Photochemical decontamination of red cell concentrates with the silicon phthalocyanine pc 4 and red light.

Abstract:

:Virus inactivation in red blood cell concentrates (RBCC) is being studied in order to increase the safety of the blood supply. For this purpose we have been studying the silicon phthalocyanine (Pc 4), a photosensitizer activated with red light. Two approaches were used to achieve enhanced selectivity of Pc 4 for virus inactivation. One was formulation of Pc 4 in liposomes that reduce its binding to red cells. The other was the use of a light emitting diode (LED) array emitting at 700 nm. Vesicular stomatitis virus (VSV) infectivity served as an endpoint for virus kill in treated RBCC. Red cell hemolysis and circulatory survival in rabbits served as measures for red cell damage. Treatment of small aliquots of human RBCC with 2 μM Pc 4 in liposomes and 10 J/cm2 of 700 nm LED light in the presence of the quenchers of reactive oxygen species glutathione and trolox resulted in 6 log10 inactivation of VSV. Under these conditions hemolysis of treated red cells stored at 4 °C for 21 days was only slightly above that of control cells. Rabbit RBCC similarly treated circulated with a half life of 7.5 days compared with 10.5 days of control. It is concluded that Pc 4 used as described here may be useful for viral decontamination of RBCC, pending toxicological and clinical studies. © 1999 Society of Photo-Optical Instrumentation Engineers.

journal_name

J Biomed Opt

authors

Ben-Hur E,Zuk MM,Oetjen J,Chan WS,Lenny L,Horowitz B

doi

10.1117/1.429931

subject

Has Abstract

pub_date

1999-07-01 00:00:00

pages

292-7

issue

3

eissn

1083-3668

issn

1560-2281

pii

1101276

journal_volume

4

pub_type

杂志文章
  • Vector extrapolation methods for accelerating iterative reconstruction methods in limited-data photoacoustic tomography.

    abstract::As limited data photoacoustic tomographic image reconstruction problem is known to be ill-posed, the iterative reconstruction methods were proven to be effective in terms of providing good quality initial pressure distribution. Often, these iterative methods require a large number of iterations to converge to a soluti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.7.071204

    authors: Awasthi N,Kalva SK,Pramanik M,Yalavarthy PK

    更新日期:2018-02-01 00:00:00

  • Photoacoustic tomography of ex vivo mouse hearts with myocardial infarction.

    abstract::In the present study, we evaluated the applicability of ex vivo photoacoustic imaging (PAI) on small animal organs. We used photoacoustic tomography (PAT) to visualize infarcted areas within murine hearts and compared these data to other imaging techniques [magnetic resonance imaging (MRI), micro-computed tomography] ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3556720

    authors: Holotta M,Grossauer H,Kremser C,Torbica P,Völkl J,Degenhart G,Esterhammer R,Nuster R,Paltauf G,Jaschke W

    更新日期:2011-03-01 00:00:00

  • Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics.

    abstract::Application of a fiber optic biosensor (FOB) to the real-time investigation of the interaction kinetics between FITC-conjugated monoclonal sheep anti-human C-reactive protein (CRP) antibody and CRP isoforms on the surface of optical fiber is described. Recently, both the native pentameric CRP (pCRP), an acute phase pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714029

    authors: Chou C,Hsu HY,Wu HT,Tseng KY,Chiou A,Yu CJ,Lee ZY,Chan TS

    更新日期:2007-03-01 00:00:00

  • High-spatial-resolution deep tissue imaging with spectral-domain optical coherence microscopy in the 1700-nm spectral band.

    abstract::We present three-dimensional (3-D) high-resolution spectral-domain optical coherence microscopy (SD-OCM) by using a supercontinuum (SC) fiber laser source with 300-nm spectral bandwidth (full-width at half-maximum) in the 1700-nm spectral band. By using low-coherence interferometry with SC light and a confocal detecti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.7.070502

    authors: Yamanaka M,Hayakawa N,Nishizawa N

    更新日期:2019-07-01 00:00:00

  • Nanophotothermolysis of multiple scattered cancer cells with carbon nanotubes guided by time-resolved infrared thermal imaging.

    abstract::Nanophotothermolysis with long laser pulses for treatment of scattered cancer cells and their clusters is introduced with the main focus on real-time monitoring of temperature dynamics inside and around individual cancer cells labeled with carbon nanotubes. This technique utilizes advanced time- and spatially-resolved...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3119135

    authors: Biris AS,Boldor D,Palmer J,Monroe WT,Mahmood M,Dervishi E,Xu Y,Li Z,Galanzha EI,Zharov VP

