High-spatial-resolution deep tissue imaging with spectral-domain optical coherence microscopy in the 1700-nm spectral band.

Abstract:

:We present three-dimensional (3-D) high-resolution spectral-domain optical coherence microscopy (SD-OCM) by using a supercontinuum (SC) fiber laser source with 300-nm spectral bandwidth (full-width at half-maximum) in the 1700-nm spectral band. By using low-coherence interferometry with SC light and a confocal detection scheme, we realized lateral and axial resolutions of 3.4 and 3.8  μm in tissue (n  =  1.38), respectively. This is, to the best of our knowledge, the highest 3-D spatial resolution reported among those of Fourier-domain optical coherence imaging techniques in the 1700-nm spectral band. In our SD-OCM, to enhance the imaging depth, a full-range method was implemented, which suppressed the formation of a coherent ghost image and allowed us to set the zero-delay position inside the samples. We demonstrated the 3-D high-resolution imaging capability of 1700-nm SD-OCM through the measurement of an interference signal from a mirror surface and imaging of a single 200-nm polystyrene bead and a pig thyroid gland. Deep tissue imaging at a depth of up to 1.8 mm was also demonstrated. This is the first demonstration of 3-D high-resolution SD-OCM in the 1700-nm spectral band.

journal_name

J Biomed Opt

authors

Yamanaka M,Hayakawa N,Nishizawa N

doi

10.1117/1.JBO.24.7.070502

subject

Has Abstract

pub_date

2019-07-01 00:00:00

pages

1-4

issue

7

eissn

1083-3668

issn

1560-2281

pii

JBO-190131LR

journal_volume

24

pub_type

杂志文章
  • Properties of contact pressure induced by manually operated fiber-optic probes.

    abstract::We assess the properties of contact pressure applied by manually operated fiber-optic probes as a function of the operator, probe contact area, and sample stiffness. First, the mechanical properties of human skin sites with different skin structures, thicknesses, and underlying tissues were studied by in vivo indentat...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.12.127002

    authors: Bregar M,Cugmas B,Naglic P,Hartmann D,Pernuš F,Likar B,Bürmen M

    更新日期:2015-01-01 00:00:00

  • Fiber optic biosensor for the detection of C-reactive protein and the study of protein binding kinetics.

    abstract::Application of a fiber optic biosensor (FOB) to the real-time investigation of the interaction kinetics between FITC-conjugated monoclonal sheep anti-human C-reactive protein (CRP) antibody and CRP isoforms on the surface of optical fiber is described. Recently, both the native pentameric CRP (pCRP), an acute phase pr...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2714029

    authors: Chou C,Hsu HY,Wu HT,Tseng KY,Chiou A,Yu CJ,Lee ZY,Chan TS

    更新日期:2007-03-01 00:00:00

  • From quantitative microscopy to automated image understanding.

    abstract::Quantitative microscopy has been extensively used in biomedical research and has provided significant insights into structure and dynamics at the cell and tissue level. The entire procedure of quantitative microscopy is comprised of specimen preparation, light absorption/reflection/emission from the specimen, microsco...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.1779233

    authors: Huang K,Murphy RF

    更新日期:2004-09-01 00:00:00

  • Fluorescence confocal endomicroscopy of the cervix: pilot study on the potential and limitations for clinical implementation.

    abstract::Current diagnostic capabilities and limitations of fluorescence endomicroscopy in the cervix are assessed by qualitative and quantitative image analysis. Four cervical tissue types are investigated: normal columnar epithelium, normal and precancerous squamous epithelium, and stromal tissue. This study focuses on the p...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.126011

    authors: Schlosser C,Bodenschatz N,Lam S,Lee M,McAlpine JN,Miller DM,Van Niekerk DJ,Follen M,Guillaud M,MacAulay CE,Lane PM

    更新日期:2016-12-01 00:00:00

  • In vivo spectral imaging of different cell types in the small intestine by two-photon excited autofluorescence.

    abstract::Spectrally resolved two-photon excited autofluorescence imaging is used to distinguish different cell types and functional areas during dynamic processes in the living gut. Excitation and emission spectra of mucosal tissue and tissue components are correlated to spectra of endogenous chromophores. We show that selecti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3655587

    authors: Orzekowsky-Schroeder R,Klinger A,Martensen B,Blessenohl M,Gebert A,Vogel A,Hüttmann G

    更新日期:2011-11-01 00:00:00

  • Real-time in vivo color Doppler optical coherence tomography.

