Quantitative phase microscopy of articular chondrocyte dynamics by wide-field digital interferometry.

Abstract:

:We experimentally implement label-free phase microscopy using wide-field digital interferometry (WFDI) techniques to retrieve quantitative volumetric data of articular chondrocyte dynamics. Using the scanless interferometric system, we visualize chondrocyte swelling and bursting induced by hypo-osmotic pressure. Reconstructed images are obtained by an efficient digital process. We use the resulting images to calculate quantitative temporal-spatial morphological parameters of the cell, with the observed dynamics limited only by the true frame rate of the camera. To show the utility of WFDI in recording articular chondrocyte dynamics, we also provide an experimental comparison of WFDI and differential interference contrast microscopy.

journal_name

J Biomed Opt

authors

Shaked NT,Finan JD,Guilak F,Wax A

doi

10.1117/1.3290242

subject

Has Abstract

pub_date

2010-01-01 00:00:00

pages

010505

issue

1

eissn

1083-3668

issn

1560-2281

journal_volume

15

pub_type

信件
  • Optical coherence tomography in gynecology: a narrative review.

    abstract::Modern gynecologic practice requires noninvasive diagnostics techniques capable of detecting morphological and functional alterations in tissues of female reproductive organs. Optical coherence tomography (OCT) is a promising tool for providing imaging of biotissues with high resolution at depths up to 2 mm. Design of...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.22.12.121709

    authors: Kirillin M,Motovilova T,Shakhova N

    更新日期:2017-12-01 00:00:00

  • Nondestructive inspection of phase transformation in zirconia-containing hip joints by confocal Raman spectroscopy.

    abstract::Environmental metastability of zirconia (ZrO2) ceramic in the human body [represented by a tetragonal-to-monoclinic (t→m) phase transformation] takes place on the surface of the artificial joint and proceeds with time toward its interior. Its quantitative characterization is mandatory for the safety of joint implants ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.12.127002

    authors: Zhu W,Sugano N,Pezzotti G

    更新日期:2013-12-01 00:00:00

  • Real-time in vivo color Doppler optical coherence tomography.

    abstract::Color Doppler optical coherence tomography (CDOCT) is a functional extension of optical coherence tomography (OCT) that can image flow in turbid media. We have developed a CDOCT system capable of imaging flow in real time. Doppler processing of the analog signal is accomplished in hardware in the time domain using a n...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1428291

    authors: Rollins AM,Yazdanfar S,Barton JK,Izatt JA

    更新日期:2002-01-01 00:00:00

  • Overview of diffuse optical tomography and its clinical applications.

    abstract::Near-infrared diffuse optical tomography (DOT), one of the most sophisticated optical imaging techniques for observations through biological tissue, allows 3-D quantitative imaging of optical properties, which include functional and anatomical information. With DOT, it is expected to be possible to overcome the limita...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.21.9.091312

    authors: Hoshi Y,Yamada Y

    更新日期:2016-09-01 00:00:00

  • Early development of optical low-coherence reflectometry and some recent biomedical applications.

    abstract::This paper explains the term low-coherence interferometry, reviews the early development of optical low-coherence reflectometry, and shows some of the paths that led to the field of biomedical optics. This paper demonstrates that early technical developments in the telecommunications industry resulted in a myriad of t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429914

    authors: Masters BR

    更新日期:1999-04-01 00:00:00

  • FRET-based method for evaluation of the efficiency of reversible and irreversible sonoporation.

    abstract::It is widely known that not all of the treated cells survive after introduction of exogenous molecules via any physical method. Therefore, it is important to develop methods that would allow simultaneous evaluation of both molecular delivery efficiency and cell viability. This study presents Förster resonance energy t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.9.097001

    authors: Ruzgys P,Tamošiūnas M,Lukinsone V,Šatkauskas S

    更新日期:2017-09-01 00:00:00

  • Optical pH measurement system using a single fluorescent dye for assessing susceptibility to dental caries.

    abstract::Sugar-rich diets and poor dental hygiene promote the formation of a biofilm (plaque) that strongly adheres to the dental enamel surface and fosters the evolution of aciduric bacteria. The acid contributes to demineralization of the exterior tooth enamel, which accelerates after the pH drops below a critical value (∼5....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.1.017001

    authors: Sharma M,Graham JY,Walczak PA,Nguyen R,Lee LK,Carson MD,Nelson LY,Patel SN,Xu Z,Seibel EJ

