calculate how beams of various profiles are focused both in free space and in the presence of stratified media. The major...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.9.090801

    authors: Munro PRT

    更新日期:2018-09-01 00:00:00

  • Time-resolved diffuse optical tomography and its application to in vitro and in vivo imaging.

    abstract::This work reviews our research during the past several years on time-resolved (TR) near-infrared diffuse optical tomography (DOT). Following an introduction of the measuring modes, two proposed schemes of image reconstruction in TR-DOT are described: one utilizes the full TR data, and the other, referred to as the mod...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.2815724

    authors: Zhao H,Gao F,Tanikawa Y,Yamada Y

    更新日期:2007-11-01 00:00:00

  • Photochemical effects and hypericin photosensitized processes in collagen.

    abstract::Emission and excitation spectra of collagen were recorded in the ultraviolet and visible regions. The existence of several types of chromophores absorbing and emitting throughout these spectral regions was observed. It was shown that laser irradiation at 355 and 532 nm caused collagen fluorescence photobleaching by 30...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1331559

    authors: Yova D,Hovhannisyan V,Theodossiou T

    更新日期:2001-01-01 00:00:00

  • Fluorescence microscopy imaging of electroperturbation in mammalian cells.

    abstract::We report the design, integration, and validation of a fluorescence microscopy system for imaging of electroperturbation--the effects of nanosecond, megavolt-per-meter pulsed electric fields on biological cells and tissues. Such effects have potential applications in cancer therapy, gene regulation, and biophysical re...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2187970

    authors: Sun Y,Vernier PT,Behrend M,Wang J,Thu MM,Gundersen M,Marcu L

    更新日期:2006-03-01 00:00:00

  • Optically tunable nanoparticle contrast agents for early cancer detection: model-based analysis of gold nanoshells.

    abstract::Many optical diagnostic approaches rely on changes in scattering and absorption properties to generate optical contrast between normal and diseased tissue. Recently, there has been increasing interest in using exogenous agents to enhance this intrinsic contrast with particular emphasis on the development for targeting...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2141825

    authors: Lin AW,Lewinski NA,West JL,Halas NJ,Drezek RA

    更新日期:2005-11-01 00:00:00

  • In vivo wide-field multispectral scanning laser ophthalmoscopy-optical coherence tomography mouse retinal imager: longitudinal imaging of ganglion cells, microglia, and Müller glia, and mapping of the mouse retinal and choroidal vasculature.

    abstract::Scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT) provide complementary views of the retina, with the former collecting fluorescence data with good lateral but relatively low-axial resolution, and the latter collecting label-free backscattering data with comparable lateral but much higher axia...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.126005

    authors: Zhang P,Zam A,Jian Y,Wang X,Li Y,Lam KS,Burns ME,Sarunic MV,Pugh EN Jr,Zawadzki RJ

    更新日期:2015-01-01 00:00:00

  • Comparison of laser and diode sources for acceleration of in vitro wound healing by low-level light therapy.

    abstract::Low-level light therapy has been shown to improve in vitro wound healing. However, well-defined parameters of different light sources for this therapy are lacking. The goal of this study was (1) to determine if the wavelengths tested are effective for in vitro wound healing and (2) to compare a laser and a light-emitt...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.3.038001

    authors: Spitler R,Berns MW

    更新日期:2014-03-01 00:00:00

  • Quantification of in vivo fluorescence decoupled from the effects of tissue optical properties using fiber-optic spectroscopy measurements.

    abstract::We present a method for tissue fluorescence quantification in situ using a handheld fiber optic probe that measures both the fluorescence and diffuse reflectance spectra. A simplified method to decouple the fluorescence spectrum from distorting effects of the tissue optical absorption and scattering is developed, with...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3523616

    authors: Kim A,Khurana M,Moriyama Y,Wilson BC

    更新日期:2010-11-01 00:00:00

  • Real-time oncological guidance using diffuse reflectance spectroscopy in electrosurgery: the effect of coagulation on tissue discrimination.