    更新日期:2009-03-01 00:00:00

  • Calibration of diffuse correlation spectroscopy blood flow index with venous-occlusion diffuse optical spectroscopy in skeletal muscle.

    abstract::We investigate and assess the utility of a simple scheme for continuous absolute blood flow monitoring based on diffuse correlation spectroscopy (DCS). The scheme calibrates DCS using venous-occlusion diffuse optical spectroscopy (VO-DOS) measurements of arm muscle tissue at a single time-point. A calibration coeffici...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.125005

    authors: Li Z,Baker WB,Parthasarathy AB,Ko TS,Wang D,Schenkel S,Durduran T,Li G,Yodh AG

    更新日期:2015-01-01 00:00:00

  • Technical considerations in longitudinal multispectral small animal molecular imaging.

    abstract::In a previous study, we investigated physical methods to reduce whole-body, diet-related autofluorescence interference in several mouse strains through changes in animal diet. Measurements of mice with an in vivo multispectral imaging system over a 21-day period allowed for the quantification of concentration changes ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2799188

    authors: Bouchard MB,MacLaurin SA,Dwyer PJ,Mansfield J,Levenson R,Krucker T

    更新日期:2007-09-01 00:00:00

  • Robot-assisted three-dimensional registration for cochlear implant surgery using a common-path swept-source optical coherence tomography probe.

    abstract::Cochlear implantation offers the potential to restore sensitive hearing in patients with severe to profound deafness. However, surgical placement of the electrode array within the cochlea can produce trauma to sensorineural components, particularly if the initial turn of the cochlea is not successfully navigated as th...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.5.057004

    authors: Gurbani SS,Wilkening P,Zhao M,Gonenc B,Cheon GW,Iordachita II,Chien W,Taylor RH,Niparko JK,Kang JU

    更新日期:2014-05-01 00:00:00

  • Blind deconvolution estimation of fluorescence measurements through quadratic programming.

    abstract::Time-deconvolution of the instrument response from fluorescence lifetime imaging microscopy (FLIM) data is usually necessary for accurate fluorescence lifetime estimation. In many applications, however, the instrument response is not available. In such cases, a blind deconvolution approach is required. An iterative me...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.7.075010

    authors: Campos-Delgado DU,Gutierrez-Navarro O,Arce-Santana ER,Skala MC,Walsh AJ,Jo JA

    更新日期:2015-07-01 00:00:00

  • Raman microscopy in the diagnosis and prognosis of surgically resected nonsmall cell lung cancer.

    abstract::The main curative therapy for patients with nonsmall cell lung cancer is surgery. Despite this, the survival rate is only 50%, therefore it is important to more efficiently diagnose and predict prognosis for lung cancer patients. Raman spectroscopy is useful in the diagnosis of malignant and premalignant lesions. The ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3323088

    authors: Magee ND,Beattie JR,Carland C,Davis R,McManus K,Bradbury I,Fennell DA,Hamilton PW,Ennis M,McGarvey JJ,Elborn JS

    更新日期:2010-03-01 00:00:00

  • Optical waveguides formed by silver ion exchange in Schott SG11 glass for waveguide evanescent field fluorescence microscopy: evanescent images of HEK293 cells.

    abstract::Planar glass waveguides with a specific number of modes were fabricated by Ag(+)-Na(+) exchange in Schott SG11 glass. The effective refractive indices were determined using m-line spectroscopy in both s- and p-polarization. By using the reversed Wentzel-Kramers-Brillouin approximation, the index profiles were describe...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3443796

    authors: Hassanzadeh A,Nitsche M,Armstrong S,Nabavi N,Harrison R,Dixon SJ,Langbein U,Mittler S

    更新日期:2010-05-01 00:00:00

  • Pulse-modulated second harmonic imaging microscope quantitatively demonstrates marked increase of collagen in tumor after chemotherapy.

    abstract::Pulse-modulated second harmonic imaging microscopes (PM-SHIMs) exhibit improved signal-to-noise ratio (SNR) over conventional SHIMs on sensitive imaging and quantification of weak collagen signals inside tissues. We quantify the spatial distribution of sparse collagen inside a xenograft model of human acute myeloid le...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3497565

    authors: Raja AM,Xu S,Sun W,Zhou J,Tai DC,Chen CS,Rajapakse JC,So PT,Yu H

    更新日期:2010-09-01 00:00:00

  • Prehistological evaluation of benign and malignant pigmented skin lesions with optical computed tomography.

    abstract::Discrimination of benign and malignant melanocytic lesions is a major issue in clinical dermatology. Assessment of the thickness of melanoma is critical for prognosis and treatment selection. We aimed to evaluate a novel optical computed tomography (optical-CT) system as a tool for three-dimensional (3-D) imaging of m...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.6.066004

    authors: Kokolakis A,Zacharakis G,Krasagakis K,Lasithiotakis K,Favicchio R,Spiliopoulos G,Giannikaki E,Ripoll J,Tosca A