    更新日期:2019-01-01 00:00:00

  • Phase-function corrected diffusion model for diffuse reflectance of a pencil beam obliquely incident on a semi-infinite turbid medium.

    abstract::Oblique incidence reflectometry (OIR) is an established technique for the estimation of tissue optical properties. However, a sensing footprint of a few transport mean-free paths is often needed when diffusion-regime-based algorithms are used. Smaller-footprint probes require improved light-propagation models and inve...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.6.067005

    authors: Zemp RJ

    更新日期:2013-06-01 00:00:00

  • Compact instrument for fluorescence image-guided surgery.

    abstract::Fluorescence image-guided surgery (FIGS) is an emerging technique in oncology, neurology, and cardiology. To adapt intraoperative imaging for various surgical applications, increasingly flexible and compact FIGS instruments are necessary. We present a compact, portable FIGS system and demonstrate its use in cardiovasc...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3378128

    authors: Wang X,Bhaumik S,Li Q,Staudinger VP,Yazdanfar S

    更新日期:2010-03-01 00:00:00

  • Evaluation of low-level laser therapy in the treatment of masticatory muscles spasticity in children with cerebral palsy.

    abstract::Spasticity is a motor disorder frequently present in individuals with cerebral palsy (CP). This study aimed to evaluate the effect of low-level laser therapy (LLLT) on the spasticity of the masseter and anterior temporal muscle fibers in children with CP over three weeks of intermittent laser exposures. The bite force...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.2.028001

    authors: Santos MT,Diniz MB,Gouw-Soares SC,Lopes-Martins RA,Frigo L,Baeder FM

    更新日期:2016-02-01 00:00:00

  • Fluorescence-based surface magnifying chromoendoscopy and optical coherence tomography endoscope.

    abstract::A side-viewing, 2.3-mm diameter, surface magnifying chromoendoscopy-optical coherence tomography (SMC-OCT) endoscope has been designed for simultaneous, nondestructive surface fluorescence visualization and cross-sectional imaging. We apply this endoscope to in vivo examination of the mouse colon. A 30,000 element fib...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.086003

    authors: Wall RA,Barton JK

    更新日期:2012-08-01 00:00:00

  • Neural networks improve brain cancer detection with Raman spectroscopy in the presence of operating room light artifacts.

    abstract::Invasive brain cancer cells cannot be visualized during surgery and so they are often not removed. These residual cancer cells give rise to recurrences.

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.9.094002

    authors: Jermyn M,Desroches J,Mercier J,Tremblay MA,St-Arnaud K,Guiot MC,Petrecca K,Leblond F

    更新日期:2016-09-01 00:00:00

  • Handheld projective imaging device for near-infrared fluorescence imaging and intraoperative guidance of sentinel lymph node resection.

    abstract::We propose a handheld projective imaging device for orthotopic projection of near-infrared fluorescence images onto target biological tissue at visible wavelengths without any additional visual aid. The device integrates a laser diode light source module, a camera module, a projector, an ultrasonic distance sensor, a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.8.080503

    authors: Li C,Liu P,Shao P,Pei J,Li Y,Pawlik TM,Martin EW,Xu RX

    更新日期:2019-08-01 00:00:00

  • Quality analysis of in vivo near-infrared fluorescence and conventional gamma images acquired using a dual-labeled tumor-targeting probe.

    abstract::The cyclic peptide, cyclopentapeptide cyclo(lys-Arg-Gly-Asp-phe) (c(KRGDf)), which is known to target alpha(v)beta3 integrin, is dual-labeled with a radiotracer, (111)indium, for gamma scintigraphy as well as with a near-infrared dye, IRDye800, for continuous-wave (cw) imaging of alpha(v)beta3 positive human M21 melan...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2114748

    authors: Houston JP,Ke S,Wang W,Li C,Sevick-Muraca EM

    更新日期:2005-09-01 00:00:00

  • Laser trap ionization for identification of human erythrocytes with variable hemoglobin quantitation.

