Abstract:
:In a previous study, we investigated physical methods to reduce whole-body, diet-related autofluorescence interference in several mouse strains through changes in animal diet. Measurements of mice with an in vivo multispectral imaging system over a 21-day period allowed for the quantification of concentration changes in multiple in vivo fluorophores. To be an effective instrument, a multispectral imaging system requires a priori spectral knowledge, the form and importance of which is not necessarily intuitive, particularly when noninvasive in vivo longitudinal imaging studies are performed. Using an optimized spectral library from a previous autofluorescence-reduction study as a model, we investigated two additional spectral definition techniques to illustrate the results of poor spectral definition in a longitudinal fluorescence imaging study. Here we systematically evaluate these results and show how poor spectral definition can lead to physiologically irrelevant results. This study concludes that the proper selection of robust spectra corresponding to each specific fluorescent molecular label of interest is of integral importance to enable effective use of multispectral imaging techniques in longitudinal fluorescence studies.
journal_name
J Biomed Optjournal_title
Journal of biomedical opticsauthors
Bouchard MB,MacLaurin SA,Dwyer PJ,Mansfield J,Levenson R,Krucker Tdoi
10.1117/1.2799188subject
Has Abstractpub_date
2007-09-01 00:00:00pages
051601issue
5eissn
1083-3668issn
1560-2281journal_volume
12pub_type
杂志文章abstract::A Monte Carlo algorithm is applied to simulate the measurements of a sample with glass slides sandwiched between the double integrating sphere (DIS) setup. The effects caused by various parameters, such as the sample port of integrating sphere, thicknesses, and optical properties of the sample, on light losses and opt...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.2815691
更新日期:2007-11-01 00:00:00
abstract::New diagnostic tools are needed for the characterization of dental caries in the early stages of development. If carious lesions are detected early enough, they can be arrested without the need for surgical intervention. The objective of this study was to demonstrate that polarization sensitive optical coherence tomog...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1509752
更新日期:2002-10-01 00:00:00
abstract::Color Doppler optical coherence tomography (CDOCT) is a functional extension of optical coherence tomography (OCT) that can image flow in turbid media. We have developed a CDOCT system capable of imaging flow in real time. Doppler processing of the analog signal is accomplished in hardware in the time domain using a n...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1428291
更新日期:2002-01-01 00:00:00
abstract::Cortical spreading depression (CSD) is a pronounced depolarization of neurons and glia that spreads slowly across the cortex followed by a period of depressed electrophysiological activity. The vascular changes associated with CSD are a large transient increase in blood flow followed by a prolonged decrease lasting gr...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1852556
更新日期:2005-01-01 00:00:00
abstract::Metal nanoparticles can be functionalized with biomolecules to selectively localize in precancerous tissues and can act as optical contrast enhancers for reflectance-based diagnosis of epithelial precancer. We carry out Monte Carlo (MC) simulations to analyze photon propagation through nanoparticle-labeled tissues and...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3608999
更新日期:2011-08-01 00:00:00
abstract::Functional near-infrared spectroscopy is prone to contamination by motion artifacts (MAs). Motion correction algorithms have previously been proposed and their respective performance compared for evoked rain activation studies. We study instead the effect of MAs on "oscillation" data which is at the basis of functiona...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.5.056011
更新日期:2015-05-01 00:00:00
abstract::Ambulatory diffuse optical tomography (aDOT) is based on near-infrared spectroscopy (NIRS) and enables three-dimensional imaging of regional hemodynamics and oxygen consumption during a person’s normal activities. Although NIRS has been previously used for muscle assessment, it has been notably limited in terms of the...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.9.091314
更新日期:2016-09-01 00:00:00
abstract::The capabilities of micro-Raman spectroscopy for differentiating normal and malignant nasopharyngeal tissues were evaluated. Raman scattering signals were acquired from 22 normal and 52 malignant nasopharyngeal tissue samples. Distinctive spectral differences in Raman spectra between normal and malignant nasopharyngea...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.2.027003
更新日期:2013-02-01 00:00:00
abstract::Simplified measurement of macular pigment optical density (MPOD) is important because of the ocular health benefits that are attributed to these retinal carotenoids. Here, we describe a novel instrument designed for this purpose, based on heterochromatic flicker photometry (HFP), which removes a number of difficulties...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.18.10.107003
更新日期:2013-10-01 00:00:00
abstract::We report noninvasive, in vivo optical imaging deep within a mouse brain by swept-source optical coherence tomography (SS-OCT), enabled by a 1.3-μm vertical cavity surface emitting laser (VCSEL). VCSEL SS-OCT offers a constant signal sensitivity of 105 dB throughout an entire depth of 4.25 mm in air, ensuring an exten...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.20.10.106004
更新日期:2015-10-01 00:00:00
abstract::We describe the protocol for an inexpensive and nondestructive optical reflectance assay for the measurement of biofilm formation. Reflectance data are obtained using an Ocean Optics (Dunedin, Florida) USB 2000 spectrometer with a polychromatic light source. A fiber optic cable is used both for illumination and collec...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1953347
更新日期:2005-07-01 00:00:00
abstract::To evaluate retinal perfusion in the human eye, a dual-wavelength confocal scanning laser ophthalmoscope (cSLO) was developed that provides spectral imaging of the fundus using a combination of red (670 nm) and near-infrared (810 nm) wavelengths. The image of the ocular fundus was analyzed to find out if quantitative ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.11.116005
更新日期:2012-11-01 00:00:00
abstract::The measurement of changes in blood volume in tissue is important for monitoring the effects of a wide range of therapeutic interventions, from radiation therapy to skin-flap transplants. Many systems available for purchase are either expensive or difficult to use, limiting their utility in the clinical setting. A low...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.10.105005
更新日期:2014-01-01 00:00:00
abstract::Lucigenin- and luminol-dependent chemiluminescence [(LC-CL) and (LM-CL)] in nondiluted human blood was studied. LM-CL was low in fresh blood and disappeared after its storage for 3 h, though the respiratory burst (RB) stimulation in blood was followed by high intensity and long-lasting LM-CL. LC-CL was high in fresh b...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.429921
更新日期:1999-01-01 00:00:00
abstract::We present a study using a method able to assess tissue oxygenation, taking into account the absorption and the level of scattering in myocardial tissue using a calibrated fiber optic probe. With this method, interindividual comparisons of oxygenation can be made despite varying tissue optical properties during corona...