    abstract::Color Doppler optical coherence tomography (CDOCT) is a functional extension of optical coherence tomography (OCT) that can image flow in turbid media. We have developed a CDOCT system capable of imaging flow in real time. Doppler processing of the analog signal is accomplished in hardware in the time domain using a n...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1428291

    authors: Rollins AM,Yazdanfar S,Barton JK,Izatt JA

    更新日期:2002-01-01 00:00:00

  • Angiography with a multifunctional line scanning ophthalmoscope.

    abstract::A multifunctional line scanning ophthalmoscope (mLSO) was designed, constructed, and tested on human subjects. The mLSO could sequentially acquire wide-field, confocal, near-infrared reflectance, fluorescein angiography (FA), and indocyanine green angiography (ICGA) retinal images. The system also included a retinal t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.026008

    authors: Hammer DX,Ferguson RD,Patel AH,Vazquez V,Husain D

    更新日期:2012-02-01 00:00:00

  • Quantification of in vivo fluorescence decoupled from the effects of tissue optical properties using fiber-optic spectroscopy measurements.

    abstract::We present a method for tissue fluorescence quantification in situ using a handheld fiber optic probe that measures both the fluorescence and diffuse reflectance spectra. A simplified method to decouple the fluorescence spectrum from distorting effects of the tissue optical absorption and scattering is developed, with...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3523616

    authors: Kim A,Khurana M,Moriyama Y,Wilson BC

    更新日期:2010-11-01 00:00:00

  • Polarization-correlation mapping of biological tissue coherent images.

    abstract::We investigate the statistical polarization parameters of biological tissue histological section images with different morphological structure. First we outline the results of polarization coordinate mapping and analysis of the statistics of the first to fourth orders of biological tissue image polarization azimuth an...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2148251

    authors: Angelsky OV,Ushenko AG,Ushenko YA,Ushenko YG,Tomka YY,Pishak VP

    更新日期:2005-11-01 00:00:00

  • Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction.

    abstract::Intravascular near-infrared fluorescence (NIRF) imaging offers a new approach for characterizing atherosclerotic plaque, but random catheter positioning within the vessel lumen results in variable light attenuation and can yield inaccurate measurements. We hypothesized that NIRF measurements could be corrected for var...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.5.056009

    authors: Dixon AJ,Hossack JA

    更新日期:2013-05-01 00:00:00

  • Optical tweezers study of red blood cell aggregation and disaggregation in plasma and protein solutions.

    abstract::Kinetics of optical tweezers (OT)-induced spontaneous aggregation and disaggregation of red blood cells (RBCs) were studied at the level of cell doublets to assess RBC interaction mechanics. Measurements were performed under in vitro conditions in plasma and fibrinogen and fibrinogen + albumin solutions. The RBC spont...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.3.035001

    authors: Lee K,Kinnunen M,Khokhlova MD,Lyubin EV,Priezzhev AV,Meglinski I,Fedyanin AA

    更新日期:2016-03-01 00:00:00

  • Potential of optical microangiography to monitor cerebral blood perfusion and vascular plasticity following traumatic brain injury in mice in vivo.

    abstract::Optical microanglography (OMAG) is a recently developed imaging modality capable of volumetric imaging of dynamic blood perfusion, down to capillary level resolution, with an imaging depth up to 2.00 mm beneath the tissue surface. We report the use of OMAG to monitor the cerebral blood flow (CBF) over the cortex of mo...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3207121

    authors: Jia Y,Alkayed N,Wang RK

    更新日期:2009-07-01 00:00:00

  • Needle-based fluorescence endomicroscopy via structured illumination with a plastic, achromatic objective.

    abstract::In order to diagnose cancer, a sample must be removed, prepared, and examined under a microscope, which is expensive, invasive, and time consuming. Fiber optic fluorescence endomicroscopy, where an image guide is used to obtain high-resolution images of tissue in vivo, has shown promise as an alternative to convention...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.9.096003

    authors: Kyrish M,Dobbs J,Jain S,Wang X,Yu D,Richards-Kortum R,Tkaczyk TS

    更新日期:2013-09-01 00:00:00

  • Mathematical model that describes the transition from thermal to photochemical damage in retinal pigment epithelial cell culture.