    abstract::An approach to an established technique that is potentially applicable for a more comprehensive understanding of the electrical properties of red blood cells (RBCs) is presented. Using a high-intensity gradient laser trap, RBCs can be singly trapped and consequentially ionized. The subsequent dynamics of the ionized c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.055005

    authors: Kelley M,Cooper J,Devito D,Mushi R,Aguinaga MDP,Erenso DB

    更新日期:2018-05-01 00:00:00

  • Optical fiber probe spectroscopy for laparoscopic monitoring of tissue oxygenation during esophagectomies.

    abstract::Anastomotic complication is a major morbidity associated with esophagectomy. Gastric ischemia after conduit creation contributes to anastomotic complications, but a reliable method to assess oxygenation in the gastric conduit is lacking. We hypothesize that fiber optic spectroscopy can reliably assess conduit oxygenat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3512149

    authors: Gareau DS,Truffer F,Perry KA,Pham TH,Enestvedt CK,Dolan JP,Hunter JG,Jacques SL

    更新日期:2010-11-01 00:00:00

  • Dialysis-assisted fiber optic spectroscopy for in situ biomedical sensing.

    abstract::A miniature fiber optic spectrometer enclosed within a semipermeable (dialysis) membrane is proposed for in vivo interstitial sensing applications. The semipermeable membrane acts as a molecular filter, allowing only small molecules to pass through to the sampling volume. This filtering, in principle, should enable co...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2166086

    authors: Blazkiewicz P,Blazkiewicz K,Verhaege A,Anissimov YG,Roberts MS,Zvyagin AV

    更新日期:2006-01-01 00:00:00

  • Coregistered optical coherence tomography and frequency-encoded multispectral imaging for spectrally sparse color imaging.

    abstract::We present a system combining optical coherence tomography (OCT) and multispectral imaging (MSI) for coregistered structural imaging and surface color imaging. We first describe and numerically validate an optimization model to guide the selection of the MSI wavelengths and their relative intensities. We then demonstr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.3.032008

    authors: Attendu X,Bourget MH,de Sivry-Houle MP,Boudoux C

    更新日期:2019-11-01 00:00:00

  • Adaptive optics for fluorescence wide-field microscopy using spectrally independent guide star and markers.

    abstract::We describe the implementation and use of an adaptive optics loop in the imaging path of a commercial wide field microscope. We show that it is possible to maintain the optical performances of the original microscope when imaging through aberrant biological samples. The sources used for illuminating the adaptive optic...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3603847

    authors: Vermeulen P,Muro E,Pons T,Loriette V,Fragola A

    更新日期:2011-07-01 00:00:00

  • Real-time brightfield, darkfield, and phase contrast imaging in a light-emitting diode array microscope.

    abstract::We demonstrate a single-camera imaging system that can simultaneously acquire brightfield, darkfield, and phase contrast images in real time. Our method uses computational illumination via a programmable light-emitting diode (LED) array at the source plane, providing flexible patterning of illumination angles. Brightf...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.106002

    authors: Liu Z,Tian L,Liu S,Waller L

    更新日期:2014-01-01 00:00:00

  • Hybrid method for fast Monte Carlo simulation of diffuse reflectance from a multilayered tissue model with tumor-like heterogeneities.

    abstract::We present a hybrid method that combines a multilayered scaling method and a perturbation method to speed up the Monte Carlo simulation of diffuse reflectance from a multilayered tissue model with finite-size tumor-like heterogeneities. The proposed method consists of two steps. In the first step, a set of photon traj...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.1.010501

    authors: Zhu C,Liu Q

    更新日期:2012-01-01 00:00:00

  • Confocal reflectance and two-photon microscopy studies of a songbird skull for preparation of transcranial imaging.

    abstract::We present experiments and analyses of confocal reflectance and two-photon microscopy studies of zebra finch skull samples. The thin and hollow structure of these birds' skulls is quite translucent, which can allow in vivo transcranial two-photon imaging for brain activation monitoring. However, the skull structure is...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3155522

    authors: Abi-Haidar D,Olivier T

    更新日期:2009-05-01 00:00:00

  • Comparative evaluation of differential laser-induced perturbation spectroscopy as a technique to discriminate emerging skin pathology.

    abstract::Fluorescence spectroscopy has been widely investigated as a technique for identifying pathological tissue; however, unrelated subject-to-subject variations in spectra complicate data analysis and interpretation. We describe and evaluate a new biosensing technique, differential laser-induced perturbation spectroscopy (...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.067002

    authors: Kozikowski RT,Smith SE,Lee JA,Castleman WL,Sorg BS,Hahn DW

    更新日期:2012-06-01 00:00:00

  • Anatomical image-guided fluorescence molecular tomography reconstruction using kernel method.