    更新日期:2012-06-01 00:00:00

  • Specific absorption spectra of hemoglobin at different PO2 levels: potential noninvasive method to detect PO2 in tissues.

    abstract::Hemoglobin (Hb), as one of main components of blood, has a unique quaternary structure. Its release of oxygen is controlled by oxygen partial pressure (PO2). We investigate the specific spectroscopic changes in Hb under different PO2 levels to optimize clinical methods of measuring tissue PO2. The transmissivity of Hb...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.12.125002

    authors: Liu P,Zhu Z,Zeng C,Nie G

    更新日期:2012-12-01 00:00:00

  • Optical imaging of acute epileptic networks in mice.

    abstract::The potential of intrinsic optical imaging and resting-state analysis under anesthetized conditions as a tool to study brain networks associated with epileptic seizures is investigated. Using an acute model of epileptiform activity, the 4-aminopyridine model in live mice, we observe the changes in resting-state networ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.7.076021

    authors: Guevara E,Pouliot P,Nguyen DK,Lesage F

    更新日期:2013-07-01 00:00:00

  • Evaluation of BCECF fluorescence ratio imaging to properly measure gastric intramucosal pH variations in vivo.

    abstract::Our purpose is to evaluate intramucosal gastric pH video imaging by 2('),7(')-bis(carboxyethyl)-5,6-carboxyfluorescein (BCECF) fluorescence ratio techniques. We use a video endoscopic imaging system and BCECF as the pH fluorescent probe. Systemic in vivo pH variations are studied in 10 pigs: five in the control group ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2821698

    authors: Rochon P,Jourdain M,Mangalaboyi J,Fourrier F,Soulié-Bégu S,Buys B,Dehlin G,Lesage JC,Chambrin MC,Mordon S

    更新日期:2007-11-01 00:00:00

  • Quantitative diffuse reflectance and fluorescence spectroscopy: tool to monitor tumor physiology in vivo.

    abstract::This study demonstrates the use of optical spectroscopy for monitoring tumor oxygenation and metabolism in response to hyperoxic gas breathing. Hemoglobin saturation and redox ratio were quantified for a set of 14 and 9 mice, respectively, measured at baseline and during carbogen breathing (95% O(2), 5% CO(2)). In par...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3103586

    authors: Palmer GM,Viola RJ,Schroeder T,Yarmolenko PS,Dewhirst MW,Ramanujam N

    更新日期:2009-03-01 00:00:00

  • Comparison of laser and diode sources for acceleration of in vitro wound healing by low-level light therapy.

    abstract::Low-level light therapy has been shown to improve in vitro wound healing. However, well-defined parameters of different light sources for this therapy are lacking. The goal of this study was (1) to determine if the wavelengths tested are effective for in vitro wound healing and (2) to compare a laser and a light-emitt...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.3.038001

    authors: Spitler R,Berns MW

    更新日期:2014-03-01 00:00:00

  • Video-rate optical flow corrected intraoperative functional fluorescence imaging.

    abstract::Intraoperative fluorescence molecular imaging based on targeted fluorescence agents is an emerging approach to improve surgical and endoscopic imaging and guidance. Short exposure times per frame and implementation at video rates are necessary to provide continuous feedback to the physician and avoid motion artifacts....

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.4.046012

    authors: Koch M,Glatz J,Ermolayev V,de Vries EG,van Dam GM,Englmeier KH,Ntziachristos V

    更新日期:2014-04-01 00:00:00

  • Influence of the absorption behavior of sunscreens in the short-wavelength UV range (UVB) and the long-wavelength UV range (UVA) on the relation of the UVB absorption to sun protection factor.

    abstract::The absorption of filter substances in sunscreens, reducing the incident ultraviolet (UV) radiation, is the basis for the protecting ability of such formulations. The erythema-correlated sun protection factor (SPF), depending mainly on the intensity of the UVB radiation, is the common value to quantify the efficacy of...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3497047

    authors: Weigmann HJ,Schanzer S,Antoniou C,Sterry W,Lademann J

    更新日期:2010-09-01 00:00:00

  • Confocal fluorescence microscope with dual-axis architecture and biaxial postobjective scanning.

    abstract::We present a novel confocal microscope that has dual-axis architecture and biaxial postobjective scanning for the collection of fluorescence images from biological specimens. This design uses two low-numerical-aperture lenses to achieve high axial resolution and long working distance, and the scanning mirror located d...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1760760

    authors: Wang TD,Contag CH,Mandella MJ,Chan NY,Kino GS

    更新日期:2004-07-01 00:00:00

  • Shear wave elastography using amplitude-modulated acoustic radiation force and phase-sensitive optical coherence tomography.