    abstract::We propose a rate process model for describing photochemical damage to retinal cells by short wavelength laser exposures. The rate equation for photochemical damage contains a positive rate that is temperature independent, and a negative (quenching) rate that is temperature dependent. Using the traditional Arrhenius i...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.3544504

    authors: Clark CD 3rd,Denton ML,Thomas RJ

    更新日期:2011-02-01 00:00:00

  • Confocal reflectance and two-photon microscopy studies of a songbird skull for preparation of transcranial imaging.

    abstract::We present experiments and analyses of confocal reflectance and two-photon microscopy studies of zebra finch skull samples. The thin and hollow structure of these birds' skulls is quite translucent, which can allow in vivo transcranial two-photon imaging for brain activation monitoring. However, the skull structure is...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3155522

    authors: Abi-Haidar D,Olivier T

    更新日期:2009-05-01 00:00:00

  • Real-time in vivo photoacoustic and ultrasound imaging.

    abstract::A real-time photoacoustic imaging system is designed and built. This system is based on a commercially available ultrasound imaging system. It can achieve a frame rate of 8 frames/sec. Vasculature in the hand of a human volunteer is imaged, and the resulting photoacoustic image is combined with the ultrasound image. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3005421

    authors: Kolkman RG,Brands PJ,Steenbergen W,van Leeuwen TG

    更新日期:2008-09-01 00:00:00

  • Extraction of optical properties and prediction of light distribution in rat brain tissue.

    abstract::Predicting the distribution of light inside any turbid media, such as biological tissue, requires detailed information about the optical properties of the medium, including the absorption and scattering coefficients and the anisotropy factor. Particularly, in biophotonic applications where photons directly interact wi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.7.075001

    authors: Azimipour M,Baumgartner R,Liu Y,Jacques SL,Eliceiri K,Pashaie R

    更新日期:2014-01-01 00:00:00

  • Measuring hemoglobin spectra: searching for carbamino-hemoglobin.

    abstract:SIGNIFICANCE:The arterial carbon dioxide (CO2) partial pressure PaCO2 is a clinically relevant variable. However, its measurement requires arterial blood sampling or bulky and expensive transcutaneous PtcCO2 meters. While the spectrophotometric determination of hemoglobin species-such as oxy-hemoglobin (O2Hb) and deoxy...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.10.105001

    authors: Dervieux E,Bodinier Q,Uhring W,Théron M

    更新日期:2020-10-01 00:00:00

  • Laser scoop desobliteration: a method for minimally invasive remote recanalization of chronically occluded superficial femoral arteries.

    abstract::Stenosis and occlusion of the superficial femoral artery (SFA) are most common in arterial occlusive disease. There are numerous interventional, surgical, and combined approaches to reconstitute maximum blood supply to the lower limb; however, despite intense clinical research, the long-term success rates are still po...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.2.025005

    authors: Heneweer C,Siggelkow M,Helle M,Petzina R,Wulff A,Schaefer JP,Berndt R,Rusch R,Wedel T,Klaws G,Müller-Gerbl M,Röcken C,Jansen O,Lutter G,Cremer J,Groß J

    更新日期:2015-02-01 00:00:00

  • Propagation of coherent polarized light in turbid highly scattering medium.

    abstract::Within the framework of further development of unified Monte Carlo code for the needs of biomedical optics and biophotonics, we present an approach for modeling of coherent polarized light propagation in highly scattering turbid media, such as biological tissues. The temporal coherence of light, linear and circular po...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.2.025005

    authors: Doronin A,Macdonald C,Meglinski I

    更新日期:2014-02-01 00:00:00

  • Two-photon microscopy and spectroscopy based on a compact confocal scanning head.

    abstract::We have combined a confocal laser scanning head modified for TPE (two-photon excitation) microscopy with some spectroscopic modules to study single molecules and molecular aggregates. The behavior of the TPE microscope unit has been characterized by means of point spread function measurements and of the demonstration ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.1382809

    authors: Diaspro A,Chirico G,Federici F,Cannone F,Beretta S,Robello M

    更新日期:2001-07-01 00:00:00

  • Characterization of retinal biomechanical properties using Brillouin microscopy.

    abstract:SIGNIFICANCE:The retina is critical for vision, and several diseases may alter its biomechanical properties. However, assessing the biomechanical properties of the retina nondestructively is a challenge due to its fragile nature and location within the eye globe. Advancements in Brillouin spectroscopy have provided the...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.9.090502

    authors: Ambekar YS,Singh M,Scarcelli G,Rueda EM,Hall BM,Poché RA,Larin KV

    更新日期:2020-09-01 00:00:00

  • Acoustic attenuation compensation in photoacoustic tomography using time-variant filtering.