    abstract::Fluorescence molecular tomography (FMT) is an important in vivo imaging modality to visualize physiological and pathological processes in small animals. However, FMT reconstruction is ill-posed and ill-conditioned due to strong optical scattering in deep tissues, which results in poor spatial resolution. It is well kn...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.055001

    authors: Baikejiang R,Zhao Y,Fite BZ,Ferrara KW,Li C

    更新日期:2017-05-01 00:00:00

  • Photochemical decontamination of red cell concentrates with the silicon phthalocyanine pc 4 and red light.

    abstract::Virus inactivation in red blood cell concentrates (RBCC) is being studied in order to increase the safety of the blood supply. For this purpose we have been studying the silicon phthalocyanine (Pc 4), a photosensitizer activated with red light. Two approaches were used to achieve enhanced selectivity of Pc 4 for virus...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429931

    authors: Ben-Hur E,Zuk MM,Oetjen J,Chan WS,Lenny L,Horowitz B

    更新日期:1999-07-01 00:00:00

  • Differentiation of benign and malignant breast tumors by in-vivo three-dimensional parallel-plate diffuse optical tomography.

    abstract::We have developed a novel parallel-plate diffuse optical tomography (DOT) system for three-dimensional in vivo imaging of human breast tumor based on large optical data sets. Images of oxy-, deoxy-, and total hemoglobin concentration as well as blood oxygen saturation and tissue scattering were reconstructed. Tumor ma...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3103325

    authors: Choe R,Konecky SD,Corlu A,Lee K,Durduran T,Busch DR,Pathak S,Czerniecki BJ,Tchou J,Fraker DL,Demichele A,Chance B,Arridge SR,Schweiger M,Culver JP,Schnall MD,Putt ME,Rosen MA,Yodh AG

    更新日期:2009-03-01 00:00:00

  • Comparative analysis of single- and dual-wavelength photodynamic therapy regimes with chlorin-based photosensitizers: animal study.

    abstract::Two pronounced absorption peaks in blue and red ranges of the chlorin-based photosensitizer (PS) absorption spectrum provide additional benefits in photodynamic therapy (PDT) performance. Differing optical properties of biological tissues in these ranges allow for both dual-wavelength diagnostics and PDT performance. ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.6.063804

    authors: Kurakina D,Khilov A,Shakhova M,Orlinskaya N,Sergeeva E,Meller A,Turchin I,Kirillin M

    更新日期:2019-12-01 00:00:00

  • Spectral imaging technique for retinal perfusion detection using confocal scanning laser ophthalmoscopy.

    abstract::To evaluate retinal perfusion in the human eye, a dual-wavelength confocal scanning laser ophthalmoscope (cSLO) was developed that provides spectral imaging of the fundus using a combination of red (670 nm) and near-infrared (810 nm) wavelengths. The image of the ocular fundus was analyzed to find out if quantitative ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.11.116005

    authors: Rasta SH,Manivannan A,Sharp PF

    更新日期:2012-11-01 00:00:00

  • Hybrid photomultiplier tube and photodiode parallel detection array for wideband optical spectroscopy of the breast guided by magnetic resonance imaging.

    abstract::A new optical parallel detection system of hybrid frequency and continuous-wave domains was developed to improve the data quality and accuracy in recovery of all breast optical properties. This new system was deployed in a previously existing system for magnetic resonance imaging (MRI)-guided spectroscopy, and allows ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.1.011010

    authors: El-Ghussein F,Mastanduno MA,Jiang S,Pogue BW,Paulsen KD

    更新日期:2014-01-01 00:00:00

  • Combined anatomical optical coherence tomography and intraluminal pressure reveal viscoelasticity of the in vivo airway.

    abstract::It is hypothesized that the local, viscoelastic (time-dependent) properties of the airway are important to accurately model and ultimately predict dynamic airway collapse in airway obstruction. Toward this end, we present a portable, endoscopic, swept-source anatomical optical coherence tomography (aOCT) system combin...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.23.10.100501

    authors: Balakrishnan S,Bu R,Iftimia N,Price H,Zdanski C,Oldenburg AL

    更新日期:2018-10-01 00:00:00