    abstract::Investigating the elasticity of ocular tissue (cornea and intraocular lens) could help the understanding and management of pathologies related to biomechanical deficiency. In previous studies, we introduced a setup based on optical coherence tomography for shear wave elastography (SWE) with high resolution and high se...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.1.016001

    authors: Nguyen TM,Arnal B,Song S,Huang Z,Wang RK,O'Donnell M

    更新日期:2015-01-01 00:00:00

  • Quantitative tool for rapid disease mapping using optical coherence tomography images of azoxymethane-treated mouse colon.

    abstract::Optical coherence tomography (OCT) can provide new insight into disease progression and therapy by enabling nondestructive, serial imaging of in vivo cancer models. In previous studies, we have shown the utility of endoscopic OCT for identifying adenomas in the azoxymethane-treated mouse model of colorectal cancer and...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3446674

    authors: Winkler AM,Rice PF,Drezek RA,Barton JK

    更新日期:2010-07-01 00:00:00

  • Spatiotemporal laser speckle contrast analysis for blood flow imaging with maximized speckle contrast.

    abstract::Laser speckle contrast imaging is a technique used for imaging blood flow without scanning. Though several studies have attempted to combine spatial and temporal statistics of laser speckle images for reducing image noise as well as preserving acceptable spatiotemporal resolution, the statistical accuracy of these spa...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3290804

    authors: Qiu J,Li P,Luo W,Wang J,Zhang H,Luo Q

    更新日期:2010-01-01 00:00:00

  • Simultaneous imaging of multiple focal planes for three-dimensional microscopy using ultra-high-speed adaptive optics.

    abstract::Traditional white-light and fluorescent imaging techniques provide powerful methods to extract high-resolution information from two-dimensional (2-D) sections, but to retrieve information from a three-dimensional (3-D) volume they require relatively slow scanning methods that result in increased acquisition time. Usin...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.17.5.050505

    authors: Duocastella M,Sun B,Arnold CB

    更新日期:2012-05-01 00:00:00

  • Properties of erythrocyte light refraction in diabetic patients.

    abstract::Since hyperglycaemia changes the erythrocyte cell membrane fluidity and impairs cell deformity, our goal was to characterize hemoglobin and red blood cell (RBC) light refractive property changes in diabetic patients. Microscopic investigation was carried out on intact and fixed RBCs. To determine the refractive index ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1463043

    authors: Mazarevica G,Freivalds T,Jurka A

    更新日期:2002-04-01 00:00:00

  • Pancreatic cancer cell detection by targeted lipid microbubbles and multiphoton imaging.

    abstract::Surgical resection of pancreatic cancer represents the only chance of cure and long-term survival in this common disease. Unfortunately, determination of a cancer-free margin at surgery is based on one or two tiny frozen section biopsies, which is far from ideal. Not surprisingly, cancer is usually left behind and is ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.4.046501

    authors: Cromey B,McDaniel A,Matsunaga T,Vagner J,Kieu KQ,Banerjee B

    更新日期:2018-04-01 00:00:00

  • Detecting inflammation in rheumatoid arthritis using Fourier transform analysis of dorsal optical transmission images from a pilot study.

    abstract::A clinical need exists for low-cost and noninvasive imaging tools capable of detecting inflammation in the joints of inflammatory arthritis patients. Previous studies have reported an optical contrast between inflamed and noninflamed joints resulting from distinct absorption and scattering properties. Accurate classif...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.6.066008

    authors: Lighter D,Filer A,Dehghani H

    更新日期:2019-06-01 00:00:00

  • Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography.

    abstract::A method is proposed for determining the glucose concentration on the human fingertip by extracting two optical parameters, namely the optical rotation angle and the depolarization index, using a Mueller optical coherence tomography technique and a genetic algorithm. The feasibility of the proposed method is demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.4.047001

    authors: Chen TL,Lo YL,Liao CC,Phan QH

    更新日期:2018-04-01 00:00:00

  • Fluorescence microscopy imaging of electroperturbation in mammalian cells.

    abstract::We report the design, integration, and validation of a fluorescence microscopy system for imaging of electroperturbation--the effects of nanosecond, megavolt-per-meter pulsed electric fields on biological cells and tissues. Such effects have potential applications in cancer therapy, gene regulation, and biophysical re...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2187970

    authors: Sun Y,Vernier PT,Behrend M,Wang J,Thu MM,Gundersen M,Marcu L

    更新日期:2006-03-01 00:00:00