    abstract::Most reconstruction algorithms used in photoacoustic tomography do not account for the effects of acoustic attenuation on the recorded signals. For experimental measurements made in biological tissue, the frequency dependent acoustic attenuation causes high frequency components of the propagating photoacoustic waves t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.18.3.036008

    authors: Treeby BE

    更新日期:2013-03-01 00:00:00

  • Measurement and imaging of birefringent properties of the human cornea with phase-resolved, polarization-sensitive optical coherence tomography.

    abstract::Optical coherence tomography (OCT) is an emerging technology for high-resolution, noncontact imaging of transparent and scattering media. Polarization-sensitive optical coherence tomography (PS-OCT) is a functional extension of OCT that can image birefringent properties of a biological sample. PS-OCT was used to measu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1629308

    authors: Götzinger E,Pircher M,Sticker M,Fercher AF,Hitzenberger CK

    更新日期:2004-01-01 00:00:00

  • High temperature heat source generation with quasi-continuous wave semiconductor lasers at power levels of 6 W for medical use.

    abstract::We investigate a technology to create a high temperature heat source on the tip surface of the glass fiber proposed for medical surgery applications. Using 4 to 6 W power level semiconductor lasers at a wavelength of 980 nm, a laser coupled fiber tip was preprocessed to contain a certain amount of titanium oxide powde...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.10.101502

    authors: Fujimoto T,Imai Y,Tei K,Ito S,Kanazawa H,Yamaguchi S

    更新日期:2014-01-01 00:00:00

  • Photoacoustic properties of anterior ocular tissues.

    abstract::Clinical imaging techniques for the anterior segment of the eye provide excellent anatomical information, but molecular imaging techniques are lacking. Molecular photoacoustic imaging is one option to address this need, but implementation requires use of contrast agents to distinguish molecular targets from background...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.5.056004

    authors: Kubelick KP,Snider EJ,Ethier CR,Emelianov S

    更新日期:2019-05-01 00:00:00

  • Spectral Doppler optical coherence tomography imaging of localized ischemic stroke in a mouse model.

    abstract::We report the use of spectral Doppler optical coherence tomography imaging (SDOCTI) for quantitative evaluation of dynamic blood circulation before and after a localized ischemic stroke in a mouse model. Rose Bengal photodynamic therapy (PDT) is used as a noninvasive means for inducing localized ischemia in cortical m...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3505016

    authors: Yu L,Nguyen E,Liu G,Choi B,Chen Z

    更新日期:2010-11-01 00:00:00

  • Deep learning-level melanoma detection by interpretable machine learning and imaging biomarker cues.

    abstract:SIGNIFICANCE:Melanoma is a deadly cancer that physicians struggle to diagnose early because they lack the knowledge to differentiate benign from malignant lesions. Deep machine learning approaches to image analysis offer promise but lack the transparency to be widely adopted as stand-alone diagnostics. AIM:We aimed to...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.11.112906

    authors: Gareau DS,Browning J,Correa Da Rosa J,Suarez-Farinas M,Lish S,Zong AM,Firester B,Vrattos C,Renert-Yuval Y,Gamboa M,Vallone MG,Barragán-Estudillo ZF,Tamez-Peña AL,Montoya J,Jesús-Silva MA,Carrera C,Malvehy J,Puig S,Mar

    更新日期:2020-11-01 00:00:00

  • Detecting glucose-induced changes in in vitro and in vivo experiments with optical coherence tomography.

    abstract::Optical clearing is a well-known phenomenon. It is based on the matching of refractive indices of a bulk material and scattering particles. The same principle is also used in scattering-based optical measurements of different constituents, such as glucose. By registering changes in scattering, it is possible to evalua...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2904957

    authors: Kinnunen M,Myllylä R,Vainio S

    更新日期:2008-03-01 00:00:00

  • Optical redox imaging indices discriminate human breast cancer from normal tissues.

    abstract::Our long-term goal was to investigate the potential of incorporating redox imaging technique as a breast cancer (BC) diagnosis component to increase the positive predictive value of suspicious imaging finding and to reduce unnecessary biopsies and overdiagnosis. We previously found that precancer and cancer tissues in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.11.114003

    authors: Xu HN,Tchou J,Feng M,Zhao H,Li LZ

    更新日期:2016-11-01 00:00:00