journal_title:Journal of biomedical optics
pub_type: 临床试验,杂志文章
doi:10.1117/1.2976433
更新日期:2008-09-01 00:00:00
abstract::The laser ablation rate of subgingival dental calculus irradiated at a 400-nm-wavelength, 7.4-mJ pulse energy, and 85- and 20-deg irradiation angles is measured using laser triangulation. Three-dimensional images taken before and after irradiation create a removal map with 6-μm axial resolution. Fifteen human teeth wi...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3564907
更新日期:2011-07-01 00:00:00
abstract::The nEUROPt protocol is one of two new protocols developed within the European project nEUROPt to characterize the performances of time-domain systems for optical imaging of the brain. It was applied in joint measurement campaigns to compare the various instruments and to assess the impact of technical improvements. T...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.19.8.086012
更新日期:2014-08-01 00:00:00
abstract::The atrial pacemaker complex is responsible for the initiation and early propagation of cardiac impulses. Optical coherence tomography (OCT), a nondestructive imaging modality with spatial resolutions of ∼1 to 15 μm, can be used to identify unique fiber orientation patterns in this region of the heart. Functionally ch...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.17.7.071309
更新日期:2012-07-01 00:00:00
abstract::Multiphoton microscopy has evolved into a powerful bioimaging tool in three dimensions. However, the ability to image biological specimens in-depth can be hindered by sample spherical aberration and scattering. These two phenomena can result in the degradation of image resolution and the loss of detected multiphoton s...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1924614
更新日期:2005-05-01 00:00:00
abstract::Model-based light scattering spectroscopy (LSS) seemed a promising technique for in-vivo diagnosis of dysplasia in multiple organs. In the studies, the residual spectrum, the difference between the observed and modeled diffuse reflectance spectra, was attributed to single elastic light scattering from epithelial nucle...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3116708
更新日期:2009-03-01 00:00:00
abstract::During emergency medical situations, where the patient has an obstructed airway or necessitates respiratory support, endotracheal intubation (ETI) is the medical technique of placing a tube into the trachea in order to facilitate adequate ventilation of the lungs. Complications during ETI, such as repeated attempts, f...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.21.11.117004
更新日期:2016-11-01 00:00:00
abstract::The specificity of molecular and functional photoacoustic (PA) images depends on the accuracy of the photoacoustic absorption spectroscopy. The PA signal is proportional to the product of the optical absorption coefficient and local light fluence; quantitative PA measurements of the optical absorption coefficient ther...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3626212
更新日期:2011-09-01 00:00:00
abstract::Recent technological advancements in the photonics industry have led to a resurgence of interest in optical glucose sensing and to realistic progress toward the development of an optical glucose sensor. Such a sensor has the potential to significantly improve the quality of life for the estimated 16 million diabetics ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章,评审
doi:10.1117/1.429962
更新日期:2000-01-01 00:00:00
abstract::Previous studies have shown the ability of many lymphatic vessels to contract phasically to pump lymph. Every lymphangion can act like a heart with pacemaker sites that initiate the phasic contractions. The contractile wave propagates along the vessel to synchronize the contraction. However, determining the location o...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3544512
更新日期:2011-02-01 00:00:00
abstract:SIGNIFICANCE:The blood-brain barrier (BBB) is a major obstacle to detecting and treating brain tumors. Overcoming this challenge will facilitate the early and accurate detection of brain lesions and guide surgical resection of tumors. AIM:We generated an orthotopic brain tumor model that simulates the pathophysiology ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.25.2.026004
更新日期:2020-02-01 00:00:00
abstract::We propose a rate process model for describing photochemical damage to retinal cells by short wavelength laser exposures. The rate equation for photochemical damage contains a positive rate that is temperature independent, and a negative (quenching) rate that is temperature dependent. Using the traditional Arrhenius i...
journal_title:Journal of biomedical optics
pub_type: 信件
doi:10.1117/1.3544504
更新日期:2011-02-01 00:00:00
abstract:SIGNIFICANCE:Melanoma is a deadly cancer that physicians struggle to diagnose early because they lack the knowledge to differentiate benign from malignant lesions. Deep machine learning approaches to image analysis offer promise but lack the transparency to be widely adopted as stand-alone diagnostics. AIM:We aimed to...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.25.11.112906
更新日期:2020-11-01 00:00:00
abstract::Although perfectly transparent specimens are imaged faster with light-sheet microscopy, less transparent samples are often imaged with two-photon microscopy leveraging its robustness to scattering; however, at the price of increased acquisition times. Clearing methods that are capable of rendering strongly scattering ...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.JBO.23.2.020503
更新日期:2018-02-01 00:00:00
abstract::Cardiac architecture is inherently three-dimensional, yet most characterizations rely on two-dimensional histological slices or dissociated cells, which remove the native geometry of the heart. We previously developed a method for labeling intact heart sections without dissociation and imaging large volumes while pres...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.3200939
更新日期:2009-07-01 00:00:00
abstract::A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon fl...
journal_title:Journal of biomedical optics
pub_type: 杂志文章
doi:10.1117/1.1383062
更新日期:2001-07-01 00:00:00