    abstract::In breast surgery, a lack of knowledge about what is below the tissue surface may lead to positive tumor margins and iatrogenic damage. Diffuse reflectance spectroscopy (DRS) is a spectroscopic technique that can distinguish between healthy and tumor tissue making it a suitable technology for intraoperative guidance. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.11.115004

    authors: Adank MW,Fleischer JC,Dankelman J,Hendriks BHW

    更新日期:2018-11-01 00:00:00

  • Surface plasmon-based infrared spectroscopy for cell biosensing.

    abstract::Cell morphology is often used as a valuable indicator of the physical condition and general status of living cells. We demonstrate a noninvasive method for morphological characterization of adherent cells. We measure infrared reflectivity spectrum at oblique angle from living cells cultured on thin Au film, and utiliz...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.081409

    authors: Yashunsky V,Lirtsman V,Zilbershtein A,Bein A,Schwartz B,Aroeti B,Golosovsky M,Davidov D

    更新日期:2012-08-01 00:00:00

  • Design and validation of an angle-resolved low-coherence interferometry fiber probe for in vivo clinical measurements of depth-resolved nuclear morphology.

    abstract::We present a novel Fourier-domain angle-resolved low-coherence interferometry (a /LCI) fiber probe designed for in vivo clinical application in gastrointestinal endoscopy. The a/LCI technique measures the depth-resolved angular scattering distribution to determine the size distribution and optical density of cell nucl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3520130

    authors: Zhu Y,Terry NG,Woosley JT,Shaheen NJ,Wax A

    更新日期:2011-01-01 00:00:00

  • High-spatial-resolution deep tissue imaging with spectral-domain optical coherence microscopy in the 1700-nm spectral band.

    abstract::We present three-dimensional (3-D) high-resolution spectral-domain optical coherence microscopy (SD-OCM) by using a supercontinuum (SC) fiber laser source with 300-nm spectral bandwidth (full-width at half-maximum) in the 1700-nm spectral band. By using low-coherence interferometry with SC light and a confocal detecti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.7.070502

    authors: Yamanaka M,Hayakawa N,Nishizawa N

    更新日期:2019-07-01 00:00:00

  • Properties of erythrocyte light refraction in diabetic patients.

    abstract::Since hyperglycaemia changes the erythrocyte cell membrane fluidity and impairs cell deformity, our goal was to characterize hemoglobin and red blood cell (RBC) light refractive property changes in diabetic patients. Microscopic investigation was carried out on intact and fixed RBCs. To determine the refractive index ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1463043

    authors: Mazarevica G,Freivalds T,Jurka A

    更新日期:2002-04-01 00:00:00

  • Vessel orientation-dependent sensitivity of optoacoustic imaging using a linear array transducer.

    abstract::For clinical optoacoustic imaging, linear probes are preferably used because they allow versatile imaging of the human body with real-time display and free-hand probe guidance. The two-dimensional (2-D) optoacoustic image obtained with this type of probe is generally interpreted as a 2-D cross-section of the tissue ju...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.2.026011

    authors: Preisser S,Bush NL,Gertsch-Grover AG,Peeters S,Bailey AE,Bamber JC,Frenz M,Jaeger M

    更新日期:2013-02-01 00:00:00

  • Blood oxygen flux estimation with a combined photoacoustic and high-frequency ultrasound microscopy system: a phantom study.

    abstract::The metabolic rate of oxygen consumption, an important indicator of tissue metabolism, can be expressed as the change of net blood oxygen flux into and out of a tissue region per 100 g of tissue. In this work, we propose a photoacoustic and Doppler ultrasound method for imaging local blood oxygen flux of a single vess...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.3.036012

    authors: Jiang Y,Forbrich A,Harrison T,Zemp RJ

    更新日期:2012-03-01 00:00:00